• Title/Summary/Keyword: Resonance Type

Search Result 1,085, Processing Time 0.022 seconds

Tunneling Magnetoresistance of a Ramp-edge Type Junction With Si3N4 Barrier (Si3N4장벽층을 이용한 경사형 모서리 접합의 터널링 자기저항 특성)

  • Kim, Young-Ii;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.6
    • /
    • pp.201-205
    • /
    • 2002
  • The tunneling magnetoresistance (TMR) of a ramp-edge type junction has been studied. The samples with a structure of NiO(60)/Co(10)/NiO(60)/Si$_3$N$_4$(2-6)/NiFe(10) (nm) were prepared by the sputtering and etched by the electron cyclotron (ECR) argon ion milling. Nonlinear I-V characteristics was obtained from a ramp-type tunneling junctions having the dominant difference between zero and +90 Oe perpendicular to the junction edge line. The voltage dependence of TMR was stable up to a bias volt of $\pm$10 V with a TMR ratio of about -10%, which may be very peculiar magnetic tunneling properties with asymmetric tunneling process between wedge Co pinned layer and NiFe free layer.

A Study on the Frequency Characteristics of Tubular and Jacket Type Tower for Offshore Wind Turbine Tower (해상 풍력 발전용 Tubular와 Jacket Type Tower의 진동 특성에 관한 연구)

  • Lee, Kang-Su;Lee, Jung-Tak;Son, Choong-Yul;Kim, Keon-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.615-621
    • /
    • 2007
  • Wind power generation is one of the promising gateways that will solve the energy crisis in the future. The wind power generator studied so far is limited to static interpretation in the areas related to tower. This study broadly sets the form of tower as tubular and jacket, identifies the characteristics of each and aims to find and apply their trend to in actual design and manufacturing process. This paper identified the resonance frequency of tower at each mode and studied their features. Furthermore, this study identified the characteristics of the load that occurs in operation and the effect of additional mass incurring when installed in sea, and it compared the two types of tower and was able to predict their trend.

Resonant Transmission of a Rectangular Waveguide Probe with H-type Small Aperture (H-형태 소형 개구를 가진 직사각형 도파관 탐침의 공진 투과)

  • Ko, Ji-Hwan;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.12
    • /
    • pp.1198-1204
    • /
    • 2013
  • As a microwave near field probe for near field scanning optical microscope(NSOM) system, H-shaped(ridge type) small aperture is proposed and its performances from the viewpoints of the transmission efficiency(transmission cross section) and spatial confinement(beam spot size) are compared with those of the previous narrow rectangular aperture type. While the transmission efficiencies are comparable to each other for the two structures, the transmitted beam spot size for the proposed H-shaped aperture is much smaller than that for the previous rectangular aperture. This strong point of the H-shaped aperture is expected to significantly improve near-field optical applications such as optical data storage, nanolithography and nanomicroscopy. It is also observed that the transmission efficiency can be improved if the coupling aperture is implemented in the type of the transmission cavity.

Study on improvement of frequency response characteristics of accelerometer (진동가속도계의 주파수응답특성 개선에 관한 연구)

  • 한응교;조진호
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.3 no.1
    • /
    • pp.61-68
    • /
    • 1981
  • There are three types in frequency response accelerometer; one is lightly damped piezp type, another is oil damping stainguage type and the third is electro induction type accelerometer within electromagnetic damping. The usable frequency range of lightly damped accelerometers is limited to 0.2 of their mounted natural frequency for amplitude distortion of less than 5 percents. There have been situation where the measured motion contains unforeseen high - frequency components, which are regarded as such due to the accelerometer transfer function. There are several way to overcome amplitude distortion of the higher than anticipated frequency components; (I) to make use of the accelerometer with natural frequency three times and more as high as the measured frequency, (II) to establish data-analysis techniques which will account for the amplitude distortion, (III) to set up a notch filter circuit which has a transfer function that is the reciprocal of the accelerometer transfer function, and so on. This paper makes a report of the method as to(III), i. e., set up a few notch filter circuits, it is discussed what happens when the transfer functions, are in discord as to natural frequency of the filter and accelerometer damping vs. filter damping. And especially as for the cantilever strain gauge type accelerometer made by oneself with ease, it was compared and discussed between the ideological value and the experimental value of actual designed circuit in case of the mismatching of the transfer functions, and it was considered whether to be practicable or not, the result of which was as following; the useful frequency range of the accelerometer can be extended to near resonance if (a) the accelerometer mounted natural frequency and the filter center frequency are matched within .+-. 2 percent and (b) the damping ratios are matched within two factors. Therefore, we obtained the good result in improvement for extending frequency response characteristics of accelerometer.

  • PDF

The Comparative Morphometric Study of the Posterior Cranial Fossa : What Is Effective Approaches to the Treatment of Chiari Malformation Type 1?

  • Hwang, Hyung Sik;Moon, Jae Gon;Kim, Chang Hyun;Oh, Sae-Moon;Song, Joon-Ho;Jeong, Je Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.405-410
    • /
    • 2013
  • Objective : The objective of this study was to investigate changes in the posterior cranial fossa in patients with symptomatic Chiari malformation type I (CMI) compared to a control group. Methods : We retrospectively reviewed clinical and radiological data from 12 symptomatic patients with CMI and 24 healthy control subjects. The structures of the brain and skull base were investigated using magnetic resonance imaging. Results : The length of the clivus had significantly decreased in the CMI group than in the control group (p=0.000). The angle between the clivus and the McRae line (p<0.024), as the angle between the supraocciput and the McRae line (p<0.021), and the angle between the tentorium and a line connecting the internal occipital protuberance to the opisthion (p<0.009) were significantly larger in the CMI group than in the control group. The mean vertical length of the cerebellar hemisphere (p<0.003) and the mean length of the coronal and sagittal superoinferior aspects of the cerebellum (p<0.05) were longer in the CMI group than in the control group, while the mean length of the axial anteroposterior aspect of the cerebellum (p<0.001) was significantly shorter in the CMI group relative to control subjects. Conclusion : We elucidate the transformation of the posterior cranial fossa into the narrow funnel shape. The sufficient cephalocaudal extension of the craniectomy of the posterior cranial fossa has more decompression effect than other type extension of the craniectomy in CMI patients.

Characteristics of Particle Separation in Suspension using an Ultrasonic Standing Wave

  • Shin, Beom-Soo;Danao, Mary-Grace C.
    • Journal of Biosystems Engineering
    • /
    • v.37 no.2
    • /
    • pp.113-121
    • /
    • 2012
  • Purpose: Particle separation in solution is one of important process in a unit operation as well as in an extract preparation for biosensors. Contrary to centrifuge-type of mesh-type filter, using an ultrasonic standing wave make the filtering process continuous and free from maintenance. It is needed to investigate the characteristics of particle movement in the ultrasonic standing wave field. Methods: Through the computer simulation the effects of major design and driving parameters on the alignment characteristics of particles were investigated, and a cylindrical chamber with up-stream flow type was devised using two circular-shape PZTs on both sides of the chamber, one for transmitting ultrasonic wave and the other for just reflecting it. Then, the system performance was experimentally investigated as well. Results: The speed of a particle to reach pressure-node plane increased as the acoustic pressure and size of particle increased. The maximum allowable up-stream flow rate could be calculated as well. As expected, exact numbers of pressure-node planes were well formed at specific locations according to the wavelength of ultrasonic wave. As the driving frequency of PZT got close to its resonance frequency, the bands of particles were observed clearer, which meant the particles were trapped into narrower space. Higher excitation voltages to the PZT produced a greater acoustic force with which to trap particles in the pressure-node planes, so that the particles gathered could move upwards without disturbing their alignments even at a higher inlet flow rate. Conclusions: This research showed the feasibility of particle separation in solution in the continuous way by an ultrasonic standing wave. Further study is needed to develop a device to collect or harvest those separated particles.

Observation of the change of the dental implant stability and bone density evaluation methods (골밀도 평가방법과 임플란트 안정성 변화의 관찰)

  • Ko, Sok-Min;Park, Sung-Jae;Kim, In-Soo;Song, Seung-Il;Lee, In-Kyung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.185-192
    • /
    • 2009
  • Purpose: The aim of this study was to examine the correlation of the subjective and the objective evaluation of edentulous ridge bone quality, and to evaluate the change of the dental implant stability in each bone density group for early healing period after implant installation. Methods: Sixty-seven implants(Osstem implant$^{(R)}$, Seoul, Korea) were included in this study. We evaluated the bone density by 2 methods. The one was the subjective method which was determined by practitioner s tactile sense, the other was the objective bone type was based on Hounsfield units. The implant stability in each bone type group was assessed by resonance frequency analyzer(Osstell mentor$^{(R)}$). Data were analyzed for the change of the implant stability, and they were compared to verify the difference of groups at the time of installation, 2, 6, 10, 14 weeks postoperatively. Spearman's correlation was used to demonstrate the correlation between the subjective and the objective evaluation of the bone density, and analysis of variance(ANOVA) was used to analyze the differences of implant stability at each time point. Results: There was no close relation between the subjective and the objective evaluation of the bone density(r=0.57). In the subjective groups, there was statistically significant difference between the type 1 and 3 at 10 weeks and between the type 2 and 3 at 14 weeks. In the objective groups, there was no statistically significant difference between the D 1, 2, 3, 4, and 5 group with regard to RFA from baseline to 14 weeks(P>0.1). Conclusions: The implant stability increased over time during the study, and it was improved with bone density proportionally after 2weeks postoperatively. It is recommended that the decision of bone density is base on Hounsfield unit for implant loading time.

Design of the Near Field Microwave Guide Type of Probe Having Enhanced High Transmission Efficiency and Smaller Beam Spot Area (고 투과 효율과 소형 빔 스팟 면적을 갖는 근접장 마이크로웨이브 도파관 탐침의 설계)

  • Ko, Ji-Hwan;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.12
    • /
    • pp.1058-1063
    • /
    • 2015
  • In this article, we propose a near field microwave scanning probe structure in which two short conducting rods are attached to the center of the ridged(H-type) aperture, thereby reducing significantly the beam spot area while maintaining the high transmission efficiency through the output coupling H-type(ridged) aperture. Here the two short parallel conducting rods seem to play an important role of concentrating the transmitted electromagnetic energy through the H-type aperture and so reducing the beam area for high resolution. For validation of the proposed theory, the near field waveguide probe is fabricated according to the simulated results and its return loss characteristics versus frequencies are measured. The comparison between theory and experiment is seen to be in good agreements.

Doxorubicin Release from Core-Shell Type Nanoparticles of Poly(DL-lactide-co-glycolide)-Grafted Dextran

  • Jeong, Young-Il;Choi, Ki-Choon;Song, Chae-Eun
    • Archives of Pharmacal Research
    • /
    • v.29 no.8
    • /
    • pp.712-719
    • /
    • 2006
  • In this study, we prepared core-shell type nanoparticles of a poly(DL-lactide-co-glycolide) (PLGA) grafted-dextran (DexLG) copolymer with varying graft ratio of PLGA. The synthesis of the DexLG copolymer was confirmed by $^1H$ nuclear magnetic resonance (NMR) spectroscopy. The DexLG copolymer was able to form nanoparticles in water by self-aggregating process, and their particle size was around $50\;nm{\sim}300\;nm$ according to the graft ratio of PLGA. Morphological observations using a transmission electron microscope (TEM) showed that the nanoparticles of the DexLG copolymer have uniformly spherical shapes. From fluorescence probe study using pyrene as a hydrophobic probe, critical association concentration (CAC) values determined from the fluorescence excitation spectra were increased as increase of DS of PLGA. $^1H-NMR$ spectroscopy using $D_2O$ and DMSO approved that DexLG nanoparticles have core-shell structure, i.e. hydrophobic block PLGA consisted inner-core as a drug-incorporating domain and dextran consisted as a hydrated outershell. Drug release rate from DexLG nano-particles became faster in the presence of dextranase in spite of the release rate not being significantly changed at high graft ratio of PLGA. Core-shell type nanoparticles of DexLG copolymer can be used as a colonic drug carrier. In conclusion, size, morphology, and molecular structure of DexLG nanoparticles are available to consider as an oral drug targeting nanoparticles.

Relation of Multiple Neurogenic Tumors in the Spinal Canal to Neurofibromatosis

  • Seol, Ho-Jun;Chung, Chun-Kee;Kim, Hyun-Jib;Lee, Yoon-Kyung;Park, Sung-Hye
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.1
    • /
    • pp.16-22
    • /
    • 2005
  • Objective : The authors characterize a syndrome of multiple neurogenic tumors in the spinal canal, which is unclassifiable by the current National Institute of Health[NIH] criteria for neurofibromatosis. Methods : We retrospectively examined cases in which two or more spinal neurogenic tumors were detected by magnetic resonance[MR] imaging and which had been pathologically confirmed. Eighteen patients were recruited between February 1986 and March 2002. According to NIH criteria, eight cases were neurofibromatosis type 1[NF1], four were type 2[NF2], and six were neither type 1 nor type 2 [Unclassifiable : UC]. The locations of lesions, clinical presentations, radiological findings, and pathological results with immunohistochemistry were reviewed. Results : In the case of NF2, three of four cases were intradural tumors. Pathological examinations revealed neurilemmomas in two of four NF2 and all of the UC cases. In the case of NF1, pathological examinations showed seven neurofibromas and one neurilemmoma. Concerning UC, the age at presentation was middle-aged to late [mean age 48.5, range 35 to 64], which contrasted with ordinary NF2, where patients tended to become symptomatic before 20years of age. The pathological examinations of UC cases revealed neurilemmoma similar to most of NF2 and the immunohistochemical study showed characteristic of NF1. Conclusion : Multiple neurogenic tumors in the spinal canal are an under-recognized disease entity. Further studies for genetic aberration in multiple spinal neurogenic tumors are needed.