• Title/Summary/Keyword: Resonance condition

Search Result 625, Processing Time 0.028 seconds

Metabolic Profiling of Urine Samples from Colorectal Cancer Patients Before and After Surgical Treatments

  • Chae, Young-Kee;Kang, Woo-Young;Kim, Seong-Hwan;Joo, Jong-Eun;Han, Joon-Kil;Hong, Boo-Whan
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.14 no.1
    • /
    • pp.28-37
    • /
    • 2010
  • Metabolites of urine samples from 6 colorectal cancer patients were analyzed by two-dimensional NMR spectroscopy, where the samples were collected before and after the surgical treatments per patient. NMR data were analyzed with the help of the metabolome database and the statistics software. Urine samples before and after the treatments showed significantly different metabolic profiles from each other. We were able to compare 10 different metabolites. Most of the assigned metabolites of every patient showed a tendency of increase after the surgery except for a few cases. The amount of changes in individual metabolites varied significantly from patient to patient, but the combination of such changes could be used to distinguish the condition before the surgery from after, which could be done by PCA analysis. The analysis via $^{1}H-^{13}C$ HSQC spectra proved to be applicable in assessing and classifying global metabolic profiles of the urines from colorectal cancer patients.

A study on the design of a K-band harmonic oscillator using voltage controlled dielectric resonance (전압제어 유전체공진을 이용한 K-대역 발진기 설계에 관한 연구)

  • 전순익;김성철;은도현;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3215-3226
    • /
    • 1996
  • In this paper a K-band harmonic oscillator competitive to ordinary Push-Push type oscillators is introduced. This oscillator is composed of two-X-band dielectric resonance circuits. To favor its harmonic generation, the load effect and the bias effect are studied to allow the maximum harmonic distortion. As results, the dielectric resonated load and the class A bias are used for the 2nd harmonic generation. analytical study for modelling of voltage controlled dielectric resonator is carried out with theoretical background. The performance of the circuit is evaluated by simulation using harmonic balanced method. The novel structure has ont only a voltage tuning circuit but also an output port at fundamental frequency as the function of prescaler for phase lockede loop application on the just single oscillation structure. In experimentation, the output freqneyc of the 2nd harmonic signal is 20.5GHz and the maximum power level of output is +5.5dBm without additional post amplifiers. the harmonic oscillator exhibits -30dBc of high fundamental frequency rejection without added extra filters. The phase noise of -90dBc/Hz at 100kHz off-carrier has been achieved under free running condition, that satisfies phase noise requirement of IESS 308. The proposed oscillator may be utilized as the clean and stable fixed local oscillator in Transmit Block Upconvertor(TBU) or Low oise Block downconvertor(LNB) for K/Ka-band digital communications and satellite broadcastings.

  • PDF

A Case Study of Harmonic Resonance & Black Start in Weak Feed Power System (Weak Feed 전력계통의 블랙스타트와 고조파 공진 사례연구)

  • Park, Young-Chul;Lee, Eun-Seob;Son, Hyo-Soo;Lee, Seok-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.40-50
    • /
    • 2016
  • In order to recover the power system during the wide power outage or power failure in the power plant, black start system should be properly operated without any problem. Especially power for black start in the geographically isolated areas of electric island is supplied from small emergency start-up generator, and loads are aux systems of gas turbines such as SFC(Static frequency converter). This paper introduces the international practices to overcome the voltage drop problem with harmonics of the system having the DC output such as SFC during black start in weak feed system and analyzes the relationship between house load inputs and harmonics. By varying the house load and input of power supply, this paper identified boundaries between weak feed and strong feed power. In order to verify the theory of stable condition in weak feed power system with DC output, house load is simulated using ETAP. Additionally MATLAB was used for harmonic analysis between the load inertia moment and non load inertia moment.

Analysis of Natural Frequency of Simple Steel Outfitting Structure in Engine Room (기관실 단순 철의장품 모델 고유 진동수 해석)

  • Jung, C.S.;Kim, D.S.;Cho, S.A.;Chang, S.I.
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2006.09a
    • /
    • pp.106-111
    • /
    • 2006
  • The steel outfitting structures installed in engine room are vibrated by an excitation of the engine and the propeller. Vibration problems such as cracks and fitting breakages are mainly induced at the near range of the resonance. The excitation frequency estimation is possible by engines and propeller specifications, but the natural frequency of a steel outfitting structure is not easily estimated due to the complication and variety of the designed shape. This paper represents natural frequency data of simple steel outfitting structures. As a vibration analysis tool, MSC/NASTRAN was used to calculate natural frequencies. Natural frequencies were compared in case of the shape and boundary condition changes of simple models, and anti-vibration models of the steel outfitting structures were presented on the basis of results.

  • PDF

Comparison of the Net Inflow Rates of Seawater Exchange Breakwater of Different Shapes (해수교환방파제의 형상별 순유입유량 특성 비교)

  • Lee, Dal-Soo;Lee, Chang-Hoon;Oh, Young-Min;Chun, In-Sik;Kim, Chang-Il
    • Ocean and Polar Research
    • /
    • v.25 no.spc3
    • /
    • pp.393-397
    • /
    • 2003
  • The seawater exchange breakwaters can be effectively employed to conserve or enhance the water quality inside harbors by transmitting the exterior water into the harbor. In the present study, three shapes of the breakwater, that is, the flow conduit embedded type, the wave chamber type and the oscillating water channel type are compared far their water exchanging capability through regular wave experiments. The results show that the net influx of water appears differently depending on wave period for each breakwater type. The net influx of the wave chamber type is much greater than that of the flow conduit embedded type. It is also ascertained that the influx of the oscillating water channel type can be greatly enhanced by attaining the resonance condition inside the channel at the wave periods frequently occurring at the fields where the breakwaters are to be installed.

Medulloblastoma Manifesting as Sudden Sensorineural Hearing Loss

  • Terakawa, Yuzo;Tsuyuguchi, Naohiro;Takami, Toshihiro;Ohata, Kenji
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.1
    • /
    • pp.51-53
    • /
    • 2011
  • We present a rare case of medulloblastoma which presented with unilateral sudden sensorineural hearing loss as an initial symptom. A 19-year-old man was admitted to our hospital with a chief complaint of dizziness and facial numbness on the right side. His illness had begun two years previously with sudden hearing loss on the right side, for which he had been treated as an idiopathic sudden hearing loss. Magnetic resonance imaging demonstrated abnormal signals located mainly in the right middle cerebellar peduncle. We performed partial resection of the tumor by suboccipital craniotomy. The histopathological diagnosis was medulloblastoma. Intrinsic brain tumor is an extremely rare cause of sudden sensorineural hearing loss and is therefore easily overlooked as was in the present case. The present case highlights not only the need to evaluate patients with sudden sensorineural hearing loss by magnetic resonance imaging but also the importance of paying attention to intrinsic lesions involving the brainstem. Although this condition like the presented case might be rare, intrinsic brain tumor should be considered as a potential cause of sudden sensorineural hearing loss, as it may be easily missed leading to a delay in appropriate treatment.

Miniaturized Microstrip Dual Band-Stop Filter Using Stepped Impedance Resonators (계단형 임피던스 공진기를 이용한 소형화된 마이크로스트립 이중 대역 저지 필터)

  • Kim, Gi-Rae;Park, Young-Bae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.8
    • /
    • pp.1653-1658
    • /
    • 2011
  • A novel circuit structure of dual-band bandstop filters is proposed in this paper. This structure comprises two shunt-connected tri-section stepped impedance resonators with a transmission line in between. Theoretical analysis from the equivalent circuit and design procedures are described. We represented graphs for filter design from the derived synthesis equations by resonance condition of circuits. Notably, advantages of the proposed filter structure are compact size in design, wide range of realizable resonance frequency ratio, and more realizable impedances.

Effect of Mn Dopping on the Microwave Dielectric Properties of 0.17($Ba_{0.53}$, $Pb_{0.47}$)0-$0.16Nd_2O_3$-$0.67TiO_2$ Ceramics (0.17($Ba_{0.53}$, $Pb_{0.47}$)0-$0.16Nd_2O_3$-$0.67TiO_2$ 세라믹스의 고주파 유전특성에 미치는 Mn 첨가의 영향)

  • 윤중락;이헌용;김경용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.292-294
    • /
    • 1996
  • Dielectric properties were investigated at Mn doped 0.17($Ba_{0.53}$, $Pb_{0.47}$)0-$0.16Nd_2O_3$-$0.67TiO_2$ system in microwave frequency. It was observed that dielectric constant of 90.1, quality factor of 1320 (at 3.8GHz) and temperature coefficient of resonance frequency 2.3 ppm/$^{\circ}C$ for 0.5wt% Mn doped 0.17($Ba_{0.53}$, $Pb_{0.47}$)0-$0.16Nd_2O_3$-$0.67TiO_2$ system in sintering condition $1290^{\circ}C$/2hr. The quality factor increase due to the compensation effect of Mn ions yp to 0.5wt% and the decrease due to the interface relaxation effect. The temperature coefficient of resonance frequency increases to negative direction with increasing the amounts of Mn.

  • PDF

A Study of High Precision Constant Velocity Control for Spiral Servo Writing in Hard Disk Drive (하드디스크 드라이브의 Spiral Servo Writing을 위한 초정밀 등속 제어 기법 연구)

  • Cho, K.N;Kang, H.J;Lee, C.W;Chung, C.J;Sim, J.S
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.99-107
    • /
    • 2005
  • According to recent trend, hard disk drive(HDD) has been smaller and less weight. Therefore, it needs new method of writing position information. In this thesis, a new controller that is suitable for SSW is proposed. The controller accepted SSW technology that is used to write position information in current HDD industry. The important condition to perform SSW is to reach constant velocity decided from the head velocity profile as fast as possible. The constant velocity decides the positional accuracy of spiral pattern and setup time decides the capacity of HDD. The head velocity profile as a reference signal must be designed not to cause resonance mode. The proposed controller was designed with consideration of these 3 elements, and it properly works for SSW. The velocity profile designed with SMART control not only minimizes the jerk, but also does not cause the resonance mode of a plant. After designing a conventional PID controller, it compared with electrical spring technique and ZPET technique.

  • PDF

Optimization of Operation Frequency of Orthogonal Fluxgate Sensor Fabricated with Co Based Amorphous Wire

  • Kim, Young-Hak;Kim, Yongmin;Yang, Chang-Seob;Shin, Kwang-Ho
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.159-162
    • /
    • 2013
  • We present how to optimize the operation condition including frequency of the orthogonal fluxgate sensor in this paper. The orthogonal fluxgate sensor was fabricated with a Co-based amorphous wire with 10 mm long and 100 ${\mu}m$ in the diameter and a 270-turn pickup coil wound on the amorphous wire. In order to investigate the frequency dependence of the sensitivity, output spectra of the sensor which was connected by using a coaxial cable with various lengths of 0.5-5 m were measured with a RF lock-in amplifier. The maximum sensitivities were obtained at different frequencies according to coaxial cable lengths. It was found that the optimal operation frequencies, at which maximum sensitivities were appeared, were almost identical to the frequencies of impedance resonance. The maximum sensitivity and optimal operation frequency were 1.1 V/Oe (${\approx}$ 11000 V/T) and 1.25 MHz respectively.