• Title/Summary/Keyword: Rotating Curved Duct

Search Result 28, Processing Time 0.023 seconds

Measurement of Outward Turbulent Flows Subject to Plane Rate of Strain in a Rotating 90 Deg. Curved Duct of Variable Cross-Section (단순변형률 조건 하의 회전하는 가변단면 $90^{\circ}$ 곡덕트내 외향 난류유동 측정)

  • Oh, Chang-Min;Choi, Young-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.623-631
    • /
    • 2000
  • Hot-wire measurements were carried out on the developing turbulent flows subject to plane rate of strain in a rotating curved duct. The cross-section of the curved duct varies from 100mm${\times}$50mm rectangular shape at the bend inlet gradually to the 50mm${\times}$100mm rectangular shape at the bend outlet. Experimental setup consists of the test section of $90^{\circ}$ curved duct, rotating disc of 1.95m diameter, Ag-Ni precision slip ring, automatic traversing mechanism, variable speed motor, centrifugal blower, orifice flowmeter and hot-wire anemometer. Data signals from the rotating curved duct are transmitted through the slip ring to the computer which is located at the outside of the rotating disc. 3-dimensional velocity and 6 Reynold stresses components were obtained from the fluctuating and mean voltage measured by the slant type hot-wire probe rotating into 6 orientations. We investigate the effects of Coriolis and centrifugal forces on the turbulence structure.

Numerical Simulation of Turbulent Flows Under a Plane Rate of Strain Condition in a Rotating $90^{\circ}$ Curved Duct (평면변형율 조건 하의 회전하는 $90^{\circ}$ 곡덕트 내 난류유동의 전산해석)

  • Kwon, Hyung-Joong;An, Jung-Soo;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.485-490
    • /
    • 2000
  • The effect of curvature, rotation, variable cross-section can make very complex flow pattern in turbo-machinery such as Pumps, compressors, turbines, In this study of turbulent flow characteristics rotating $90^{\circ}$ curved duct under a Plane rate of strain condition is computationally analyzed. The objective of this study is to understand the complex turbulent flow phenomena in turbo-machinery passage by analyzing the modeled rotating $90^{\circ}$ curved duct flow. RSM(Reynolds Stress Model) was employed for the turbulence modeling of Reynolds stress in momentum equations proposed by Shin(1995). The three dimensional computational code which adopts RSM for trubulence modeling was newly developed for the generalized curvilinear coordinate.

  • PDF

A Numerical Study on the Similarity of the Developing Laminar Flows between in Orthogonally Rotating Square Duct and Stationary Curved Square Duct (수직축을 중심으로 회전하는 직관과 정지한 곡관 내부의 발달하는 층류 유동의 유사성에 관한 수치적 연구)

  • Lee G. H.;Baek J. H.
    • Journal of computational fluids engineering
    • /
    • v.6 no.1
    • /
    • pp.21-30
    • /
    • 2001
  • A numerical study on the similarity of the developing laminar flows between in a straight duct rotating about an axis perpendicular to that of the duct and in a stationary curved duct was carried out. In order to clarify the analogy of two flows, dimensionless parameters K/sub LR/ = Re/(equation omitted) and Rossby number, Ro, in a rotating straight duct were used as a set corresponding to Dean number K/sub LC/ = Re/(equation omitted), and curvature ratio, λ, in a stationary curved duct. For the large values of Ro and λ, it is shown that the flow field satisfies the 'asymptotic invariance property', that is, there are strong quantitative similarities between the two flows such as flow patterns, friction factors, and maximum axial velocity magnitudes for the same values of K/sub LR/ and K/sub LC/ if they are correlated with dimensionless axial distances Z/sub R/ = z/(equation omitted) for a rotating duct flow and Z/sub C/ = z/(equation omitted) for a stationary curved duct flow.

  • PDF

Study on the Similarity of Flows in an Orthogonally Rotating Square Duct and a Stationary Curved Square Duct (수직축을 중심으로 회전하는 직관과 정지한 곡관내의 유동 유사성에 관한 연구)

  • Lee, Gong-Hee;Baek, Je-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.825-830
    • /
    • 2001
  • A numerical study on a quantitative analogy of the fully developed flow between in a straight square duct rotating about an axis perpendicular to that of the duct and a stationary curved duct of square cross-section is carried out. In order to clarify the similarity of two turbulent flows, the dimensionless parameters $K_{TR} = Re^{1/4}/\sqrt{Ro}$ and the Rossby number, Ro, in a rotating straight duct flow were used as a set corresponding to $K_{TC} = Re^{1/4}/\sqrt{{\lambda}}$ and curvature ratio, ${\lambda}$, in a stationary curved duct flow so that they have the same dynamical meaning as $K_{LR} = Re/\sqrt{Ro}$ and $K_{LC} = Re/\sqrt{{\lambda}}$ of the fully developed laminar flows. For the large values of Ro or A, it is shown that the flow field satisfies the asymptotic invariance property: there are strong quantitative similarities between the two flows such as flow patterns and friction factors for the same values of $K_L$ and $K_T$.

  • PDF

Study on the Similarity of Laminar Flows between in Orthogonally Rotating Square Duct and Stationary Curved Squared Duct (수직축을 중심으로 회전하는 직관과 정지한 곡관내에서의 층류 유동의 유사성 비교)

  • Lee, Gong-Hui;Baek, Je-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1683-1691
    • /
    • 2000
  • In this study, it is numerically revealed that the secondary flow due to the Coriolls force in a straight duct rotating about an axis perpendicular to that of the duct is analogous to that caused by the centrifugal force in a stationary curved duct. Dimensionless parameters $K_{LR}=Re/\sqrt{Ro}$ and Rossby number in a rotating straight duct were used as a set corresponding to Dean number and curvature ratio in a stationary curved duct. When the value of Rossby number and curvature ratio is large, it is shown that the flow field satisfies the `asymptotic invariance property`, that is, there are strong quantitative similarities between the two flows such as friction factors, flow patterns, and maximum axial velocity magnitudes for the same values of $K_{LR}$ and Dean number.

Numerical Study on the Similarity between the Fully Developed Turbulent Flow in an Orthogonally Rotating Square Duct and that in a Stationary Curved Square Duct (수직축을 중심으로 회전하는 직관과 정지한 곡관 내에서의 완전 발달된 난류 유동의 유사성에 관한 수치적 연구)

  • Lee, Gong-Hui;Baek, Je-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.731-740
    • /
    • 2001
  • A numerical study on the quantitative analogy between the fully developed turbulent flow in a straight square duct rotating about an axis perpendicular to that of the duct and that in a stationary curved duct of square cross-section is carried out. In order to clarify the similarity of the two flows, dimensionless parameters K(sub)TR=Re(sup)1/4/√Ro and Rossby number, Ro, in a rotating straight duct flow were used as a set corresponding to K(sub)TC=Re(sup)1/4/√λ and curvature ratio, λ, in a stationary curved duct flow so that they have the same dynamical meaning as those of the fully developed laminar flows. For the large values of Ro or λ, it is shown that the flow field satisfies the asymptotic invariance property, that is, there are strong quantitative similarities between the two flows such as flow patterns and friction factors for the same values of K(sub)TR and K(sub)TC.

A Study on Unsteady Flow measurement using Laser Doppler Velocimeter in Curved Duct (곡관에서 laser유속계를 이용한 비정상유동 계측에 대한 연구)

  • 조병기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.81-89
    • /
    • 1996
  • In the present study, the unsteady in a square-selctional 180.deg. curved duct are experimentally investigated. The experimental study using air in a square-sectional 180.deg. curved duct is carried out to measure axial velocity distributions with data acquisition and processing system. In this system, Rotating Machinery Resolver(RMR) and PHASE Software are used to obtain the results of unsteady flows. In conclusion, the exact measurement of unsteady flow using LDV system depends upon uniformity of metreials, duct thickness, and scattered particles.

  • PDF

A Study on Characteristics of Unsteady Laminar Flows in Squaresectional $180^{\circ}$ Curved Duct (정사각단면 $180^{\circ}$ 곡관덕트의 입구영역에서 비정상층류유동의 유동특성에 관한 연구)

  • Park, G.M.;Mo, Y.W.;Cho, B.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.515-524
    • /
    • 1996
  • The flow characteristics of developing unsteady laminar flow in a square-sectional $180^{\circ}$ curved duct are experimentally investigated by using laser doppler velocimerty (LDV) system with data acquisition and processing system of rotating machinery resolver(RMR) and PHASE software. The major flow characteristics of developing laminar pulsating flows are presented by mean velocity profilel velocity distribution of secondary flow, wall shear stress distributions, entrance lengths according to dimensionless angular frequency($\omega^+$), velocity amplitude ratio($A^1$), and time-averaged Dean number($De_ta$). The velocity profiles and wall shear stress distribution of laminar pulsating flow with dimensionlessangular frequency show the flow characteristics of the quasi-steady laminar flow in a curved duct. The developing region of laminar pulsatile flows in a square-sectional $180^{\circ}$ curved duct is extended to the curved duct angle of approximately $120^{\circ}$ under the present experimental condition.

  • PDF

A Numerical Study on the Similarity of Laminar Flows in Orthogonally Rotating Rectangular Ducts and Stationary Curved Rectangular Ducts of Arbitrary Aspect Ratio (임의의 종횡비를 가지는 수직축을 중심으로 회전하는 직관과 정지한 고고간 내부의 층류 유동의 유사성에 관한 수치적 연구)

  • Lee, Gong-Hee;Baek, Je-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.842-849
    • /
    • 2002
  • The present study showed that a quantitative analogy of the fully developed laminar flows inorthogonally rotating rectangular ducts and stationary curved rectangular ducts of arbitrary aspect ratio could be established. In order to clarify the similarity of the two flows, the dimensionless parameters $K_{LR}$ =Re/√Ro and Rossby number Ro= $w_{m}$/$\Omega$d in a rotating strait duct were used as a set corresponding to Dean number $K_{LC}$ =Re/√λand curvature ratio λ=R/d in a stationary curved duct. Under the condition that the value of Rossby number and curvature ratio was large enough, the flow field satisfied the ‘asymptotic invariance property’: there were strong quantitative similarities between the two flows such as friction factors, flow patterns, and maximum axial velocity magnitudes for the same values of $K_{LR}$ and $K_{LC}$ .

Flows Characteristics of Developing Turbulent Pulsating Flows in a curved Square Duct (곡관덕트내의 입구영역에서 난류 맥동유도의 유동특성)

  • 봉태근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.533-542
    • /
    • 1999
  • In this study the flow characteristics of developing turbulent pulsating flows in a square-sec-tional 180。 curved duct are investigated experimentally. The experimental study of air flow in a square-sectional curved duct is carried out to measure axial velocity distribution secondary flow velocity profiles and wall shear stress distributions by using a Laser Doppler Velocimetry system with the data acquisition and processing system of Rotating Machinery Resolver (RMR) and PHASE software at the entrance region of the duct which is divided into 7 sections from the inlet(${{\o}}=0_{\circ}$) to the outlet (${{\o}}=180_{\circ}$) in $30_{\circ}$ intervals. The results obtained from the study are summarized as follows: (1) The time-averaged critical Dean number of turbulent pulsating flow(De ta, cr) is greater than $75{\omega}+$ It is understood that the critical Dean number and the critical Reynolds number are related to the dimensionless angular frequency in a curved duct. (2) Axial velocity profiles of turbulent pulsating flows are of an annular type similar to those of turbulent stead flows. (3) Secondary flows of trubulent pulsating flows are strong and complex at the entrance region. As velocity amplitudes(A1) become larger secondary flows become stronger. (4) Wall shear stress distributions of turbulent pulsating flows in a square-sectional $180_{\circ}$ curved duct are exposed variously in the outer wall and are stabilized in the inner wall without regard to the phase angle.

  • PDF