References
- Long M. Rack HJ. Titanium alloys in total joint replacement: A materials science perspective. Biomaterials 1998;19:1621-1639 https://doi.org/10.1016/S0142-9612(97)00146-4
- Gu H. Xu G. Biomedical material science. Tianjin: Science Translation Press; 1993
- Wilke A. Landgraff M, Orth J, Kienpfel H, Grissand P, Franke R. Human bone marrow cell cultures: A sensitive method for determination of the biocompatibility of implant materials. ATLA 1999;27:137-151
- Brunette DM, Tengvall P, Textor M, Thomsen P. Titanium in medicine. Berlin:Springer;2001
- Quirynen M. Bollen CM, Papaioannou W, Van Eldere J, van Steenberghe D. The influence of titanium abutment surface roughness on plaque accumulation and gingivitis: Short-tern observations. Int J Oral Maxillofac Implants 1996;11:169-178
- Hutton JE, Health MR, Chai JY, Harnett J, Jemt T. Johns RB. Factors related to success and failure rates at 4-year followup in a multicenter study of overdentures supported by Branemark implants. Int J Oral Maxillofac Implants 1995;10:334
- Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mat Res 1991;25:889-902 https://doi.org/10.1002/jbm.820250708
- Gottlaner M, Albrektsson T. Histomorphometric studies of hydroxylapatitecoated and uncoated CP titanium threaded implants in bone. Int J Oral and Maxillofac Implants 1991;6:399-404
- Wennerberg A, Albrektsson T, Andersson B. Design and surface characteristics of 13 commercially available oral implant systems. Int J Oral and Maxillofac Impl 1993;8:622633
- Rompen E, DaSilva D, Lundgren AK. Stability measurements of a doublethreaded titanium implant design with turned or oxidized surface. Applied Osseointegration Research 2001;2:1820
- Glauser R, Portmann M, Ruhstaller P. Initial implant stability using different implant designs and surgical techniques. Applied Osseointegration Research 2001; 2:6-8
- Cooper LF. A role for surface topography in creating and maintaining bone at titanium endosseous implants. J Prosthet Dent 2000;84:522-534 https://doi.org/10.1067/mpr.2000.111966
- Wennerberg A, Albrektsson T, Andersson B, Eng M, Design and surface characteristics of 13 commercially available oral implant systems, Int J Oral Maxillofac Implants 1993;11:38-45
- Kim YH, Heo SJ. A histomorphometric analysis for the effect of various surface treatment methods on the osseointegration. J Korean Acad Prosthodont 2004;42:318-329
- Piattelli M, Scarano A, Paolantonio M, Iezzi G, Petrone G, Piattelli A. Bone response to machined and resorbable blast material titanium implants: An experimental study in rabbits. J Oral Implantol 2002;28:2-8 https://doi.org/10.1563/1548-1336(2002)028<0002:BRTMAR>2.3.CO;2
- Sanz A, Oyarzun A, Farias D, Diaz I. Experimental study of bone response to a new surface treatment of endosseous titanium implants. Implant Dent 2001; 10:126-131 https://doi.org/10.1097/00008505-200104000-00009
- Deporter DA, Watson PA, Pilliar RM. A histological assessment of the initial healing response adjacent to porous surfaced Ti alloy dental implants in dogs. J Dent Res 1986;65:1064-1070 https://doi.org/10.1177/00220345860650080501
- Pilliar RM, Deporter PA, Watson PA. The effect of partial coating with hydroxyapaite on bone remodeling in relation to porous-coated titanium-alloy dental implants in the dog. J Dent Res 1991;70:1338-1345 https://doi.org/10.1177/00220345910700100501
- Branemark PI. Introduction to osseointegration. Tissue-integrated prostheses. Osseointegration in clinical dentistry. Chicago, Quintessence Publishing Co 1986:11-76
- Adell R, Eriksson B, Lekholm U, Branemark PI, Jemt T. A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral and Maxillofac Implants 1990;5:347-359
- Van Steenberge D, Lekholm U, Bolender C, Folmer T, Henry P, Herrmann I. The applicability of osseointegrated oral implants in the rehabilitation of partial edentulism. A prospective multicenter study of 558 fixtures. Int J Oral and Maxillofac Implants 1990;5:271-281
- Meredith N. On the clinical measurement of implant stability and osseointegration. Thesis. Department of Biomaterials/Handicap Research, Institude for Surgical Sciences, Gothenburg University. Gothenberg, Sweden. 1997
- Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Impl Res 1996:7:261 https://doi.org/10.1034/j.1600-0501.1996.070308.x
- Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. Clin Oral Implant Research 1997:8:226 https://doi.org/10.1034/j.1600-0501.1997.080309.x
- Meredith N, Rasmussen L, Sennerby L, Alleyne D. Mapping implant stability by resonance frequency analysis. Med Sci Research 1996:24:191
- Johansson C, Albrektsson T. Integration of screw implant in the rabbit. A one year follow up of removal torque of titanium implants. Int J Oral Maxillofac Implants 1987:2:69-75
- Ivanoff CJ, Sennerby L, Lekholm U. Influence of mono and bicortical anchorage on the integration of titanium implants. A study in the rabbit tibia. Int J Oral Maxillofac Surg 1996:25:229-235 https://doi.org/10.1016/S0901-5027(96)80036-1
- Kwak MB, Lee CH. The evaluation of the removal torque and the histomorphometry of the Ca-P coating surface in rabbit tibia. J Korean Acad Prosthodont 2004:42:556-571
- Albrektsson T, Jacobsson M. Bone-metal interface in osseointegration. J Prosthet Dent 1987:57:597-607 https://doi.org/10.1016/0022-3913(87)90344-1
- Carlsson L, Rostlund T, Albrektsson B, Albrektsson T. Implant fixation improved by close fit. Cylindrical implant-bone interface studied in rabbits. Acta Orthop Scand 1988:59:272-275 https://doi.org/10.3109/17453678809149361
- Larsson C, Thomsoen P, Aronsson BO. Bone response to surface modified titanium implants. Studies on the tissue response after one year to machined and electropolished implants with different thickness. J Mat Sci Materials in medicine 1997:8:721-729 https://doi.org/10.1023/A:1018548225899
- Sul YT. On the bone response to oxidized titanium implants: The role of microporous structure and chemical composition of the sulfide oxide in enhanced osseointegration(thesis). Goteborg, Sweden: Goteborg Univ, 2002
- Cheang P, Khor KA. Addressing processing problems associated with plasma spraying of hydroxyapatite coatings. Biomaterials 1996:17:537-544 https://doi.org/10.1016/0142-9612(96)82729-3
- Wheeler SL. Eight-year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite coated cylinder implants. Int J Oral Maxilofac Implants 1996:11 :340-350
- Ishizawa H, Fujino M, Ogino M. Mechanical and histological investigation of hydrothermally treated and untreated anodic titanium oxide films containing Ca and P. J Biomedical Materials Research, 1995:29:1459-1468 https://doi.org/10.1002/jbm.820291118
- Li LH, Kim HW, Lee SH, Kong YM, Kim HE. Biocompatibility of titanium implants modified by micro arc oxidation and hydroxyapatite coating. J Biomed Mater Res 2005:73A:48-54 https://doi.org/10.1002/jbm.a.30244
- Kim SJ, Shin SW, Jung SM, Ryu JJ. A study on the stability of 5 different surface treatment methods to dental implant using resonance frequency and histomorphometric analysis. J Korean Acad Prosthodont 2005:43:78-92
- Shulte W. The Periotest periodontal status. Zahnarztl Mitt 1986:76:1
- Shulte W. A new field of application of the Periotest method. The occlusal-periodontal load can now be measured quantitatively. Zahnarztl Mitt 1988:78:474
- Derhami K, Wolfaardt JF, Dent M, Faulkner G, Grace M. Assessment if the periotest device in base line mobility measurements of craniofacial implants. Int J Oral Maxillofac Implants 1995:10:221
- Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res 1997:8:234-243
- Choi JW, Heo SJ, Chang IT, Koak JY, Han JH, Kim YS, Lee SH, Yim SH. Resonance frequency analysis of implants with anodized surface oxides. J Kor Acad Prosthodont 2004:42:305-311