• Title/Summary/Keyword: Resolution Conversion

Search Result 282, Processing Time 0.031 seconds

Measurement Coding for Compressive Sensing of Color Images

  • Dinh, Khanh Quoc;Trinh, Chien Van;Nguyen, Viet Anh;Park, Younghyeon;Jeon, Byeungwoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • From the perspective of reducing the sampling cost of color images at high resolution, block-based compressive sensing (CS) has attracted considerable attention as a promising alternative to conventional Nyquist/Shannon sampling. On the other hand, for storing/transmitting applications, CS requires a very efficient way of representing the measurement data in terms of data volume. This paper addresses this problem by developing a measurement-coding method with the proposed customized Huffman coding. In addition, by noting the difference in visual importance between the luma and chroma channels, this paper proposes measurement coding in YCbCr space rather than in conventional RGB color space for better rate allocation. Furthermore, as the proper use of the image property in pursuing smoothness improves the CS recovery, this paper proposes the integration of a low pass filter to the CS recovery of color images, which is the block-based ${\ell}_{20}$-norm minimization. The proposed coding scheme shows considerable gain compared to conventional measurement coding.

Development of Independent BPM Control System Using Reflective Memory at PLS (포항가속기의 Reflective Memory를 이용한 독립형 BPM 제어시스템 개발)

  • Yoon, J.C.;Lee, J.W.;Lee, E.H.;Kang, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1697-1698
    • /
    • 2008
  • PLS(Pohang Light Source) is 2.5 Gev synchrotron radiation source in Pohang, Korea, which is under operation since 1995. The hardware and software of the old BPM(Beam Position Monitor) data acquisition system for the PLS storage ring was completely upgraded to increase its performance and stability. The new BPM data acquisition system is based on VME-based EPICS (Experimental Physics and Instrument Control System) IOC system. We used 16-bit resolution analog-to-digital conversion board to digitize analog BPM signals. We developed a data average software to average raw BPM data using reflective memory board. We also developed device drivers for VME I/O boards used, IOC database for PV's(Process Variables). The new BPM data acquisition system is currently running for routine operation with good performance and stability. In this paper, we present the hardware and software of the new BPM data acquisition system DTL water skid cooling system and Resonant Control Cooling.

  • PDF

A Study on Hybrid(Position/Force) Control of Robot Using Time Delay Control (시간지연제어기법을 이용한 로봇의 혼합(위치/힘) 제어에 관한 연구)

  • 장평훈;박병석;박주이
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2554-2566
    • /
    • 1994
  • Robot position/force control has been a difficult task owing to the interaction between a robot and an environment with a rather high stiffness. In addition to the dynamic instability, the interaction causes the following problem : 1) chattering at steady-state, 2) dynamic coupling effect of robot, and 3) performance degradation due to a titled environment. To solve the problem, the Time Delay Control(TDC), which has been known to be quiet robust to plant uncertainties and disturbances, has been applied. In conjunction to TDC, the following three ideas were also used : 1) To reduce the amplitude of the chattering at the steady state, a novel scheme was adopted to enhance the resolution type solution of A/D conversion for the force sensor. 2) To reduce the dynamic coupling, a trajectory type position command was tried on a comparative basis to the step command, as well as a more accurate mass matrix was used instead of the constant mass matrix. 3) And finally to improve the performance in the tilted environment, force derivatives instead of position derivatives were used in the TDC law. Computer simulations and experiments resulted in obvious improvements on the quality of the hybrid control, thereby clearly demonstrating the effectiveness of TDC with the proposed ideas.

Study about Real-time Total Monitoring Technique for Various Kinds of Multi Weather Radar Data (이기종-다중 기상레이더 자료의 실시간 통합 모니터링 기법 연구)

  • Jang, Bong-Joo;Lee, Keon-Haeng;Lim, Sanghun;Lee, Dong-Ryul;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.4
    • /
    • pp.689-705
    • /
    • 2016
  • This paper proposed an realtime total monitoring platform for various kind of multi weather radars to analyze and predict weather phenomenons and prevent meteorological disasters. Our platform is designed to process each weather radar data on each radar site to minimize overloads from conversion and transmission of large volumed radar data, and to set observers up the definitive radar data via public framework server separately. By proposed method, weather radar data having different spatial or temporal resolutions can be automatically synchronized with there own spatio-temporal domains on public GIS platform having only one spatio-temporal criterion. Simulation result shows that our method facilitates the realtime weather monitoring from weather radars having various spatio-temporal resolutions without other data synchronization or assimilation processes. Moreover, since this platform doesn't require some additional computer equipments or high-technical mechanisms it has economic efficiency for it's systemic constructions.

A Study on Optimal Hydrophone Arrangement for The Direction Finding of High Speed Moving Target in Underwater (수중에서 고속 기동하는 표적의 방위 탐지를 위한 최적의 청음기 배치 연구)

  • Han, Min-Su;Choi, Jae-Yong;Kang, Dong-Seok;Son, Kweon;Lee, Phil-ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.369-375
    • /
    • 2017
  • One of good DF(Direction Finding) methods is based on TDOA(Time Difference of Arrival) estimation when finding underwater moving target. For small DF error, high time resolution A/D(Analog-to-digital) conversion board and long baseline are needed. But the result of sea trial about close-range and high speed moving target, spatial correlation coefficient and appeared poor properties below 0.3 when hydrophone arrangement are separated over 6 ${\lambda}$ because of underwater fading channel. And we also find out that the distance between hydrophone should be under 4 ${\lambda}$ apart to take advantage of spatial correlation coefficient gain and performance of DF in underwater moving channel environments.

One-step purification and biochemical characterization of a (s)-stereospecific esterase from Pseudomonas fluorescens KCTC 1767

  • Choe, Gi-Seop;Kim, Ji-Hui;Kim, Ji-Yeon;Kim, Geun-Jung;Yu, Yeon-U
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.445-448
    • /
    • 2002
  • The Pseudomonas fluorescens KCTC 1767, a selected and identified as potential candidate for stereo-specific resolution of rac-ketoprofen ethyl ester, was systematically investigated in order to induce the high level expression and detailed characterization of the expressing enzyme esterase. We cloned the esterase gene from chromosomal DNA of Pseudomonas fluorescens KCTC 1767 by PCR with two synthetic primers that desinged for simple purification. The recombinant esterase from Pseudomonas fluorescens KCTC 1767 exibited a high conversion rate and enantioselectivity to the (S)-ketoprofen ethyl ester as expected. The enzyme was easily purified to homogeniety by using a metal chelating affinity chromatography as a protein with poly histidine taq, and thus obtained 0.6 mg of protein from a 100 mL culture broth in a single step. The purified enzyme was steadily stable at the pH range from 7.0 to 10. The activity was also retained to be about 70% after the preincubation at $40^{\circ}C$ but over $50^{\circ}C$ lost the activity completely. The molecular mass of the esterase was estimated to be about 43 kDa on SDS-PAGE, and an identical result was also shown in gel filteration chromatography. The specific activity was calculated 27 mM/mg-protein/min by using the rac-ketoprofen ethly ester as a substrate.

  • PDF

Effects of Impact Velocity on Crystallization and Activation Energy of Cu-based Bulk Metallic Glasses in Kinetic Spray Coating (저온 분사 코팅 공정에서 충돌속도에 따른 CuNiTiZr 벌크 비정질 소재의 활성화 에너지와 결정화 거동 분석)

  • Yoon, Sang-Hoon;Bae, Gyu-Yeol;Kim, Jung-Hwan;Lee, Chang-Hee
    • Journal of Surface Science and Engineering
    • /
    • v.41 no.6
    • /
    • pp.301-307
    • /
    • 2008
  • In this paper, nanocrystallization of CuNiTiZr bulk metallic glass (BMG) subjecting to a kinetic spraying, dependent on impact velocity, was investigated by numerical and experimental approaches. The crystallization fraction and nucleation activation energy of initial feedstock and as-deposited coating were estimated by DSC and Kissinger method, respectively. The results of numerical modeling and experiment showed that the crystalline fraction and nucleation activation energy in BMG coatings were depended on kinetic energy of incident particle. Upon impact, the conversion of particle kinetic energy leads to not only decreasing free energy barrier but also increasing the driving force for an amorphous to crystalline phase transformation. The nanocrystallization of BMGs is associated with the strain energy delivered by a plastic deformation with a high strain rate.

Study on Heat Transfer Characteristics by Heater Conditions of Hydrogen Sensor for Fuel Cell Electric Vehicle (연료전지 자동차용 수소센서의 히터 조건에 따른 열전달 특성에 관한 연구)

  • Suh, Hocheol;Park, Kyoungsuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.1
    • /
    • pp.23-29
    • /
    • 2013
  • In recent years, development of energy conversion systems using hydrogen as an energy source has been accelerated globally. Even though hydrogen is an environment-friendly energy source, safety and effectiveness issues in storage, transportation, and usage of hydrogen should be clearly resolved in every application. Therefore, sensors for detecting hydrogen leakage, especially for fuel cell electric vehicles, should be designed to have much higher resolution and accuracy in comparison with conventional gas sensors. In this study, we conducted to determine the design parameters for the semiconductor hydrogen sensor with optimized sensing conditions under the thermal distribution characteristic and thermal transfer characteristic. The heat generation study on power supply voltage was studied for correlation analysis of thermal energy according to the power supply voltage variation from 1.0 voltage to 10.0 voltage every 0.5 voltage. And we studied for the temperature coefficient of resistance with hydrogen sensor.

Isotope-Dilution Mass Spectrometry for Quantification of Urinary Active Androgens Separated by Gas Chromatography

  • Lee, Su-Hyeon;Choi, Man-Ho;Lee, Won-Yong;Chung, Bong-Chul
    • Mass Spectrometry Letters
    • /
    • v.1 no.1
    • /
    • pp.29-32
    • /
    • 2010
  • Cross reacting antibodies can cause an overestimation of the results of immunoassays. Therefore, alternative methods are needed for the accurate quantification of steroids. Gas chromatography combined with isotope-dilution mass spectrometry (GC-IDMS) is developed to quantify urinary active androgens, testosterone, epitestosterone and dihydrotestosterone, which are clinically relevant androgens to both hair-loss and prostate diseases. The method devised involves enzymatic hydrolysis with $\beta$-glucuronidase, solid-phase extraction, liquid-liquid extraction using methyl tert-butyl ether and subsequent conversion to pentafluorophenyldimethylsilyl-trimethylsilyl (flophemesyl-TMS) derivatives for sensitive and selective analysis in selected-ion monitoring mode. Flophemesyl-TMS derivatization not only eliminates matrix interference but also has a good peak resolution within a 6 min-run. A selective and sensitive GC technique with flophemesyl-TMS derivatives also allows accurate quantitative analysis of three active androgens when combined with IDMS. The limit of quantification of the three analytes was <50 pg/mL, and extraction recoveries ranged from 91.9 to 102.1%. The precision and accuracy were 1.2~6.5% and 89.0~106.7%, respectively. This GC-IDMS method can be useful for evaluating the drug efficacy and monitoring the biological processes responsible for male-pattern baldness and prostate diseases.

Development of the Natural Frequency Analysis System to Examine the Defects of Metal Parts (금속 부품의 결함 판단을 위한 고유 주파수 분석 시스템 개발)

  • Lee, Chung Suk;Kim, Jin Young;Kang, Joonhee
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.169-174
    • /
    • 2015
  • In this study, we developed a system to detect the various defects in the metallic objects using the phenomenon that the defects cause the changes of the natural resonant frequencies. Our system consists of a FFT Amp, an Auto Impact Hammer, a Hammer controller and a PC. Auto Impact Hammer creates vibrations in the metallic objects when tapped on the surface. These vibrational signals are converted to the voltage signals by an acceleration sensor attached to the metallic part surface. These analog voltage signals were fed into an ADC (analog-digital converter) and an FFT (fast fourier transform) conversion in the FFT Amp to obtain the digital data in the frequency domain. Labview graphical program was used to process the digital data from th FFT amp to display the spectrum. We compared those spectra with the standard spectrum to find the shifts in the resonant frequencies of the metal parts, and thus detecting the defects. We used PCB's acceleration sensor and TI's TMS320F28335 DSP (digital signal processor) to obtain the resolution of 2.93 Hz and to analyze the frequencies up to 44 kHz.