• Title/Summary/Keyword: Resonance Coil

Search Result 378, Processing Time 0.037 seconds

A Study on Electrical Characteristics for Coil Winding Number Changes of Eddy Current Bobbin Coil for Steam Generator Tubes in NPPs (원전 증기발생기 전열관 와전류검사용 보빈코일의 권선 수 변화에 대한 전기적 특성 연구)

  • Nam, Min-Woo;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.64-70
    • /
    • 2012
  • Two kinds of eddy current probes are mainly used to perform the steam generator tube integrity assesment in NPPs. The first one is the bobbin probe using for inspection of volumetric defect like a fretting wear. The second one is the rotating probe using for inspection of non-volumetric defect like a crack. The eddy current probe is one of the essential components which consist of the whole eddy current examination system, and provides a decisive data for the tube integrity in accordance with acceptance criteria described in specific procedures. The design of ECT probe is especially important to improve examination results because the quality of acquired ECT data is depended on the probe design characteristics, such as coil geometry, electrical properties, operation frequency. In this study, it is analyzed that the coil winding number of differential bobbin probe affects the electrical properties of the probe. Eddy current bobbin probes for the steam generator tubes in NPPs are designed and fabricated according to the results. Experiment shows that the change in coil winding number has much effects on the optimum inspection frequency determined by the tube geometry and material. Therefore, the coil winding number in bobbin probe is very important in the probe design. In this study, a basis of the coil winding number for the eddy current bobbin probe design for steam generator tubes in NPPs is established.

Design of RF Coil for Low Magnetic-Field Osteoblast Reformation System (저 자기장 조골세포 재형성 시스템용 RF 코일 설계)

  • Mun, Sung Hyuk;Cho, Choon Sik;Kim, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.11
    • /
    • pp.821-827
    • /
    • 2018
  • In devices used for re-forming osteoblasts to treat osteoporosis, a magnetic field is applied from the outside of the bone, and the minerals contained in the bone are aligned in a certain direction and undergo precessional motion. When a $90^{\circ}$ RF pulse is applied by using an RF coil, protons of minerals are brought to an excited state, and phosphorus activity promoting the deposition of osteoblasts in the bone is increased, thereby reshaping the bone. Miniaturizing the RF coil that generates a signal corresponding to the harmonic of the precessional motional frequency by means of the $90^{\circ}$ RF pulse can drastically reduce the overall size of the bone reshaping system. In this study, we propose a methodology for the miniaturization of the RF coil that can be used for osteoblast re-formation using a bone reshaping system. The capacitance of the designed RF coil is 25 pF, the inductance is approximately 100 nH, and the resonance frequency is 96 MHz. The radius of the end ring of the designed RF coil is 18 cm, and the total length of the leg is $2{\times}11.6cm$. The performance of the coil is verified through post-design measurement.

The Effect of Coating Material of Copper-wire RF Coil on the Signal-to-Noise Ratio in MR Images (RF코일로 사용된 구리선 코팅재질이 자기공명영상에서의 신호대잡음비에 미치는 영향)

  • Lee, Hyeon-Seung;Moon, Hye-Young;Chang, Yong-Min;Hong, Kwan-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.171-176
    • /
    • 2009
  • Purpose : To investigate the effect of coating material in RF coil, which is one of main parts in MRI machine, on the Q-factor and SNR(signal-to-noise ratio) in MR images. Materials and Methods : RF coils with inner diameter of 1.7 mm were made by using copper wires coated with polyester, polyurethane, polyimide, polyamideimide, and polyester-imide, and by using copper wires in which coating materials had been removed. Q-factors of the RF coils were measured by network analyzer, and SNR values in the spin-echo MR images obtained by 600 MHz (14.1 T, Bruker DMX600) micro-imaging system for the coated and uncoated cases. Results : The measured SNRs were almost same for the RF coils with coat-removed copper wires, however SNRs and Q-factors were different for the coated cases depending on the coating material. They were maximized in the polyurethane-coated case in which the SNR was > 30% greater than polyester-coated case. Conclusion : We made solenoid-type RF coils which were easily used for MR micro-imaging in Bruker MRI probe. There was a significant coating-material dependence in the measured Q values and SNRs for the home-made RF coils. The study demonstrated that the choice of coating material of RF coil may be a critical factor in the MRI sensitivity based on SNR value.

  • PDF

Noninvasive measuring;Detections of materials and quantities on eddy current testing

  • Obayashi, Koji;Tamura, Muneyoshi;Zhang, X.;Aoyama, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1555-1560
    • /
    • 2004
  • We made a simplified eddy-current-tester, and observed some materials for the ingredients and mass and locations. The tester detects the current as frequency shifts of a LC-resonance circuit, which are caused by the eddy currents. Using air-wick coil and a multi-piled ceramic capacitor, we made a resonance system whose frequency was 100KHz. The shift quantity is few; so, to detect it, we used a frequency counter, and counted the shift. We can detect 10Hz order's shift.

  • PDF

Solution Structure of Bovine Pancreatic Trypsin Inhibitor using NMR Chemical Shift Restraints

  • Park, Kyunglae;Wil
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.1 no.2
    • /
    • pp.79-94
    • /
    • 1997
  • The solution structure of bovine pancreatic trypsin inhibitor(BPTI) has been refined by NMR chemical shift data of C${\alpha}$H using classical molecular dynamics simulation. The structure dependent part of the observable chemical shift was modeled by ring current effect, magnetic anisotropy effect from the nearby groups, whereas the structure independent part was replaced with the random coil shift. A new harmonic function derived from the differences between the observed and calculated chemical shifts was added into physical force field as an pseudo potential energy term with force constant of 250 kJmol-1 ppm-2. During the 1.5 ns molecular dynamics simulation with chemical shift restraints BPTI has accessed different conformation space compared to crystal and NOE driven structure.

  • PDF

Expression and Purification of Unstructured Protein, IMUP-1, using Chaperone Co-expression System for NMR Study

  • Yi, Jong-Jae;Yoo, Jung Ki;Kim, Jin Kyeoung;Son, Woo Sung
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.17 no.1
    • /
    • pp.30-39
    • /
    • 2013
  • Immortalization-upregulated protein-1 (IMUP-1) genes have been cloned and are known to be involved in SV40-mediated immortalization. IMUP-1 gene is highly expressed in various cancer cell lines and tumors, suggesting the possibility that they might be involved in tumorigenicity. Previously, there were several problems for overexpression of IMUP-1 in bacterial expression systems including low solubility and aggregation due to unstructured property. To investigate the structural properties, it is necessary to obtain lots of pure and soluble proteins. Accordingly, the co-expression systems of bacterial chaperone proteins, GroEL-GroES, were used to increase solubility of IMUP-1. From the analysis of NMR and CD experiment data, it is suggested that the protein adopt typical the random coil properties in solution.

Optimal Design Method for an Actively Shielded MRI Superconducting Magnet (능동 차폐 MRI 초전도 자석에 대한 최적 설계 방법)

  • Lee, Kwang-Ho;Cho, Yun-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.421-430
    • /
    • 2000
  • This paper describes an optimal design method which is applied a weighted least square (WLS) method for Magnetic Resonance Imaging (MRI) system. An optimal design approach is presented for a homogeneity superconducting magnet with the superconducting active shield especially for a magnetic resonance imaging system. The WLS is used to obtain the optimal configurations using the least amount and minimum volume of conductor, exhibiting the smallest level of field inhomogeneity and resulting in the least level of stray field. The proposed model is used to design a multiple-shield configuration for a 1.5 T MRI magnet. The field homogeneity is required less than 5 gauss stray field contour within 4m axially and 3m radially from origin. The designed magnet with the actively magnetic shielding coil out of main coils is analyzed by FEM and theoretical analysis method, investigated the field homogeneity.

  • PDF

A STUDY ON TEMPOROMANDIBULAR JOINT DYSFUNCTION WITH MAGNETIC RESONANCE IMAGING AND ARTHROGRAM (자기 공명 영상장치를 이용한 악관절 기능 장애에 관한 연구)

  • Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 1993
  • The Internal derangement of temporomandibular joint disc was evaluated by using magnetic resonance imaging and arthrogram in 5 patients having reciprocal clicking or locking and in 5 normal subjects. Parasagittal multisections on both closed and open mouth were serially obtained by using a 1.5 Tesla MR system and surface coil with CSMEMP, MPGR. MR images obtained were analized by correlating with images of arthrograms. The obtained results were as follows: 1. Displaced meniscus was clearly delineated as dark structure on MR images other than on arthrograms of closed mouth view of patient having clicking or locking. 2. The deltoid white images of synovial fluid were identified in the glenoid fossa and on the posterior surface of condyle on open mouth view and partly depicted on closed mouth view, of parasagittal sections by MPGR. 3. The greyish image of joint fluid was identified on the posterior surface of condyle on the open mouth view of parasagittal sections by CSMEMP. 4. The structural relationship among condyle, meniscus, and fluid showed the variety of images on each parasagitta1 view.

  • PDF

Design of the Shimming Coils for MRI Magnet (MRI 마그네트용 보정코일 설계)

  • Bae, Jun-Han;Go, Rak-Gil;Jin, Hong-Beom;Sim, Gi-Deok;Gwon, Yeong-Gil;Ryu, Gang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.587-591
    • /
    • 2001
  • This paper describes the general and efficient design method of an axial and a radial shim coils to correct field impurities of various harmonic orders in the imaging volume of Magnetic Resonance Imaging magnet. Shim coils are optimized by BCLSF subroutine of IMSL, which is the well-known commercial package for optimization, aiming at maximizing the magnitude of the desired field component as well as minimizing other field components. In order to evaluate their effect, the developed method was applied to the MRI magnet constructed in KERI.

  • PDF

Convex Gradient Coils for an Open Magnetic Resonance Imaging System (개방형 자기공명영상시스템을 위한 볼록형 경사자계코일)

  • 문찬홍;박현욱;조민형;이수열
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.129-136
    • /
    • 2000
  • 중재적 시술을 위한 자기공명영상(MRI)용 주자석은 수직 자계를 가지는 경우가 대부분인데 본 논문에서는 수직 자계를 발생하는 주자석에 장착할 수 있는 볼록형 경사자계코일을 소개하였다. 중재적 시술에 필요한 고속 촬영을 하기 위해서는 강한 경사자계 및 낮은 코일 인덕턱스가 필요한데 본 논문에서는 이를 효율적으로 실현하기 위해 경사자계코일을 볼록 곡면 위에 실현하였다. 기존 방법에서처럼 평면 위에 경사자계코일을 실현하지 않고 볼록 곡면 위에 실현함으로써 경사자계코일의 자계 강도 특성 및 코일 인덕턱스 특성을 향상시킬 수 있을 뿐만 아니라 중재적 시술을 위한 경사자계코일 내 공간을 충분히 확보할 수 있다. Prolate spheroid 좌표계에서 표현되는 경사자계코일 면을 정의하였고, 유한요소법을 이용한 볼록형 경사자계코일 설계 방법을 기술하였다. 또한 경사자계코일 면의 곡률에 따라 경사자계코일의 성능이 어떻게 변화하는지에 대한 결과를 제시하였다.

  • PDF