Vibration Performance Monitoring of a 1kW Small Wind Turbine Generator

1kW 소형 풍력발전기의 진동 성능 모니터링

  • 김석현 (강원대학교 기계메카트로닉스공학부) ;
  • 남윤수 (강원대학교 기계메카트로닉스공학부) ;
  • 유능수 (강원대학교 기계메카트로닉스공학부) ;
  • 박무열 (강원대학교 기계메카트로닉스공학과) ;
  • 김태형 (강원대학교 기계메카트로닉스공학과) ;
  • 박해균 (강원대학교 기계메카트로닉스공학과)
  • Published : 2006.02.28

Abstract

A vibration monitoring is performed on a 1kW class stand alone wind turbine(W/T). When a W/T model is developed, general performance under various wind condition should be verified to introduce the product in the market. Especially, vibration characteristics within operating speed range are very important in the aspect of structural stability as well as generator's electrical efficiency. This paper examines the vibration performance of a home made 1kW W/T. Various data of the W/T model are acquired in real time using a remote vibration monitoring system installed in Daekwanryung test site. Vibration stability of the W/T structure is diagnosed based upon the data and the result is used to estimate the applicability of the W/T model.

Keywords