• 제목/요약/키워드: Resonance frequency analysis value

검색결과 107건 처리시간 0.024초

트랙터 프레임의 동특성 해석 및 시험결과 분석 (Dynamic Analysis of tractor frame analysis and test results)

  • 안태길;박영지;김중호;김상균
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.566-568
    • /
    • 2014
  • The phenomenon that it becomes the damage to the object occurs due to the resonance. I found out the sole vibration frequency at the tractor frame through the finite element analysis and extended the life of the tractor and tested a stability in order to prevent that damage. The results of the experimental and theoretical values were satisfactory, thereby the object of the experiment do not have a theoretical value to find out a problem of vibration was able to grasp.

  • PDF

기존선용 시멘트 모르터 충진형 포장궤도의 개발 (Development of the Cement Mortar Grouting type Paved Track for Existing Line)

  • 이일화;이희업;이준석;이진욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.389-393
    • /
    • 2005
  • When the high-speed train running on the track, there is a speed limit which track distortion is unusually increased according to condition of track and roadbed. This speed limit is called critical velocity, and physical parameter value increased very greatly. These phenomenon happened as high-speed train were developed, studied regularly through TGV 100 running test in France. As research result until now, the main reason is soft roadbed's capacity. Wave propagation and track support capacity is varied by the site characteristics. This paper achieved theoretical examination about resonance band(speed and frequency) that occurred in roadbed on the base rock in point of geotechnical engineering. The examination of resonance divides with ground response analysis, critical band analysis by the shear wave velocity of roadbed, train critical speed through the ground stratum.

  • PDF

Frequency response of film casting process

  • Hyun, Jae-Chun;Lee, Joo-Sung;Jung, Hyun-Wook
    • Korea-Australia Rheology Journal
    • /
    • 제15권2호
    • /
    • pp.91-96
    • /
    • 2003
  • The sensitivity of the product to the ongoing sinusoidal disturbances of the process has been investigated in the film casting of viscoelastic polymer fluids using frequency response analysis. As demonstrated for fiber spinning process (Jung et al., 2002; Devereux and Denn, 1994), this frequency response analysis is useful for examining the process sensitivity and the stability of extensional deformation processes including film casting. The results of the present study reveal that the amplification ratios or gains of the process/product variables such as the cross-sectional area at the take-up to disturbances exhibit resonant peaks along the frequency regime as expected for the systems having hyperbolic characteristics with spilt boundary conditions (Friedly, 1972). The effects on the sensitivity results of two important parameters of film casting, i.e., the fluid viscoelasticity and the aspect ratio of the casting equipment have been scrutinized. It turns out that depending on the extension thinning or thickening nature of the fluid, increasing viscoelasticity results in enlargement or reduction of the sensitivity, respectively. As regards the aspect ratio, it has been found that an optimum value exists making the system least sensitive. The present study also confirms that the frequency response method produces results that corroborate well those by other methods like linear stability Analysis and transient solutions response. (Iyengar and Co, 1996; Silagy et al., 1996; Lee and Hyun, 2001).

임플랜트 표면처리가 생체활성에 미치는 영향 (EFFECT OF DIFFERENT SURFACE TREATMENTS TO INCREASE BIOCOMPATIBILITY OF DENTAL IMPLANT)

  • 이호진;송광엽;윤태호
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.594-605
    • /
    • 2006
  • Statement of problem: Modification of titanium implant surface has potential to ensure clinically favorable performance that several surface modification technologies have been introduced. Among the methods. anodizing method and sol-gel hydroxyapatite coating method have gained much interest due to its roughness and chemical composition of the coating layer, but more of its biocompatibility result is required. Purpose : The purpose of this study was to compare bone-implant interface shear strength of four different surface treated implants as time elapsed. Resonance frequency analysis(RFA) and removal torque measurement methods were employed to measure implant stability at one week and six week after implantation. Material and method: A total of 80 screw-shaped implant [20 machined, 20 resorbable media blasted(RBM), 20 anodized, and 20 anodized+hydroxyapatite sol-gel coated] were prepared, and one of each group was implanted in the tibia of a New Zealand white rabbit that total 20 of them were used. In order to test the implant stability and implant-tissue interface contact changing in the bone bed, each 10 rabbit were sacrificed 1 week and 6 week later while resonance frequency and removal torque were measured. One-way analysis of variance and the Tukey test were used for statistical analysis. Results : The results were as follows. 1. There was no statistically significant difference of implant stability quotients(ISQ) value in RFA between individual groups after 1 week of implantation and 6 weeks(p>0.05). But, there was statistically significant increase of ISQ value in 6 weeks group compared to 1 week group(p<0.05). 2. There was no statistically significant difference in removal torque analysis between individual groups after 1 week of implantation and 6 weeks(p>0.05). but there was statistically significant increase in all 4 groups after 6 weeks compared to 1 week later(p<0.05). 3. There was no statistically significant difference in removal torque analysis between anodized group and HA coating after anodic oxidation 6 weeks later(p>0.05), but significant difference was appeared in both groups compared to RBM group and smooth-machined group(p<0.05). Conclusions : It can be suggested that changes in surface characteristics affect bone reactions. Anodized and anodized+hydroxyapatite sol-gel coating showed significantly improved bone tissue response to implants, but further study on the effect of hydroxyapatite dissolution is needed.

Analysis of vortex induced vibration frequency of super tall building based on wind tunnel tests of MDOF aero-elastic model

  • Wang, Lei;Liang, Shuguo;Song, Jie;Wang, Shuliang
    • Wind and Structures
    • /
    • 제21권5호
    • /
    • pp.523-536
    • /
    • 2015
  • To study the vibration frequency of super high-rise buildings in the process of vortex induced vibration (VIV), wind tunnel tests of multi-degree-of-freedom (MDOF) aero-elastic models were carried out to measure the vibration frequency of the system directly. The effects of structural damping, wind field category, mass density, reduced wind velocity ($V_r$), as well as VIV displacement on the VIV frequency were investigated systematically. It was found that the frequency drift phenomenon cannot be ignored when the building is very high and flexible. When $V_r$ is less than 8, the drift magnitude of the frequency is typically positive. When $V_r$ is close to the critical wind velocity of resonance, the frequency drift magnitude becomes negative and reaches a minimum at the critical wind velocity. When $V_r$ is larger than12, the frequency drift magnitude almost maintains a stable value that is slightly smaller than the fundamental frequency of the aero-elastic model. Furthermore, the vibration frequency does not lock in the vortex shedding frequency completely, and it can even be significantly modified by the vortex shedding frequency when the reduced wind velocity is close to 10.5.

진동 특성을 고려한 자동차 냉각모듈 방진고무의 내구성 평가 (Evaluation for Fatigue Life of Rubber Isolator for Vibration Characteristic on Automotive Cooling Module)

  • 심희진;김한철;김정규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.350-355
    • /
    • 2008
  • A Rubber mount is widely used for mechanical parts or engineering materials. Especially, it plays an important role in reducing mechanical vibration due to cyclic loading. But, rubber mount is damaged due to the cyclic loading and resonance. Therefore, it is necessary to investigate evaluation of fatigue life considering vibration characteristics for rubber. In this study, a vibration fatigue analysis was performed and based on Power Spectral Density(PSD) and the stress-life curve and a result of frequency response analysis in the finite element method. The measured load history in experiment was transformed to PSD curve. The stress-life curve was obtained by nonlinear static analysis and fatigue test. In addition, frequency response analysis was conducted for mechanical part. In order to evaluate fatigue life of rubber mount, vibration fatigue test was conducted at the constant acceleration-level as well. Fatigue life was determined when the load capacity is reduced to 60% of its initial value. As a result, predicted fatigue life of rubber mount agreed fairly well with the experimental fatigue life.

  • PDF

순시 공진 전압 합성형 DC-DC 컨버터의 특성해석 (A Characteristic Analysis of Instantaneous Resonance Voltage Resultant Type DC-DC Converter)

  • 황계호;오경섭;노채균;남승식;민병재;김경식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2033-2035
    • /
    • 1998
  • This paper describes a DC-DC converter connected two unites inverters, a half-bridge type of high frequency resonance inverter, at the input with parallel. The proposed paper certified that theorem waveforms are equal to experiment waveforms, in addition, it estimated characteristics such as characteristic of average power, characteristic of average output voltage, characterisic of output voltage ripple etc., for designing the device with normalized parameter value.

  • PDF

모멘트법에 의한 접힌 안테나의 특성해석 (Analysis of Folded Dipole Antenna by Moment Methods)

  • 이상설
    • 대한전자공학회논문지
    • /
    • 제15권2호
    • /
    • pp.15-18
    • /
    • 1978
  • 입력임피던스를 크게 하기 위하여 널리 사용되는 접힌 안테나의 임피이던스 변환비와 견환비에 따른 입력어드미턴스의 변화모양을 Moment법에 의하여 계산했다. 계산결과는 Guertler의 공식에 의한 것과 비교하여 이론적타당성을 확인한다. 절힌 안테나의 입력콘덕턴스는 공진주파수보다 다소 낮은 고파수에서 최대로 되고 써셉턴스는 주기적 성질을 가져서 안테나 두 소자의 굵기가 매우 다르지 않을 때는 몇 경의 주파수에서 0으로 된다. 또한 안테나 두 소자의 굴기차가 심할 수록 입력어드미턴스의 주파수에 대한 변화가 완만하여 좋은 주파수특성을 갖는다.

  • PDF

연질 골에서 두 종류의 테이퍼 형태 임플란트의 초기 안정성에 관한 실험실적 연구 (In Vitro Study on the Initial Stability of Two Tapered Dental Implant Systems in Poor Bone Quality)

  • 김덕래;김명주;권호범;이석형;임영준
    • 구강회복응용과학지
    • /
    • 제25권4호
    • /
    • pp.391-401
    • /
    • 2009
  • 임플란트의 성공은 식립 후의 초기 안정성 (Initial stability)의 결과가 중요한 영향을 준다. 이 연구의 목적은 연질 골에서 두 종류의 테이퍼 형태 임플란트가 임플란트의 디자인과 self-tapping blade의 유무에 따라서 초기 안정성에 주는 영향을 알아보는 것이다. Self-tapping blade를 가지고 있는 것과 가지고 있지 않은 두 종류의 테이퍼 형태 임플란트가 사용되었다. Solid Rigid Polyurethane Form으로 연질 골 상태인 D4 골 모형을 재현하였다. 임플란트 고정체를 식립하면서 초기 안정성 값을 기록하고, 식립 직후 implant stability quotient (ISQ)을 측정하여 Resonance frequency Analysis (RFA)를 평가하였다. 마지막으로 임플란트가 식립된 모형골을 만능 시험기에 부착하여 장축 방향으로의 pull-out force를 측정하였다. 초기 안정성 값과 최대 pull-out torque 값은 non self-tapping implants가 self-tapping group에 비하여 통계학적으로 유의하게 큰 평균값을 나타냈다 (P = 0.008). 공진 주파수 분석 결과인 ISQ 값은 거의 비슷한 평균값을 보였으면 통계학적으로 차이가 없었다. 각 임플란트 시스템에서 식립 토크와 pull-out 최대 토크 그리고 공진 주파수 간에는 상관관계를 나타내지 않았다. Non self-tapping 임플란트의 높은 식립 토크는 임상적으로 우수한 초기 안정성을 의미한다. 결론적으로 연질 골에서 self-tapping blade가 없는 임플란트가 있는 것 보다 더 우수한 초기 안정성을 보였다.

진동가속도계의 주파수응답특성 개선에 관한 연구 (Study on improvement of frequency response characteristics of accelerometer)

  • 한응교;조진호
    • 오토저널
    • /
    • 제3권1호
    • /
    • pp.61-68
    • /
    • 1981
  • There are three types in frequency response accelerometer; one is lightly damped piezp type, another is oil damping stainguage type and the third is electro induction type accelerometer within electromagnetic damping. The usable frequency range of lightly damped accelerometers is limited to 0.2 of their mounted natural frequency for amplitude distortion of less than 5 percents. There have been situation where the measured motion contains unforeseen high - frequency components, which are regarded as such due to the accelerometer transfer function. There are several way to overcome amplitude distortion of the higher than anticipated frequency components; (I) to make use of the accelerometer with natural frequency three times and more as high as the measured frequency, (II) to establish data-analysis techniques which will account for the amplitude distortion, (III) to set up a notch filter circuit which has a transfer function that is the reciprocal of the accelerometer transfer function, and so on. This paper makes a report of the method as to(III), i. e., set up a few notch filter circuits, it is discussed what happens when the transfer functions, are in discord as to natural frequency of the filter and accelerometer damping vs. filter damping. And especially as for the cantilever strain gauge type accelerometer made by oneself with ease, it was compared and discussed between the ideological value and the experimental value of actual designed circuit in case of the mismatching of the transfer functions, and it was considered whether to be practicable or not, the result of which was as following; the useful frequency range of the accelerometer can be extended to near resonance if (a) the accelerometer mounted natural frequency and the filter center frequency are matched within .+-. 2 percent and (b) the damping ratios are matched within two factors. Therefore, we obtained the good result in improvement for extending frequency response characteristics of accelerometer.

  • PDF