• Title/Summary/Keyword: Resonance condition

Search Result 628, Processing Time 0.027 seconds

Spontaneous Thoracic Epidural Hematoma - Case Report - (흉추부에 발생한 자발성 척수 경막외 혈종 - 증 례 보 고 -)

  • Koo, Tae Heon;Mok, Jin Ho;Lee, Young Bae;Park, Yong Seok;Lee, Kye Chun;Kim, Han Sik
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.131-135
    • /
    • 2000
  • Spontaneous spinal epidural hematoma, an idiopathic accumulation of blood in the vertebral epidural space without identifiable predisposing factors, is a rare condition. The diagnosis can be made from a careful history and neurological examination, but clinical diagnosis is often difficult because of its non-specific symptomatology and it can be confused with myocardial infarct, musculoskeletal pain, vasculitis and acute dissection of an aortic aneurysm. For a favourable outcome, early decompressive laminectomy and evacuation of hematoma are necessary. We report a 50-year-old female who presented with acute paraparesis and back pain on thoracic area. Diagnosis of spinal epidural hematoma which extended over $T_4-T_9$ was made by magnetic resonance imaging. We performed immediately decompressive laminectomy and evacuated the epidural hematoma. No cause for bleeding was evident. Postoperatively, neurological symptoms disappeared within six weeks.

  • PDF

Vibration measures for local structures through modal tests (모달시험을 통한 국부 구조물 방진대책 수립)

  • Kwon, Jong Hyun;Kim, Mun Su;Yang, Sung Boong;Lee, Won Seok;Lee, Bong Min
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2017.10a
    • /
    • pp.14-18
    • /
    • 2017
  • The Lashing bridge and radar mast of ship are upright structures so they are generally exposed to excessive vibration. Recently, the use of low speed main engines for improving fuel efficiency has been increasing, and the excitation frequencies of the main engine are moving to the low frequency band. If the excitation frequencies are coincident with the natural frequencies of the local structure, excessive vibration occurs during main engine operating condition. The modal test is to experimentally determine resonance frequency, mode shape, and damping, which are vibration characteristics of a mechanical structure under dynamic external force. Through this study, the vibration characteristics of the structure are obtained by modal tests and the low vibration measure is applied to the local structures.

  • PDF

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

Fabrication and Operation Testing of an Air-cored Pulse Transformer for Charging a High Voltage Pulse Forming Line (고압 펄스 성형라인 충전을 위한 공심형 고압 펄스트랜스의 제작과 동작 특성)

  • Jin, Yun-Sik;Kim, Young-Bae;Kim, Jong-Soo;Ryoo, Hong-Je;Cho, Chu-Hyun;Rim, Geun-Hee;Lim, Soo-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.939-944
    • /
    • 2010
  • A high voltage air-cored helical strip/wire type pulse transformer has been fabricated for charging of a high voltage pulse forming line. As a primary coil, copper strip of 25mm width was wound helically around a MC nylon cylinder. For a secondary coil, copper enameled wire of 1mm diameter was wound around conical cylinder in order to provide insulation between two windings. The coupling coefficient of 0.53 was obtained when two coils were combined coaxially in the insulation oil filled chamber. Voltage gain and energy transfer efficiency were investigated by varying the parameters of primary and secondary circuit. Test results shows that the voltage gain increases up to 17 with increasing the primary capacitance up to 200nF. And highest energy transfer efficiency of 44% was obtained when the dual resonant operation condition was nearly satisfied. The pulse transformer developed in this study can be used for charging the middle conductor of a Blumlein pulse forming line.

Two adolescent patients with coexistent Graves' disease and Moyamoya disease in Korea

  • Cheon, Chong Kun;Kim, Su Yung;Yoo, Jae-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.6
    • /
    • pp.287-291
    • /
    • 2014
  • Moyamoya disease is a cerebrovascular condition that results in the narrowing of the vessels of the circle of Willis and collateral vessel formation at the base of the brain. Although relationships between Graves' disease and cerebrovascular accidents in Moyamoya disease are obscure, the coexistence of the two diseases is noteworthy. Moyamoya disease has been rarely reported in adolescent patients with thyrotoxicosis. Recently, we encountered two adolescent Korean patients with Moyamoya disease associated with Graves' disease who presented with episodic right-sided hemiparesis and syncope. These two girls who had Graves' disease had no history of other diseases or head trauma. A thyroid function test revealed a euthyroid state and a high thyroid-stimulating hormone (TSH) receptor antibody titer at that time. The patients were diagnosed with Moyamoya disease based on brain magnetic resonance angiography and cerebral four-vessel angiography. The patients underwent cranial revascularization by encephalo-duroarterio-synangiosis as soon as a diagnosis was made, which resulted in successful symptom resolution. They fared well and had no additional neurological symptoms as of their last follow-up visits. Here, we report these two cases of confirmed Moyamoya disease complicated by Graves' disease with a review of the literature, and discuss the possible association between the two diseases. To our knowledge, this is the first report in South Korea on Moyamoya disease associated with Graves' disease in adolescents with a euthyroid.

The Basic Study on the Leak Test Method of the Hydrogen Exhaust Pipe for a Fuel Cell Vehicle (연료전지차용 수소배출 배관 및 배관이음매 안전성 평가를 위한 기초 연구)

  • Suh, Ho-Cheol;Park, Kyoung-Suk;Seo, Kyung-Doo;Yong, Gee-Joong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.2
    • /
    • pp.185-192
    • /
    • 2011
  • This study deals with a basic proposal to prove the safety for the exhausted fittings of the hydrogen fuel cell vehicle. First, this study was approached to numerical analysis solving to close the exact boundary condition (Axial, Bending, Lateral) and the second, this study produced the Lateral movement equipment for the vibration. For the numerical analysis, This study was considered with the exact solution of Lateral movement and the resonance effect for durability sample according to fitting positions. The second, This study was made for special equipment for displacement/gas leak and the frequency because the domestic samples were comparing with foreign fitting and foreign fitting for the hydrogen fuel cell vehicle. The result of this study was satisfied with domestic fittings for the basic reference but it need more test because of other situation for hydrogen fuel cell vehicle.

Development of the Bus Duct Installation System for Wind Tower (풍력타워용 부스덕트 포설시스템 개발)

  • Rhee, Huinam;Lee, Joon Keun;Kim, Bong-Seok;Park, Seong-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.219-226
    • /
    • 2014
  • A bus duct system for wind tower is introduced. A marine cable has been widely used in wind tower or various offshore structures. However, as the electric load capacity is increases, large number of cable lines must be used to cover the huge amount of electric capacities. Therefore, the installation of the cable lines becomes very difficult due to the heavy weight and volume of the cables. On the other hand, by using a single bus duct system line, the power capacity amount of 16 cables can be delivered with significantly compacted form. However, unlike flexible cables, the bus duct is relatively stiff which could generate the resonance phenomenon in the operating condition of the wind tower. In this study, the vibration characteristics of the bus duct are investigated and its long-term reliability during the life time of the wind tower is verified.

Start-up Noise Reduction of Reciprocating Compressor Using Cavity Resonance Analysis (공동 공진해석을 이용한 왕복동식 압축기의 기동소음 저감에 관한 연구)

  • Kim, Min-Chul;Kim, Won-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.2
    • /
    • pp.153-159
    • /
    • 2010
  • This work focuses on finding a method to reduce the noise of a hermetic reciprocating compressor during start-up using an acoustical analysis. The noise of compressor during start-up, which is a higher level than that of a normal operating condition, has transient and non-stationary characteristics. The acoustical analysis of compressor cavity is performed to find an effective method to reduce the noise level. In the acoustical analysis, the shape variations of frequency response function in the neighborhood of resonances are tested for three parameters: the height of remained oil, the suction position of refrigerant and the position of driving part. As a conclusion of this result, to reduce the emission noise of compressor during start-up, the height of remained oil should be kept at 16 mm, the refrigerant should be sucked at the cross point of nodal lines of X and Y directional cavity modes, and the driving part should be positioned in the center of cavity.

Vibration Performance Monitoring of a 1kW Small Wind Turbine Generator (1kW 소형 풍력발전기의 진동 성능 모니터링)

  • Kim, Seok-Hyun;Nam, Yoon-Soo;Yoo, Neung-Soo;Park, Mu-Yeol;Kim, Tae-Hyoung;Park, Hae-Gyun
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.75-80
    • /
    • 2006
  • A vibration monitoring is performed on a 1kW class stand alone wind turbine(W/T). When a W/T model is developed, general performance under various wind condition should be verified to introduce the product in the market. Especially, vibration characteristics within operating speed range are very important in the aspect of structural stability as well as generator's electrical efficiency. This paper examines the vibration performance of a home made 1kW W/T. Various data of the W/T model are acquired in real time using a remote vibration monitoring system installed in Daekwanryung test site. Vibration stability of the W/T structure is diagnosed based upon the data and the result is used to estimate the applicability of the W/T model.

  • PDF

A study on the calculation of Synthesized torsional vibration for the marine diesel engine shafting by the modal analysis method (모오드 해석법에 의한 박용디젤기관 추진축계의 합성 비틀림 진동계산에 관한 연구)

  • 이강복;전효중;남청도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.159-169
    • /
    • 1985
  • The calculation of torsional vibration for marine diesel engine propulsion shafting is normally carried out by equalizing exciting energy to damping energy, or using the dynamic magnifier. But, with these methods, the vibration amplitudes are calculated only for resonance points and vibration amplitudes of other running speeds of engine are determined by the estimation. Recently, many energy-saving ships have been built and on these ships, two-stroke, supercharged, super-long stroke diesel engines which have a small number of cylinders are usually installed. In these cases, the first order critical-torsional vibrations of these engine shaftings appear ordinarily near the MCR speed and the stress amplitudes of their vibration skirts exceed the limit stress defined by the rules of classification society. To predict the above condition in the design stage, the synthesized vibration amplitudes of all orders which are summed up according to their phase angles must be calculated from the drawings of propulsion shaft systems. In this study, a theoretical method to fulfill the above calculation is derived and a computer program is developed according to the derived method. And a shafting system of two-stroke, super-long stroke diesel engine which was installed in a bulk carrier is analyzed with this method. The measured values of this engine shafting are compared with those of calculated results and they show a fairly good agreement.

  • PDF