• Title/Summary/Keyword: Rotation movement

Search Result 623, Processing Time 0.024 seconds

Design and Fabrication of an Automatic Alignment and Loading System for Workpieces (공작물 적재를 위한 자동정렬 및 적재장치의 설계 및 제작)

  • Lee, Jae-Kyung;Choi, Myung-Chul;Kim, Gab-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.3
    • /
    • pp.134-140
    • /
    • 2018
  • This paper describes the design and fabrication of an automatic alignment and loading system for workpieces. To move a workpiece to a chucking position of a machine tool using a gantry robot, an automatic aligning device is required to load the workpiece before machining and automatically align them. The automatic alignment system was conceptually designed, and the structural analysis was performed for the main parts such as the top plate, center support, front and back support, and support shaft. Based on the structural analysis results, the size of these structures was determined. The automatic alignment system was manufactured, and the vertical movement characteristics of the workpiece up-and-down movement device and the rotation characteristics of the workpiece rotation device were experimentally examined. The result has confirmed that they operate normally.

A Study on the Torque Characteristics of Rotary Dampers (로터리 댐퍼의 토오크 특성에 관한 연구)

  • Lee, Choon Tae
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.87-92
    • /
    • 2019
  • Rotary dampers are damping devices which provide high resistance to shaft rotation. Rotary dampers are being used in various areas to enable the gentle opening and closing of the rotation motion relative to home furniture, industry machinery and automotive parts. Rotary dampers can be installed directly at the rotating point of a various part and can achieve uniform, gentle movement which increases quality and value of products. And generally, the silicone fluid is used as the damping medium because of its stable viscous properties. The movement of these little decelerators can be achieved with a high viscosity of working fluid and throttles installed in the body of the rotary damper. The damping force can be achieved clockwise, anti-clockwise or in both directions according to the structure of the orifices or throttles. In this paper, the torque performances of the rotary damper containing air in the working fluid were studied. For this purpose, the torque characteristic of the rotary damper according to the variation of various operating conditions such as clearance of leakage, dimensions of groove orifice, content ratio of air, etc., were simulated with AMEsim software.

Change of the Cement Mantle Thickness According to the Movement of the Femoral Stem in THRA (인공고관절 치환술에서 대퇴주대 회전에 따른 시멘트막 두께 변화)

  • Park, Yong-Kuk;Kim, Jin-Gon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.2 s.191
    • /
    • pp.140-148
    • /
    • 2007
  • THRA(Total Hip Replacement Arthroplasty) has been widely used for several decades as a viable treatment of otherwise-unsolved hip problems. In THRA surgery, cement mantle thickness is critical to long-term implant survival of femoral stem fixed with cement. Numerous studies reported thin or incomplete cement mantle causes osteolysis, loosening, and the failure of implant. To analyze the effect of femoral stem rotation on cement thickness, in this study, we select two most popular stems used in THRA. Using CAD models obtained from a 3D scanner, we measure the cement mantle thickness developed by the rotation of a femoral stem in the virtual space created by broaching. The study shows that as the femoral stem deviates from the target coordinates, the minimum thickness of cement decreases. Therefore, we recommend development of a new methodology for accurate insertion of a femoral stem along the broached space. Also, modification of the stem design robust to the unintentional movement of a femoral stem in the broached space, can alleviate the problem.

High-Speed Image Matching Method Using Geometry - Phase Information (기하 위상 정보를 이용한 고속 영상 정합 기법)

  • Chong Min-Yeong;Oh Jae-Yong;Lee Chil-Woo;Bae Ki-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.9
    • /
    • pp.1195-1207
    • /
    • 2005
  • In this paper, we describe image matching techniques which is automatically retrieving the exact matching area using geometry-phase information. We proposed a Matching Method which is rapidly estimating the correspondent points between adjacent images that included big-rotation and top-bottom movement element. It is a method that reduce computation quantity to be required to find an exact correspondent position using geometry-phase information of extracted points in images and DT map which set the distance value among feature points and other points on the basis of each feature point of a image. The proposed method shows good performance especially in the part to search a exact correspondent position between adjacent images that included big-rotation and top-bottom movement element.

  • PDF

Development of Simulator for Evaluation Balance by Using Vestibuloocular Reflex (전정안구반사를 이용한 평형감각 평가용 시뮬레이터의 개발)

  • 임승관;김규겸;정호춘;진달복;김민선;박병림
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.157-162
    • /
    • 1997
  • The purpose of this study was to develop a sinusoidal rotatory chair systim for evaluating the vestibular function in patients suffered from vertigo with vestibualr disorders. The sinusoidal rotatory chair system is composed of a rotatory chair systim and softwares. Maximum velocity of the rotatiry chair was upto 60 degree per second and frequency range was 0.01 to 0.64 Hz. To evaluate the vestibular function in vertigo patients, vestibuloocular reflex was measured by sinusoidal rotation of the whole body about vertical axis in the darkness, and optokinetic nystagmus, visual vestibuloocular reflex , and visual supression test were also performed. Eye movement was measured by means of a electronystgmograph amplifier through Ag-AgCI surface electrodes. Gain, phase, and symmetry were obtained from analysis of the eye movement ineuced by vestibular or visual stimulation. In healthy adults, sinusoidal rotation of the shole body produced nystagmus, of which gain was directly proportional to the velocity of stimulation. The gain of visual vestibuloocular reflex or optokinetic nystagmus, and it was suppressed markedly by visual suppression test. These results suggest that the sinusoieal rotatory chair systim which was developed by this study can evaluate the vestibular function quantitatively, also this system is very useful to diagnose and to dstimate the vestibualr function during recovery from vertigo

  • PDF

CONSIDERATION OF THE ANTERIOR OPENBITE AND DEEP BITE IN CLASS III AND THEIR TREATMENT WITH MULTILOOP EDGEWISE ARCHWIRE (MEAW) (골격형 III급 전치개교와 과개교합에 대한 비교고찰 및 MEAW에 의한 치험예)

  • Baek, Seung-Hak;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.685-699
    • /
    • 1991
  • The purpose of this report is to review vertical dysplasia such as openbite or deep bite in skeletal Class III malocclusion and their treatment modality and to present two cases treated with MEAW. The results obtained were as follows A. Open bite case 1. The treatment time was 3 year 8 months. 2. Upper and lower incisors showed extrusion and especially lower anterior alveolar process showed remodelling. 3. The mesially inclined upper and lower molars were uprighted and especially lower first molars showed extrusion that means remodelling of alveolar bone. 4. Normal overbite and overjet were established. 5. Mandible showed slight clockwise rotation. 6. Maxilla showed slight downward bending of ANS part. 7. Upper lip showed downward drop and lower lip showed retraction and touch between upper and lower lip was established. 8. Tongue posture of post-treatment was more raised than pretreatment. B. Deep bite case 1. The treatment time was 1 year 8 months. 2. Upper incisors showed intrusion and labioversion and lower incisors showed slight intrusion and linguoversion. 3. The lower molars showed distal uprighting and intrusion and upper molars showed mesial movement and extrusion. 4. Normal overbite and overjet were established. 5. Maxilla did not show downward movement. 6. Mandible showed slight clockwise rotation. 7. Lower lip showed retraction and downward drop and upper lip showed downward drop.

  • PDF

Effectiveness of graded motor imagery in subjects with frozen shoulder: a pilot randomized controlled trial

  • Gurudut, Peeyoosha;Godse, Apurva Nitin
    • The Korean Journal of Pain
    • /
    • v.35 no.2
    • /
    • pp.152-159
    • /
    • 2022
  • Background: Subjects with frozen shoulder (FS) might not be comfortable with vigorous physical therapy. Clinical trials assessing the effect of graded motor imagery (GMI) in FS are lacking. The aim of this study was to determine the effect of GMI as an adjunct to conventional physiotherapy in individuals with painful FS. Methods: Twenty subjects aged 40-65 years having stage I and II of FS were randomly divided into two study groups. The conventional physiotherapy group (n = 10) received electrotherapy and exercises while the GMI group (n = 10) received GMI along with the conventional physiotherapy thrice a week for 3 weeks. Pre- (Session 1) and post- (Session 9) intervention analysis for flexion, abduction, and external rotation range of motion (ROM) using a universal goniometer, fear of movement using the fear avoidance belief questionnaire (FABQ), pain with the visual analogue scale, and functional disability using the shoulder pain and disability index (SPADI) was done by a blinded assessor. Results: Statistically significant difference was seen within both the groups for all the outcomes. In terms of increasing abduction ROM as well as reducing fear of movement, pain, and functional disability, the GMI group was significantly better than control group. However, both groups were equally effective for improving flexion and external rotation ROM. Conclusions: Addition of GMI to the conventional physiotherapy proved to be superior to conventional physiotherapy alone in terms of reducing pain, kinesiophobia, and improving shoulder function for stage I and II of FS.

Seven axis modular type pneumatic manipulator development (7축 모듈라형 공기압 매니퓰레이터 개발)

  • 김동수;김용채;김형의
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.968-973
    • /
    • 1991
  • Seven axis modular type pneumatic manipulator is composed of electro-pneumatic automation system which contributes to factory automation by performing loading & unloading process successively which is simple routine work of dealing item of machine tool, catapult, assembly machine, welding machine and so on. In this study, we obtained soft and quick movement in a large space and good reliability motion of various function by combining several actuators which perform rotation movement as well as linear movement at the same time. Gripper which apply to rotary sensor transmitted a structure to demanded position. This development item of 5kgf load prevent stick-slip phenomena of stroke end by designing high cushion internal. We develope flexible manipulator which conforms to demand of user by applying multiple sequence program.

  • PDF

A Study on The Formation of Inferior Space in Louis I. Kahn's Architecture (루이스 칸 건축의 내부공간 형성에 관한 연구)

  • Yoon, Dong-Sik
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.5
    • /
    • pp.23-30
    • /
    • 2008
  • This thesis aims to analyze the visual perceptual effects drawn by 'axial composition and divergence' and to interpret the architecture of Kahn in respect of 'axial composition and divergence'. Axial composition of the form, the location of the entrance and divergence of internal movement were checked up about 53 works by extracting parti which is basic element of spatial composition. The 3D modeling simulation was performed for the selected 10 works in order to analyze the visual perceptual effect due to divergence of the internal movement. The reaction of the observer's actions and visual perception by 'axial composition and divergence' is presented in the following steps. 1. Divergence of the entrance/a panorama of expanding planes. 2. Divergence of internal movement/The process of perception of visual rotation and central spatial form. 'Perceptive form' created by 'divergence' is the result of diverse and flexible series of processes which must be experienced in person in order to reach the space as a room with a definite domain and center.

Dynamic response of a HDD pivot ball bearing acted by Hertzian contact force (Hertzian contact force에 의한 HDD pivot ball bearing의 동적 반응 분석)

  • Yoon, Joo Young;Park, No-Cheol;Lim, Gunyeop;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.993-993
    • /
    • 2014
  • Increasing the density magnetic recording of a hard disk drive needs to improve position control of a slider. We have troubles analyzing position of a slider by nonlinear property of pivot ball bearing. Many researches analyze a hard disk drive to change pivot ball bearing part from balls to springs. Pivot ball bearing operates by rotation and movement of balls. This study considers Hertzian contact force when balls contact with outer race to analyze nonlinear movement of a ball bearing. Experiment of this study measures movement of a circular center of a pivot ball bearing. We also verify the simulation results and the experiment results.

  • PDF