• 제목/요약/키워드: Response correction factor

검색결과 96건 처리시간 0.03초

Characteristics of a High Power Factor Boost Converter with Continuous Current Mode Control

  • Kim, Cherl-Jin;Jang, Jun-Young
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권2호
    • /
    • pp.65-72
    • /
    • 2004
  • Switching power supply systems are widely used in many industrial fields. Power factor correction (PFC) circuits have a tendency to be applied in new power supply designs. The input active power factor correction (APFC) circuits can be implemented in either the two-stage approach or the single-stage approach. The two-stage approach can be classified into boost type PFC circuit and dc/dc converter. The power factor correction circuit with a boost converter used as an input power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, the regulation performance of output voltage and compensator to improve the transient response presented at the continuous conduction mode (CCM) of the boost PFC circuit is analyzed. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results.

Development of nationwide amplification map of response spectrum for Japan based on station correction factors

  • Maruyama, Yoshihisa;Sakemoto, Masaki
    • Earthquakes and Structures
    • /
    • 제13권1호
    • /
    • pp.17-27
    • /
    • 2017
  • In this study, the characteristics of site amplification at seismic observation stations in Japan were estimated using the attenuation relationship of each station's response spectrum. Ground motion records observed after 32 earthquakes were employed to construct the attenuation relationship. The station correction factor at each KiK-net station was compared to the transfer functions between the base rock and the surface. For each station, the plot of the station correction factor versus the period was similar in shape to the graphs of the transfer function (amplitude ratio versus period). Therefore, the station correction factors are effective for evaluating site amplifications considering the period of ground shaking. In addition, the station correction factors were evaluated with respect to the average shear wave velocities using a geographic information system (GIS) dataset. Lastly, the site amplifications for specific periods were estimated throughout Japan.

의사정적재하시험 응답보정계수에 의한 교량 해석모델 보정의 타당성 분석 (Feasibility Analysis of the Bridge Analytical Model Calibration with the Response Correction Factor Obtained from the Pseudo-Static Load Test)

  • 한만석;신수봉
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.50-59
    • /
    • 2021
  • 현재 공용중인 교량에 대한 재하시험으로 계측한 응답과 초기해석모델의 해석 응답을 비교하여 응답보정계수를 계산하고, 이 모델을 사용하여 내하율과 내하력을 평가하는 방법을 적용하고 있다. 그러나 이러한 응답보정계수는 계측 위치와 하중 조건에 따라 변동하는 값을 준다. 특히 초기해석모델이 교량의 거동에 합당하지 않은 경우, 그 변동 폭이 크며 보정된 모델에 의한 해석 응답이 계측된 응답과 동떨어진 결과를 줄 수 있다. 본 연구에서는 저속으로 주행하는 차량의 다양한 하중 조건에서 동적 성분을 제거한 정적 응답을 얻기 위해 의사정적재하시험법을 적용하였다. 두 개의 유사한 PSC-I 거더교에서 정적 응답을 계측하고, 두 교량 각각에 대한 변위와 변형률에 대한 응답보정계수를 계산하였다. 초기해석모델이 제대로 설정되어 있지 않다면, 평균적으로 구한 응답보정계수로 보정한 모델의 해석 응답이 계측 응답과 오차범위 내에 들어오는지 않음을 확인하였다.

RW3 고체팬텀에서 고에너지 X-선에 대한 전리함 반응보정인자의 특성에 관한 연구 (Study on the Characteristics of Response Correction Factor of Ionization Chamber in RW3 Solid Phantom for High Energy X-rays)

  • 이정옥;정동혁;김부길
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권2호
    • /
    • pp.205-212
    • /
    • 2009
  • 반응보정인자(h)는 고체팬텀에서 전리함의 반응을 물에서의 값으로 변환하기 위한 인자이다. RW3 고체 팬텀의 경우에 고에너지 X-선에 대한 반응보정인자는 선질과 깊이에 의존하는 것으로 알려져 있으나 조사면 크기와 SSD(Source to surface distance), 그리고 전리함 종류에 따른 의존성은 알려진 바가 없다. 본 연구에서는 알려진 의존성을 고찰하고 알려지지 않은 인자들에 대한 의존성을 조사하였다. 본 측정에서는 파머형전리함(FC65G, IBA, Germany)과 소형전리함(CC13, IBA, Germany)이 사용되었으며 대상 선질은 6 MV와 15 MV X-선이었다. 측정 결과 반응보정인자는 6 MV의 경우에 깊이 5 cm와 10 cm에서 각각 h = 1.015, 1.021, 그리고 15 MV의 경우에 깊이 5와 10 cm에서 각각 h = 1.024, 1.029로 나타났다. 결론적으로 반응보정인자는 선질과 깊이에는 의존하였지만 조사면 크기와 SSD에 따른 변화는 적었다. 전리함에 있어서 대상의 두 전리함에 대해서는 차이가 없었으나 다른 종류의 전리함에 대해서 추가적 연구가 필요하다고 생각한다. 본 결과는 RW3에서 전리함을 이용한 측정시 측정값의 분석에 활용될 수 있다.

  • PDF

부하변동에 속응하는 역률개선형 전력절감시스템 (Electric energy saving system with high speed response to load variation using power-factor correction)

  • 김태수;강형식;주경돈;류승헌;구경완;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2388-2390
    • /
    • 2002
  • Small type electric energy saving system is proposed in this paper. The system improves power factor fastly according to load variation of each customer. Phases of voltage and current are detected as 1[ms] unit. Phase coincident algorithm is applied for power factor improvement. Capacitance is controlled for optimal power factor correction. Series reactor is controlled for harmonics reduction. Non-contact device is used for fast response and long life. Test result shows the effect of this system. Power factor of 40[W] electric fan is improved from 95[%] to 100[%]. In the case of electric light, power factor is improved from 82[%] to 100[%]. Response time for load variation is less than 1[ms].

  • PDF

전압제어루프를 고려한 부스트방식 역률개선회로의 안정도에 관한 연구 (A Study on the stability of boost power factor correction circuit with voltage feedback loop)

  • 김철진;장준영;지재근;송요창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.271-273
    • /
    • 2002
  • Switching power supply are widely used in many industrial field. Power factor correction(PFC) has become an increasingly necessary feature in new power supply designs. The power factor correction circuit using boost converter used in input of power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, it is analyzed regulation performance of output voltage and compensator to improve of transient response that presented at continuous conduction mode(CCM) of boost PFC circuit. The validity of designed boost PFC circuit is confirmed by simulation and experimental results.

  • PDF

역V형 가새골조의 반응수정계수 (The Response Modification Factor of Inverted V-type Braced Steel Frames)

  • 안형준;김송매
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.1-9
    • /
    • 2013
  • 철골구조에서 지진력 저항시스템으로 많이 사용되고 있는 가새골조시스템은 중심가새골조(Concentrically Braced Frames, CBF)와 편심가새골조(Eccentrically Braced Frames, EBF)로 구분하여 KBC2009 건축구조기준에서는 서로 다른 반응수정계수를 적용하여 설계하도록 되어있다. 현행 내진설계기준에서 편심가새골조에 대하여 링크 타단 접합부의 종류에 따라 모멘트 저항접합일 경우 반응수정계수는 R=8, 비모멘트 저항접합일 경우 반응수정계수 R=7로 적용하여 설계하도록 규정하고 있을 뿐 편심길이의 영향을 고려하지 않고 있다. 본 연구에서는 편심가새골조 중에서 역V형가새골조를 대상으로 비탄성 거동을 파악한 다음 편심길이에 따른 반응수정계수를 산정하여 내진설계 기준에서 제시한 값과 비교한 결과 편심가새골조에 대하여 동일한 반응수정계수를 적용하는 것은 적절하지 않음을 확인하였다.

A complete 3D map of Bell Glasstone spatial correction factors for BRAHMMA subcritical core

  • Shukla, Shefali;Roy, Tushar;Kashyap, Yogesh;Shukla, Mayank;Singh, Prashant
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3488-3493
    • /
    • 2022
  • Accelerator driven subcritical systems have long been discussed as facilities which can be used for solving the nuclear waste problem. The physics of these systems is very different from conventional reactors and new techniques had to be developed for reactivity monitoring. One such technique is the Area Ratio Method which studies the response of a subcritical system upon insertion of a large number of neutron pulses. An issue associated with this technique is the spatial dependence of measured reactivity which is intrinsic to the sub criticality of the system since the reactor does not operate on the fundamental mode and measured reactivity depends on the detector position. This is generally addressed by defining Bell-Glasstone spatial correction factor. This factor upon multiplication with measured reactivity gives the correct reactivity which is independent of detector location. Monte Carlo Methods are used for evaluating these factors. This paper presents a complete three dimensional map of spatial correction factors for BRAHMMA subcritical system. In addition, the dataset obtained also helps in identifying detector locations where the correction factor is close to unity, thereby implying no correction if the detector is used at those locations.

PFC 및 CCR에 의한 항공조명용 전원공급장치의 개발 (A Power Supply System for Lighting of Aerodromes by Using Power Factor Correction and Constant Current Regulator)

  • 손진근
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2150-2156
    • /
    • 2007
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. But, problems that power factor deterioration and fast response of control, efficiency, harmonics and etc are still remain. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for lighting and beaconing of aerodromes. The effectiveness of the proposed system confirmed through experimental results of 10[kW] power supply system.

입력 능동 부스트 컨버터를 고려한 역률개선회로의 특성분석 (A study on the characteristics of power factor correction circuits with input active boost converter)

  • 장준영;이관용;김철진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.270-272
    • /
    • 2003
  • Switching power supplies are widely used in many industrial fields. Power factor correction(PFC) circuits have tendency to be applied in new power supply designs. The input active power factor correction(APFC) circuits can be implemented using either the two-stage approach or the single-stage approach. The single-stage PFC circuit has advantage to reduce the number of components by eliminating a need for the PFC switch and control circuit. However, unlike in the two-stage approach, the do voltage on the energy storage capacitor in a single-stage PFC circuit is not well regulated. As a result. in universal line application($90{\sim}265Vac$), the storage capacitor voltage varies with the load and line variation. In this paper, the performance of output voltage regulation and transient response are clarified here. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results of 2 [kW] prototype converter.

  • PDF