Browse > Article

Assessment of Hydraulic Behavior and Water Quality Variation Characteristics in Underground Reservoir  

Lee, H.D. (Korea Institute of Construction Technology Construction Environment Research Dept.)
Bae, C.H. (Korea Water Resources Corporation Korea Ins. of Water & Env. Dept.)
Kim, J.H. (Korea Water Resources Corporation Korea Ins. of Water & Env. Dept.)
Hwang, J.W. (Korea Institute of Construction Technology Construction Environment Research Dept.)
Hong, S.H. (Soongsil University Chemical & Environmental Engineering)
Publication Information
Abstract
The assessment on characteristics of hydraulic behavior and water quality variations of underground reservoirs of buildings were studied. Firstly, it was thought that underground reservoir capacities($m^3$) of buildings should be not determinated by the uniform and same methods but be estimated on the basis of the dwelling areas on dominated households and their residential characteristics, because these characteristics influence significantly on actual water usages and patterns of buildings. Secondly, it was likely that the average reduction rate of residual chlorine in underground reservoirs were affected from the their capacities, because the average reduction rate of residual chlorine in underground reservoirs under $1,000m^3$ was 43 percent, on the other hand, that rate of underground reservoirs over $1,000m^3$ was 60 percent. Thirdly, through the field investigation, the retention time of drinking water in underground reservoirs were in the range from 0.3 day to 3.9 day. In addition to, the average reduction rate of residual chlorine were depended largely on the retention time of drinking water. When the retention time was under 24 hours, the average reduction rate of residual chlorine was 45 percent, and in case of over 24 hours, was 49 percent. Fourth, water level in underground reservoirs was averagely varied in the range from 0.1 m to 2.65 m at the height of underground reservoirs. If considered actual height of underground reservoirs, 37.6 percent of the height of underground reservoirs was only used. Consequently, the frequency of the inflow and outflow of drinking water in underground reservoir were very increased, and had an effect on the reduction of residual chlorine. Lastly, the investigations on hydraulic structure characteristics of underground reservoirs inside showed the locations of inflow and outflow of drinking water almost were in the opposite direction. And some buildings had several baffles in the middle. Nevertheless, their installations had no beneficial for the improvement of water quality.
Keywords
Underground reservoir; Hydraulic behavior; Residual chlorine; Retention time;
Citations & Related Records
연도 인용수 순위
  • Reference
1 이현동, 배철호, 박정훈, 홍성호, 건축물내 노후급수관의 직 접진단에 의한 상태 평가, 한국물환경학회지, 18(5), pp 535-544 (2002b)
2 이현동, 황재운, 배철호, 김상진, 건축물내 급수설비의 수질 변화 특성과 영향력 평가, 한국물환경학회지, 20(4), pp. 313-320 (2004)
3 환경부, 수도시설의 청소 및 위생관리 등에 관한 규칙 제 3 조, 제 15659호 (1998)
4 Lee, H. D., Bae, C. H., Park, J. H., Koo, J. Y., Effects of water quality characteristics on the internal corrosion of galvanized steel pipes in Korean , 弟36回 日本水環境學論硏 集(2002)
5 주택건설기준 등에 관한 규정, 제35조 비상급수시설 2항, 대통령령 제 18372호 (2002)
6 조용모, 조학문, 임경미, 양경수, 이혜영, 수요자 급수시설의 수질관리를 위한 연구, 서울시정개발연구원, pp. 13-18 (2002)
7 이목영, 장현정, 이의광, 오세종, 이채근, 이현동 옥상물탱크 경유에 따른 수돗물 변화 및 직결급수방식 도입에 의한 수질개선 효과 연구, 대한상하수도학회지, 14(4), pp 328-336 (2000)
8 이현동, 배철호, 박정훈, 정원식, 곽필재, 수돗물의 수질특성 이 옥내 급수관의 부식속도에 미치는 영향 평가, 한국물환경학회지, 17(5), pp. 627-635 (2001)
9 이현동, 배철호, 박정훈, 옥내급수관의 통수년수별 간접진단 평가, 수처리기술연구회지, 10(2), pp. 25-37 (2002a)
10 건설교통부, 상수도시설기준 (1997)