• 제목/요약/키워드: Rotation degree

검색결과 388건 처리시간 0.017초

유한요소의 Normal rotation 연구 (The Finite element with Normal Rotational Degree Freedoms)

  • 조순보
    • 한국공간구조학회논문집
    • /
    • 제4권4호
    • /
    • pp.85-89
    • /
    • 2004
  • A frame element embedded normal to a shear wall or slab (shell element) is common in the structural systems. In that case there is a need for a membrane or shell element to have a normal rotation degree of freedom at each node in order to have a good result of stresses. Even if Many other people studied this area, All man, Cook and Sabir are representative investigators in this area. In this research paper, Sabir's methods of vertex rotation stiffness matrix in a membrane element are studied. New stiffness of vertex rotation are proposed by taking advantage of beam stiffness theory. Rectangular elements stiffness with rotational degree of freedom are compared in accuracy ratio each other.

  • PDF

운동자유도에 따른 어깨관절 굴곡각도의 변화 (The Change of Shoulder Flexion by Degree of Freedom in The Individuals)

  • 김태윤;최재원
    • PNF and Movement
    • /
    • 제7권1호
    • /
    • pp.25-32
    • /
    • 2009
  • Objective : The purpose of this study was conducted to find the change of shoulder flexion by degree of freedom between the Proprioceptive Neuromuscular Facilitation(PNF) pattern, the flexion- abduction- external rotation, and not PNF pattern, the flexion- exteral rotation(except abduction)movement. Method : PNF pattern applied on the unilateral upper extremity in all subjects were the flexion- abduction- external rotation, and not PNF pattern, and twenty-six normal subjects(13 male, 13 female) were tested by Cybex Norm Testing & Rehabilitation System. Results : PNF pattern showed significant increase of flexion than not PNF pattern, the flexion-exteral rotation(except abduction)movement, and also the female group was significantly increased than male group. Conclusion : The results suggested that the application of PNF pattern to the unilateral upper extremity had affected on the shoulder flexion by degree of freedom.

  • PDF

축 안정화 디자인이 상이한 토릭소프트콘택트렌즈의 회전 양상 차이 (Difference in Rotation Pattern of Toric Soft Contact Lenses with Different Axis Stabilization Design)

  • 박소현;김동연;최주희;변현영;김소라;박미정
    • 한국안광학회지
    • /
    • 제20권2호
    • /
    • pp.133-140
    • /
    • 2015
  • 목적: 본 연구에서는 축 안정화 디자인이 상이한 두 토릭소프트콘택트렌즈의 회전축과 회전량이 자세와 응시방향에 따라 달라지는 지를 알아보았다. 방법: 20~30대 52안을 대상으로, Lo-Torque$^{TM}$디자인 및 ASD 디자인(accelerated stabilized design) 토릭소프트콘택트렌즈를 피팅한 후 정면을 포함한 5가지 응시방향과 누운 자세에서의 회전량을 측정하였다. 결과: 정자세에서 정면 및 수직방향 응시 시 Lo-Torque$^{TM}$ 디자인 렌즈는 코쪽, ASD 디자인 렌즈는 귀쪽으로 회전하는 비율이 높은 것으로 나타났다. 수평방향 응시시에는 두 렌즈 모두 응시방향과 반대로 축회전이 일어났다. 위쪽을 응시할 때의 회전량이 가장 작았으며 코쪽을 응시할 때의 회전량이 가장 많았다. $5^{\circ}$ 이내의 회전량을 보인 경우는 정면과 수직방향을 응시할 때의 Lo-Torque$^{TM}$ 디자인 렌즈에서 더 많았으며, 수평방향 응시 시에는 ASD 디자인 렌즈에서 더 많았다. 또한, 누운 직후에는 Lo-Torque$^{TM}$ 디자인 렌즈의 회전량이 더 적었으나 1분 후에는 ASD 디자인 렌즈의 회전량이 더 적었다. 결론: 본 연구에서는 토릭소프트콘택트렌즈 착용 후 응시방향 및 자세에 의해 유발되는 축회전이 축 안정화 디자인에 따라 달라짐을 확인하였다.

횡방향으로 회전하는 90도 정사각 단면 곡덕트에서 발달하는 난류유동의 측정 (Measurement of Developing Turbulent Flows in a 90-Degree Square Bend with Spanwise Rotation)

  • 김동철;최영돈;이건휘
    • 대한기계학회논문집B
    • /
    • 제27권2호
    • /
    • pp.206-214
    • /
    • 2003
  • Mean flow and turbulence properties of developing turbulent flows in a 90 degree square bend with spanwise rotation were measured by a hot-wire anemometer. A slanted wire is rotated into 6 orientations and the voltage outputs from them are combined to obtain the mean velocity and Reynolds stress components. The combinative effects of the centrifugal and Coriolis forces due to the curvature and the rotation of bend on the mean motion and turbulence structures are investigated experimentally. Results show that the two body forces can either enhance or counteract each other depending on the flow direction in the bend.

탈수직축 회전자극을 이용한 자세조절기능의 평가 (Evaluation of Postural Control by Off-vertical Axis Rotation)

  • 김규겸;이태호;김주환;고종선;박병림
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1999년도 추계학술대회 논문집
    • /
    • pp.111-114
    • /
    • 1999
  • Off-vertical axis rotator was developed to differentiate each function of the canal and otolith in the vestibular system and evaluate subjective symptoms during postural change. Eye movement induced by various types of rotation was measured in normal subjects. Nystagmus with fast component corresponding to direction of rotation was occurred by sinusoidal earth vertical axis rotation, and the gain of eye movement in vestibuloocular reflex (VOR) was lower than in visual vestibuloocular reflex (VVOR) and higher than in visual fixed vestibuloocular reflex (VFX). Degree of dizziness was proportioned to degree of gain. off-vertical axis rotation was produced severe dizziness than earth vertical axis rotation. These results suggest stimulation of the otolith should be minimized to make a stable and pleasant condition in work and travel.

  • PDF

Rotational Stability of AcrySof Toric Intraocular Lens Over Time: Influence of Capsulorhexis Contraction

  • Kim, Joong Hee;Cho, Kyong Jin
    • Medical Lasers
    • /
    • 제9권1호
    • /
    • pp.44-50
    • /
    • 2020
  • Background and Objectives To evaluate the rotational stability of AcrySof toric intraocular lenses (IOL) by considering lapse of postoperative time and influence of capsulorhexis contraction. Materials and Methods A prospective, masked, single center study was conducted on 19 patients who had undergone microcoaxial cataract surgery and AcrySof toric IOL implantation. Slit-lamp retroillumination photographs of anterior segments were obtained from all patients after 1 week, 1 month and 3 months post-surgery. The degree of alteration of the postoperative IOL axis alignment and the amount of anterior capsular shrinkage were analyzed using Adobe Photoshop software. Results The mean degree of toric IOL axis misalignment was 2.18 (±20.2) degrees at 3 months follow-up. Quadrant analysis of the capsulorhexis aperture area at 1 week and 1 month post-operative, showed counterclockwise IOL rotation when the capsule contraction was dominant in the haptic part as well as clockwise rotation when dominant in the non-haptic part (p = 0.015). Conclusion The direction and degree of AcrySof toric IOL rotation differed throughout the follow-up period. Since most misalignments were found on the first post-operative day, physicians should try to minimize peri-operative risk factors that influence IOL rotation. There was also a correlation between the part of anterior capsule contraction and the direction of IOL rotation.

관절과 상완 관절의 회전운동이 견갑흉곽 운동에 미치는 영향 (The Influence of the Glenohumeral Rotation on the Scapulothoracic Motion)

  • 서중배;최의성;원중희;김용민;이호승;김응록
    • Clinics in Shoulder and Elbow
    • /
    • 제1권2호
    • /
    • pp.186-192
    • /
    • 1998
  • This study was performed to evaluate the influences of the passive glenohumeral rotation on the scapulothoracic motion. We took anteroposterior radiograms of the right shoulders including the thoracic vertebrae with supine position in 10 normal male adults, at 0 degree abduction, 45 degrees abduction and 90 degrees abduction in scapular plane and in neutral rotation, maximal internal rotation and maximal external rotation in each abduction view. The scapulothoracic motion was measured as the distances between the vertical line drawn from the spinous process of the 7th cervical vertebra and the inferior and superior angles of the right scapula respectively. At 0 degree abduction, the distances were not changed in internal rotation relative to neutral rotation, but decreased significantly in external rotation, that is, the scapula shifts medially on external rotation. At 45 degrees abduction, the distances were increased significantly only in internal rotation, that is, the scapula shifts laterally on internal rotation. At 90 degrees abduction, the scapula rotated laterally on internal rotation and medially on external rotation. In conclusion, when a physician examines the rotation of the shoulder joint, he cannot exclude the scapulothoracic motion just by examining the patient with supine position. And we concluded that the rotatory movement of the shoulder is not solely contributed to the glenohumeral motion.

  • PDF

POSITIVELY EQUICONTINUOUS FLOWS ARE TOPOLOGICALLY CONJUGATE TO ROTATION FLOWS

  • Bae, Jong-Sook;Min, Kyung-Jin;Sung, Duk-Hyon;Yang, Seung-Kab
    • 대한수학회보
    • /
    • 제36권4호
    • /
    • pp.707-716
    • /
    • 1999
  • In this pater we study the continuity of rotation numbers of liftings of circle maps with degree one. And apply our result to prove that a positively equicontinuous flow of homeomorphisms on the circle $S^1$ is topologically conjugate to a continuous flow of rotation maps.

  • PDF

Moleciular Reorientation in the Presence of the Extended Diffusion of internal Rotation in Liquid Perdeuterotoluene

  • Doo-Soo Chung;Myung-Soo Kim;Jo-Woong Lee;Kook-Joe Shin
    • Bulletin of the Korean Chemical Society
    • /
    • 제4권1호
    • /
    • pp.25-28
    • /
    • 1983
  • The effect of internal rotation of methyl group in liquid perdeuterotoluene on nuclear quadrupole relaxation of methyl deuterons is investigated. A model of a spherical diffusor undergoing rotational diffusion is extended to include the extended diffusion of internal rotation. The overall reorientational correlation time in the presence of internal rotation is explicitly given as an analytical function of the angular momentum correlation time. Also, the degree of inertial effect in the internal rotation is evaluated.

Isomed 2000을 이용한 고등학교 테니스 선수 서브동작의 어깨관절 회전력과 근동원 양상 분석 (An Analysis of Shoulder Joint Torque and Muscle Pattern Duing Tennis Serve by Isokinetic Motions on Isomed 2000)

  • 김성섭;김의환;성영호;김태완;정재욱
    • 한국운동역학회지
    • /
    • 제17권1호
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to analyze the shoulder joint torque and muscle pattern performing as Tennis serve by Isokinetic motions on Isomed 2000. The subject, who was 5 males Korean national high school tennis players. By analyzing the flexion/extension of the shoulder, the peak torque of the internal/external rotation motion(at 60,180 and 300 degree/sec) at peak torque degree, the weight, peak torque, and power. combined with the timing of the electrode of the attached trapezius and posterior deltoid at the three part. From the data analysis & discussion the following conclusions were drawn. When doing a shoulder extension, the peak torque can be widely seen at 60degree per second. However the degree may be different depending on angular velocity. When doing an internal rotation at 90degree abduction, peak torque per weight was seen at 60degree per second. The degree of peak torque was at 31.6-44.2 and peak power was faster when angular velocity was increased. The aspect of muscle pattern was seen more at the internal rotation in the 90degree abduction rather than the shoulder extension. However the angular velocity was not influenced by muscle mobilization(in order of anterior deltoid, posterior deltoid and trapezius. To properly apply the above conclusion, when tennis players serve it is better the elbow be impacted by the extension. when doing isokinetic motion it is better to increase angular velocity and improve muscle power. also the anterior deltoid amongst the shoulder muscle should be improved to develop serve speed.