• Title/Summary/Keyword: Retention Time

Search Result 1,732, Processing Time 0.03 seconds

A study of Recess Channel Array Transistor with asymmetry channel for high performance and low voltage Mobile 90nm DRAMs (고성능 저전압 모바일향 90nm DRAM을 위한 비대칭 채널구조를 갖는 Recess Channel Array Transistor의 제작 및 특성)

  • Kim, S.B.;Lee, J.W.;Park, Y.K.;Shin, S.H.;Lee, E.C.;Lee, D.J.;Bae, D.I.;Lee, S.H.;Roh, B.H.;Chung, T.Y.;Kim, G.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.163-166
    • /
    • 2004
  • 모바일향 90nm DRAM을 개발하기 위하여 비대칭 채널 구조를 갖는 Recess Channel Array Transistor (RCAT)로 cell transistor를 구현하였다. DRAM cell transistor에서 junction leakage current 증가는 DRAM retention time 열화에 심각한 영향을 미치는 요인으로 알려져 있으며, DRAM의 minimum feature size가 점점 감소함에 따라 short channel effect의 영향으로 junction leakage current는 더욱 더 증가하게 된다. 본 실험에서는 short channel effect의 영향에 의한 junction leakage current를 감소시키기 위하여 Recess Channel Array Transistor를 도입하였고, cell transistor의 채널 영역을 비대칭으로 형성하여 data retention time을 증가시켰다. 비대칭 채널 구조을 이용하여 Recess Channel Array Transistor를 구현한 결과, sub-threshold 특성과 문턱전압, Body effect, 그리고, GIDL 특성에는 큰 유의차가 보이지 않았고, I-V특성인 드레인 포화전류(IDS)는 대칭 채널 구조인 transistor 대비 24.8% 정도 증가하였다. 그리고, data retention time은 2배 정도 증가하였다. 본 실험에서 얻은 결과는 향후 저전압 DRAM 개발과 응용에 상당한 기여를 할 것으로 기대된다.

  • PDF

A Performance Evaluation of the Highly Efficient Coagulation System for the Treatment of Overflows from Primary Clarifier in WWTP (강우시 하수처리장 일차침전지 월류수 처리를 위한 고효율응집시스템의 적용성 평가)

  • Gwon, Eun-Mi;Oh, Seok-Jin;Kim, Heung-Seup;Cho, Seung-Ju;Lee, Seung-Chl;Ha, Sung-Ryong;Lim, Chea-Hoan;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.391-398
    • /
    • 2011
  • This study is to develop highly efficient coagulation system(HECS) that runs treatment with a short retention time to cover the overflow in the rain, which coagulation, mixing and settling are contacted in a single reactor and to estimate the applicability. Setting up 100ton/day-size pilot scale plant, the results of continuous operation in case of runoff, maintaining 20 minute-retention time at optimum chemical injection condition(Alum 100mg/L, Polymer 1.0mg/L) shows the highest removal efficiency(Turbidity 93.1%, TCODcr 80.6%, BOD 81.8%, SS 92.5%, TN 72.3% and T-P 87.3%). It was estimated that the large amount of cost for separate sewage system and the size of area for system instruction can be reduced if the HECS is applied for CSOs treatment because the HECS is so compact and quickly. When we see the results, HECS from this study could be able to treat the pollutant quickly within a short retention time only with coagulant and polymer, which could show high applicability.

Effect of Hydraulic Retention Time on Fermentative Hydrogen and Byproducts Production from Food Waste (음식물쓰레기 발효 시 수리학적 체류시간에 따른 수소 및 부산물 생성 특성)

  • Kim, Sang-Hyoun;Shin, Hang-Sik
    • KSBB Journal
    • /
    • v.20 no.6
    • /
    • pp.443-446
    • /
    • 2005
  • Hydrogen fermentation from food waste was attempted at different hydraulic retention time(HRT, 18-42 h). A continuous reactor fed with ground, alkali-treated and diluted food waste(average VS 4.4%) exhibited stable hydrogen production during 126 days. Hydrogen production depended on HRT, resulting in the maximum values of 25.8 mL $H_2/g\;VS_{added}$, 0.36 mol $H_2/mol\;hexose_{added}$ and 0.91 L $H_2/L/d$ at HRT 30 h. n-Butyrate and isopropanol production increased with hydrogen production increased, while acetate production decreased. The fermentation efficiency ranged from 53.3 to 65.7%, which implied that hydrogen fermentation would substitute conventional acidogenesis of food waste.

Effects of Nutrient Concentration and Hydraulic Retention Time on the Removal of N and P by Phragmites japonica Steudel (영양염류의 유입농도와 수리학적 체류시간에 따른 달뿌리풀(Phragmites japonica Steudel)의 질소와 인 제거능)

  • 신정이;차영일
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.2
    • /
    • pp.153-158
    • /
    • 1999
  • Uptakes of N and P by Phragmites japonica Steudel. are determined in continuous flow tanks as a function of hydraulic retention time (HRT, days) and nutrient concentration (NC). Results show that the uptake was higher at shorter HRT and higher nutrient concentration, and the regression equations were estimated. Mean above ground biomass of Phragmites japonica in the middle reaches of Sagimak stream was 335.92 g/$m^2$, and estimated uptake by this vegetation were 7.31~20.15 NH$_4$-N, 31.15~95.84 NO$_3$-N, and 4.09~11.48 PO$_4$-P mg/$m^2$/day in Sagimak stream, respectively when HRT was 1~5 days. According to this study, it is concluded that Phragmites japonica Steudel. are suitable for water quality improvement of stream through nutrient uptake at short HRT and high concentration.

  • PDF

Effect of Sulfide Removal on Sulfate Reduction at pH 5 in a Hydrogen Fed Gas-Lift Bioreactor

  • Bijmans, Martijn F.M.;Dopson, Mark;Ennin, Frederick;Lens, Piet N.L.;Buisman, Cees J.N.
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.11
    • /
    • pp.1809-1818
    • /
    • 2008
  • Biotechnological treatment of sulfate- and metal-ions-containing acidic wastewaters from mining and metallurgical activities utilizes sulfate-reducing bacteria to produce sulfide that can subsequently precipitate metal ions. Reducing sulfate at a low pH has several advantages above neutrophilic sulfate reduction. This study describes the effect of sulfide removal on the reactor performance and microbial community in a high-rate sulfidogenic gas-lift bioreactor fed with hydrogen at a controlled internal pH of 5. Under sulfide removal conditions, 99% of the sulfate was converted at a hydraulic retention time of 24 h, reaching a volumetric activity as high as 51 mmol sulfate/l/d. Under nonsulfide removal conditions, <25% of the sulfate was converted at a hydraulic retention time of 24 h reaching volumetric activities of <13 mmol sulfate/l/d. The absence of sulfide removal at a hydraulic retention time of 24 h resulted in an average $H_2S$ concentration of 18.2 mM (584 mg S/I). The incomplete sulfate removal was probably due to sulfide inhibition. Molecular phylogenetic analysis identified 11 separate 16S rRNA bands under sulfide stripping conditions, whereas under nonsulfide removal conditions only 4 separate 16S rRNA bands were found. This shows that a less diverse population was found in the presence of a high sulfide concentration.

Use of biofilter as pre-treatment of polluted river water for drinking water supply

  • Suprihatin, Suprihatin;Cahyaputri, Bunga;Romli, Muhammad;Yani, Mohamad
    • Environmental Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.203-209
    • /
    • 2017
  • Innovations in the biofiltration process can provide effective solutions to overcome crucial water pollution problems. The elimination of pollutants is a result of the combined effects of biological oxidation, adsorption and filtration processes. This research aims to evaluate the performance of quartz sand biofiltration for removing total suspended solids, turbidity, color, organic matter, and ammonium from polluted river water and develop an empirical model for designing quartz sand biofilters for the treatment of polluted river water. Experiments were conducted using two biofilter units filled with quartz sand as filter media. A set of experiments were performed to evaluate the effect of hydraulic retention time on biofilter performance in removing water contaminants. The kinetics of organic matter removal were also determined to describe the performance of the biofilter. The results show that biofiltration can significantly remove river water pollutants. Removal efficiency depends on the applied hydraulic retention time. At a hydraulic retention time of two hours, removal efficiencies of total organics, ammonium and total suspended solids were up to 78%, 82%, and 91%, respectively. A model for designing quartz sand biofiltration has been developed from the experimental data.

Influence of hydraulic retention time on biogas production during leachate treatment

  • Baati, Souaad;Benyoucef, Fatima;Makan, Abdelhadi;El Bouadili, Abdelaziz;El Ghmari, Abderrahmene
    • Environmental Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.288-293
    • /
    • 2018
  • The main objective of this study is to investigate the influence of hydraulic retention time (HRT) on biogas production during leachate treatment using an anaerobic reactor type Upflow Anaerobic Sludge Blanket. For this purpose, four HRTs ranging from 12 to 48 h were experienced. The obtained results showed that higher amount of biogas could be produced during longer HRTs. However, HRTs longer than 48 h could not affect clearly the biogas generation and considered as unnecessary given the small additional amount of biogas produced during the degradation process. A volume of $0.434L/L_{leachate}/d$ was achieved during the treatment with a HRT of 48 h. The higher biogas production, the smaller chemical oxygen demand (COD) values achieved. Besides, COD removal and biogas production positively correlate, showing that the active biomass has degraded effectively the organic load to produce biogas. Moreover, all the analyzed physicochemical parameters have experienced a decrease after 48 h except for the pH, which increased to approximately neutral value. More precisely, a decrease of 93.8%, 89.7%, 95%, 70%, 77%, and 84.4% was recorded for COD, electrical conductivity, total suspended solid, turbidity, $NH_4{^+}-N$, and $NO_3{^-}-N$, respectively.

Characteristics of Anaerobic Acid Fermentation with Food waste leachate by Reactor Type of Retention Time for Landfill Site Injection (매립지 주입을 위한 음폐수 산발효 시 반응기 형태와 체류시간에 따른 특성)

  • Moon, Kwangseok;Kim, Jaehyung;Koo, Hyemin;Lim, Junhyuk;Kim, Nakjoo;Chang, Wonseok;Pak, Daewon
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.125-131
    • /
    • 2014
  • In order to increase landfill gas (LFG) production with food waste leachate, this study was confirmed to be acidogenetic conditions for landfill site injection. Thereby, it was conducted for acidogenetic treatments to determine the decrease in viscosity and VFA production. After acidogenesis treatments, solubility of food waste leachate increased approximately 15%, and as a result, UASB and CSTR were similar by reactor type using the change of retention time. Based on the result of the change in viscosity by reactor type, efficiency of UASB showed approximately 11.38% of higher decrease in viscosity as $76.95{\pm}3.27%$ vs. CSTR. Also, VFA production showed the higher increase of 2.01 times (UASB) and 1.76 times (CSTR) respectively at the point of increasing retention time from 3 to 5 days. From the above results, efficiency of UASB in a reactor was relatively higher because large molecular lead to longer retention time than small molecular due to having screen effect in the fixed media.

A study on Performing Time of Neurobehavioral Test in Workers exposed to Organic Solvents (유기용제 폭로 근로자에 있어서 신경행동검사의 시행시점에 관한 연구)

  • Park, Kang-Won;Park, In-Geun;Kim, Jin-Ha;Bae, Kang-Woo;Lee, Duk-Hee;Lee, Yong-Hwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.171-179
    • /
    • 1997
  • This study was performed to see whether neurobehavioral tests was affected by the exposure-free time in the workers chronically exposed to organic solvents. Thirty-four female workers were participated and four items among neurobehavioral core test battery of World Health Organization, including digit span, Santa Ana Dexterity, digit symbol and Benton Visual Retention, were administered to the workers. Test was conducted three times-preshift on Monday, preshift on Weekday and during shift on Weekday-per person and the interval of tests was 2 weeks. Digit span forward, Santa Ana Dexterity, digit symbol, and Benton Visual Retention showed significant decrements by performing time, especially during shift on Week-day versus preshift on Monday and preshift on Weekday. In addition, the score at preshift on Weekday was significantly lower than preshift on Monday, in preferred Santa Ana Dexterity and digit symbol. Generally, those who were exposed to high concentration, over 50 years and under 6 years of education showed marked decrease of score at during shift. So, it would be desirable that neurobehavioral test is conducted at preshift on Monday and items related to short term memory could be considerable to be done at preshift on Weekday.

  • PDF

Assessment of Hydraulic Behavior and Water Quality Variation Characteristics in Underground Reservoir (지하저수조의 수리적 거동과 수질변화 특성 평가)

  • Lee, H.D.;Bae, C.H.;Kim, J.H.;Hwang, J.W.;Hong, S.H.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 2005
  • The assessment on characteristics of hydraulic behavior and water quality variations of underground reservoirs of buildings were studied. Firstly, it was thought that underground reservoir capacities($m^3$) of buildings should be not determinated by the uniform and same methods but be estimated on the basis of the dwelling areas on dominated households and their residential characteristics, because these characteristics influence significantly on actual water usages and patterns of buildings. Secondly, it was likely that the average reduction rate of residual chlorine in underground reservoirs were affected from the their capacities, because the average reduction rate of residual chlorine in underground reservoirs under $1,000m^3$ was 43 percent, on the other hand, that rate of underground reservoirs over $1,000m^3$ was 60 percent. Thirdly, through the field investigation, the retention time of drinking water in underground reservoirs were in the range from 0.3 day to 3.9 day. In addition to, the average reduction rate of residual chlorine were depended largely on the retention time of drinking water. When the retention time was under 24 hours, the average reduction rate of residual chlorine was 45 percent, and in case of over 24 hours, was 49 percent. Fourth, water level in underground reservoirs was averagely varied in the range from 0.1 m to 2.65 m at the height of underground reservoirs. If considered actual height of underground reservoirs, 37.6 percent of the height of underground reservoirs was only used. Consequently, the frequency of the inflow and outflow of drinking water in underground reservoir were very increased, and had an effect on the reduction of residual chlorine. Lastly, the investigations on hydraulic structure characteristics of underground reservoirs inside showed the locations of inflow and outflow of drinking water almost were in the opposite direction. And some buildings had several baffles in the middle. Nevertheless, their installations had no beneficial for the improvement of water quality.