• Title/Summary/Keyword: Road Lighting

Search Result 147, Processing Time 0.023 seconds

A Study on the Illuminance Distribution on the Pedestrian Road at the Central Business District for Classifying lighting Environments (조명환경구역 구분을 위한 도심상업지역 보행자 도로의 조도분포 실태조사)

  • Lee, Jong-Sik;Park, Jin-Chul;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.1-13
    • /
    • 2009
  • The purpose of this study is to investigate the applicability of the CIE standard on lighting environments to Korea. In the field study, horizontal and the vertical illuminance was measured at the pedestrian road in the central business district of a city, and the questionnaires were conducted to get information regarding pedestrian's satisfaction with lighting environment. Four areas were selected for this survey. That areas have different type of pedestrian roads concerning the lighting conditions and the number of walkers. From the results of the measurements, It is known that the illuminance of pedestrian roads is different according to the lighting conditions and the number of poot passengers. Also the results of questionnaires show that the illuminance of the pedestrian roads affect to the pedestrian's satisfaction. Lastly, the CIE standard on lighting environments is applicable to the central business district of the cities in Korea.

A Comparative Study on Visibility Performance Between Pole Type Lightings and Low-Level Lightings (등주식 조명과 낮은 조명의 성능 비교에 관한 연구)

  • Park, Wonil;Lee, Sukki;Jin, Minsoo;Kim, Yongseok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.6
    • /
    • pp.185-201
    • /
    • 2018
  • Road lighting is highly preferred as the major nighttime road safety countermeasures. When it comes to the pole-type road lighting, as it's installed at a certain height from the road surface, the driver is dazzled by the light source, interrupting the driver's visibility and furthermore, the light leaks to the area outside the road boundary, worsening the energy efficiency as well as generating the light pollution to the surrounding environment including the animals and plants. The study developed the low-level lighting systems, so it is possible to prevent the lights from being strayed, so there is no any side effects in terms of the sleep deprivation. The study compared the performance as the lightings between low-level lightings and conventional pole based lighting systems. As the results, the low-level lighting systems showed the higher performance in terms of average surface luminance, uniformity, glare compared to the conventional lighting systems.

Research on the Characteristics of the Light Trespass using by RELUX Program According to the Spatial Position of the Road Lightings in Residential Area Near Road (조명시뮬레이션 프로그램(RELUX)을 이용한 도로조명의 공간적 배치에 따른 침입광 영향 특성 연구)

  • Gu, Jinhoi;Jung, Jong-Hwan;Lee, Kyumok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.1-8
    • /
    • 2012
  • The road lightings have made our living environment safe and active, since it was first installed in 1900 in Korea. As the industry developed, various kind of road lightings have been installed in an outdoor area. But the spilt light from the road lightings have caused health problem like the sleeplessness, the depression, the failure to thrive and the nearsightedness to children. The light trespass caused by road lightings vary with the height of road lightings, the distance from road lightings to the window and the BUG rating of road lightings. In this paper, we analyze the effect on the light trespass by the spatial installation position of road lightings using by RELUX program. And we derive the characteristics of the light trespass according to the spatial installation position of the road lightings in residential area near road.

Safety Evaluation of the Lighting at the Entrance of a Very Long Road Tunnel: A Case Study in Ilam

  • Mehri, Ahmad;Hajizadeh, Roohalah;Dehghan, Somayeh Farhang;Nassiri, Parvin;Jafari, Sayed Mohammad;Taheri, Fereshteh;Zakerian, Seyed Abolfazl
    • Safety and Health at Work
    • /
    • v.8 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Background: At the entrance of a tunnel, reflection of sunlight from the surrounding environment and a lack of adequate lighting usually cause some vision problems. The purpose of this study was to perform a safety evaluation of lighting on a very long road in Ilam, Iran. Methods: The average luminance was measured using a luminance meter (model S3; Hagner, Solna, Sweden). A camera (model 108, 35-mm single-lens reflex; Yashica, Nagano, Japan) was used to take photographs of the safe stopping distance from the tunnel entrance. Equivalent luminance was determined according to the Holliday polar diagram. Results: Considering the average luminance at the tunnel entrance ($116.7cd/m^2$) and using Adrian's equation, the safe level of lighting at the entrance of the tunnel was determined to be 0.7. Conclusion: A comparison between the results of the safe levels of lighting at the entrance of the tunnel and the De Boer scale showed that the phenomenon of black holes is created at the tunnel entrance. This may lead to a misadaptation of the drivers' eyes to the change in luminance level at the entrance of the tunnel, thereby increasing the risk of road accidents in this zone.

Structural Behavior of Rib Reinforced Mg-Si Aluminum Alloy lighting Pole (리브보강 Al-Mg-Si계 가로등 등주의 구조적 거동)

  • Nam, Jeong-Hun;Joo, Hyung-Joong;Kim, Young-Ho;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.21 no.6
    • /
    • pp.8-14
    • /
    • 2008
  • Lighting system of road is an essential structure used for the safety of pedestrians and vehicles. Most of the lighting pole is made with steel which is vulnerable under corrosive environment. To overcome such corrosion problems, stainless steel and iron steel are used, but they are usually manufactured by hand which is not efficient. Due to their high strength and stiffness, when there is car collision with the lighting pole structure the safety of driver may not be ensured. Hence, the development of new-type lighting pole system which is easy to adjust the right on the road, lengthen the service life, and reduce the maintenance, is necessary. Lighting pole made with aluminum alloy is high in strength per unit weight, is strong against corrosive environment, and is easy to construct due to flexibility and right weight. But, because the strength and stiffness of the material is lower than that of steel, the structural safety and serviceability of the system can be a problem. To mitigate the structural problem associated with conventional lighting pole system, experimental investigation is conducted on the conventional lighting pole and rib reinforced aluminum alloy lighting pole, respectively. By comparison of results, it was found that the rib reinforced Mg-Si aluminum alloy lighting pole is efficiently applicable to the lighting pole system of road.

The Study of Complementary Standards to Improve Visibility on Crosswalk throughout Verification Studies after Reviewing Standards (횡단보도의 시인성 향상을 위한 기준검토 및 검증 테스트를 통한 보완 기준(안) 연구)

  • Lee, Mi-Ae;Lee, Dong-Hee;Lee, Yoon-Gyeong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.14-23
    • /
    • 2014
  • According to the analysis of crosswalk pedestrian accidents, accidents that occur at night represent 70% of all deaths among crosswalk pedestrians when compared to accidents occurring in the daytime. This is due to the poor visibility that hinders drivers to recognize pedestrians at night. Illuminance on the horizontal plane of the road and the current state of crosswalk lighting are not sufficient enough to comply with standards. Thus, we analyzed factors derived from lighting environment studies on improving crosswalk visibility, domestic and foreign crosswalk lighting standards, and subsequently proposed solutions which are needed to raise domestic crosswalk lighting standards, and a means to uphold those standards through proper verification.

Development of the Program Road lighting Road Surface Property Measuring Apparatus (도로 조명용 프로그램과 노면특성 장치의 개발)

  • Kim, Gi-Hoon;Sim, Sang-Man;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.1-6
    • /
    • 1999
  • Average illuminaoce and luminance can be calculated by grarhical rrethods to a certain extent, but to calculate for a wide place, a suitable software is needed. Softwares suitable for this purpose have been already developed in foreign nations, but the appropiate softwares for domestic use have not been developed 1berefore a program is develqJed which is executable in Hangul Windows. The softwares LAPRoad, is develqJed to calculate luminaoce and illuminance distribution of road surlace, as well as average luminance and illuminance, overall uniformity, longitudinal uniformity, threshold increement, veilling luminance, and glare. And an apparatus that measures road surface reflection properties is developed. Because the road surlace reflection properties is very important in luminance calculation, then concrete road surlace reflection properties were measered.asered.

  • PDF

Economic Evaluation of LED Luminaires for Tunnel Interior Zones

  • Cho, Sook-Hyun;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.7-13
    • /
    • 2013
  • There has been a need for the systematic evaluation of the economic efficiency between conventional fluorescent lamp lighting systems that have been used in tunnels and LED lighting systems. This study has evaluated basic tunnel lighting between the conventional fluorescent lighting systems and the LED lighting system using the evaluation tool of tunnel lighting by Life Cycle Cost (LCC) and using the economic efficiency evaluation method. In addition, the unit discount rate of the LED lighting system and the estimated increase in the price of electricity have made the estimated cost of LCC the same if two luminaires were used in the basic part of the tunnel.

Study of a Ray-Tracing Method for Optimized Road Light Design

  • Oh, Seon;Choi, Dae-Seob
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.4
    • /
    • pp.194-196
    • /
    • 2010
  • A study is presented of improved road light design for drivers and pedestrians with the use of a ray- or reverse ray-tracing method. Many existing road lights are unsuitable for drivers and pedestrians because of serious problems such as glare effect or randomicity of illuminated areas. This situation has arisen because in customary design methods the emphasis has been on simple factors such as luminance or electrical power. However a high luminance or electrical power consumption, alone, do not guarantee bright and good road lighting. So we have applied a ray-tracing method to the design of a road light reflector with the goals of ensuring that illuminated objects on the road can be seen more clearly and that the illuminating light is more comfortable for the eyes of drivers and pedestrians. We have set design targets for factors such as the uniformity of lighting on the road area per road light, the shading angles and the continuous luminance uniformity on long lengths of road. For set heights of the eyes of drivers and pedestrians eyes we have calculated a design guideline for the achievement of the above design targets. Then we designed a road light reflector using the reverse ray-tracing approach. Also we have achieved the same luminance on the road with almost half the power consumption, through the reduction of lighty loss. In an ideal design optimum parameters are suggested to be a shading angle of 75 degrees and a luminance uniformity of 0.5 on the road area. This reflector performance is achievable with a 250 watt power consumption ceramic discharge metal light source.

Electrical Characteristics Analysis of LED Lamps using Internal Converter for Road and Street Lighting (컨버터 내장형 LED 가로등 및 보안등의 전기적 특성 분석)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.238-244
    • /
    • 2010
  • In this paper, we studied electrical characteristics of internal converter type of LED lamps for road and street lighting. We surveyed electro-technical regulations and KS(Korean industrial standards) about LED luminairs. Waveforms of voltage and current, thermal distributions, insulation resistances between live parts and exposed conductive parts, and flame test of cover of LED lamps were experimented and analyzed. In regulations, insulation resistance between live conductors and exposed conductive parts should be greater than $0.2M{\Omega}$ in case nominal voltage of wiring is 220V. In KS codes, the value of insulation resistance should be greater than $2M{\Omega}$ while applying DC 500V or DC 100V. In the result of this study, waveforms of primary voltage and current were distorted. There was difference in waveforms of secondary voltage and current according to composition of converter. Mostly, insulation resistances were measured high more than regulation and code value but some measured points were measured badly($0.0M{\Omega}$). Cover of LED lamps was ignited easily. We expect that the results of this study would be helpful for revision of regulations and national codes for the electrical safety of LED road and street lighting.