• Title/Summary/Keyword: Robust high frequency

Search Result 229, Processing Time 0.025 seconds

Detection system of Robust High Frequency Range via Noise Collection and Analysis

  • Chung, Myoungbeom
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.1
    • /
    • pp.71-76
    • /
    • 2017
  • Recently, there are various researches using inaudible high frequencies like as wireless communication based smart devices, data transmission algorithm, indoor positioning trace technologies. However, when they use high frequencies of inaudible range, they have a problem that the accuracy of data transmission with high frequencies was low because of interference from ambient noise in our real life. To solve this problem, in this paper, we proposed an application based on smart phone and server system for collection of ambient noise and detection of robust high frequency range. The server system could detect the robust high frequency range from statistical analysis of collected noise and the robust high frequency could avoid interference from ambient noise. We tested the proposed application's ability to gather noise and high frequencies for a certain period of time to evaluate performance. According to the testing results, we confirmed that the proposed application and server system could detect a robust high-frequency range via noise analysis in real life. Therefore, the proposed application and server could be a useful technology for future research on inaudible high frequencies.

Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper

  • Aly, Aly Mousaad
    • Smart Structures and Systems
    • /
    • v.13 no.3
    • /
    • pp.473-500
    • /
    • 2014
  • Tuned mass dampers (TMDs) have been installed in many high-rise buildings, to improve their resiliency under dynamic loads. However, high-rise buildings may experience natural frequency changes under ambient temperature fluctuations, extreme wind loads and relative humidity variations. This makes the design of a TMD challenging and may lead to a detuned scenario, which can reduce significantly the performance. To alleviate this problem, the current paper presents a proposed approach for the design of a robust and efficient TMD. The approach accounts for the uncertain natural frequency, the optimization objective and the input excitation. The study shows that robust design parameters can be different from the optimal parameters. Nevertheless, predetermined optimal parameters are useful to attain design robustness. A case study of a high-rise building is executed. The TMD designed with the proposed approach showed its robustness and effectiveness in reducing the responses of high-rise buildings under multidirectional wind. The case study represents an engineered design that is instructive. The results show that shear buildings may be controlled with less effort than cantilever buildings. Structural control performance in high-rise buildings may depend on the shape of the building, hence the flow patterns, as well as the wind direction angle. To further increase the performance of the robust TMD in one lateral direction, active control using LQG and fuzzy logic controllers was carried out. The performance of the controllers is remarkable in enhancing the response reduction. In addition, the fuzzy logic controller may be more robust than the LQG controller.

A new Robust Wavelet Shift Keying System Using Scaling and Wavelet Functions (스케일링 함수와 웨이브릿을 이용한 잡음에 강인한 새로운 웨이브릿 편이 변조 시스템)

  • Jeong, Tae-Il
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.98-103
    • /
    • 2008
  • There are the frequency shift keying(FSK), phase shift keying(PSK) and amplitude shift keying(ASK) in the conventional digital communications method. In this paper, We proposed a new robust wavelet shift keying system using scaling and wavelet function in the digital communication. Wavelet Transform consist of a low frequency and high frequency coefficient. When the input signal is one, if it finds the impulse response, the signal is separated from the scaling and wavelet function. The binary data is encoded by modulator which assigned the scaling function to 1(one), and wavelet to zero(0). It was demonstrated by experiment that the proposed algorithm can be a robust noise.

  • PDF

Real-time hybrid substructuring of a base isolated building considering robust stability and performance analysis

  • Avci, Muammer;Botelho, Rui M.;Christenson, Richard
    • Smart Structures and Systems
    • /
    • v.25 no.2
    • /
    • pp.155-167
    • /
    • 2020
  • This paper demonstrates a real-time hybrid substructuring (RTHS) shake table test to evaluate the seismic performance of a base isolated building. Since RTHS involves a feedback loop in the test implementation, the frequency dependent magnitude and inherent time delay of the actuator dynamics can introduce inaccuracy and instability. The paper presents a robust stability and performance analysis method for the RTHS test. The robust stability method involves casting the actuator dynamics as a multiplicative uncertainty and applying the small gain theorem to derive the sufficient conditions for robust stability and performance. The attractive feature of this robust stability and performance analysis method is that it accommodates linearized modeled or measured frequency response functions for both the physical substructure and actuator dynamics. Significant experimental research has been conducted on base isolators and dampers toward developing high fidelity numerical models. Shake table testing, where the building superstructure is tested while the isolation layer is numerically modeled, can allow for a range of isolation strategies to be examined for a single shake table experiment. Further, recent concerns in base isolation for long period, long duration earthquakes necessitate adding damping at the isolation layer, which can allow higher frequency energy to be transmitted into the superstructure and can result in damage to structural and nonstructural components that can be difficult to numerically model and accurately predict. As such, physical testing of the superstructure while numerically modeling the isolation layer may be desired. The RTHS approach has been previously proposed for base isolated buildings, however, to date it has not been conducted on a base isolated structure isolated at the ground level and where the isolation layer itself is numerically simulated. This configuration provides multiple challenges in the RTHS stability associated with higher physical substructure frequencies and a low numerical to physical mass ratio. This paper demonstrates a base isolated RTHS test and the robust stability and performance analysis necessary to ensure the stability and accuracy. The tests consist of a scaled idealized 4-story superstructure building model placed directly onto a shake table and the isolation layer simulated in MATLAB/Simulink using a dSpace real-time controller.

Uncertainty Modeling and Robust Control for LCL Resonant Inductive Power Transfer System

  • Dai, Xin;Zou, Yang;Sun, Yue
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.814-828
    • /
    • 2013
  • The LCL resonant inductive power transfer (IPT) system is increasingly used because of its harmonic filtering capabilities, high efficiency at light load, and unity power factor feature. However, the modeling and controller design of this system become extremely difficult because of parameter uncertainty, high-order property, and switching nonlinear property. This paper proposes a frequency and load uncertainty modeling method for the LCL resonant IPT system. By using the linear fractional transformation method, we detach the uncertain part from the system model. A robust control structure with weighting functions is introduced, and a control method using structured singular values is used to enhance the system performance of perturbation rejection and reference tracking. Analysis of the controller performance is provided. The simulation and experimental results verify the robust control method and analysis results. The control method not only guarantees system stability but also improves performance under perturbation.

Frequency-Temporal Filtering for a Robust Audio Fingerprinting Scheme in Real-Noise Environments

  • Park, Man-Soo;Kim, Hoi-Rin;Yang, Seung-Hyun
    • ETRI Journal
    • /
    • v.28 no.4
    • /
    • pp.509-512
    • /
    • 2006
  • In a real environment, sound recordings are commonly distorted by channel and background noise, and the performance of audio identification is mainly degraded by them. Recently, Philips introduced a robust and efficient audio fingerprinting scheme applying a differential (high-pass filtering) to the frequency-time sequence of the perceptual filter-bank energies. In practice, however, the robustness of the audio fingerprinting scheme is still important in a real environment. In this letter, we introduce alternatives to the frequency-temporal filtering combination for an extension method of Philips' audio fingerprinting scheme to achieve robustness to channel and background noise under the conditions of a real situation. Our experimental results show that the proposed filtering combination improves noise robustness in audio identification.

  • PDF

High-Robust Relaxation Oscillator with Frequency Synthesis Feature for FM-UWB Transmitters

  • Zhou, Bo;Wang, Jingchao
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.202-207
    • /
    • 2015
  • A CMOS relaxation oscillator, with high robustness over process, voltage and temperature (PVT) variations, is designed in $0.18{\mu}m$ CMOS. The proposed oscillator, consisting of full-differential charge-discharge timing circuit and switched-capacitor based voltage-to-current conversion, could be expanded to a simple open-loop frequency synthesizer (FS) with output frequency digitally tuned. Experimental results show that the proposed oscillator conducts subcarrier generation for frequency-modulated ultra-wideband (FM-UWB) transmitters with triangular amplitude distortion less than 1%, and achieves frequency deviation less than 8% under PVT and phase noise of -112 dBc/Hz at 1 MHz offset frequency. Under oscillation frequency of 10.5 MHz, the presented design has the relative FS error less than 2% for subcarrier generation and the power dissipation of 0.6 mW from a 1.8 V supply.

A High-Speed Synchronization Method Robust to the Effect of Initial SFO in DRM Systems (DRM 시스템에서 초기 샘플링 주파수 옵셋의 영향에 강인한 고속 동기화 방식)

  • Kwon, Ki-Won;Cho, Yong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.1A
    • /
    • pp.73-81
    • /
    • 2012
  • In this paper, we propose a high-speed synchronization method for Digital Radio Mondiale (DRM) receivers. In order to satisfy the high-speed synchronization requirement of DRM receivers, the proposed method eliminate the initial sampling frequency synchronization process in conventional synchronization methods. In the proposed method, sampling frequency tracking is performed after integer frequency synchronization and frame synchronization. Different correlation algorithms are applied to detect the first frame of the Orthogonal Frequency Division Multiplexing (OFDM) demodulation symbol with sampling frequency offset (SFO). A frame detection algorithm that is robust to SFO is selected based on the performance analysis and simulation. Simulation results show that the proposed method reduces the time spent for initial sampling frequency synchronization even if SFO is present in the DRM signal. In addition, it is verify that inter-cell differential correlation used between reference cells is roubst to the effect of initial SFO.

Active Control of Isolation Table Using $H_\infty$ Control ($H_\infty$ 제어를 이용한 방진대의 능동제어)

  • Kim, Kyu-Young;Yang, Hyun-seok;Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3079-3094
    • /
    • 1996
  • Recently, the high-precision vibration attenuation technology becomes the essence fo the seccessful development of high-integrated and ultra-precision industries, and is expected to continue playing a key role in the enhancement of manufacturing technology. Vibration isolation system using an air-spring is widely employed owing to its excellent isolation characteristics in a wide frequency range. It has, however, some drawbacks such as low-stiffness and low-damping features and can be easily excited by exogenous disturbances, and then vibration of table is remained for a long time. Consequently, the need for active vibration control for an air-spring vibration isolation system becomes inevitable. Furthermore, for an air-spring isolation table to be successfully employed in a variety of manufacturing sites, it should have a guaranteed robust performance not only to exogenous disturbances but also to uncertainties due to various equipments which might be put on the table. In this study, an active vibration suppression control system using H.inf. theory is designed and experiments are performed to verify its robust performance. An air-spring vibration isolation table with voice-coil-motors as its actuators is designed and built. The table is modeled as 3 degree-of-freedom system. An active control system is designed based on $H_\infty$control theory using frequency-shaped weighting functions. Analysis on its performance and frequency responce properties are done through numerical simulations. Robust characteristics of$H_\infty$ control on disturbances and model uncertainties are experimentally verified through (i) the transient response to the impact excitation of the table, (ii) the steady-state response to the harmonic excitation, and (iii) the response to the mass change of the table itself. An LQG controller is also designed and its performance is compared with the $H_\infty$ controller.

Position Control for Induction Servo Motors Using a Theory of Variable Structure Control (가변구조제어 이론을 이용한 유도 서보 전동기의 위치제어)

  • Hong Soon-Ill;Hong Jeng-Pyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.132-139
    • /
    • 2005
  • This paper describes the application of sliding mode control based on the variable structure control(VSC) concept for high-performance position control of an induction servo motor A design method based on external load parameters has been developed for the robust control of AC induction servo drive. Also, a slip frequency vector control with software current control technique has been adopted to achieve fast response of an induction motor drive The position control scheme is comprised of a variable structure controller and slip frequency vector control for inverter fed induction servo motor. Simulated results are given to verify the proposed design method by adoption of sliding mode and show robust control for a change of shaft inertia, viscous friction and torque disturbance.