• Title/Summary/Keyword: Resonant Sensors

Search Result 110, Processing Time 0.024 seconds

Real-time Blood Pressure Monitoring in Porcine Tibial Artery Using LC Resonant Pressure Sensor (LC 공진형 압력 센서를 이용한 돼지 경골 동맥의 실시간 혈압 측정)

  • Choi, Won-Seok;Kim, Jin-Tae;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.445-450
    • /
    • 2012
  • We have developed an implantable wireless sensor for real time pressure monitoring of blood circulation system. MEMS (micro-electro-mechanical system) technology was adopted as a sensor development method. The sensor is composed of photolithographically patterned inductors and a distributed capacitor in gap between the inductors. A resulting LC resonant system produces its resonant frequency in range of 269 to 284 MHz at 740 mmHg. To read the resonant frequency changed by blood pressure variation, we developed a custom readout system based on a network analyzer functionality. The bench-top testing of the pressure sensors showed good mechanical and electrical functionality. A sensor was implanted into tibial artery of farm pig, and interrogated wirelessly with accurate readings of blood pressure. After 45 days, the sensor's electrical response and histopathology were studied with good frequency reading and biocompatibility.

Design Criteria of the Auxiliary Resonant Snubber Inverter Using a Load-Side Circuit for Electric Propulsion Drives

  • Song, Byeong-Mun;Jih-Sheng(Jason) Lai;Kwon, Soon-Kurl
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.143-148
    • /
    • 1998
  • The Design criteria of the auxiliary resonant snubber inverter (ARSI) using a load-side circuit are discussed in relation to electric propulsion drives. In this regard, this paper attempts to develop a set of design criteria for the ARSI. First, the switching characteristics of IGBTs under soft-switching mainly in terms of dv/dt/, di/dt and switching losses are discussed and utilized for optimizing the selection of the resonant components in the system. After that, the proper control strategies of ARSIs are analyzed and simulated based on voltage space vector modulations. Later, the design, control and implementation of the auxiliary resonant circuit suitable for industrial products are analyzed and presented. And finally, other factors including power stage layout, packaging and the choice of current sensors are included. The detailed simulation and experimental results will be included based on a laboratory prototype. The proposed design criteria of the ARSI would help the implementation of an electric propulsion drive system.

  • PDF

Development of a MEMS Resonant Accelerometer Based on Robust Structural Design (강건 구조설계에 기반한 미소 공진형 가속도계의 개발)

  • Park, U-Sung;Boo, Sang-Pil;Park, Soo-Young;Kim, Do-Hyung;Song, Jin-Woo;Jeon, Jong-Up;Kim, Joon-Won
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.114-120
    • /
    • 2012
  • This paper describes the design, fabrication and testing of a micromachined resonant accelerometer consisting of a symmetrical pair of proof masses and double-ended tuning fork(DETF) oscillators. Under the external acceleration along the input axis, the proof mass applies forces to the oscillators, which causes a change in their resonant frequency. This frequency change is measured to indicate the applied acceleration. Pivot anchor and leverage mechanisms are adopted in the accelerometer to generate larger force from a proof mass under certain acceleration, which enables increasing its scale factor. Finite element method analyses have been conducted to design the accelerometer and a silicon on insulator(SOI) wafer with a substrate glass wafer was used for fabricating it. The fabricated accelerometer has a scale factor of 188 Hz/g, which is shown to be in agreement with analysis results.

A Study on the Technology Diagnosing Particles with Two Acoustic Emission Sensors Which have the Different Characteristics of Frequency in GIS (주파수특성이 다른 2개의 초음파 친서에 의한 GIS 이물진단 기술 연구)

  • 김광화;최재구;선종호;김익수;윤진열
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.5
    • /
    • pp.219-225
    • /
    • 2003
  • This paper described about the acoustic wave measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves with two type acoustic sensors having 125kHz and 50kHz resonant frequency respectively when the particles were bounced on the inside surfaces of GIS tanks by the electrostatic force. To use two sensors for the diagnosis of GIS, we set up the calibration method for this measurement method. We showed the output characteristics of two sensors according to the sizes and materials of particles in the experiment. As the results, the inception voltages bouncing particles depended on the materials and the extinction voltages bouncing them depended on the sizes and materials. We found out that the relationship between sizes of particles and output voltages of sensors didn't have linearity but the ratios of between peak values of two sensors depended on the materials of GIS enclosures and the sizes of particles.

A Study on the Technology Diagnosing Particles with Two Acoustic Emission Sensors Which have the Different Characteristics of Frequency in GIS (주파수특성이 다른 2개의 초음파 친서에 의한 GIS 이물진단 기술 연구)

  • 김광화;최재구;선종호;김익수;윤진열
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.5
    • /
    • pp.219-219
    • /
    • 2003
  • This paper described about the acoustic wave measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves with two type acoustic sensors having 125kHz and 50kHz resonant frequency respectively when the particles were bounced on the inside surfaces of GIS tanks by the electrostatic force. To use two sensors for the diagnosis of GIS, we set up the calibration method for this measurement method. We showed the output characteristics of two sensors according to the sizes and materials of particles in the experiment. As the results, the inception voltages bouncing particles depended on the materials and the extinction voltages bouncing them depended on the sizes and materials. We found out that the relationship between sizes of particles and output voltages of sensors didn′t have linearity but the ratios of between peak values of two sensors depended on the materials of GIS enclosures and the sizes of particles.

Miniature Ultrasonic and Tactile Sensors for Dexterous Robot

  • Okuyama, Masanori;Yamashita, Kaoru;Noda, Minoru;Sohgawa, Masayuki;Kanashima, Takeshi;Noma, Haruo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.5
    • /
    • pp.215-220
    • /
    • 2012
  • Miniature ultrasonic and tactile sensors on Si substrate have been proposed, fabricated and characterized to detect objects for a dexterous robot. The ultrasonic sensor consists of piezoelectric PZT thin film on a Pt/Ti/$SiO_2$ and/or Si diaphragm fabricated using a micromachining technique; the ultrasonic sensor detects the piezoelectric voltage as an ultrasonic wave. The sensitivity has been enhanced by improving the device structure, and the resonant frequency in the array sensor has been equalized. Position detection has been carried out by using a sensor array with high sensitivity and uniform resonant frequency. The tactile sensor consists of four or three warped cantilevers which have NiCr or $Si:B^+$ piezoresistive layer for stress detection. Normal and shear stresses can be estimated by calculation using resistance changes of the piezoresitive layers on the cantilevers. Gripping state has been identified by using the tactile sensor which is installed on finger of a robot hand, and friction of objects has been measured by slipping the sensor.

Feasibility of RF Sensor Application for On-line Monitoring of Tomato Paste Processing (토마토 패이스트 가공공정의 온라인 모니터링용 RF 센서의 활용 가능성)

  • Kim, Seong-Min;Garvey, Casey;Leary, Thomas;McCarthy, Michael
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.410-415
    • /
    • 2008
  • On-line monitoring of fresh tomato paste processing was done using two radio frequency (RF) sensors resonant at 85 and 110 MHz. Fresh tomato juice with soluble solid content of about $5^{\circ}Brix$ was evaporated up to $23^{\circ}Brix$ and diluted down to about $5^{\circ}Brix$ again with a pilot scale evaporator. The RF sensors were installed in a processing pipe and monitored. The pastes at a specific $^{\circ}Brix$ level were sampled and analyzed for physical properties such as soluble solid content and viscosity. The relationships between sensor outputs and measured physical properties were analyzed. Analysis results showed RF sensor is feasible to apply on-line monitoring of tomato paste processing.

Sensitivity Characteristics of Acoustic Emission(AE) Sensor using the Lead-free (Na1,K)NbO3 Ceramics (무연 (Na1,K)NbO3 계 세라믹스를 이용한 AE센서의 감도특성)

  • Yoo, Ju-Hyun;Lee, Gab-Soo;Hong, Jae-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.3
    • /
    • pp.218-222
    • /
    • 2007
  • In this study, Acoustic emission(AE) sensors were fabricated using lead-free piezoelectric ceramics for prohibiting environmental pollution. Structure of AE sensors were designed as Langvin type air backing form. Here, the piezoelectic element was used as PZT(EC-65)(AE1) and NKN(AE2), respectively. The measured resonant frequency, the maximum sensitivity frequency and sensitivity of AE sensors were as follows ; 143 kHz, 29.4 kHz and 69.3 dB in AE1 and 179 kHz, 29.4 kHz and 66.3dB in AE2, respectively.

System Identification of a Plate with Piezoelectric Actuators and Sensors (압전 가진기와 압전 센서를 부착한 평판의 시스템 식별)

  • 송철기;황진권;이장무
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.11
    • /
    • pp.172-179
    • /
    • 1998
  • This paper proposes an identification method for modes of a thin plate where multiple actuators and sensors are bonded. When a natural frequency of a mode is decoupled from all other natural frequencies, the mode can be identified separatedly with a bandpass filter. Since a thin plate has resonant peaks at natural frequencies, the bandpass filter can be designed to extract the signal of the mode to be identified. Parameters of the second order linear differential equation of the mode can be obtained to apply the Least square method to the extract the modal signal. The proposed identification method is applied to an all-clamped plate with two pairs of piezoelectric actuators and sensors. The outputs of the identified model match with the experimental data well.

  • PDF

Sensitivity Analysis for Specifications of Silicon-on-Insulator (SOI) Slot Optical Waveguide-based Single and Add-drop Channel Ring-resonant Biochemical Integrated Optical Sensors (SOI 슬롯 광 도파로 기반 단일 및 삽입-분기 채널 링-공진형 바이오·케미컬 집적광학 센서의 제원에 대한 감도 해석)

  • Jang, Jaesik;Jung, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.107-114
    • /
    • 2022
  • The effects of ring radius and coupling spacing on the free spectral range (FSR), full width at half maximum (FWHM), quality factor, and sensitivity of single-channel and add-drop channel slot ring resonators were systematically investigated using FIMMPROP and PICWAVE numerical software. The single-channel ring resonator exhibited better characteristics, namely, a wider FSR and narrower FWHM compared with the add-drop structure; thus, it was evaluated to be more suitable for biochemical sensors. The FSR, FWHM, quality factor, and sensitivity for a single channel ring resonator with a radius of 59.4 ㎛ and coupling gap of 0.5 ㎛ were 2.4 nm, 0.087 nm, 17677, and 550 [nm/RIU], respectively.