• Title/Summary/Keyword: Rotation group

Search Result 706, Processing Time 0.029 seconds

Effects of Flexion-Extension of Stretching on Craniocervical (스트레칭 굴곡 신전이 두경부에 미치는 영향)

  • Jeon, Ho-Young;Jung, Hyun-Sung;Bae, Sung-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.1 no.1
    • /
    • pp.109-116
    • /
    • 2006
  • Purpose : To identify the effects of flexion-extension of stretching on the functional improvement of patients with neck myofascial pain syndrome. Methods : the present research investigated 30 patients with neck myofascial syndrome, dividing them into a group doing flexion-extension of stretching. This study examined degree of recovery from neck pain by comparing their neck myofascial pain syndrome before and after the treatment, and compared to find difference in the degree of recovery from myofascial pain syndrome. Results : The results are as follows. For the flexion of stretching, 1. For the visual analogue scale (VAS) decreased significantly for six weeks treatment, 2. For the flexion decreased significantly for six weeks treatment. and the range of motion of cervical vertebrae increased significantly(p>.05). 3. For Stretching, range of motion left rotation indicated significant difference after pre test and after two week but no significant difference after six week. 4. For the left rotation decreased significantly for six weeks treatment. and the range of motion of cervical vertebrae increased significantly(p>.05). 5. For the right rotation decreased significantly for six weeks treatment. and the range of motion of cervical vertebrae increased significantly(p>.05). Conclusion : This study suggest that flexion-extension of stretching have an effect on the functional improvement of patients with neck myofascial pain syndrome.

  • PDF

Research on rotation capacity of the new precast concrete assemble beam-column joints

  • Han, Chun;Li, Qingning;Wang, Xin;Jiang, Weishan;Li, Wei
    • Steel and Composite Structures
    • /
    • v.22 no.3
    • /
    • pp.613-625
    • /
    • 2016
  • The joints of the new prefabricated concrete assemble beam-column joints are put together by the hybrid joints of inserting steel under post-tensioned and non-prestressed force and both beams and columns adopt prefabricated components. The low cyclic loading test has been performed on seven test specimens of beam-column joints. Based on the experimental result, the rotation capacity of the joints is studied and the $M-{\theta}$ relation curve is obtained. According to Eurocode 3: Design of steel structures and based on the initial rotational stiffness, the joints are divided into three types; by equivalent bending-resistant stiffness to the precast beam, the equivalent modulus of elasticity $E_e$ is elicited with the superposition method; the beam length is figured out that satisfies the rigid joints and after meeting the requirements of application and safety, the new prefabricated concrete assemble beam-column joints can be regarded as the rigid joints; the design formula adopted by the standard of concrete joint classification is theoretically derived, thereby providing a theoretical basis for the new prefabricated concrete structure.

SMBH Mass Estimate Discrepancy and Its Origin of NGC 6861

  • Jang, Minsung;Owers, Matt
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.69.2-69.2
    • /
    • 2012
  • NGC 6861 is the brightest S0 galaxy in the Telescopium group. It has unusually high central stellar velocity dispersion (~400 km/s) and clear rotation (~250 km/s). Considering the well-known M-sigma relation, this large central dispersion implies that the central supermassive black hole (SMBH) has mass comparable to the most massive black holes in the Universe. However, the mass implied by the bulge luminosity-SMBH mass relation is an order of magnitude lower than that predicted by the M-sigma relation. In order to determine the origin of this inconsistency, we obtain integral field spectroscopy using the Wide Field Spectrograph (WiFeS) on the ANU 2.3m telescope. The data are used to map the velocity and velocity dispersion fields which show that our measurements are consistent with those from the other literature. The large field of view the WiFeS observations have allows us to map the kinematics of a much greater portion of NGC 6861 and reveals that the eastern part of the galaxy has higher velocity and dispersion than the rest of halo. We discuss the origin of the unusual fast rotation and the discrepancy of two SMBH mass estimations from three plausible perspectives: 1) the interaction between subgroups of NGC 6861 and its counterpart, NGC 6868; 2) the inhibited growth of the stellar bulge by the AGN activity which leads to an underestimate the SMBH mass when using the bulge luminosity-SMBH mass relation; and 3) gas rich minor mergers that could be crucial for increasing both rotation velocity and velocity dispersion during the evolution of NGC 6861.

  • PDF

Plantar Hypoesthesia Alters Gait Kinematics Pattern in Individuals with and without Chronic Ankle Instability (만성 발목 불안정성 환자군과 정상인 군의 발바닥 감각기능 저하에 따른 운동학적 보행 패턴의 변화)

  • Kang, Tae Kyu;Lee, Sae Yong;Lee, Inje;Kim, Byong Hun;Jeong, Hee Seong;Kim, Chang Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.2
    • /
    • pp.79-86
    • /
    • 2021
  • Objective: The purpose of this study was to identify the effect of reduced plantar cutaneous sensation on gait kinematics during walking with and without CAI. Method: A total of 20 subjects involved in this study and ten healthy subjects and 10 CAI subjects participated underwent ice-immersion of the plantar aspect of the feet before walking test in this study. The gait kinematics were measured before and after ice-immersion. Results: We observed a before ice-immersion on plantar cutaneous sensation, CAI subject were found to reduced ankle dorsiflexion, knee external rotation, hip adduction, and internal rotation compared to control subject. After ice-immersion, CAI subjects were found to reduce knee external rotation, hip adduction. However, no significant ankle joint kinematics. Conclusion: While walking, gait pattern differences were perceived between groups with and without plantar cutaneous sensation. The results of the study may explain the abductions in the hip angle movements in CAI patients at initial contact compared to healthy subjects in the control group when plantar cutaneous sensation was reduced. A change in proximal joint kinematics may be a conservative strategy to promote normal gait patterns in CAI patients.

Effect of Circumferential Tool Path Control on Friction Stir Spot Welding of Al/Fe Dissimilar Metal Joint (툴 경로제어를 이용한 Al/Fe 이종금속 마찰교반점용접 공정특성 평가)

  • Yoon, Jin Young;Kim, Cheolhee;Rhee, Sehun
    • Journal of Welding and Joining
    • /
    • v.34 no.3
    • /
    • pp.6-11
    • /
    • 2016
  • Joining Al/Fe dissimilar metals is becoming a subject of special interest in the assembly of automotive parts as a trade-off between the weight lightening and the cost reduction. Although various studies have been introduced to join Al alloy with the steel sheet by fusion welding, weak joint strength and galvanic corrosion still remained as problems to be solved. As a solid state welding, friction stir welding has been preferred to fusion welding processes in the dissimilar metal joints. This study investigated friction stir spot welding (FSSW) of Al alloy to the thin steel sheet with a thickness of 0.65 mm. The conventional FSSW is a stationary spot welding process but new approach adopted an additional circumferential movement in company with high speed tool rotation. A full factorial experimental design was implemented, and the main and interaction effects of parameters were analysed on the failure load in the tensile shear test. The direction and radius of rotation were statistically significant parameters and these two parameters affected the joint width and the shape of the hook.

The Biomechanical Correlation Analysis of Upper Body according to Forward Head Posture (머리전방자세에 따른 상체의 생체역학적 상관분석)

  • Jung, Yeon-Woo;Gong, Won-Tae;Kwon, Hyeok-Soo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.1-9
    • /
    • 2013
  • Background: The purpose of this study is to analysis of correlation upper body according to forward head posture. Methods: The subjects of this study were 40 female university students who were equally and randomly allocated to a forward head posture group, normal group. Using general posture system, electromyograph, visual analogue scale, tape measurement, neck disability index were evaluated. Results: There was positive correlation between posture analysis and Sternocleidomastoid, neck flexion (p<.05). There was positive correlation between Craniovertebral angle (CVA) and trapezius upper, VAS (p<.05). There was negative correlation between posture analysis and CVA (p<.05). There was negative correlation between Cranial rotation angle and CVA (p<.05). Conclusion: Increased forward head posture lead to increase of pain, muscles activity, so it suggests to be necessary on the prevention of dysfunction and limited activities daily living.

  • PDF

Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study

  • Gedrimiene, Agne;Adaskevicius, Rimas;Rutkunas, Vygandas
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.271-279
    • /
    • 2019
  • PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and distal implant scan bodies ($P{\leq}.05$). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.

Comparison of Kinematic Variables of the Club Head, Golf Ball and Body Alignment according to Swing Plane during Golf Driver Swing (골프 드라이버 스윙 시 스윙 플레인에 따른 클럽 헤드 및 골프볼의 운동학적 변인과 신체 정렬 변인의 비교 분석)

  • Young-Tae, Lim;Moon-Seok, Kwon;Jae-Woo, Lee
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.4
    • /
    • pp.147-152
    • /
    • 2022
  • Objective: The purpose of this study was to analyze the effects of club head and golf ball kinematics and body alignment according to the swing plane during golf driver swing. Method: Sixteen college golfers participated in this study. Kinematic data of the club head and golf ball were collected using golf swing analysis system (Trackman Ver. 3e). The body alignment variables were collected using 8 motion capture system. An Independent samples t-test was used for comparison between the Out-to-In group and In-to-Out group, and the statistical significance level was set at .05. Results: For the club head related variables, club path and club face angle showed higher values in Out-to-In swing plane than In-to-Out swing plane. For the kinematic variables of the golf ball, the total distance showed a higher value in the In-to-Out swing plane than that of the Out-to-In swing plane. For the body alignment, the In-to-Out swing plane showed higher values than the Out-to-In swing plane for the pelvis rotation angle and trunk rotation angle. Conclusion: This study suggest that it would be more effective to use the In-to-Out swing plane for increasing the total distance during the golf driver swing.

The Effects of the Range of Motion of Joint with Vibratory Stimulation of the Patients of Adhesive Capsulitis of the Shoulder (진동적용이 견관절 유착성관절낭염 환자의 관절가동범위에 미치는 영향)

  • Choi, Woohyuk;Lee, Jinhwan;Min, Dongki;Choi, Junhhee;Shin, Sohong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.1 no.2
    • /
    • pp.77-83
    • /
    • 2015
  • The purpose of this study is to prove the increase of range of motion of shoulder joint in the patients with shoulder adhesive capsulitis by applying the vibratory stimulation. In terms of subjects of the study, the experimental group 15(4 male, 11 female)and the control group 15(5 male, 10 female) were divided. The measurement of the shoulder range of motion was taken by measuring the degrees of flexion, abduction, and external rotation with a goniometer from pre treatment to one to four weeks. The results were as follows : In the experimental group and control group, there was the statistical significance in the range of motion of the shoulder flexion, abduction, and external rotation during four weeks. In summary, the vibratory stimulation are effective interventions for improving shoulder adhesive capsulitis, patient's range of motion of shoulder joint.

Comparison between Screw Fixation and Modified Tension Band Wiring for Medial Malleolar Fracture (족관절 내과 골절에 대한 금속나사고정술과 변형 긴장대고정술의 임상적 비교)

  • Ko, Sang-Hun;Park, Young-Jun;Jeong, You-Young;Kim, Woo-Suk
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.1
    • /
    • pp.54-59
    • /
    • 2002
  • Purpose: To compare the clinical results between the screw fixation and modified tension band wiring in the treatment of medial malleolar fracture. Materials and Methods: From September 1998 to April 2002, 52 patients were treated by screw fixation and 43 patients were treated by modified tension band wiring for medial malleolar fracture. Results: Accoding to Lauge- Hansen classification, there were 28 cases of supination-external rotation type (53.8%), 9 of supination-adduction type (17.3%), 8 of pronation -external rotation type (15.4 %), 7 of pronation -abduction type (13.5 %) in screw fixation group and 21 (48.9%),11 (25.6%), 7 (16.3%) 4 (9.3%) of each type in tension band wiring group. The average time to union was 15.7 weeks in screw fixation group and 12.8 weeks in tension band wiring group.(p<0.05) In the functional outcome (according to Meyer and Kumler), 29 patients treated (76.2 %) with screw fixation showed excellent results and 34 patients (86.6%) treated with tension band wiring had excellent results (p<0.05). Conclusion: We concluded that more satisfactory result could be obtained with modified tension band wiring compared with screw fixation in the treatment of the medial malleolar fracture.

  • PDF