• 제목/요약/키워드: Roofing system

검색결과 32건 처리시간 0.024초

제주도 민속자료로 지정된 와가의 가사노동공간 분석 -정지.챗방.고팡을 중심으로- (An Analysis of Household Work Space of the Waga, a Roofing Tile System Authorized as Historical Preservation Units of Jeju Province -Focused on Jungji, Chatbang and Gopang-)

  • 이정림;김봉애
    • 한국주거학회논문집
    • /
    • 제12권3호
    • /
    • pp.41-49
    • /
    • 2001
  • This study attempts to present a new interpretation of the Jeju province Waga, authorized as Jeju province Folklore, in the context of lifestyles of residents distinctive in the Jungji, Chatbang, and Gopang system. Study results uncovered that (1) only one Jungji, a traditional house kitchen, exists in one house boundary, in the form of detached building in the 4 units of Gaok (K-2 Gaok, K-3 Gaok, C-1 Gaok, and C-2 Gaok) (2) Chatbang had multifaced-functions; as a place for diet for mistress and children, a place for preparing meals for a mister who diet in the room, and as an auxiliary meal-preparation facility in time of domestic celebration day. (3) Gopang was mostly a place for grain storage, and K-3 Gaok has one unit, K-1 Gaok, C-1 Gaok, and C-2 Gaok had 2 units, and K-2 Gaok and H Gaok had 3 untis of Gopang. (4) Jungji and Chatbang were correlated for meal preparation and diet while activity-line of flow was divided each other. (5) Jungji and Gopang were located at the opposite edges of of each house, revealing no consideration of indoor activities. (6) The ratios of space of Jungji, Chatbang and Gopang out of the whole house space were, average 23% in the case of Jungji located in the inner house, and average 37% in the case of Jingji located in the detached building, average 14% larger in the case of detached Jungji system.

  • PDF

Assessment of Rainwater Harvesting Potential in Ibadan, Nigeria

  • Lade, Omolara;Oloke, David
    • Environmental Engineering Research
    • /
    • 제18권2호
    • /
    • pp.91-94
    • /
    • 2013
  • Recently Ibadan in southwestern Nigeria has been facing severe water shortage due to the increase of population, social and economic activities. In order to meet the shortfall, attempts to utilize rainwater harvesting (RWH) have been made to provide an alternative source of water supply. A desk study was conducted to review various RWH technologies locally, regionally and globally. A hydrological analysis was also carried out using rainfall data for 30 years from two meteorological stations, with the aim of providing a more sustainable RWH system for water supply to private individuals, organizations, and government agencies. RWH is found to be technically feasible based on the prevailing rainfall pattern with over 90% of households having a rooftop constructed from technically appropriate materials. Results of the study indicate that an average roof of $80m^2$ will collect 82,835 L/yr (45 L/person/day) for a family of five people which is about the required water demand for drinking and cooking purposes. Hence, the capacity of storage tanks and the catchment area required for an all-purpose water supply system based on RWH are quite large. These can be reduced to affordable sizes, by collecting and storing water for cooking and drinking only while non-potable uses are supplemented by water from other sources. However, it must be highlighted that due to the type of roofing material, rainwater should go through proper treatment in order to be used for potable purposes. This study clearly shows that Ibadan city has a good rainwater harvesting potential.

양동마을 서백당과 관가정의 간 특성

  • 장선주;이강훈
    • 한국주거학회논문집
    • /
    • 제14권6호
    • /
    • pp.125-133
    • /
    • 2003
  • The purpose of this study is to reveal the characteristics of Kan as a compositional unit in relation with its usage, building base, structural system, and roofing system in Seo Baek Dang and Gwan Ga Jeong. The results are as follows: Seo Baek Dang and Gwan Ga Jeong share a common characteristics: Kan module forms the plan to be 1:1 in shape and enables flexibility in usage and regularity in compositional aspect. In Seo Baek Dang, there are active level differences in base, room floor levels and column heights to achieve intended roof design while minimizing the deviation of module (500 mm) of four sides enclosing the an-madang (inner courtyard) and, in Gwan Ga Jeong, instead of differentiating levels, maximizing the module control (up to 1,560 mm) and lowering the roof slope are found. They are regarded resulting in a rather plane manner. Through a comparative analysis, it is found out that these two houses have a common characteristics of Kan to form a quadrate plan while they have differences both in conceptual and tectonic manner that is 'how to build a house' in similar conditions of region, period and society. In addition, Kan as a module is clarified to have a relative value that regulates both structural and aesthetical aspects.

해외 사례분석을 통한 Cool Roof의 도입 방안 (Introducing Strategy of Cool Roofs based on Comparative Evaluation of Foreign Cases)

  • 최진호;엄정섭
    • 환경영향평가
    • /
    • 제19권6호
    • /
    • pp.591-605
    • /
    • 2010
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. This paper reviews worldwide experiences (USA, Japan and EU etc) for the potential benefits cool roofs offer in relation to building energy saving for comparison purposes. It is confirmed that there is a significant potential to the energy saving by introducing the cool roof in a Korean climate because of similarity in terms of HDD (Heating Degree Day) and CDD (Cooling Degree Day) as those countries reviewed. Such a comparative study highlights that the type of measurements performed and the quantitative parameters reported from the countries should be standardized in Korean context in order to implement further comparable experiments for scientifically sound investigations. It is anticipated that this research output could be used as a valuable reference in implementing a Nation-wide cool roofing strategy in the central and local governments since a suitable technical, more objective direction has been proposed based on the measured, fully quantitative performance of the involved components of a cool roof system in the global context. From this critical review, a very important step has been made concerning the practicality of cool roof in Korean context. Ultimately, the suggestion in this paper will greatly contribute to opening new possibilities for introducing cool roof in this country, proposed as an initial aim of this paper.

슈퍼 섬유를 활용한 일체형 Shock Energy Absorber Lanyard Protection Tube 제조 및 특성분석 (Characteristic and Development of All-in-one Shock Energy Absorber Lanyard Protection Tube used Super Fibers)

  • 조진원;권상준;김상태;염정현;강지만;지병철
    • 한국염색가공학회지
    • /
    • 제26권2호
    • /
    • pp.106-113
    • /
    • 2014
  • Work-related falls are a major problem in the construction and roofing industries. To avoid serious injury to the worker caused by high decelerations or forces, different systems to absorb the energy of a fall are implemented in personal protective equipment. In this study, shock energy absorber lanyard protection tube was prepared using high tenacity PET fiber, P-aramid fiber, and UHMWPE fiber, respectively. Dynamic load test and static load test, bursting strength test based on the Korea fall protection equipment standard(Korea Occupational Safety & Health Agency standard 2013-13) or conformity European safety test(CE : EN355) were conducted. Especially maximum arrest force by dynamic load test of energy absorber showed below 6,000N.

Causes of local collapse of a precast industrial roof after a fire

  • Bruno Dal Lago;Paride Tucci
    • Computers and Concrete
    • /
    • 제31권5호
    • /
    • pp.371-384
    • /
    • 2023
  • Precast roofing systems employing prestressed elements often serve as smart structural solutions for the construction of industrial buildings. The precast concrete elements usually employed are highly engineered, and often consist in thin-walled members, characterised by a complex behaviour in fire. The present study was carried out after a fire event damaged a precast industrial building made with prestressed beam and roof elements, and non-prestressed curved barrel vault elements interposed in between the spaced roof elements. As a consequence of the exposure to the fire, the main elements were found standing, although some locally damaged and distorted, and the local collapse of few curved barrel vault elements was observed in one edge row only. In order to understand and interpret the observed structural performance of the roof system under fire, a full fire safety engineering process was carried out according to the following steps: (a) realistic temperature-time curves acting on the structural elements were simulated through computational fluid dynamics, (b) temperature distribution within the concrete elements was obtained with non-linear thermal analysis in variable regime, (c) strength and deformation of the concrete elements were checked with non-linear thermal-mechanical analysis. The analysis of the results allowed to identify the causes of the local collapses occurred, attributable to the distortion caused by temperature to the elements causing loss of support in early fire stage rather than to the material strength reduction due to the progressive exposure of the elements to fire. Finally, practical hints are provided to avoid such a phenomenon to occur when designing similar structures.

동물복지 관련 육계농가 실태조사 (A Farm on Broiler Chickens' Welfare in Korea)

  • 천시내;이준엽;최양호;박규현;김두환;송준익;전중환
    • 한국축산시설환경학회지
    • /
    • 제19권1호
    • /
    • pp.33-38
    • /
    • 2013
  • We conducted investigations of the information and welfare of broiler chickens in Korea. The livestock housing of all broiler chicken farms were windowless type, bell feeder and nipple waterer were used, and stocking density was relatively higher (ranging from 18.2 $birds/m^2$ to 24.2 $birds/m^2$) than RSPCA's welfare standards for chicken hens (less than 19 $birds/m^2$). The ratios of sandwich panel, urethane form, slate, and steel plate in roofing materials were 61%, 21%, 13%, and 5%, respectively. The ratios of sandwich panel, urethane form, brick, and steel plate in wall materials were 61%, 21%, 13%, and 5%, respectively. The ratios of soil and concrete in flooring materials were 10% and 90%. The mist spray, fan, and cooling pad in cooling facilities were 42%, 32%, and 26%, respectively. Thus we believe that present data contribute to develop the animal welfare certification for broiler chickens and to improve animal welfare in Korea.

기포유동층에서 케미컬루핑 연소시스템을 위한 최적 산소전달입자 선정 (Selection of the Best Oxygen Carrier for Chemical Looping Combustion in a Bubbling Fluidized Bed Reactor)

  • 김하나;김정환;윤주영;이도연;백점인;류호정
    • 청정기술
    • /
    • 제24권1호
    • /
    • pp.63-69
    • /
    • 2018
  • 순산소 연소 기술 중 $CO_2$ 회수 비용 절감 효과가 가장 우수한 케미컬루핑연소(chemical looping combustion, CLC) 기술의 핵심인 산소전달입자의 선정을 위해 환원반응 특성 및 물리화학적 특성에 대한 연구를 진행하였다. 세 종류의 산소전달입자(SDN70, N018-R2, N016-R4)를 대상으로 기포유동층 반응기에서 환원반응기체의 농도 및 환원 반응 온도 변화에 따른 산소전달입자의 연료전화율(fuel conversion)과 $CO_2$ 선택도($CO_2$ selectivity)를 측정 및 비교 분석하였다. 또한 산소전달입자의 마모손실 정도 및 입자의 표면 특성을 분석하기 위해 내마모도(Attrition Index, AI) 및 BET surface area를 측정하였다. 결과적으로 세 종류의 산소전달입자 모두 케미컬루핑연소 시스템에 활용하기 적합함을 확인하였으며, 가장 우수한 입자는 N016-R4로 판단되었다.

소양면 지역사회 환경기초조사 (A Basie Community Health Survey in Rural Korea (Soyang-Myun))

  • 최승렬
    • Journal of Preventive Medicine and Public Health
    • /
    • 제6권1호
    • /
    • pp.133-160
    • /
    • 1973
  • 1. Introduction Community medicine with the concept of comprehensive medical care and an ideal medical care delivery system not only for an individual or family but for the whole community has emerged. In April 1970, the Presbyterian Medical Center started a hospital based community health service project in order to improve the health of the people in rural areas. Prior to commencing a comprehensive medical care system, a family survey was needed. The major objective of this survey was to obtain information concerning the people and their environment so as to be able to plan and implement a comprehensive medical care program in Soyang-Myun. 2. Survey Method An interview using a family record form was carried out for each household. This family record form was designed to get information about demography, family planning, environmental sanitation and vital statistics. Prior to beginning, the members of the survey team were trained in interviewing techniques for three days. The team consisted of a public health nurse, four nurse-aides, a sanitarian and four health extension workers who are working in our project, The survey was carried out during the period November 1971 to March 1972. 3. Project area 1) Population of Soyang-Myun was 11,668; male, 5,962 and female, 5,706. Sex ratio: 104.5. 2) Households : 1,858 3) Family size: The average household consisted of 6.3 persons. 4) Educational level of householder a. Illiterate 13% b. No schooling but able to read 10% c. Preschool children 19% d. Primary school 47% e. Middle school 7% f. High school 3% g. College or University 1% 5) Occupational distribution of householders a. Farmer 67% b. Laborer 13% c. Office worker 4% d. Merchant 4% e. Industrial worker 2% f. Unemployed 8% g. Miscellaneous 2% 6) Religious affiliation a. No religion 74% b. Buddhist 12% c. Protestant 10% d. Catholic 4% 4. Survey results Living Environment : a. Home ownership 95% b. Kinds of roofing Straw-thatched house 84% Tile-roofed house 10% Slate-roofed house 5% Other 1% c. Floor space Less than 6 pyong 10% 6-10 pyong 53% 11-15 pyong 24% 16-20 pyong 9% More than 20 pyong 4% d. Radio ownership 80% Environmental Sanitation : a. the source of drinking water public well 49% private well 30% drainage water 9% steam water 8% well pump 3% water distribution system 1% b. Distance between well and toilet more than 16meters 38% 6-10 meter 31% 11-15 meters 14% Less than 6 meters 17% c. The status of well management Bad 72% Fair 26% Good 2% d. General sanitary state of house Bad 37% Fair 51% Good 12% e. House drainage system had no house drainage. 77% Family Planning : a. 24% of the people have used contraceptives, but 12% ceased to use them. 76% have never used contraceptives. b. used methods 1oop 68% oral pill 16% vasectomy 4% condom 1% tubal ligation 1% two or more methods 10% Maternal Health : a. The number of conceptions of housewives under 50 years of age. 11 times 26% 6 times 11% 5 times 11% 4 times 9% b. The place of delivery own house 88% hospital 1% others 11% Treatment of general sickness : a. The place of treatment Soyang Health Center 31% Hospital (private or otherwise) 26% Pharmacy 14% Herb medicine 5% Private care 5% No treatment 12% Miscellaneous 7% b. Usual causes of diseases Unknown 46% Tuberculosis 29% Neuralgia 8% CVA 3% Bronchitis 3% Others 11%

  • PDF

어린이집 실내·외 석면노출 가능성 조사에 관한 연구 (A Survey on Asbestos Exposure Possibility in Indoor and Outdoor Environments of Childcare Centers)

  • 박화미;손병훈
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.122-129
    • /
    • 2014
  • Objectives: Because of its properties such as resistance to heat, chemicals and corrosion; tensile strength; sound absorption; and affordable price, asbestos has been widely used as a building material, fire resistant and retardant, thermal and heat insulator, soundproofing material, and electrical insulation. Since the prolonged inhalation of asbestos can cause serious illnesses such as lung cancer, mesothelioma, and asbestosis after an incubation period of 20 to 40 years, the mineral was classified as a Group 1 carcinogen by the International Agency for Research on Cancer, an intergovernmental agency forming part of the World Health Organization. Children and infants are more at risk than are adults if they are exposed to carcinogens, due to aweaker immunity that has not yet been fully developed. Most childcare centers are operated all day and children tend to spend a great amount of time in the centers. This is why it is important for them to be systematically isolated from environments that may expose them to asbestos. Materials: In order to understand both indoor and outdoor hazards to which children may have been exposed, the study focused on actual surveys of asbestos used in childcare centers, paying special attention to slate-roofed buildings in the vicinity of the centers. Results: A survey of a total of 211 childcare centers showed that the buildings of 18.1% of the centers contained asbestos, with 60.53% of the material being found in classroom ceilings. "Tex" was the most used material for ceilings, making up 89.47% of all ceilings. An outdoor survey showed that childcare centers in Daegu Metropolitan City had an average of 143 slate-roof buildings within a distance of 1km. Conclusions: Buildings housing mainly toddlers, children, teenagers and others more vulnerable to the toxicity of asbestos are not subject to asbestos investigation by law. A legal and practical basis for asbestos control is required for such buildings. In particular, housing materials which contain asbestos in day care centers require asbestos control. GIS should be used to identify the location of buildings with slate roofing materials in the vicinity of daycare centers in order to gauge toxicity of exposure to asbestos caused by potential asbestos friability possibility in outdoor conditions.