• 제목/요약/키워드: Room dimension

검색결과 106건 처리시간 0.026초

판형 종이 재질 전열교환 소자의 장기 성능 변화에 대한 실험적 연구 (An Experimental Study on the Long-Term Performance Variation of the Plate-Type Enthalpy Exchange Element Made of Paper)

  • 김내현
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.165-170
    • /
    • 2016
  • Long-term performance of the enthalpy exchange element is a topic of current interest due to the concern of possible performance degradation over time. In this study, a 350 CMH enthalpy recovery ventilator equipped with an enthalpy exchange element was installed in an office room, and the performance has been traced over the past 5 years. The appearance, overall dimension, thermal performance, leakage ratio and anti-bacterial performance were checked annually. Results showed that the change in thermal performance (sensible, latent and enthalpy efficiency) was negligible with periodic cleaning with an air gun. However, the leakage ratio increased with time, measuring 7.3% after 5 years. Anti-bacterial test revealed that no bacteria were found during the test period. The largest change in the dimension occurred at the middle location of the element, although the change was less than 2% of the initial value.

대학가 원룸촌 외부공간의 생활안전 기능요소에 관한 연구 -충청북도 소재 'O' 대학교 원룸촌 사례를 중심으로- (A Study on the elements of Life Safety Environment in the exterior Space of the University neighborhood One-room village -Focused on the case of 'O' university neighborhood One-room village in Chungcheongbukdo-)

  • 김환식
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.321-331
    • /
    • 2018
  • 본 연구는 거주자의 생활안전도를 연구하기 위한 기초 단계로서, 대학교 인근 원룸촌을 대상으로 거주자 의식조사 및 현장조사 등을 통해 대학가 원룸촌의 생활안전요소를 도출하고, 문제점 및 해결방향을 건축계획적 차원에서 다음과 같이 제시하였다. 첫째, 선행연구 결과 거주공간의 진입로 등 넓은 범위의 외부공간에 대한 생활안전 관련 연구나 실제 제도는 상대적으로 미흡하였다. 의식조사 결과, 거주공간의 생활안전 환경에 가장 심리적 영향을 미치는 요소는 보행로와 같은 외부공간의 환경이 거주지의 생활안전성에 가장 큰 영향을 미치는 것으로 나타났다. 둘째, 거주지 외부공간의 생활안전 기능요소는 건축 계획적 차원에서 크게 거주자 감시, 동선유도와 영역 구분, 외부의 공적 공간 활용, 쾌적한 환경 유지 등의 4개 유형으로 분류할 수 있으며, 이러한 요소는 건물 진입 공간뿐만 아니라 보행로나 기타 오픈스페이스 등 보다 넓은 범위의 공간에도 적용될 수 있다. 셋째, 대학가 원룸촌의 외부공간을 조사 분석한 결과, 보행로 같은 외부공간의 생활안전 환경이 거주인구와 원룸 건축물이 가장 많은 구역에서 매우 열악한 것으로 나타났다.

아파트 평면형상에 따른 바닥판의 동특성 해석 (Dynamic analysis of the floor structures with different floor plans in apartments)

  • 유승엽;이평직;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1459-1462
    • /
    • 2007
  • In this study, vibration characteristics of concrete slab were investigated through FEM analysis. Four different floor plans with the floor area of $100{\sim}130m^2$ were chosen to be analyzed. Boundary conditions of two dimensional finite element models were determined based on the modal test results. Results showed that mode shapes were formed somewhat different according to the floor plan and the contribution of 1st mode on the floor vibration is generally the highest. Through the transient analysis, it was also found that floor plan, expecially connection of the living room with the kitchen, affected the vibration acceleration levels.

  • PDF

안전성 기반 ODLM(LDT) 설치를 위한 SSI 네트워크 규모 결정 (Decision of SSI Network dimension for Safety based ODLM(LDT) installation)

  • 민근홍;이종우
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.797-802
    • /
    • 2008
  • High Speed Rail Train Control System consists of CTC, IXL and ATC. IXL and ATC perform train control and command via interchanging relevant information between a signal room and CTC. However, it is proved that IXL and ATC are attributed to train delay error since those systems are highly sensitive to trackside conditions. Especially, network error on IXL blocks transmitting signal information to adjacent signal room so that its effects give rise to system overall problems. In order to figure out the measures for which minimizing the occurrence rate of train delay error due to HSR TCS, This paper is performed analysis on communication network structure, the length of SSI network roof and SSI-TFM distance by examining and analyzing the error cases related to IXL in a network aspect.

GaAs MESFET의 최대 트랜스컨덕턴스를 위한 고온특성 (High Temperature Characteristics of GaAs MESFETs for Maximum Transconductance)

  • 원창섭;김영태;한득영;안형근
    • 한국전기전자재료학회논문지
    • /
    • 제14권4호
    • /
    • pp.274-280
    • /
    • 2001
  • This paper presents transconductance (g$\_$m/( characteristics of GaAs MESFET's at high temperatures ranging from room temperature to 350$\^{C}$. GaAs MESFET of 0.3x750[㎛] gate dimension has been used to obtain the experimental data. Gate to source voltage(V$\_$GS/) has been controlled to obtain the temperature dependent characteristics for maximum transconductance g$\_$mmax/ of the device. Furthermore g$\_$mmax/ and expected g$\_$m/ have been traced with temperatures ranging from room temperature to 350$\^{C}$ also by compensating for C$\_$GS/ to maintain the optimum operation of the device. From the results, V$\_$GS/decreases as the operating temperature increases for optimum operation of the transconductance. Finally V$\_$GS/ has been optimized to trace g$\_$mmax/ and enhances the decreased g$\_$m/ with different temperatures.

  • PDF

Alignment of transmitters in indoor visible light communication for flat channel characteristics

  • Curuk, Selva Muratoglu
    • ETRI Journal
    • /
    • 제44권1호
    • /
    • pp.125-134
    • /
    • 2022
  • Visible light communication (VLC) systems incorporate ambient lighting and wireless data transmission, and the experienced channel in indoor VLC is a major topic that should be examined for reliable communication. In this study, it is realized that multiple transmitters in classical alignment are the forceful factors for channel characteristics. In the frequency band, fluctuations with sudden drops are observed, where the fluctuation shape is related to the source layout and receiver location. These varying frequency-selective channels need solutions, especially for mobile users, because sustained channel estimation and equalization are necessary as the receiver changes its location. It is proven that using light-emitting diodes (LEDs) with highly directional beams as sources or using a detector with a narrow field of view (FOV) in the receiver may help partially alleviate the problem; the frequency selectivity of the channel reduces in some regions of the room. For flat fading channel characteristics all over the room, LEDs should be aligned in hexagonal cellular structure, and detector FOV should be arranged according to the cell dimension outcomes.

중환자실 병상주변공간의 면적과 간격에 관한 연구 (A Study on the Area and Clearances around Patient Bed Space in Intensive Care Unit)

  • 이현진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.47-55
    • /
    • 2019
  • Purpose: This study tries to propose the dimensions and area related to patient bed and surroundings in ICU considering nurses' observation and medical care. Methods: Literature survey, 11 Case studies, some Interviews with nurses and measuring of medical equipments' dimension in ICU have been mobilized in order to deepen the ICU bed area standards. Results: 0.3m clearance between head wall and patient bed is necessary for emergency cases. The minimum distance at the foot of the bed should not be less than 0.9m for EMR cart and medical tray. The clear floor area of one bed and surroundings in open ward is $10.2m^2(3m{\times}3.4m)$. In a single-bed patient room, the minimum clear floor area is $16.0m^2(4m{\times}4m)$. Considering the control of cross infection in ICU, Single bed patient room is recommended. Implications: The result of this study can be applied to the design of ICU and legislation of ICU standard.

양방향 설정온도 제어에 따른 지중연계 히트펌프 시스템의 에너지 절감량 평가 연구 (Two Way Set Temperature Control Impact Study on Ground Coupled Heat Pump System Energy Saving)

  • 강은철;이의준;민경천
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권2호
    • /
    • pp.7-12
    • /
    • 2014
  • Government has recently restricted heating and cooling set temperatures for the commercial and public buildings due to increasing national energy consumption. The goal of this paper is to visualize a future two way indoor set temperature control impact on building energy consumption by using TRNSYS simulation modeling. The building was modelled based on the twin test cell with the same dimension. Air source ground coupled heat pump performance data has been used for modeling by TRNSYS 17. Daejeon weather data has been used from Korea Solar Energy Society. The heating set temperature in the reference room is $24^{\circ}C$ as well as the target room set temperature are $23^{\circ}C$, $22^{\circ}C$, $21^{\circ}C$ and $20^{\circ}C$. The cooling set temperature of the reference room is also $24^{\circ}C$ as well as the target room set temperature of $25^{\circ}C$, $26^{\circ}C$, $27^{\circ}C$ and $28^{\circ}C$. For the air source heat pump system, heating season energy consumption is $35.52kWh/m^2y$ in the reference room. But the heating energy consumption in the target room is reduced to 7.5% whenever the set temperature decreased every $1^{\circ}C$. The cooling energy consumption in the reference room is $4.57kWh/m^2y$. On the other hand, the energy consumption in the target room is reduced to 22% whenever the set temperature increased every $1^{\circ}C$ by two way controller. For the geothermal heat pump system, heating energy consumption in the reference room is reduced to 20.7%. The target room heating energy consumption is reduced to 32.6% when the set temperature is $22^{\circ}C$. The energy consumption in the target room is reduced to 59.5% when the set temperature is $26^{\circ}C$.

청취자가 이동이 가능한 청각 디스플레이 시스템 개발 (A development of the virtual auditory display system that allows listeners to move in a 3D space)

  • 강대기;이채봉
    • 융합신호처리학회논문지
    • /
    • 제13권1호
    • /
    • pp.1-5
    • /
    • 2012
  • 본 연구에서는 청취자가 3차원 공간에서 자유로이 움직일 수 있는 음장 재생 시스템을 개발하였다. 시스템은 방음실($4.7m(W){\times}2.8m(D){\times}3.0m(H)$)에 설치하였으며 개인용 컴퓨터, 음의 제시장치 그리고 3차원 초음파 센서로 구성하였다. 본 시스템에서는 실내 전체를 감지하는 3차원 초음파 센서로부터 청취자의 위치 정보 및 자세각 정보를 얻어, 컴퓨터에서 나오는 음신호에 머리전달함수(HRTFs)를 삽입하여 음의 제시 장치로부터 출력하도록 설정하였다. 실험에 사용한 머리전달함수는 청취자의 머리 정변에서 1.5m 떨어진 지점에서 각각 측정하였다. 그리고 시스템의 성능을 평가하기 위해 가상 음원의 위치를 랜덤으로 변화시키고, 청취자에게는 자유로운 이동을 허락한 상태에서 음원의 위치를 찾는 실험을 수행하였다. 그 결과, 3차원 공간에 있어서 제시된 음원의 위치에서 청취자가 추정한 위치까지의 거리 오차는 약 30cm 이내로 나타났다.

A Study on Receipt Caused by Spatial Transformation of Kitchen Space in Apartment Housing

  • Choi, Lee-Seoung;Kim, Hyung-Woo
    • 한국가구학회지
    • /
    • 제19권4호
    • /
    • pp.260-272
    • /
    • 2008
  • The recent concept of kitchen is likely defined as "Kitchen Culture" including the function of living room where all families make a conversation as well as a dinner, and it is becoming another type of the residential environment, deviating from the stereotype as only cooking area. Particularly the comfortableness of living room is closely associated with a receipt function of kitchen, and the sort & dimension & size of furniture and diversity of shapes playa more meaningful role for improving our life standard & comfortableness compared with the past, nevertheless this receipt study is carelessly handled in the first phase of construction. This Study is focusing on understanding the modern concept of kitchen where the open space concept is being introduced as more reasonable space concept, and on suggesting a solution for receipt-function of the modern kitchen concept connected with "L-D-K (Living room - Dining room- Kitchen)" space idea. In the Chapter 2 the concept of receipt and function of kitchen, the wide variety of kitchen utensils was checked up, and in the Chapter 3 the change of trends of kitchen area & receipt space was considered, and finally in the Chapter 4 the modern concept of kitchen was presented, by instancing overseas examples with receipt planning. As a consequence, the alternative of the receipt in the modern kitchen is to install an Ireland table or another type of receipt-available table (lower furniture) in the dead space between kitchen & living room for motivating smooth communication and convenient receipt, and that is the trend nowadays. Kitchen desires a rapid change. Through this kind of study it should be more researched that kitchen is not an independent space any more and lies in the mutual connection of L-D-K.

  • PDF