CT법을 이용한 진원도 측정 방법의 개선에 관한 연구 (A Study on the Improvement of Circularity Measurement Using Circular Test Method)

  • 주만식
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.446-451
    • /
    • 1999
  • A study for the roundness of machining center is classified into two ways. one is the way that progresses the roundness amending the parameter of machining center based on the measured value after the measurement of the roundness of machining center by means of a existing measuring device, another is the way that measures the roundness by remodeling the existing measuring device. The former is studied by pack hei jae team in Seoul university, the latter is studied by TSUTSUMI. Especially TSUTSUMI measures the roundness according to circular compensation after the insertion of developed measuring desire using a rotary encoder to the spindle of machining tool. We study how regulation velocity occuring with circular motion of machining center table influences the roundness after measuring the roundness using Circular Test method by a 2 dimention probe and a standard discus in this experiment.

  • PDF

CT법을 이용한 진원도 및 직각도 측정에 관한 연구 (A Study on the Measurement of Circularity and Perpendicularity Using Circular Test Method)

  • 주만식
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.75-81
    • /
    • 2000
  • This study for the roundness and perpendicularity of machining center is classified into two ways. One is the way that progresses the roundness amending the parameter of machining center based on the measured value after the measurement of the roundness of machaning center by means of a existing measuring device, another is the way that measures the roundness by remodeling the existing measuring device. the former is studied by pack hei jae team in Seoul university, the later is studied by TSUTSUMI. Especially TSUTSUMI measures the roundness according to circular compensation after the insertion of developed measuring device using a rotary encoder to the spindle of machining tool. we study how regulation velocity occuring with circular motion of machining center table influences the roundness after measuring the roundness using Circular Test method by a 2 dimention probe and a standard discus in this experiment.

  • PDF

비대칭 양단고정 포물선 아치의 자유진동에 관한 연구 (Free vibration analysis of unsymmetric parabolic arches with fixed ends)

  • 이병구
    • 한국농공학회지
    • /
    • 제28권1호
    • /
    • pp.68-74
    • /
    • 1986
  • The governing differential equations and the boundary conditions for the free vibra- tion of the unsymmetric parabolic arch with fixed ends are derived on the basis of the equilibrium equations and the D'Alembert principle. The effect of the rotary inertia as well as the extensional and the flexural deformations is considered in the governing differential equations. A trial eigenvalue method is used for determining the natural frequencies. The Ru- uge-Kutta method is used in this method to perform the integration of the differential equations. The detailed studies are made of the lowest three vibration frequencies for the par- abolic chord length equal to 10m. The effect of the rotary inertia is analyzed and it's numerical data are presented in table. And as the numerical results the frequency versus the rise of arch and the radius of gyration are presented in figures.

  • PDF

NC 선반의 동적이송오차에 관한 연구

  • 여인완;박철우;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.641-645
    • /
    • 1996
  • Ball screws are used in the feeding system for transmission of driving force. The friction effect between bed and table, which can affect in accuracyin one dimension feeding and describe the dynamic feeding error, could be simplified as a specific model through experiments. The experiments for dynamic feeding errors were performed om tje NC lathe eith a ball screw. The errors in feeding were measured with respect to the variances of feed, spindle speed and motor current for feeding. A rotary encoder and a current sensor were installed with NC lathe.

  • PDF

고속 위치제어계의 강인 $H_\infty$ 제어 (Robust $H_\infty$ Control of High-Speed Positioning Systems)

  • 최진택;김종식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 춘계학술대회 논문집
    • /
    • pp.342-347
    • /
    • 1995
  • Loop shaping $H_{\infty}$control with normalized coprime factorization was applied to a servo-motor driven high-speed powitioning system. The high-gain controller was designed to attenuate the postion errors caused byfriction effects and extermal disturbances. The non-existence of limit cycle was analyzed, though there is actuator saturation. The designed $H_{\infty}$control system was experimently tested in a rotary index table. Results showed its effectiveness to improve postion accuracy with out any compensation scheme for friction, and robustness to model perturbation and external disturbances.ces.

  • PDF

동작시간분석에 의한 작업개선연구 -PCB조립작업을 사례로- (A Work Improvement Study by Motion-Time Analysis)

  • 박성학
    • 기술사
    • /
    • 제16권3호
    • /
    • pp.33-40
    • /
    • 1983
  • This paper is one of the case studies to improve the labor productivity of PCB assembly through Work Factor motion-time analysis and the application of the motion economy principles and the human factors engineering theory. In result, we can improve 129% of the labor productivity by using a rotary table for the parts delivery. Therefore, it is expected that this result can be used for a lot of the manual works of the small and medium-sized industries especially.

  • PDF

다공질정압공기 Bearing을 이용한 고정도 회전 Table의 성능 (The Performance of High-Precision Rotary Table Using Externally Pressurized Porous Gas Bearing)

  • 한응교;김기중
    • 한국정밀공학회지
    • /
    • 제1권2호
    • /
    • pp.47-57
    • /
    • 1984
  • The porous matterials are used both to control the flow of the compressed gas and to serve as the bearing surface. This porous design offers several advantages over the conventional externally pressurized gas bearings. It can simplify the construction, lower the gas consumption, and make the cleaning of the gas supply less critical. Test apparatus was cinstructed to experi- mentally investigate maximum load capacity of thrust bearing was measured 200 Kg (15Kg/$\mu$m), and radial bearing was 36 Kg/$\mu$m. And a rotation accuracy of face waving was 0.0127$\mu$m, and center waving was measured 0.5 $\mu$m. Finally, the use of this method of design and manufacturing will contribute to many practical application in the field required for precision and high stability.

  • PDF

5축 CO2 레이저 컷팅 머신 및 CAM 시스템 개발 (Development of 5-axis $CO_2$ Laser Cutting Machine and CAM)

  • 강재관;염경섭;강병수;이홍주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.245-246
    • /
    • 2006
  • For developing 5-axis laser cutting systems, many problems such as rotating of laser head or table, 5-axis tool path generation and collision avoidance between laser head and product should be solved. In this paper, a five-axis laser cutting machine with table swivel and rotary type configuration is developed. The five axes (X,Y,Z,A,B) are controlled and interfaced to PC via MMC board. Two kinds of CAM S/W such as commercial 5-axis CAM S/W(Euclid) and UG-API are engaged to generate NC code for the developed 5-axis laser cutting machine.

  • PDF

眞圓度 測定器의 誤差特性에 대한 解析 -위상차법- (An Analysis of Performance Error of Roundness Measuring Instrument -by phase different method-)

  • 한응교;허문석;박익근
    • 오토저널
    • /
    • 제10권3호
    • /
    • pp.31-37
    • /
    • 1988
  • A phase different method to evaluate the instrument error of roundness measuring instrument and the form error of specimens for the calibration of the instrument is used. An instrument with a rotary table supported by an air bearing was calibrated by using the standard balls as a standard. The calibration was carried out repeatedly by setting the same ball in 12 phase angles(per 30.deg.) on the table and by recording their roundness errors with a magnification of 100,000 times. As a result of data analysis of all the observations, readout at each of 144 orientations(per 2.5.deg.) from recorded data file, the error of performance of the instrument and the specimens are separated. In the particular instrument used in the present experiment, the error of the instrument was determined with the accuracy of 0.0164 (.mu.m) and the form error of the specimens was determined with the accuracy of 0.0264,0.0172(.mu.m), respectively. If the instrument was calibrated by using the above specimens, then the accuracy of the measurement of roundness error can be improved to about 0.017 (.mu.m).