• Title/Summary/Keyword: Response Measurement Point

Search Result 159, Processing Time 0.035 seconds

The Pulmonary Function and Heart Rate Recovery Response of Smoker and Nonsmoker in Males Aged 20s after Graded Maximal Exercise (최대부하운동 후 20대 남성 흡연자와 비흡연자의 폐기능과 심박수 회복 반응)

  • Kim, Eun-Jung
    • Journal of Korean Physical Therapy Science
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Purpose : The purpose of this study was to investigate the response of pulmonary function and heart rate recovery of smoker and nonsmoker in males aged 20s after graded maximal exercise. Method : The subjects were composed of smoker group (n=12) and nonsmoker group (n=12) in males aged 20s. Each groups completed an graded maximal exercise with Bruce protocol and were assessed on the pulmonary function(forced vital capacity : FVC, forced expiratory volume-one second : FEV1, FEV1/FVC) and heart rate. Result : The results were as follows: First, heart rate in the measurement point was a statistically significant difference for smoker and non-smoker group after maximal exercise, but FVC, FEV1, FEV1/FVC was no difference. Second, FEV1/FVC between smoker and nonsmoker group was a statistically significant difference after maximal exercise, but FVC, FEV1, heart rate was no difference. Conclusion : The results of this study is that smoking is negative effects on FEV1/FVC of pulmonary function in males aged 20s after maximal exercise.

  • PDF

Vibration fatigue prediction using design sensitivity analysis (설계 민감도 해석을 활용한 진동내구 예측방법 연구)

  • Kim, Chan-Jung;Ju, Hyung-Jun;Shin, Sung-Young;Kwon, Sung-Jin;Lee, Bong-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.488-493
    • /
    • 2011
  • Authors previously suggested the design sensitivity analysis based on transmissibility function and identified the sensitivity of measured point over the small modification of system dynamics. On the other hand, the acceleration data will not reveal the strain information at the same location and authors suggested energy isoclines that successfully predict the fatigue damage on the interesting location to overcome the drawback of acceleration over fatigue society. Both of methodologies, sensitivity analysis and fatigue damage prediction, commonly use the response acceleration response as main indicator. In this paper, authors investigate the advanced method of vibration fatigue prediction using design sensitivity analysis to enhance the accuracy of predicted accumulated fatigue. Uni-axial vibration testing is performed with finite element model of a simple notched specimen and the prediction of fatigue damage at notched location is conducted for accelerations at different measurement locations that show different sensitivity contribution, either.

  • PDF

Gas Response and Electrical Properties of Organic Ultra-thin Films (유기 박막의 전기적 특성 및 가스 반응 특성)

  • 박재철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.820-825
    • /
    • 1998
  • We deposited stearic acid LB films by using Langmuir-Blodgett (LB)method and investigated anisotropy electrical conduction characteristics by I-V measurement for horizontal direction and vertical direction. Also, we measured gad response between deposited LB films and organic gas for various temperature(0~8$0^{\circ}C$) by 9MHz At-cut quartz crystal microbalance. The LB films have electrical conduction characteristics such as semiconducting and insulating properties. The is, the conductivity of LB films for the horizontal and vertical direction is about 10\ulcornerS/cm and 10\ulcorners/cm, respectively. the frequency shift of stearic acid LB films for the organic gases depended on the mass change by the surface adsorption and the inner penetration to the sensing films. The resonant frequency shift of the quartz crystal microbalance for temperature properties of LB films is thought to the effect of the rearrangement or the damage pf LB films above the melting point and the mobility increasement of the organic gas by the temperature rising.

  • PDF

Disposable Strip-Type Biosensors for Amperometric Determination of Galactose

  • Gwon, Kihak;Lee, Seonhwa;Nam, Hakhyun;Shin, Jae Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.310-317
    • /
    • 2020
  • A development of disposable strip-type galactose sensor for point-of-care testing (POCT) was studied, which was constructed using screen-printed carbon electrodes. Galactose levels were determined by the redox reaction of galactose oxidase in the presence of potassium ferricyanide as an electron transfer mediator in a small sample volume (i.e., less than 1 µL). The optimal performance of biosensor was systematically designated by varying applied potential, operating pH, mediator concentration, and amount of enzyme on the electrode. The sensor system was identified as a highly active for the galactose measurement in terms of the sensitivity (slope = 4.76 ± 0.05 nA/µM) with high sensor-to-sensor reproducibility, the linearity (R2 = 0.9915 in galactose concentration range from 0 to 400 µM), and response time (t95% = <17 s). A lower applied potential (i.e., 0.25 V vs. Ag/AgCl) allowed to minimize interference from readily oxidizable metabolites such as ascorbic acid, acetaminophen, uric acid, and acetoacetic acid. The proposed galactose sensor represents a promising system with advantage for use in POCT.

Optimal Tuning Strategy for 2-Degree-of-Freedom i-PID Controllers (2 자유도 지적 PID 제어기의 파라미터 설정)

  • Choe, Yeon-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1202-1209
    • /
    • 2018
  • This paper is concerned with the problem of setting controller's parameters when applying the intelligent PID (i-PID), which has recently been proposed and had many successful results, to the two-degree-of-freedom (2DoF) PID controller structure. Generally, the parameter settings of conventional PID controllers are known to be quite difficult and be dependent on the characteristics of the plants. In addition, it is less known how the two 2DoF parameters are set up for the improvement of transient characteristics. Here, we are going to present one of the criteria for parameter setting in the case of using a 2DoF i-PID, by evaluating the error signals to the set-point and disturbance. That is, we first, obtain parameters of i-PID by optimizing the disturbance responses, and then determine two parameters of 2DoF component through optimizing set-point response. The standard values of all parameters are calculated for the 7 types of test batches and rounded up as a table.

Implementation on the Portable Blood Gas Analyzer and Performance Estimation (휴대형 혈액가스분석 시스템의 구현 및 성능평가)

  • Jeong, Do-Un;Jeon, Gye-Rok;Bae, Jin-Woo;Kim, Gil-Jung;Sim, Yoon-Bo
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.34-43
    • /
    • 2003
  • In this study, we implemented the measurement of pH, $pO_2$, $pCO_2$ of the arterial blood on a portable blood gas analysis system. This system is consist of two parts of hardware and software. The hardware part is divided into a fluidic mechanism and an electronic circuit unit. The system program is composed of operating, washing, correcting, and measuring routines. Both of 1-point and 2-point calibration schemes were used to enhance the accuracy of the measurement. In order to evaluate the performance of the developed system, we measured and performed statistical analysis on the characteristics of the sensing electrode response. As a result, coefficient variation was within 1.12, and maximum error was within 1.298%. We confirmed development possibility of portable blood gas analyzer.

A pilot study on measuring the human cortisol using an electronic device (전자소자를 이용한 인간 감성지표 코티졸 검출에 관한 기초연구)

  • Lee, Hee-Jo;Lee, Jung-Hyun;Hwang, Yoo-Sun;Jung, Hyo-Il
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.531-536
    • /
    • 2011
  • The precise measurement of human emotion is of pivotal importance in the field of emotion science. Based on the perspective of psychoneuroimmunoendocrinology, human emotion is now considered to be measurable by body fluid. The biological molecule cortisol, which is known for the stress hormone, has been widely investigated to help researchers to estimate the stress loaded on human body. Until now, several measurement techniques such as High Performance Liquid Chromatography (HPLC), fluorometric assay, and reverse phase chromatography have been developed. However, since these measurements are expensive, take relatively long time for an operation, and they are not portable, they are not appropriate for POCT (point of care testing). In this paper we demonstrate the performance of a miniaturized-microwave resonant device in the measurement of cortisol. Our method has many advantages in that it requires a small volume of sample, has fast response time, is easy to operate and needs no labeling process. Besides, it will shed a light on the measurement techniques for emotion science.

  • PDF

Wavelet analysis based damage localization in steel frames with bolted connections

  • Pnevmatikos, Nikos G.;Blachowski, Bartlomiej;Hatzigeorgiou, George D.;Swiercz, Andrzej
    • Smart Structures and Systems
    • /
    • v.18 no.6
    • /
    • pp.1189-1202
    • /
    • 2016
  • This paper describes an application of wavelet analysis for damage detection of a steel frame structure with bolted connections. The wavelet coefficients of the acceleration response for the healthy and loosened connection structure were calculated at each measurement point. The difference of the wavelet coefficients of the response of the healthy and loosened connection structure is selected as an indicator of the damage. At each node of structure the norm of the difference of the wavelet coefficients matrix is then calculated. The point for which the norm has the higher value is a candidate for location of the damage. The above procedure was experimentally verified on a laboratory-scale 2-meter-long steel frame. The structure consists of 11 steel beams forming a four-bay frame, which is subjected to impact loads using a modal hammer. The accelerations are measured at 20 different locations on the frame, including joints and beam elements. Two states of the structure are considered: healthy and damaged one. The damage is introduced by means of loosening two out of three bolts at one of the frame connections. Calculating the norm of the difference of the wavelet coefficients matrix at each node the higher value was found to be at the same location where the bolts were loosened. The presented experiment showed the effectiveness of the wavelet approach to damage detection of frame structures assembled using bolted connections.

Development of EIS Evaluation Method about PEMFC 1kW STACK (가정용 연료전지 스택의 EIS 평가 기법 개발)

  • Park, Chaneom;Han, Woonki;Jung, Jinsu;Ko, Wonsik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.100.1-100.1
    • /
    • 2011
  • Electrochemical impedance spectroscopy(EIS) are using widely as a useful technique mainly in the field of electrochemical for the analysis of electrode reactions or characteristics of the composites. The response analysis of the systems technique provides comprehensive informations about the characteristic and structure of complex and internal reaction. The EIS is the method to measure impedance of the measurement target classified by the frequency, it select the equivalent impedance model to give same response from the result and it calculate the parameter. Therefore, the chemical reaction inside the fuel cell is to modeling to electrical impedance. And as repeating the same experiment in each of the operating point, we can get each different parameter. As a result, we can establish the equivalent impedance model in each operating point. Therefore, if we use these models, we can evaluate the fuel cell without the internal design parameter of the fuel cell as required in existing modeling. The EIS is used typically technique for distinguish status of fuel cell called SOH(State Of Health). When the fuel cell is degradation, Efficiency and health of the fuel cell is reduced because internal impedance is increase. As usage of these principles, we can evaluate state of fuel cell through the impedance analysis of fuel cells. In this study, we are presents EIS distinction system and algorithm for residential fuel cell systems. At the time of the fuel cell installation in the fields, the EIS system and proposed algorithm will be able to apply as technique for efficiency and performance evaluation about fuel cell system.

  • PDF

Analysis of Frequency Response Characteristics in Optical Microphone (광 마이크로폰의 주파수 응답특성 분석)

  • Yeom, Keong-Tae;Kim, Kwan-Kyu;Heh, Do-Geun;Kim, Yong-Kab
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.6
    • /
    • pp.8-15
    • /
    • 2008
  • In this paper, in order to analyze property of frequency response in optical microphone, system was implemented. The capacitance microphone and fiber-optic transmission path type fiber-optic microphone (FOM) have weaknesses in directivity, size, weight, and price. However suggested optical microphone can be constituted by cheap devices, so it has many benefits like small size, light weight, high directivity, etc. Head part of optical microphone which is suggested in this paper is movable back and forth by sound pressure with the attached reflection plate. Operating point is determined by measuring the respond characteristics and choosing the point on which has maximum linearity and sensitivity while changing the distance between optical head and vibrating plate. We measured the output of the O/E transformed signal of the optical microphone while frequency of sound signal is changed using sound measurement/analysis program, Smaart Live and USBPre, which are based on PC, and compared the result from an existing capacitance microphone. The measured Optical microphone showed almost similar output characteristics as those of the compared condenser microphone, and its bandwidth performance was about 300[Hz]-3[kHz] at up to 3 [dB].