• 제목/요약/키워드: Rotating collimator

검색결과 10건 처리시간 0.023초

초점길이 및 왜곡수차 측정장치 제작 (Fabrication of the focal length and distortion measurement system)

  • 조현모
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.82-86
    • /
    • 1990
  • A camera type optical bench system equipped with a lens collimator and an image analyzer is fabricated to measure the equivalent focal length and distortion of lenses. This system is automatized by the computer which controls stepping motors. A nodal slide optical bench system equipped with an off axis reflective collimator is fabricated and improved by using rotating arms and air bearing system. distortion measurement on a wide angle lens using the camera method and the nodal slide method is reported. Defocusing error in the distortion measurement with the nodal slide optical bench is analyzed and improved by iteration method to search the correct image point.

  • PDF

RMC를 이용한 미지 선원의 방향, 거리 예측 (Estimating the Direction and Distance of an Unknown Radiation Source Using RMC)

  • 신영준;김기현;이계민
    • 전자공학회논문지
    • /
    • 제53권9호
    • /
    • pp.118-125
    • /
    • 2016
  • 방사능 누출 사고 시 대응이나 핵안보 검증을 위한 핵물질 탐지에 있어서, 방사선을 방출하는 미지의 선원에 대한 위치 정보를 파악하는 것은 중요하다. 그러한 기구 중 하나인 회전 변조 시준기는 미지 선원을 원격 감지하기 위한 장비로서 영상화를 통해 선원의 위치 탐지가 가능하다. 본 논문에서는 Kowash의 연구를 기초로 회전 변조 시준기의 시스템 모델과 그를 영상화하는 알고리즘을 소개한다. 하지만 결과 영상화 이미지는 선원의 방향은 보여줄 수 있으나 선원의 거리를 찾지 못하는 문제점이 있다. 또한 선원의 실제 방향뿐 아니라 $180^{\circ}$ 대칭방향에서도 선원을 추정하는 모호성 문제를 안고 있다. 본 논문에서 우리는 영상화 결과의 방향 대칭적 모호성을 해결하고, 두 대의 RMC를 이용해 거리를 추정하는 방법을 제안한다. 그리고 이를 RMC 시뮬레이션 데이터를 이용하여 성능을 검증한다.

회전형 콜리메이터 기반 방사능 오염원의 방향탐지 기법 (Direction detection technique of radioactive contaminants based on rotating collimator)

  • 황영관;송근영;이남호
    • 한국정보통신학회논문지
    • /
    • 제24권11호
    • /
    • pp.1519-1527
    • /
    • 2020
  • 일반적인 방사선 측정장치는 방사능 오염원에 대한 선량률을 측정하는 공간 선량률 탐지 장치와 방사능 오염정보에 대한 2차원 또는 3차원 영상화 장치의 형태로 개발되었다. 이러한 방사선 계측 기법은 각각의 장단점을 가지고 있으나 방사능 사고 지역에서 인명피해를 최소화하며, 빠른 제염을 위해서는 두 가지 탐지 장치의 장점이 모두 필요하다. 방사능 오염원으로부터 방사능 피해를 최소화하기 위해서는 방출되는 방사선에 대한 선량률 뿐만 아니라 어디에서 방출되고 있는지를 빠르게 확인해야 하기 때문이다. 본 논문에서는 방사능 오염원 탐지를 위한 검출 센서와 회전체, 방향성을 갖는 콜리메이터를 이용하여 방사능 오염원에 대한 선량률 및 방향 정보를 실시간으로 측정 할 수 있는 기법을 고안하였다. 회전형 기반의 방사능 탐지 장치는 탐지 센서를 둘러싼 회전체가 회전하며 개구부와 일치할 때 획득되는 방사능 정보와 회전체의 위치정보를 통해 선량률과 방향을 확인할 수 있도록 구성하였으며, 다수개의 홀을 통해 수직, 수평 방향에 대한 측정 기법을 제안하였다. 탐지 결과 수평 방향에서의 탐지 시 방향 정보에 대한 측정오차는 1% 미만으로 확인하였다.

Frequency Swept Laser at 1300 nm Using a Wavelength Scanning Filter Based on a Rotating Slit Disk

  • Jeon, Man-Sik;Jung, Un-Sang;Song, Jae-Won;Kim, Jee-Hyun;Oh, Jung-Hwan;Eom, Jin-Seob;Kim, Chang-Seok;Park, Young-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.330-334
    • /
    • 2009
  • A simple and compact frequency swept laser is demonstrated at $1.3{\mu}m$ using a wavelength scanning filter based on a rotating slit disk. The laser is comprised of a pigtailed semiconductor optical amplifier, a circulator, and a wavelength scanning filter in an extended cavity configuration. The wavelength scanning filter is composed of a collimator, a diffraction grating, a rotating slit disk, and a mirror. The instantaneous laser output power is more than 5 mW. The scanning range of the laser is extended to 80 nm at the maximum level, and 55 nm in the full width at half maximum at a scanning rate of 2 kHz.

Pin Power Distribution Determined by Analyzing the Rotational Gamma Scanning Data of HANARO Fuel Bundle

  • Lee, Jae-Yun;Park, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.452-461
    • /
    • 1998
  • The pin power distribution is determined by analyzing the rotational gamma scanning data for 36 element fuel bundle of HANARO. A fission monitor of Nb$^{95}$ is chosen by considering the criteria of the half-life, fission yield, emitting ${\gamma}$-ray energy and probability. The ${\gamma}$-ray spectra were measured in Korea Atomic Energy Research Institute(KAERI) by using a HPGe detector and by rotating the fuel bundle at steps of 10$^{\circ}$. The counting rates of Nb$^{95}$ 766 keV ${\gamma}$-rays are determined by analyzing the full absorption peak in the spectra. A 36$\times$36 response matrix is obtained from calculating the contribution of each rod at every scanning angle by assuming 2-dimensional and parallel beam approximations for the measuring geometry. In terms of the measured counting rates and the calculated response matrix, an inverse problem is set up for the unknown distribution of activity concentrations of pins. To select a suitable solving method, the performances of three direct methods and the iterative least-square method are tested by solving simulation examples. The final solution is obtained by using the iterative least-square method that shows a good stability. The influences of detection error, step size of rotation and the collimator width are discussed on the accuracy of the numerical solution. Hence an improvement in the accuracy of the solution is proposed by reducing the collimator width of the scanning arrangement.

  • PDF

$^{99m}Tc$용 콜리메타의 성능과 SPECT 화상의 영향 (Comparison of SPECT Images with $^{99m}Tc$ Collimators)

  • 이만구;이정옥;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권2호
    • /
    • pp.35-40
    • /
    • 2001
  • Performance of SPECT imaging systems which use a rotating gamma camera, are affected by characteristics of the detector-collimator assembly, the data acquisition method, and the filter used in imaging reconstruction. The purpose of this study Is to examine image qualifies of SPECT with different types of low energy collimators. The SPECT imaging system in this study is a digital gamma camera system GCA-901A(Toshiba) and a data processing unit Scintipac-700(Shimadzu). The four types of collimators compared are UHR(ultra high resolution), LEHR(low energy high resolution), LEGP(low energy general purpose), and I-123 PAR(Parallel), with 0.27, 0.66, 1.00, and 2.06 relative sensitivity, respectively. In this case of the same collimators, the spatial resolutions measured in the slice plane showed a slight difference in the FWHM values(mean values of UHR, LEHR, LEGP, and I-123 PAR were 11.3 mm, 13.6 mm, 15.8 mm, and 20.4 mm, respectively) between the center and the circumference of the field of view, in the radial direction, but a large difference in the tangential direction, with lower FWHM values(values of UHR, LEHR, LEGP, and I-123 PAR were 8.4 mm, 8.7 mm, 9.3 mm, and 10.8 mm at 12 cm from the center, respectively). In comparison of SPECT images with the four types of collimators, except for the I-123 PAR collimator, image qualities of UHR, LEHR, and LEGP collimators showed only a slight difference. From the point of for, it is expected that the LEGP collimator would be suitable for SPECT imaging with $^{99m}Tc$.

  • PDF

유방암 환자의 삼문 조사 시 내외측 접면 조사야의 Posterior Edge의 어긋남의 교정 (Correction Method on Mismatched Posterior Edge of Medial and Lateral Tangential Fields for Three Fields Techniques in Breast Cancer)

  • 김헌정;노준규;김우철;박성용
    • Radiation Oncology Journal
    • /
    • 제21권2호
    • /
    • pp.174-181
    • /
    • 2003
  • 목적: 유방암 환자를 삼문으로 방사선치료할 경우 유방의 접면 영역과 쇄골상 영역의 기하학적 일치를 이루기 위해 갠트리를 회전한 상태에서 테이블을 회전하는 방법이 사용되며, 이때 접면 조사의 posterior edge에 발생할 수 있는 어긋남을 필름선량측정법과 삼차원입체조영치료계획을 통하여 확인하고, 그 어긋남의 해결방법으로 콜리메이터의 각도를 보정해주는 방법들을 연구하였다. 대상 및 방법: 어긋남의 보정을 위해 쇄골상 영역과 유방의 접면 영역을 반쪽 빔 블록과 tangential field block을 사용하여 모의치료한 후 테이블 회전을 하지 않은 상태에서 환자의 몸에 접면 빔의 posterior edge에 선을 긋고, 테이블을 회전시킨 상태에서의 광조사야의 posterior edge와 테이블 회전 이전에 환자의 몸에 그어 놓은 선과 일치되도록 콜리메이터를 회전시키는 방법과, 본 연구에서 고안한 방법인 삼각함수로부터 유도시킨 다음과 같은 공식에 따라 콜리메이터를 회전하여 posterior edge의 어긋남을 보정하고 두 방법을 비교하였다. Co=$2sin^{-1}${$sin\{theta}\{cdot}sin(C/2)$} (Co: collimator angle, $\theta$: angle between tangential beam and table, C: couch angle) 결과: 필름선량측정법을 이용하여 콜리메이터를 보정하지 않은 경우 내외측의 접면 빔의 posterior edge가 어긋남을 확인할 수 있었으며, 콜리메이터를 보정함으로써 posterior edge의 일치함을 확인할 수 있었다. 위 두 방법에서 콜리메이터의 회전 각도는 동일하였다. 또한 전산화된 삼차원입체조영치료계획을 통하여, 접면 빔의 posterior edge의 어긋남을 확인할 수 있었으며, 콜리메이터를 회전하여 보정 함으로써 posterior edge의 일치를 확인할 수 있었다. 각각의 선량체적표를 비교할 경우, 콜리메이터를 보정하여 posterior edge의 일치를 이룬 경우가 더 적은 용적의 폐가 조사되는 것을 확인할 수 있었다. 결론: 유방암 환자의 방사선 치료에서 삼문으로 치료할 경우에 갠트리와 테이블을 동시에 회전하여 쇄골위 영역의 아래 면과 접면 빔의 윗면을 일치시킬 때 각각의 접면 빔의 posterior edge가 어긋남을 인지해야 하며, 약간의 콜리메이터를 회전시킴으로써 이 어긋남은 보정가능하고, 폐에 조사되는 방사선 양도 줄일 수 있었다.

Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가 (Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator)

  • 김중현;이재성;김진수;이병일;김수미;정인순;김유경;이원우;김상은;정준기;이명철;이동수
    • 대한핵의학회지
    • /
    • 제39권6호
    • /
    • pp.445-455
    • /
    • 2005
  • 목적 : 임상용 Philips ARGUS 감마카메라와 특별 제작한 작은 구경의 바늘구멍조준기를 이용하여 animal SPECT를 개발하였다. 본 연구에서는 이 시스템의 물리적인 성능을 평가하고 소동물 실험에 적합한지를 평가하였다. 대상 및 방법: 스텝 모터와 이를 제어할 수 있는 소프트웨어를 이용한 피사체 회전장치를 개발하였다. 작은 입구(0.5, 1.0, 2.0 mm)의 바늘구멍조준기를 제작하였고 평면 공간해상도, 민감도, 단층촬영해상도 등을 포함한 물리적 성능을 모든 입구 크기에 대해 실험하였다. 조준기 입구로부터의 거리에 따른 사용 가능한 시야를 측정하기 위하여, 같은 간격만큼 떨어진 여러 선선원의 영상을 얻고 영상의 시야 내에서 보이는 선 영상의 개수를 이용하여 사용 가능한 시야를 측정하였다. 시야의 정중앙에 놓인 내경 0.5 mm, 길이 12 mm의 Tc-99m 선선원을 이용하여 거리에 따른 평면 공간 해상도를 측정하였다. 전체 반값두께를 'mm'단위로 얻기 위한 환산인자를 평면 영상에서의 두개의 서로 떨어진 선선원으로부터 계산하였다. 시스템 민감도를 측정하기 위하여 내경 1.0 mm의 Tc-99m 점선원을 사용하였다. 또한 냉소반점 모형과 열소반점 모형, 그리고 [I-123] FP-CIT를 정맥내 주사한 흰쥐의 뇌 영상의 SPECT 영상을 얻었고 여과후역투사 방법으로 재구성하였다. 결과: 사용 가능한 시야의 크기는 조준기의 초점으로부터의 거리에 비례하였고 이들의 관계는 선형 함수로 근사되었다(y=1.4x+0.5). 3 cm에서 1.0 mm 조준기로 측정한 민감도와 평면해상도는 각각 71 cps/MBq과 1.24 mm이었다. 1.0 mm 바늘구멍조준기에 대하여 [I-123] FP-CIT를 이용한 흰쥐의 뇌 SPECT 영상에서 각 반구의 줄무늬체 도파민 전달체 분포가 잘 구분되어 보였다. 결론: Philips ARGUS 스캐너와 작은 구경의 바늘구멍조준기로 개발한 새로운 소동물 SPECT 시스템이 소동물 영상을 얻는데 충분한 성능을 가짐을 입증하였다.

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

후방산란 엑스선 영상획득을 위한 다채널 검출기 개발 (Development of Multi-channel Detector of X-ray Backscatter Imaging)

  • 이정희;박종원;최영철;임창휘;이상헌;박재흥
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.245-247
    • /
    • 2022
  • 엑스선 후방산란 영상획득기술은 물체에서 산란되는 엑스선을 활용하여 피조사체 내부 영상을 획득할 수 있는 기술로 영상획득을 위해서는 시스템은 엑스선 발생장치와 산란 엑스선을 측정하기 위한 검출시스템을 포함하여야 한다. 엑스선 후방산란 영상획득장치는 고속으로 회전하는 회전 콜리메이터를 통해 생성되는 엑스선을 샘플링 간격으로 실시간 신호를 획득하여야 하며 이를 위해서는 고속 신호획득장치가 요구된다. 우리는 후방산란 영상획득장치를 위해 대면적 플라스틱 섬광체(500×600×50mm3)와 광증배관으로 구성된 후방산란 엑스선 획득용 센서부에서 생성되는 신호의 변환 및 전달하기 위한 고속 다채널 신호획득장치를 개발하였다. 개발한 후방산란 영상획득용 검출시스템은 최소 15u초 간격으로 신호의 획득이 가능하며 최대 6채널의 신호의 변환 및 전달이 가능한 시스템으로 고속 후방산란 엑스선 영상획득이 가능하다. 개발된 검출시스템은 개별 센서의 보정을 위한 전압, 신호이득, 저레벨 제거 등의 원격 조절 기능을 포함한다. 현재 우리는 다양한 조건에서 엑스선 후방산란 영상획득을 적용 시험을 수행하고 있다.

  • PDF