• Title/Summary/Keyword: Ride-through

Search Result 236, Processing Time 0.029 seconds

A study on requirement of fault ride- through about voltage on IEEE 1547 (IEEE 1547a 전압기준에 대한 Fault Ride-through 요구사항에 관한 고찰.)

  • Lee, Yoon-min;Lee, Il-yong;Yoon, Sun-jae;Park, Ah-ryeon;Kim, Hee-jung;Cho, Joo-hyun;Kim, Young-min
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.81-82
    • /
    • 2016
  • 본 논문에서는 미국의 분산전원 연계용 PCS에 적용되는 Grid Code인 IEEE1547 Amendment의 fault ride-through에 대해 기술한다. IEEE 1547은 2014년 Amendment가 발행되었으며, 전압/주파수에 대한 사고판단 능력이 업데이트 되어 fault ride-through의 범위가 변경되었다. 개정된 IEEE1547a의 기준을 분석하고, 이를 적용한 fault ride-through 기능을 PSIM 시뮬레이션을 통하여 검증하였다.

  • PDF

PLL Control Strategy for ZVRT(Zero Voltage Ride Through) of a Grid-connected Single-phase Inverter (계통연계형 단상 인버터의 ZVRT(Zero Voltage Ride Through)를 위한 PLL 제어 전략)

  • Lee, Tae-Il;Lee, Kyung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.169-180
    • /
    • 2019
  • Grid codes for grid-connected inverters are essential considerations for bulk grid systems. In particular, a low-voltage ride-through (LVRT) function, which can contribute to the grid system's stabilization with the occurrence of voltage sag, is required by such inverters. However, when the grid voltage is under zero-voltage condition due to a grid accident, a zero-voltage ride-through (ZVRT) function is required. Grid-connected inverters typically have phase-locked loop (PLL) control to synchronize the phase of the grid voltage with that of the inverter output. In this study, the LVRT regulations of Germany, the United States, and Japan are analyzed. Then, three major PLL methods of grid-connected single-phase inverters, namely, notch filter-PLL, dq-PLL using an active power filter, and second-order generalized integrator-PLL, are reviewed. The proposed PLL method, which controls inverter output under ZVRT condition, is suggested. The proposed PLL operates better than the three major PLL methods under ZVRT condition in the simulation and experimental tests.

Examination on the variation of ride comfort for korean high speed train through on-line test (시운전 시험을 통한 한국형 고속열차의 승차감 변화추세에 관한 연구)

  • Kim, Young-Guk;Mok, Jin-Yong;Kim, Seog-Won;Park, Chan-Kyeong;Kim, Ki-Hwan;Park, Tae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.144-149
    • /
    • 2005
  • In this paper, we introduce the variation of ride characteristics for HSR 350x(Korea High Speed Train project) through on-line test during about 3 years. The concept of term "ride comfort" is equivocal. Generally it is evaluated as the vehicle vibration. The ride comfort for HSR 350x has been assessed by statistical method according to UIC 513R. The testing results show that HSR 350x has no problems from the viewpoint of the comfort ride on the high speed line and conventional line and that 1st and 2nd suspensions play an important role in the ride characteristics for high speed train.

Low Voltage Ride Through Test for Smart Inverter in Power Hardware in Loop System (전력 HILs를 활용한 스마트 인버터의 LVRT 시험)

  • Sim, Junbo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.101-105
    • /
    • 2021
  • Encouragement of DER from Korean government with several policies boosts DER installation in power system. When the penetration of DER in the grid is getting high, loss of generation with break-away of DER by abnormal grid conditions should be considered, because loss of high generation causes abnormal low frequency and additional operations of protection system. Therefore, KEPCO where is Korean power utility is preparing improvement in regulations for DERs connected to the grid to support abnormal grid conditions such as low and high frequencies or voltages. This is called 'Ride Through' because the requirement is for DER to maintain grid connection during required periods when abnormal grid conditions occur. However, it is not easy to have a test for ride through capability in reality because emulation of abnormal grid conditions is not possible in real power system in operation. Also, it is not easy to have a study on grid effect when ride through capability fails with the same reason. PHILs (Power Hardware In the Loop System) makes it possible to analyze power system and hardware performance at once. Therefore, this paper introduces PHILs test methods and presents verification of ride through capability especially for low voltage grid conditions.

Analysis of Ride Comfort for Korean High Speed Train through On-line Test (시운전 시험을 통한 한국형 고속전철에 대한 승차감의 분석)

  • 김영국;김석원;박찬경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.549-554
    • /
    • 2003
  • Recently, the ride comfort problem becomes increasingly important because of today's needs for train speedup. The concept of ride comfort is equivocal. Generally, it is defined as the body vibration. The prototype of Korean high speed train (KHST), composed of two power cars, two motorized cars and three trailer cars, has been designed, fabricated and tested by the domestic researchers. In this paper, the ride comfort has been reviewed by the experimental method. The on-line test of KHST has been carried out up to 260km/h in the KTX line and proved that KHST has no problems from the viewpoint of the comfort ride at this speed. And the ride index lot KHST has been predicted at 300km/h and 350km/h by fitting curve.

  • PDF

An improved Fault Ride Through control scheme for Doubly fed induction generator (이중여자 유도형 풍력발전기의 Fault Ride Through 향상 제어기법에 관한 연구)

  • Lee, Sung-Eun;Kim, Yun-Seong;Won, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1116_1117
    • /
    • 2009
  • 전력계통에서의 풍력 발전의 설치가 증가하면서 사고 발생시 전체 계통에 대한 신뢰도 및 안정도에 영향을 미친다. 이를 고려한 Fault Ride Through 제어 기법은 보다 안정적인 계통운영을 위한 방안이다. 최근 대부분의 풍력발전시스템은 이중여자 유도형 발전시스템(DFIG)이 설치되는데, 이는 전력변환장치를 이용한 유효 및 무효 전력 제어가 가능한 가변속 풍력발전시스템이다. 본 논문은 PSCAD/EMTDC를 통해 DFIG를 모델링하고 Crow Bar와 Rotor Side Converter의 연계 제어를 이용한 Fault Ride Through 제어 기법을 시뮬레이션 결과를 통해 확인 하였다.

  • PDF

Transient Stability Studies on Fault-Ride Through of Wind Turbine Generators (풍력발전기 Fault-Ride Through 검토를 위한 과도안정도 해석)

  • Park, Jin-Woo;Pyo, Gi-Chan;Lee, Seung-Keu;Lee, Kang-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.221-222
    • /
    • 2008
  • 신재생에너지인 풍력발전이 우수한 실효성 및 경제성으로 인하여 보급이 지속적으로 증가되고 있다. 전력계통에서 발생하는 단락 및 지락고장은 고장 인접 풍력발전 설비 보호를 위해 풍력발전기를 계통으로부터 분리한다. 전력공급 신뢰도와 계통운영의 안정도를 향상시키기 위해서 풍력발기가 Fault-ride through 기능을 갖도록 하여 이를 보완한다. 본 논문에서 과도안정도 해석 프로그램을 이용하여 Fault-ride through 중요 변수인 전압저하 정도 및 고장지속 시간 등을 모의하여 실제 계통에 적용 가능한 모형을 제안한다.

  • PDF

PLL Control Strategy for ZVRT(Zero Voltage Ride Through) of a Grid-connected Single-phase Inverter (계통연계형 단상 인버터의 ZVRT(Zero Voltage Ride Through)를 위한 PLL 제어 전략)

  • Lee, Taeil;Lee, KyungSoo
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.150-152
    • /
    • 2018
  • 계통 사고 시 계통연계형 인버터에 대한 각국의 계통 규정(Grid Code)이 더욱 엄격해 지고 있다. 계통 규정은 특히, 계통 내 저전압 사고로 인한 인버터 운전계속성(Low Voltage Ride Through, LVRT)뿐만 아니라 0 전압 사고 시 운전계속성(Zero Voltage Ride Through, ZVRT)을 통해 인버터가 계통 안정화에 기여할 것을 요구하고 있다. 계통연계형 인버터는 계통전압과 인버터 출력 위상을 일치시키는 PLL제어가 적용되며 본 논문에서는 위상 추종이 어려운 0 전압 상황에서도 안정적인 위상 추종 및 인버터 출력이 가능한 PLL 방법을 제안한다. 단상 인버터에 Notch filter-PLL, APF를 이용한 dq-PLL, 및 SOGI-PLL(Second-order Generalized Intergrator)을 적용하고 독일, 미국, 및 일본의 0 전압 상황에 대해 시뮬레이션과 실험을 진행하여 제안한 PLL 기법의 ZVRT 유효성을 확인하였다.

  • PDF

Reactive Current Assignment and Control for DFIG Based Wind Turbines during Grid Voltage Sag and Swell Conditions

  • Xu, Hailiang;Ma, Xiaojun;Sun, Dan
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.235-245
    • /
    • 2015
  • This paper proposes a reactive current assignment and control strategy for a doubly-fed induction generator (DFIG) based wind-turbine generation system under generic grid voltage sag or swell conditions. The system's active and reactive power constrains during grid faults are investigated with both the grid- and rotor-side convertors (GSC and RSC) maximum ampere limits considered. To meet the latest grid codes, especially the low- and high-voltage ride-through (LVRT and HVRT) requirements, an adaptive reactive current control scheme is investigated. In addition, a torque-oscillation suppression technique is designed to reduce the mechanism stress on turbine systems caused by intensive voltage variations. Simulation and experiment studies demonstrate the feasibility and effectiveness of the proposed control scheme to enhance the fault ride-through (FRT) capability of DFIG-based wind turbines during violent changes in grid voltage.

Ride-through control method for instantaneous power interruption in V/f controlled drive system (순간 정전 시 V/f 제어의 Ride Through 운전)

  • Choi, Seung-Cheol;Lee, Hak-Jun;Hong, Chanook;Lee, Sang-Joon
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.558-560
    • /
    • 2019
  • 범용 인버터는 계통 전원의 전압 강하 또는 정전 발생 시, 정류기의 직류단 전압이 감소하여 인버터 고장(fault)이 발생한다. 보호 동작으로서 인버터는 일시적으로 전원 공급이 이루어 지지 않는 상태에서 제어 기능 및 관리가 이루어 질 수 있도록 Ride-Through 운전을 수행한다. 고장 발생 없이 제어 시스템 상태를 유지하여 전원 복구 후, 빠른 재기동이 가능하다. 본 논문에서 V/f 제어를 사용하는 범용 인버터를 고려한 Ride-Through 방법으로 KEB(Kinetic Energy Backup) 운전을 제안한다. KEB 운전은 순시 정전에 의한 인버터 고장 방지를 위해 요구되는 에너지를 계산하고 슬립 주파수를 조절하여 회생 운전을 통해 인버터의 직류단 전압을 일정하게 유지한다. 제안한 방법은 실험을 통해 유효성을 검증한다.

  • PDF