• Title/Summary/Keyword: Rigid endoscope

Search Result 16, Processing Time 0.026 seconds

Removal of Endotracheal Granulation Tissue and Foreign Body via Tracheostoma used by Rigid Nasal Endoscope (경성 비내시경을 이용한 기관이물 및 육아조직 제거 2례)

  • 노경섭;송영호;김광훈;안회영
    • Korean Journal of Bronchoesophagology
    • /
    • v.7 no.2
    • /
    • pp.174-177
    • /
    • 2001
  • Previously, we used a rigid bronchoscope in removal of endotracheal granulation tissue and foreign body. But these method has poor visual field and difficulty in handling of the instruments, therefore there were restriction in removing the endotracheal granulation tissue and foreign body. Recently we underwent one case each of endotracheal granulation tissue and foreign body causing dyspnea and removed them by right angled forceps under visualization via nasal rigid endoscope inserted through the tracheal stoma. We suggest this method for removal of tracheal foreign body, granulation tissue and excision of tumorous condition in patients with tracheocutaneous fistula.

  • PDF

Endoscopic Transforaminal Suprapedicular Approach in High Grade Inferior Migrated Lumbar Disc Herniation

  • Kim, Hyeun-Sung;Ju, Chang-Il;Kim, Seok-Won;Kim, Jong-Gue
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.2
    • /
    • pp.67-73
    • /
    • 2009
  • Objective : Although endoscopic procedures for lumbar disc diseases have improved greatly, the postoperative outcomes for high grade inferior migrated discs are not satisfactory. Because of anatomic limitations, a rigid endoscope cannot reach all lesions effectively. The purpose of this study was to determine the feasibility of endoscopic transforaminal suprapedicular approach to high grade inferior-migrated lumbar disc herniations. Methods : Between May 2006 and March 2008, a suprapedicular approach was performed in 53 patients with high grade inferior-migrated lumbar disc herniations using a rigid endoscope and a semi-rigid flexible curved probe. One-to-four hours after surgery, the presence of remnant discs was checked with MRI. The outcomes were evaluated with the visual analogue scale (VAS) score and the Oswestry Disability Index (ODI) one week after surgery. Results : The L2-3 level was involved in 2 patients and the L3-4 level was involved in 14 patients, while the L4-5 level was involved in 39 patients. There were single piece-type in 34 cases and a multiple piece-type in 19 cases. Satisfactory results were obtained in all cases. The mean preoperative VAS for leg pain was $9.32{\pm}0.43$ points (range, 7-10 points), whereas the mean ODI was $79.82{\pm}4.53$ points (range, 68-92 points). At the last follow-up examination, the mean postoperative VAS for leg pain was $1.78{\pm}0.71$ points and the mean postoperative ODI improved to $15.27{\pm}3.82$ points. Conclusion : A high grade inferior migrated lumbar disc is difficult to remove sufficiently by posterolateral endoscopic lumbar dscectomy using a rigid endoscope. However, a satisfactory result can be obtained by applying a transforaminal suprapedicular approach with a flexible semi-rigid curved probe.

Flexible Loop Wheel Mechanism for Intestine Movement (탄성 루프형 바퀴를 이용한 장 내 이동 메커니즘)

  • Im, Hyeong-Jun;Min, Hyeon-Jin;Kim, Byeong-Gyu;Kim, Su-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.314-321
    • /
    • 2002
  • An endoscope is usually inserted into the human body for the inspection of the gullet, stomach, and large intestine (colon) and this may cause discomfort to patients and damage to tissues during diagnostic or therapeutic procedures. This situation necessitates a self-propelling endoscope. There are many kinds of mechanism to move in a rigid pipe. However, these methods are difficult to apply directly to the endoscope. The main reason is that human intestine cannot be considered as a uniform, straight, and rigid pipe. This paper proposes a flexible loop wheel mechanism, which is adaptable to the human intestine. This mechanism is designed and fabricated by a simple modeling, and tested by an experiment. Finally, the actuator is inserted into the pig colon.

Endoscopic Management of Cranial Arachnoid Cysts Using Extra-Channel Method

  • Kim, Myung-Hyun;Jho, Hae-Dong
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.6
    • /
    • pp.433-436
    • /
    • 2010
  • Objective : Arachnoid cysts (ACs) can be cured by making the definite and wide communication between the cyst and arachnoid space using endoscopy, but often it is impossible only through the usual working-channel (intra-channel) procedures. We discuss and propose a more valuable endoscopic technique with the presentation of our series of cases. Methods : We treated 9 patients with cortical AC in various locations with extra-channel endoscopic techniques. The patients ranged in age from 3 years to 60 years (mean age, 37.2 yrs). The follow-up period ranged from 12 to 26 months (mean follow-up duration, 17.2 months). All patients had large AC compressing the adjacent brain with clinical symptoms or signs. The authors performed extensive fenestration via single burr hole with the aid of endoscope. Being bypassed the rigid endoscope, through the space between the shaft of endoscope and guiding cannula (extra-channel method), fenestration procedures were done in the dry fields. Results : Eight (88.9%) patients had been treated successfully with endoscope. One patient required shunt procedure. Among the eight patients who were treated with endoscopic procedure, 6 patients (66.7%) showed cyst reduction, and two (22.2%) showed disappearance of cyst. Conclusion : We suggest that extra-channel method will be simple and easy to perform using more valuable instruments with wider working area, and may promise better results compared to the conventional intra-channel endoscopic procedures.

The use of augmented reality navigation technology in combination with endoscopic surgery for the treatment of an odontogenic cyst of the upper jaw: A technical report

  • Lysenko, Anna;Razumova, Alexandra;Yaremenko, Andrey;Ivanov, Vladimir;Strelkov, Sergey;Krivtsov, Anton
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.225-230
    • /
    • 2022
  • Purpose: This report presents the first known use of a rigid endoscope with augmented reality technology for the removal of an odontogenic cyst that penetrated the maxillary sinus and illustrates its practical use in a patient. Materials and Methods: In the preoperative period, cone-beam computed tomography was performed in a specially designed marker holder frame, and the contours of the cyst and the nearest anatomical formations were segmented in the 3D Slicer program. During the operation, a marker was installed on the patient's head, as well as on the tip of the endoscope, which made it possible to visualize the mass and the movement of the endoscope. The surgical intervention was performed with the support of augmented reality in HoloLens glasses (Microsoft Corporation, Redmond, WA, USA). Results: The use of this technology improved the accuracy of surgical manipulations, reduced operational risks, and shortened the time of surgery and the rehabilitation period. Conclusion: With the help of modern technologies, a navigation system was created that helped to track the position of the endoscope in mixed reality in real time, as well as to fully visualize anatomical formations.

Vaginal Endoscopy for Detecting Estrual Cycles and developing Artificial Insemination Technique in the Bitch (개에서 내시경을 이용한 발정주기 검사 및 인공수정 기법의 실험조사)

  • 신남식;문유식;최윤주;정동희;김용준;권오경
    • Journal of Veterinary Clinics
    • /
    • v.14 no.1
    • /
    • pp.93-98
    • /
    • 1997
  • The vaginal endoscopy was performed in two Labrador Retrievers from onset of vaginal bleeding until metestrus accompanying with vaginal smear and blood progesterone concentration to investigate estral changes, and the intrauterine infusion of radiopaque fluid using vaginal endoscope (rigid 25-degree endoscope, Karl Storz) was detected by radiogrphy to determine if theis technique is feasible for future artificial insemination in the dogs. During the proestrus vaginal mucous membrane folds were edematous and a large amount of clear red discharge was present. In the beginning of estrus, the mucous membrane folds was present and the amount of the red discharge was decreased. In the estrus there were obbvious shrinkage, angulation of the membrane folds and decreasing of the discharge. In metestrus the vaginal folds started to round out and the surface appeared moist and sticky. The endoscope used for endoscopic monitoring of the vaginal mucosa was advanced until the external os of the cervix could be visualized. A plastic catheter, 8Fr guage was manupulated into the cervical os and then advanced through into the uterus. The radiopaque fluid was injected into the uterus through the catheter and radiographs taken to detect the site of insemination using the endoscopic technique revealed the exact infusion of the fluid in the uterus, consequentlyto prove that this technique is usable for more successful artificial insemintion tn the bitch.

  • PDF

Gasless Endoscopic Thyroidectomy Via Single Incision Axillary Approach (액와 단일절개 접근법을 이용한 내시경적 갑상선 절제술)

  • Kim, So Young;Ryu, Yoonjong;Jeong, Woo-Jin;Ahn, Soon-Hyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.28 no.2
    • /
    • pp.114-117
    • /
    • 2012
  • Background and Objectives : To assure the surgical completeness of the gasless endoscopic thyroidectomy via single incision axillary approach using flexible videoscope which provide wide angle and working space, we compared single incision axillary approach and axillo-areolar approach by means of clinical, surgical outcomes. Materials and Methods : From March 2011 to July 2012, 24 patients who had underwent endoscopic thyroidectomy via transaxillary approach were enrolled. Of total, 17 patients underwent single incision axillary approach(group I) and the other 7 underwent axillo-areolar approach(group II). Results : Patient demographics, surgical indications were similar between the two groups. The operating time(group I 144.6min, group II 153.6 min ; p=.29), blood loss(group I : 55.4cc, group II : 35.7cc : p=.64), hospital stay(group I : 4.2days, group II : 4.4 days ; p=.65) were similar in the two groups. Overall, two patients in group I(2/17, 11.8%) experienced postoperative complications, including one hematoma and one seroma. Due to narrow working space, one patient was change to axillo-areolar approach during single incision axillary approach with $30^{\circ}$ rigid endoscope. Conclusion:Single incision axillary approach is safe and effective similar to other endoscopic thyroidectomy methods using flexible videoscope. Different with $30^{\circ}$ rigid endoscope, 10-mm flexible videoscope can put inside the axillary inicision site in different axis with endoscopic instruments. This difference in endoscopic axis help to prevent crash with endoscopic instrument.

Single Incision Flexible Endoscopic Cholecystectomy in Dogs : Feasibility Study (개에서 단일 통로 유연 내시경 담낭 절제술 : 유용성 연구)

  • Lee, So-Yeon;Shin, Beom-Jun;Jeong, Seong-Mok
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.555-561
    • /
    • 2011
  • Laparoscopic surgery is a well-established alternative to open surgery across disciplines. However, in veterinary medicine, laparoscopic surgery in dogs was rarely reported because of small abdominal size for multiple ports insertion. The concept of single-incision laparoscopic surgery (SILS) is to perform the entire laparoscopic operation through a single incision rather than conventional multiple small skin incisions. Indirect evidence of potential benefits of SILS, decreases operative morbidity related to reduction in port size, already exists. Therefore, this study was performed to evaluate the safety and feasibility of the modified form of SILS using flexible endoscope in Cholecystectomy before clinical adoption. A 2 cm single periumbilical incision was performed, and flexible endoscope was introduced into the abdominal cavity. A laparoscopic grasper was inserted into the abdominal cavity for the traction of gall bladder. Cystic duct and artery were ligated by 5 mm Hem-o-lok$^{(R)}$. Then, gall bladder was dissected and resected from the liver with 5 mm Autonomy Laparo-Angle Maryland dissector and endoscopic needle knife. Resected gall bladder was wrapped by using specimen pouch and was retrieved through abdominal incision from the cavity. All three gall bladders were successfully removed. Hematological changes were not observed during examination periods. No leakage sign was identified at necropsy. The flexible endoscope, as distinct from conventional rigid laparoscope, allows the visualization from various angles and the wide range of motion, result in less crowding.

Supraorbital Endoscopic Evacuation for Traumatic Intracerebral Hematomas in the Frontal Lobe

  • Oh, Hyuk-Jin;Hwang, Sun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.846-852
    • /
    • 2022
  • Objective : Traumatic intracranial hematomas have been rarely evacuated by endoscopic surgery. The frontal lobe is the usual location for the traumatic intracerebral hematoma (TICH). Endoscopic evacuation for the frontal TICHs via an eyebrow incision is to be presented as minimally invasive surgery. Methods : Thirteen patients with frontal TICHs were managed with endoscopic hematoma evacuation via eyebrow incision. After making the incision in the lateral eyebrow, a small frontal craniotomy was made, and the hematoma was evacuated under direct visualization of a rigid endoscope. No catheter was placed. Orbital rim resection, hematoma evacuation rate, surgical complications, and outcome at discharge were analyzed. Results : Men were 11 and the mean age was 54 years old (range, 27-86). Orbitotomy was performed in four patients, and no effect on the hematoma evacuation rate was observed. More than 80% of the hematoma volume was successfully removed in 10 cases. Hematoma configuration was not related to the hematoma evacuation rate. None of the patients underwent revision operation or decompressive craniectomy. Conclusion : Endoscopic evacuation of the TICHs with the supraorbital approach may be a good method to evacuate the hematoma located in the frontal base.

A Review of Endoscopic Removal Methods in 127 Cases of the Esophageal Foreign Bodies (소아 식도 이물의 내시경적 적출방법 변화에 대한 고찰)

  • Kim, Jum Su;Yang, Jung Soo;Jung, Hae Sung;Lee, Min Hye;Park, Chan-Hoo;Choi, Myoung Bum;Woo, Hyang-Ok;Youn, Hee-Shang
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.459-465
    • /
    • 2002
  • Purpose : The aim of this study was to evaluate the latest tendency of esophageal foreign body's extraction and to obtain a consensus from recent trends of indications and techniques of flexible endoscopy of esophageal FB in children. Methods : We retrospectively reviewed medical records of 127 cases with foreign bodies in esophagus at Dept. of Pediatrics and Otorhinolaryngology, Gyeongsang National University Hospital (GNUH) from Jun, 1987 to July, 2001. They were divided into two groups by the kinds of endoscopy : flexible endoscope(66 cases) or rigid endoscope(61 cases). Rigid endoscopy was performed under general anesthesia at Dept. of Otorhinolaryngology but flexible endoscopy was performed without general anesthesia or sedative drugs(midazolam or diazepam). Results : An annual number of cases of two groups were similar from 1991 to 1998. But from 1999, flexible endoscopy was performed actively. Asymptomatic cases were frequently observed in flexible endoscopy(28 cases/66 cases) but swallowing difficulties were frequently observed in the rigid endoscopy group(25 cases/61 cases). Other symptoms were vomiting, irritability, chest discomfort and abdominal pain. The total number of cases with underlying disease(esophageal stenosis, cerebral palsy) was 8. The total number of cases with complications (erosion, ulcer, bleeding, perforation) was 11. The above cases were not correlated between the two groups. In 55 cases(83.3%) of the flexible endoscopic group and 53 cases(86.8%) of the rigid endoscopic group, foreign bodies in the esophagus were removed within 24 hours. Conclusion : We could not find any benefit in rigid endoscopic technique. Flexible endoscopic FB removal can be performed safely and effectively in children by an experienced endoscopist.