• 제목/요약/키워드: Results of Floor noise Source

검색결과 46건 처리시간 0.025초

바닥 충격음 평가를 위한 고무공 충격원의 특성 (Characteristics of a Rubber-Ball Impactor to Evaluate Floor Impact Noise)

  • 문형준;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.592-597
    • /
    • 2002
  • The purpose of this study was to analyze the characteristics of a new heavy weight impactor, the Rubber Ball. Until now Bang-machine has been used to measure the heavy impact noise in accordance with JIS A 1418-1. However, various kinds of examination methods have been needed to make an objective observation of insulation capacity for floor impact noises. Two types of experiments were undertaken. First, the experiment about noise was carried out about an apartment building in actual living condition. Then. vibration noises from the impactors were analyzed. The results of this study were as follows : the result of experiment carried out with bonded area of bail was closer to practical experiment than that of non bonded area. In addition, the result about bonded area of ball was more similar to the result which is claimed by H. Tachibana than that about non bonded area. Moreover, it was found that Rubber Ball has more similar vibration characteristics to the real impact noise source than Bang-machine.

  • PDF

실충격원을 고려한 바닥충격음 저감방안의 평가 (Evaluations on isolation method of floor impact sounds by real impact source)

  • 유승엽;이평직;정영;전진용;류종관
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.366-370
    • /
    • 2006
  • In this study, characteristics of impact force and impact sound of impact source such as bang machine, impact ball, and children's jumping were review. Results of review showed that impact ball has most similar characteristic to real impact sources in terms of objective properties such as impact force and impact sound. The effects of various isolator on floor impact sound were also investigated in apartment building and test facilities building using bang machine an impact ball. From the field measurement, it was found that the difference in reduction sound level between bang machine and impact ball was relatively large and the reduction sound level by impact ball was much larger than bang machine.

  • PDF

중량충격원 충격에 따른 공동주택 실내공간의 구조음장 해석 모델링방법에 관한 연구 (A Study on the Structural-acoustic Analysis Modeling Methods of the Room with Heavy Impact Noise Source)

  • 이재광;구해식
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of the present study is to establish structural noise analyzing method for apartments building floor with structural-acoustic coupling analysis modeling. Noise through floor in the room is recognized as a significant problem with the consequence that noise isolation technique has been studied in the various fields of industry. From among noise factors, resonance sound is the main reason for solid noise of the floor, which is occurred by mechanical vibrations of the acoustic boundary line and the change of velocity. To analyse this phenomenon, numerical computation methods are provided in many fields, In this study, evaluation method for slab is established using finite element method, and a case study for analyzing acoustic phenomenon was suggested. The results show that numerical method, especially F.E.M, has a good approximation to predict noise at floors.

강재프레임 모듈러주택의 바닥충격음 성능평가 (Performance Evaluation of the Floor Impact Sound Insulation in Steel Framed Modular House)

  • 천영수;방종대;김갑득;유송이
    • 토지주택연구
    • /
    • 제5권2호
    • /
    • pp.81-89
    • /
    • 2014
  • 이 논문에서는 최근 관심을 모으고 있는 강재프레임 모듈러주택의 건식 바닥시스템을 대상으로 바닥충격음 차단성능을 확보하기 위하여 시도된 다양한 바닥구조의 실험결과에 대하여 제시하고 있다. 실험결과, 단위모듈 건식온돌 바닥구조는 완충구조로서 액체몰을 사용한 바닥구조 D31(D32)를 사용하는 조건에서 경량충격음의 경우 주택건설기준 등에 관한 규정에서 정하고 있는 바닥충격음 차단성능의 1등급 수준의 확보가 가능하고, 중량충격음의 경우는 바닥충격음 차단성능의 최저등급이기는 하나 기본적인 성능의 확보가 가능한 것으로 평가되었다.

중량충격원에 따른 콘크리트 바닥판의 차음특성 분석 및 평가에 관한 연구 (Analysis and Evaluation of Impact Sound Insulation of Concrete Floor Structures in Response to Characteristics of Heavy-weight Impact Sources)

  • 유승엽;연준오;전진용
    • 한국소음진동공학회논문집
    • /
    • 제19권10호
    • /
    • pp.1062-1068
    • /
    • 2009
  • In this study, the impact force levels of bang machine and impact ball were measured, then the heavy-weight impact sounds generated by the bang machine and impact ball were investigated. It was found that the heavy-weight impact sources generated through modal excitation, and the impact force of the impact ball was similar to that of real impact source. The heavy-weight impact sounds were also measured in the real apartments with different slab thickness and floor structures. The results showed that the floor impact sound levels in terms of $L_{iFmax,AW}$, generated by impact ball sounds were reduced by using the resilient isolators. The frequency characteristics of heavy-weight impact sounds at 125 and 250 Hz were consistent with the characteristics of impact force spectrum. However, the difference between the impact sounds and the impact forces were found at 63 and 500 Hz due to the resonance of the floor structure and flanking noise, respectively.

중량 바닥충격음 예측을 위한 진동 전달률 산정 연구 (Assessment of Vibration Transmissibility for Prediction of Heavy Floor Impact Sound)

  • 김하근;김명준;오양기
    • 한국소음진동공학회논문집
    • /
    • 제13권6호
    • /
    • pp.415-422
    • /
    • 2003
  • In an apartment buildings, the floor Impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation, it is necessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to suggest the supplementary formula(equation) and constant k considering vibration transmissibility in order to predict more precisely heavy floor impact sound by Impedance Method that have been briskly studied in Japan from comparing the measured values with the predicted values. The analyzed results had showed that if the damping material was glass wool or rubber, k=5 was proper and if the damping material was polystyrene foam, k>5 was desirable.

모의실험을 통한 완충재별 진동전달량과 동적특성과의 상관성 분석에 관한 연구 (Analysis of Correlation between the Vibration Transmissions and the Dynamic Characteristics for Floor Impact Sound Insulation Materials through Model Test)

  • 김흥식;주시웅;진필화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1425-1431
    • /
    • 2006
  • In this study, An analysis of correlation between the vibration transmissions and the dynamic characteristics for floor impact sound insulation materials through model test was carried out. As the results, the correlation coefficients between the vibration transmissions and the dynamic characteristics for floor impact sound insulation materials were over 0.8 at the heavy and light floor impact source and less dynamic stiffness was more effective in reducing the vibration transmission.

  • PDF

층간소음 관리시스템이 민원저감과 아파트 가격에 미치는 영향 (Effect of the Trend fo Civil Complaint and Apartment Price at Management System of Floor Noise at Houses)

  • 차상곤;김현주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.704-709
    • /
    • 2014
  • 본 연구는 현재 사회문제화 되고 있는 층간소음 피해 실태조사 분석을 통하여 적용 가능한 층간소음 분쟁의 예방을 위한 효율적인 관리시스템을 개발 적용하였다. 설문조사 분석결과, 층간소음의 주요 발생 원인으로 아이들 뛰는 소음과 어른 걷는 소음이 55% ~ 75%로 가장 심각한 소음원으로 나타났으며, 소음 피해시간대는 저녁(18시~22시) 시간대는 50% ~ 65%로 가장 높게 나타났으며, 야간(22시~ 06시) 시간대는 26% ~ 45%범위에 있는 것으로 분석되었다. 층간소음관리시스템 적용 전 후의 민원저감효과 분석결과, 전라도 광주는 100%, 대구시는 87.5%, 서울의 경우는 83%, 경기도는 71% 순으로 나타나, 평균 약 85% 이상의 민원 저감효과가 있는 것으로 나타났다. 층간소음관리시스템 적용 전 후의 아파트 가격 변화 분석결과, 적용된 아파트의 경우는 평균 17.23백만원 상승한 반면, 미적용된 아파트는 0.55백만원 하락한 것으로 평가되었다.

  • PDF

공동주택 층간소음 해결을 위한 현장관리시스템과 그 효과 (The Management System and Effect of Floor Noise at Apartment Houses)

  • 차상곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.693-697
    • /
    • 2014
  • 본 연구는 민원인(아래층)과 피민원인(윗층)간 전문상담사의 중재를 통해 층간소음 문제를 해결하는 층간소음 현장관리시스템의 실효성을 검증하였다. 민원인(아래층)과 피민원인(위층)의 층간소음 피해경향을 분석한 결과, 4,087건 중 80%에 해당하는 3,254건의 민원인들은 층간소음 발생장소를 바로 윗층을 지목하는 것으로 나타났고, 반면에 15%에 해당하는 피민원인들(윗층)은 피해를 받는 원인이 소음이 아니라 피민원인의 전화나 방문 등을 통한 잦은 항의를 지적하는 것으로 분석되었다. 1,304건의 현장 방문 민원건수 중 80%에 해당하는 1,050건을 대상으로 현장방문 컨설팅 전 후의 층간소음 저감 등 만족도 조사결과, 약 683건에 해당하는 65%정도의 민원인은 층간소음 현장관리시스템에 만족하고 있는 것으로 평가되었다.

  • PDF

설문조사와 청감실험을 통한 공동주택 차음성능의 평가등급 설정 (Classification of Noise Insulation Performance in Apartment Buildings through Noise survey and Auditory Experiment)

  • 류종관;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.666-669
    • /
    • 2005
  • Social noise survey and auditory experiment on residential noises such as floor impact, air-borne, bathroom, drainage and traffic noises were conducted to classily a noise insulation Performance in apartment building. The survey results showed that annoyance among subjective responses to residential noises was most greatly affecting to satisfaction with noises. In the survey, boundary limit between satisfaction and dissatisfaction was also determined. Auditory experiments was also undertaken to determine noise insulation performance according to the percent of satisfaction for individual noise source. Result of auditory experiment showed that the noise insulation performance for floor impact, airborne, drainage and traffic noise corresponding to 40 % satisfaction is 49 dB (L$_{i,Fmax,AW}$), 48 dB (R'w), N-41, and N-40, respectively. Finally, classes of noise insulation performance in apartment building were proposed according to satisfaction with noises

  • PDF