• Title/Summary/Keyword: Room resonance

Search Result 187, Processing Time 0.034 seconds

1H-NMR Analysis according to the Storage Period after the Use of Iopamidol and Ioversol Formulations Contrast Agents (Iopamidol과 Ioversol 제제 조영제의 사용 후 보관 기간에 따른 1H-NMR 분석)

  • Han, Beom-Hee
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.239-245
    • /
    • 2021
  • Since the side effects of contrast agents occur in many ways, hospitals must clearly identify the contrast agents and know how to manage them. Storage of contrast media It is common practice to store contrast media in a warm room to reduce viscosity and improve patient comfort. However, it is important to recognize that long-term storage at high temperatures can shorten the shelf life of a product. Therefore, in this study, the presence or absence of chemical changes according to the storage period after using the contrast medium was analyzed. As the analysis equipment, a 500 MHz Nuclear Magnetic Resonance Spectrometer of Bruker Avance (Germany) possessed by Korea Basic Science Institute (KOREA BASIC SCIENCE INSTITUTE; KBSI) was used. For the X-ray iodide contrast medium, Pamiray contrast medium of Iopamidol and Optiray contrast medium of Ioversol, samples remaining after 7 days, 20 days, 30 days, and 1 year were collected, By acquiring the spectrum from the 1H-NMR spectrometer of the contrast medium stimulated by It was compared and analyzed with the standard sample. In conclusion, depending on the storage period of the contrast medium, no peaks of physical and chemical changes were observed in both the Pamiray contrast medium of Iopamidol and the Optiray contrast medium of Ioversol after 7 days, 20 days, 30 days, and 1 year after use.

FORMULATION AND STABILITY TEST OF ANTIAGING CREAM CONTAINING METHANOL FRACTION OIL OF PANGIUM EDULE.REINW. AS A RADICAL SCAVENGER AGENT

  • Djajadisastra, J.;Anwar, E.;Milani, E.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.303-306
    • /
    • 2003
  • Indonesia is a tropical country having a temperature range of 25-35$^{\circ}C$ which can affect the skin and causes damages like aging. This aging process is due, at least, to free radical reactions. For this reason, many attempts had been done to find out creams containing natural antioxidant compound which have a potential of free radical scavenger. Kluwek, a fermented form of foot ball fruit or picung (Pangium edule.Reinw), had been proved to contain antioxidant compound in its methanol fraction oil to which antiaging cream was formulated. Stability evaluation was conducted for cream with Kluwek oil compared to base cream, including organoleptic (colour and odour), pH, viscosity, particle size, centrifugation test and flow characteristics either in room temperature (27$^{\circ}C$) or stress condition (4$^{\circ}C$ and 5$0^{\circ}C$) for 8 weeks continuously, and six times cycling test at 4$^{\circ}C$ and 5$0^{\circ}C$ every 24 hours. The results showed that cream with Kluwek oil and base cream were stable at temperature 27 and 4$^{\circ}C$, cycling test and centrifugation test, but not stable at 5$0^{\circ}C$. Free radical evaluation was done by Electron Spin Resonance and the result showed that cream with Kluwek oil had less free radicals compared to base cream.

  • PDF

Effect of Deposition Temperature on the Characteristics of Low Dielectric Fluorinated Amorphous Carbon Thin Films (증착온도가 저유전 a-C:F 박막의 특성에 미치는 영향)

  • Park, Jeong-Won;Yang, Sung-Hoon;Park, Jong-Wan
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1211-1215
    • /
    • 1999
  • Fluorinated amorphous carbon (a-C:F) films were prepared by an electron cyclotron resonance chemical vapor deposition (ECRCVD) system using a gas mixture of $C_2F_6$ and $CH_4$ over a range of deposition temperature (room temperature ~ 300$^{\circ}C$). 500$^{\AA}C$ thick DLC films were pre-deposited on Si substrate to improve the strength between substrate and a-C:F film. The chemical bonding structure, chemical composition, surface roughness and dielectric constant of a-C:F films deposited by varying the deposition temperature were studied with a variety of techniques, such as Fourier transform infrared spectroscopy(FTIR), X-ray photoelectron spectroscopy(XPS), atomic force microscopy (AFM) and capacitance-voltage(C-V) measurement. Both deposition rate and fluorine content decreased linearly with increasing deposition temperature. As the deposition temperature increased from room temperature to 300$^{\circ}C$, the fluorine concentration decreased from 53.9at.% down to 41.0at.%. The dielectric constant increased from 2.45 to 2.71 with increasing the deposition temperature from room temperature to 300$^{\circ}C$. The film shrinkage was reduced with increasing deposition temperature. This results ascribed by the increased crosslinking in the films at the higher deposition temperature.

  • PDF

Prediction Model for unfavorable Outcome in Spontaneous Intracerebral Hemorrhage Based on Machine Learning

  • Shengli Li;Jianan Zhang;Xiaoqun Hou;Yongyi Wang;Tong Li;Zhiming Xu;Feng Chen;Yong Zhou;Weimin Wang;Mingxing Liu
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.1
    • /
    • pp.94-102
    • /
    • 2024
  • Objective : The spontaneous intracerebral hemorrhage (ICH) remains a significant cause of mortality and morbidity throughout the world. The purpose of this retrospective study is to develop multiple models for predicting ICH outcomes using machine learning (ML). Methods : Between January 2014 and October 2021, we included ICH patients identified by computed tomography or magnetic resonance imaging and treated with surgery. At the 6-month check-up, outcomes were assessed using the modified Rankin Scale. In this study, four ML models, including Support Vector Machine (SVM), Decision Tree C5.0, Artificial Neural Network, Logistic Regression were used to build ICH prediction models. In order to evaluate the reliability and the ML models, we calculated the area under the receiver operating characteristic curve (AUC), specificity, sensitivity, accuracy, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR). Results : We identified 71 patients who had favorable outcomes and 156 who had unfavorable outcomes. The results showed that the SVM model achieved the best comprehensive prediction efficiency. For the SVM model, the AUC, accuracy, specificity, sensitivity, PLR, NLR, and DOR were 0.91, 0.92, 0.92, 0.93, 11.63, 0.076, and 153.03, respectively. For the SVM model, we found the importance value of time to operating room (TOR) was higher significantly than other variables. Conclusion : The analysis of clinical reliability showed that the SVM model achieved the best comprehensive prediction efficiency and the importance value of TOR was higher significantly than other variables.

Single Centre Experience on Decision Making for Mechanical Thrombectomy Based on Single-Phase CT Angiography by Including NCCT and Maximum Intensity Projection Images - A Comparison with Magnetic Resonance Imaging after Non-Contrast CT

  • Kim, Myeong Soo;Kim, Gi Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.188-201
    • /
    • 2020
  • Objective : The purpose of this study was to suggest that computed tomography angiography (CTA) is valuable as the only preliminary examination for mechanical thrombectomy (MT). MT after single examination of CTA including noncontrast computed tomography (NCCT) and maximum intensity projection (MIP) improves door-to-puncture time as well as results in favorable outcomes. Methods : A total of 157 patients who underwent MT at Dong Kang Medical Center from April 2015 to March 2019 were divided into two groups based on the examination performed prior to MT : CTA group who underwent CTA with NCCT and MIP, and NCCT+magnetic resonance image (MRi) group who underwent MRI including perfusion images after NCCT. In the two groups, time to CTA imaging or NCCT+MRi imaging after symptom onset, and time to arterial puncture and reperfusion were characterized as time-related outcomes. The evaluation of vascular recanalization after MT was defined as a modified thrombolysis in cerebral infarction (mTICI) scale. National Institutes of Health Stroke Scale (NIHSS) was assessed at the time of the visit to the emergency room and modified Rankin Scale (mRS) was assessed after 90 days. Results : Typically, there were 34 patients in the CTA group and 33 patients in the NCCT+MRi group. A significantly shorter delay for door-to-puncture time was observed (mean, 86±22.1 vs. 176±47.5 minutes; <0.01). Also, a significantly shorter door-to-imege time in the CTA group was observed (mean, 13±6.8 vs. 93±30.8 minutes; p<0.01). Moreover, a significantly shorter onset-to-puncture time was observed (mean, 195±128.0 vs. 314±157.6 minutes; p<0.01). Reperfusion result of mTICI ≥2b was 100% (34/34) in the CTA group and 94% (31/33) in the NCCT+MRi group, and mTICI 3 in 74% (25/34) in the CTA group and 73% (24/33) in the NCCT+MRi group. Favorable functional outcomes (mRS score ≤2 at 90 days) were 68% (23/34) in the CTA group and 60% (20/33) in the NCCT+MRi group. Conclusion : A single-phase CTA including NCCT and MIP images was performed as a single preliminary examination, which led to a reduction in the time of the procedure and resulted in good results of prognosis. Consequently, it is concluded that this method is of sufficient value as the only preliminary examination for decision making.

Effects of Residual Solvents in the Phase Transition, Transition Enthalpy, and Transition Temperature of Phospholipid Membranes (잔류 유기 용매가 모델 세포 지질막의 상전이, 상전이 엔탈피 및 상전이 온도에 미치는 영향)

  • An, Eun Seol;Choi, Jae Sun;Lee, Dong Kuk
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Lipid membranes composed of phosphatidylcholine (PC) are used in biophysical study to mimic cellular membranes and interactions between the membrane and chemicals, where organics solvents are used in dissolving lipids or chemicals. Later, solvents are removed from the solution under nitrogen gas at room temperature, followed by the further removal of the solvent at vacuum condition for several hours. In this process, some solvents are easily removed under described conditions above and others are required more severe conditions. In this study, $^{31}P$ solid-state nuclear magnetic resonance (SSNMR) techniques and differential scanning calorimetry (DSC) were used to see any changes in the line shapes of $^{31}P$ NMR spectra of multilamellar vesicles (MLVs) samples of POPC and in the phase change temperature of multilamellar vesicles (MLVs) of DPPC in DSC thermogram with or without any residual solvents. The thermodynamic parameters associated with the solvents did exhibit noticeable changes depending on solvent types. Thus, it is concluded that solvents should be carefully chosen and removed completely and experimental results should also be interpreted with caution particularly for the experiments investigating lipid phase changes and related topics.

Synthesis of Naphthalimidopropyl Acrylate and GMA Copolymers and Their Physical Properties (나프탈이미도프로필 아크릴레이트와 GMA 공중합체의 합성과 물성)

  • Lim, Deok Jum;Oh, Seung Min;Kim, Boo Yoon;Park, Jae Kyung;Kang, Inn-Kyu;Seo, Kwan-Ho;Oh, Dae Hee
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.535-543
    • /
    • 2014
  • This work, which was about the synthesis of naphthalimidopropyl acrylate and GMA copolymers and their physical properties, investigated the compositions of the copolymer, the reactivity ratios of the monomer, resonance effect (Q), polar effect (e) and fluorescence of naphthalene. Azobisisobutyronitronitryl (AIBN) as an initiator was employed at $60^{\circ}C$ with dimethylformamide (DMF) of solvent for the copolymerization of NIPA. $r_1$ was found to be higher than $r_2$ from the reactivity ratios of the monomer obtained from Fineman-Ross (F-R), Kelen-$T{\ddot{u}}d{\ddot{o}}s$(K-T) methods. NIPA was found to be more copolymerized than GMA. $r_1{\cdot}r_2$ product was lower than 1, copolymerization was maked random-alternating type. The fluorescence spectrum of these polymers showed a weak monomer fluorescence band at 380 nm and a strong excimer fluorescence band at about 460 nm. Fluorescence life time of NIPA monomer showed fluorescence cover with UV 355 nm at room temperature, and life time showed $5.1449{\times}10^{-7}s$.

Copper(II) Sorption Mechanism on Kaolinite : An EPR and EXAFS Study (캐올리나이트 표면에서의 구리 수착 메카니즘 : 전자상자성공명 및 EXAFS 연구)

  • Sung Pil Hyun;Kim F Hayes
    • Journal of the Mineralogical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Copper(II) sorbed on kaolinite (KGa-lb) was studied using electron paramagnetic resonance (EPR) and extended X-ray absorption fine structure (EXAFS) spectroscopy. The sorbed copper(II) had an isotropic EPR signal with $g_{iso}\;=\;2.19$ at room temperature. At 77 K, the isotropic signal converted to an axially symmetric anisotropic signal with $g_{\$\mid$}\;=\;2.40,\;g_{\bot}\;=\;2.08,\;and\;A_{\$\mid$}\;=\;131\;G$. These EPR results suggest that the sorbed copper(II) forms an outer-sphere surface complex with a tetragonally distorted $CuO_{6}$ octahedral structure on the kaolinite. In the sorption measurement, the amount of sorbed copper increased with increasing pH of the solution. However, the intensity of the isotropic EPR line was not directly proportional to the amount of sorbed copper. This discrepancy was resolved by assuming the formation of a surface precipitate at higher pH that is invisible by EPR. The EXAFS data confirmed the existence of the surface precipitate. The best fit for the EXAFS of the sorbed copper showed that each copper on the kaolinite had 6.8 copper neighbors located $3.08\;{\AA}$ from it, in addition to the first shell oxygen neighbors, including 4 equatorial O at $1.96\;{\AA}$ and 2 axial O at $2.31\;{\AA}$. This work shows that the local environment of the copper sorbed on the kaolinite changes as a function of pH and surface loading, and that the EPR and EXAFS are useful in studying such changes.

Tubular Type Direct Methanol Fuel Cell for in situ NMR Diagnosis (In Situ NMR 진단용 원통형 직접 메탄올 연료전지)

  • Joh, Han-Ik;Um, Myung-Sup;Han, Kee-Sung;Han, Oc-Hee;Ha, Heung-Yong;Kim, Soo-Kil
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.4
    • /
    • pp.329-334
    • /
    • 2009
  • This study is to develop a fuel cell system applicable to an in situ NMR (Nuclear magnetic resonance) diagnosis. The in situ NMR can be used in real time monitoring of various reactions occurring in the fuel cell, such as oxidation of fuel, reduction of oxygen, transport phenomena, and component degradation. The fuel cell for this purpose is, however, to be operated in a specifically designed tubular shape toroid cavity detector (TCD), which constrains the fuel cell to have a tubular shape. This may cause difficulties in effective mass transport of reactants/products and uniform distribution of assembly pressure. Therefore, a new flow field designed in a particular way is necessary to enhance the mass transport in the tubular fuel cell. In this study, a tubular-shaped close-type flow field made of non-magnetic material is developed. With this flow field, oxygen is effectively delivered to the cathode surface and the produced water is readily removed from the membrane-electrode assembly to prevent flooding. The resulting DMFC (direct methanol fuel cell) outperforms the open-type flow field and exhibits $36\;mW/cm^2$ even at room temperature.

Thermal Stability of CaMgSi2O6:Eu2+ Phosphor by EPR Measurement (EPR 측정에 의한 CaMgSi2O6:Eu2+ 형광체의 열적 안정성 연구)

  • Heo, Kyoung-Chan;Kim, Yong-Il;Ryu, Kwon-Sang;Moon, Byung-Kee
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.4
    • /
    • pp.246-249
    • /
    • 2005
  • The blue-color emitting phosphor powder, $CaMgSi_{2}O_6:Eu^{2+}(CMS:Eu^{2+})$ was synthesized by the solid-state reaction method. The synthesized powder was annealed from room temperature to $1,100^{\circ}C$ in air. Its PL property and valence state of Eu atoms was measured by the photoluminescence (PL) and the electron paramagnetic resonance (EPR) spectrometers, respectively. The PL intensity was stable to $700^{\circ}C$, but drastically decreased to $1,100^{\circ}C$. The behavior of EPR intensity was very similar to the PL intensity. The EPR measurement showed that decreased intensity of the PL was caused to the oxidation from the ion $Eu^{2+}$ to $Eu^{3+}$ ions. The EPR spectrometer was powerful as a tool that could distinguish between the valence states of Eu atom as a dopant in various phosphors.