• 제목/요약/키워드: Room acoustic

검색결과 253건 처리시간 0.023초

음향모드를 고려한 공동주택 중량충격음 소음해석 (Numerical Analysis of Heavy-weight Impact Noise for Apartment Units Considering Acoustic Mode)

  • 문대호;박홍근;황재승;홍건호;임주혁
    • 한국소음진동공학회논문집
    • /
    • 제22권7호
    • /
    • pp.676-684
    • /
    • 2012
  • Numerical analysis was performed to investigate the heavy-weight impact noise of apartment houses. The FEM is practical method for prediction of low-frequency indoor noise. The results of numerical analysis, the shape of the acoustic modes in room-2 are similar to that of acoustic pressure field at the fundamental frequency of acoustic modes. And the acoustic pressure was amplified at the natural frequency of the acoustic modes and structural modes. The numerical analysis result of sound pressure level at 63 Hz and 125 Hz octave-band center frequency are similar to the test results, but at 250 Hz and 500 Hz have some errors. Considering most of bang-machine force spectrum exists below 100 Hz, the noise at 250 Hz and 500 Hz are not important for heavy-weight impact noise. Thus, the FEM numerical analysis method for heavy-weight impact noise can apply to estimate heavy-weight impact noise for various building systems.

Rijke Tube를 이용한 열환경에서의 음향공 감쇠 특성연구 (A Study on Damping Characteristic under the Thermo-acoustic Condition using the Rijke Tube)

  • 김근철;전준수;김중일;고영성;김홍집
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.47-50
    • /
    • 2011
  • 본 연구에서는 열/음향 불안정성 환경 모사를 위하여 수평형의 Rijke tube를 설계/제작하였고, 이를 이용하여 구현하고자 하는 주파수대의 열구배를 갖는 공진현상이 발생됨을 확인하였다. Rijke tube를 이용해 열 음향 불안정 환경을 조성한 후, 음향공을 장착하여 얻어진 감쇠특성을 상온실험 자료와 비교/분석하여 열 음향 불안정 환경에서의 음향공 감쇠특성을 확인하였다. 열/유동 환경하에서의 감쇠 시간이 상온 환경에 비해 약 40% 증가함을 확인하였으며, 이로부터 음향공 설계시 열/유동 환경이 고려되어야 함을 확인하였다.

  • PDF

실측을 통한 대학 강의실 음향 특성에 관한 연구 (Room acoustic analysis in university classrooms using experimental results)

  • 김윤선;송민호;박인선;박상규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.493-502
    • /
    • 2007
  • Measurements of RT, EDT, $D_{50}$, $C_{50}$ and STI carried out in three different unoccupied University classrooms. For acoustic measurements, various sound sources are used (white noise, pistol shot, MLS and sweep signal). In this study, It found that interaction exists between sound source and place. Also there was high correlation between STI and various acoustic parameter.

  • PDF

원형평면을 갖는 공연장의 음향특성에 관한 실험적 연구 (An Experimental Study on the Acoustics Characteristics of Music Hall with Round Form)

  • 윤희경;김재수
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.67-72
    • /
    • 2003
  • The present article evaluates a performance hall, which improves sound efficiency. In general, the sidewall of the music hall is plane circle. thus there happens a focus phenomenon. To overcome it. the music hall improves its sound efficiency by making its sidewall irregular. After measuring impulse response from the performance hall, evaluation indices on the temporal distribution of sound energy such as RT, EDT, D50, C80, RASTI and BR were obtained, and based on them, indoor acoustic characteristics and the generation of echoes were determined. According to the results, evaluation indices showed that the acoustic condition was satisfactory in general. This study is to provide fundamental data for acoustic design of music hall with round form by analyzing the room acoustic characteristics of music hall.

  • PDF

D 문화체육센타 소공연장의 음향특성에 관한 연구 (An Study on the Acoustics Characteristics of D's Small Performance Hall)

  • 한경연;서정석;김재수
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2004년도 추계학술대회 논문집
    • /
    • pp.367-371
    • /
    • 2004
  • The purpose of this research is furnishing of basic material for acoustic planning hereafter, after understanding the acoustic merits and demerits through measuring and analyzing on room acoustic of small performance hall. As the result of the measurement, those physical evaluation indexes such as SPL, RT, EDT, $D_{50}$, $C_{80}$, RASTI have being kept the satisfiable acoustic condition for the service of performance hall. Therefore, as small performance hall is regarded as equipped with sufficient volume of sound, reverberatory feeling and diffusive feeling, it judges as an excellent performance place, also it is considered that it could be utilized as a useful material when design so similar performance hall, hereafter.

  • PDF

잔향실 성능 검증 및 향상 연구 (A Study on the Improvement of Reverberation Room's Performance)

  • 김성훈;주원호;김동해;배종국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.171-175
    • /
    • 2006
  • Recently, two reverberation rooms were built up of 300mm thick concrete walls in non-parallel pentagonal shape to measure the sound absorption, transmission, radiation, and impact insulation of acoustical materials, panels, doors, etc. Various acoustic tests, including the sound transmission test, were carried out to investigate their acoustic performances. In order to improve the performance, several modifications on these acoustical parameters, such as the acoustic mode, the position of specimen, the formation of diffuse field, the location of sound source, and flanking transmission, have been conducted. Through a series of tests, the reverberation rooms have been effectively improved so that it could perform a variety of acoustic tests with the international standard. And then, it is expected to be very helpful in developing the low noise design technology for ships.

  • PDF

학교체육관에서 스피커 배치방식에 따른 실내음향특성에 관한 연구 (A Study on the Room Acoustic Characteristics according to the Layout System of Speakers in the School Gymnasium)

  • 이주엽;김종빈;박현구;최형욱;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.462-467
    • /
    • 2000
  • The aim of this study is to provide fundamental data for acoustic design by analyzing the room acoustic characteristics according to the PA system used in the school gymnasium. The measurements were carried out accordance with the ISO 3382. The sources used in this study were four types; omni-directional, centralized, distribution, the combination of centralized and distribution sound source system. Omni-directional system is recommended by ISO for the acoustic test and the others are installed on the wall, column and ceiling in the school gymnasium for sound reinforcement.

  • PDF

가청화를 이용한 댐 수차 발전기소음의 저감효과 평가 (Evaluation on Reduction Effect of Dam Hydraulic Turbine Dynamo Noise using Auralization)

  • 정은정;정철운;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.253-257
    • /
    • 2007
  • In case of the hydraulic turbine dynamo room at Dam, due to its big volume and reflexible finishing material, since the noise of electricity-generation is amplifying, it influences the difficulty of mutual communication among the workers, also it is causing both mental and physical damages to those workers in the neighboring office. Accordingly, after presentation of the optimized renovation model of the hydraulic turbine dynamo room using the acoustic simulation, this Research has compared and evaluated them using the auralizational technique between the present condition of "before improvement" and the acoustic condition of "after improvement". As the result of psycho-acoustics experiment, as the acoustic conditions at both "before & after Improvement" were apparently compared, it appeared that there is a considerable amount of noise-reduction effect at psycho-acoustics. It is considered that such material could be utilized as the valuable data hereafter for the time when any construction and renovation of the hydraulic turbine dynamo room and other similar workshop.

  • PDF

청취자 선호도를 반영한 콘서트홀 음향설계 (Room acoustic design of a concert hall with a reflection of listeners' preference)

  • 김지현;오양기
    • 한국음향학회지
    • /
    • 제38권2호
    • /
    • pp.139-144
    • /
    • 2019
  • 콘서트홀의 소리품질을 나타내는 실내음향 지표들이 다수 개발되어 있으며, 청취자들이 기대하는 소리에 관한 경험적인 연구의 결과로 각 실내음향 지표들의 적정 범위가 제안되었다. 그러나 세월의 흐름에 따라 연주나 청취환경의 경향이 변하고 있고, 각 지표의 적정 범위에 대해 연구자들의 이견이 존재하는 등의 문제가 드러나고 있다. 콘서트홀의 음향환경에 대해 청취자들이 어떠한 선호개념을 갖고 있는지 조사하고 이를 콘서트홀의 음향설계에 반영하여야 한다. 이 연구에서는 음악의 연주 및 청취에 전문적인 경험을 갖고 있는 우리나라의 청취자들을 대상으로 콘서트홀 음향효과에 대한 선호도를 조사하고 평가하였다. 그리고 그 결과를 반영하여 청취조건을 구현하는 콘서트홀의 음향설계 프로세스를 제안하였다.

그람-슈미트 (Gram-Schmidt) 직교원리를 이용한 스테레오 음향 반향 제거기의 성능향상 (Performance Improvement of Stereo Acoustic Echo Canceler Using Gram-Schmidt Orthogonality Principle)

  • 김현태;박장식;손경식
    • 한국음향학회지
    • /
    • 제20권5호
    • /
    • pp.28-34
    • /
    • 2001
  • 적응 필터를 이용한 스테레오 음향 반향 제거기는 스테레오 신호 사이의 상호상관 (cross-correlation)이 매우 크기 때문에 수신측 회의실의 실제 반향경로를 추정하는 적응필터 계수의 수렴이 늦어지거나 상당히 오조정 된다. 본 논문에서는 계산량의 큰 증가없이 스테레오 반향제거기의 성능을 향상시키는 새로운 전처리 알고리즘을 제안한다. 제안하는 전처리기는 그람-슈미트 (Gram-Schmidt) 직교원리와 비선형 필터를 이용하여 상호상관을 감소시킨다. 컴퓨터 시뮬레이션에서 제안한 전처리 알고리즘의 성능이 기존의 방법에 비해 우수함을 보인다. 전송실의 경로가 변하는 경우에도 제안하는 전처리기를 사용한 스테레오 반향제거 기는 성능의 저하가 거의 없었다.

  • PDF