• 제목/요약/키워드: Resistivity type

검색결과 528건 처리시간 0.025초

레독스-흐름 전지용 이온교환막에 관한 연구(II) -상용 이온교환막의 전지특성을 중심으로- (A Study on Ion-exchange Membranes in Redox-flow Battery(II) -Battery Characteristics in Commercial Ion-exchange Membranes-)

  • 이용욱;김용열;강현춘;신석재;이병철;강안수
    • 멤브레인
    • /
    • 제5권3호
    • /
    • pp.109-118
    • /
    • 1995
  • 본 연구에서는 복합막의 합성을 위한 기초연구로 상용막에 대한 전기화학적 물성과 레독스-흐름전지의 충방전실험을 통해 셀저항과 막저항을 특정하였다. 셀저항율과 막저항율은 충전할 때보다 방전할 때가 더 높았으며 동일한 막에서는 충전심도가 커질수록 저항율이 커짐을 알 수 있었다. hydrocarbon type인 Selemion CMV막이 perfluoro type인 nafion 117, 551막보다 저항율이 작음을 알 수 있었으며 2N 염산수용액에서 충전심도가 0%일 때 셀 저항율과 막저항율이 각각 $12.864\Omega \textrm{cm}^2$, $8.751\Omega \textrm{cm}^2$ 였다.

  • PDF

해안연약 지반 조사를 위한 4전극 전기비저항 프로브 (4 Electrical Resistivity Probe for Investigating soft offshore soils)

  • 김준한;윤형구;배명호;정순혁;이종섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.464-475
    • /
    • 2009
  • Electrical resistivity can be used for porosity estimation. In order to improve previously developed ERCP(Electrical Resistivity Cone Probe), 4ERP(4 Electrical Resistivity Probe), which has Wenner array at the tip of probes, has been developed. In properties of current flow Wenner array measures electrical properties of undisturbed area during penetration and relatively correct measurements are guaranteed without polarization. Furthermore, Wenner array equation can estimate electrical resistivity without extra calibration. 4ERP is developed into 2 types, penetration and fixation. Penetration type has wedge-shaped tip. Considering disturbance minimization, fixed type has plane tip. Fixed type 4ERP in consolidation cell measure electrical resistivity increment along porosity decrease, and penetration type 4ERP measured resistivity profile along the depth in chamber. Applying Archie's law, porosity profile was estimated with electrical resistivity. The tests result suggests that 4ERP can be new site investigation equipment with little disturbance.

  • PDF

코어비저항 측정에 미치는 영향요소에 대한 실험적 고찰(Ⅱ) - 시계열자료의 특성과 대표비저항 값의 결정 (Experimental Verification on Factors Affecting Core Resistivity Measurements (II)-Characteristics of Time Series Data and Determination Method of Resistivity)

  • 김영화;최예권
    • 지구물리
    • /
    • 제2권4호
    • /
    • pp.269-276
    • /
    • 1999
  • 암석의 코어비저항 값을 올바르게 결정하기 위한 노력의 일환으로 비저항 측정에 있어서 샘플홀더의 영향을 분석하고 시계열자료로부터 암석의 비저항을 대표할 수 있는 비저항 값을 효과적으로 구하는 방안에 관하여 연구하였다. 샘플홀더에 대한 연구로는 기존의 GS식과 2전극식 방법과 함께 코어시료 표면을 전도성 접착제로 처리한 변형 GS식 및 변형 2전극식을 고안하여 각 특성을 비교하였으며 그 중에서 변형 2전극식이 측정자료의 안정성과 측정의 편이성 측면에서 장점이 있는 것으로 확인되었다. 샘플홀더 및 사용 소스 주파수의 차이에 따라 달리 나타나는 시계열자료의 분포특성에 관한 분석 결과는 최대곡률점을 이용하여 암석의 대표비저항을 결정하는 방법이 효과적임을 보이고 있다.

  • PDF

전기비저항탐사결과와 터널막장 암반분류의 상관성 검토 (A study on the correlation between the result of electrical resistivity survey and the rock mass classification values determined by the tunnel face mapping)

  • 최재화;조철현;류동우;김학규;서백수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.265-272
    • /
    • 2003
  • In this study, the rock mass classification results from the face mapping and the resistivity inversion data are compared and analyzed for the reliability investigation of the determination of the rock support type based on the surface electrical survey. To get the quantitative correlation, rock engineering indices such as RCR(rock condition rating), N(Rock mass number), Q-system based on RMR(rock mass rating) are calculated. Kriging method as a post processing technique for global optimization is used to improve its resolution. The result of correlation analysis shows that the geological condition estimated from 2D electrical resistivity survey is coincident globally with the trend of rock type except for a few local areas. The correlation between the results of 3D electrical resistivity survey and the rock mass classification turns out to be very high. It can be concluded that 3D electrical resistivity survey is powerful to set up the reliable rock support type.

  • PDF

Influence of Ion Isolation on the Resistivity of Different Types of GaN

  • Johra, Fatima Tuz;Jung, Woo-Gwang
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.237.1-237.1
    • /
    • 2011
  • Resistivity of GaN has been investigated under the influence of ion implantation. n-type, p-type and also undoped GaN has been used here. A ring shape pattern of Au was fabricated on GaN film by the photolithography technique. H, He and Ar were used for implantation. The ion implantation energy, fluence and post-implant annealing temperature varied in this research. Because of the making barrier in some selected area using ions, the resistivity changed in all the samples with the change of both fluence and energy. At room temperature, the resistivity of n-type GaN has been increased from $1.9{\times}10-2$ to $17.7{\times}10-2\;{\Omega}-cm$. This is high for He ion. But undoped and p-type GaN showed some anomalous character.

  • PDF

Influence of steel-fiber type and content on electrical resistivity of old-concrete

  • Uygunoglu, Tayfun;Topcu, Ilker Bekir;Simsek, Baris
    • Computers and Concrete
    • /
    • 제21권1호
    • /
    • pp.1-9
    • /
    • 2018
  • Electrical resistivity is a property associated with both the physical and chemical characteristics of concrete. It allows the evaluation of the greater or lesser difficulty with which aggressive substances penetrate the concrete's core before the dissolution of the passive film process and the consequent reinforcement's corrosion begin. This work addresses the steel fiber addition to concrete with two types and various contents from 0% to 1.3%, correlating it with its electrical resistivity. To that effect, 9 different mixes of steel fiber reinforced concrete (SFRC) were produced. The electrical resistivity was evaluated on the on six years aged SFRC by direct measurement at different frequency from 0.1 kHz to 100 kHz. The results indicate that steel fiber content is strongly conditioned by the type and quantity of the additions used. It was also found that long type of fibers has more effect on decreasing the electrical resistivity of concrete than short fibers. Therefore, they increase the corrosion risk of concrete depending on fiber volume fraction and moisture percentage.

A Study on the Dielctric Properties of the PTC $BaTiO_3$ Ceramic Thin Films

  • Im, Ik-Tae;So, Byung Moon
    • 반도체디스플레이기술학회지
    • /
    • 제11권3호
    • /
    • pp.63-67
    • /
    • 2012
  • The films were deposited at evaporator system and were annealed at heat treatment. The films had a dense microstructure with fine grains. The electrical properties of the films were dramatically controlled with annealing. Samples Preparation were analyzed in term of positive temperature coefficient of Resistivity Samples were made in the substrate tempera-true of $400^{\circ}C$ deposition time of 10 hours, and forward power of 210watt. R-T(resistivity-temperature) Characteristics of the samples were investigated as a function of the substrate type and the ambient temperature. The resistivity of the thin film specimens was compared with that of the bulk type specimens. By using RF/DC magnetron sputtering system, we obtained lower resistivity in the thermistor with thin $BaTiO_3$ film than that in the bulk type thermistor.

전기비저항탐사결과와 터널막장 암반분류의 상관성 검토 (A study on the Correlation Between the Result of Electrical Resistivity Survey and the Rock Mass Classification Values Determined by the Tunnel Face Mapping)

  • 최재화;조철현;류동우;김훈;오병삼;강문구;서백수
    • 터널과지하공간
    • /
    • 제13권4호
    • /
    • pp.279-286
    • /
    • 2003
  • 최근의 터널설계에 있어서 지보패턴 선정시 전기비저항탐사 결과를 효과적으로 황용하기 위하여 전기비 저항 역산결과와 암반분류와의 상관관계를 도출해 내고자 하는 시도가 이루어지고 있다. 그러나 전기비저항탐사결과를 고려한 예상지보패턴과 실제로 시공된 지보패턴 결과를 비교한 연구는 찾아보기 힘들다. 본 연구에서는 실제 터널굴진 상태에서 막장관찰에 기초한 암반분류 및 지보패턴 선정과 시공 전 수행한 전기비저항 탐사자료를 비교함으로씨 전기비저항 탐사 결과가 어느 정도의 신뢰도로 이용될 수 있는가를 살펴보고자 한다. 전기비저항 자료와 암반분류의 정량적인 상관성을 얻기 위하여 암반분류값으로 RMR(Rock mass rating)을 기본으로, RCR(rock condition rating), N(Rock mass number), Q-system 등을 이용하였다. 전기비저항탐사는 공간적 해상도가 낮기 때문에 후처리 과정으로 크리깅 기법을 사용하여 해상도를 향상시키고자 하였다. 상관도 분석 결과, 2차원 전기비저항탐사결과는 정성적인 경향을 살펴보는데 적합한 것으로 나타났다 3차원 전기비저항탐사 결과와의 상관관계는 매우 높은 것으로 나타나 신뢰도 높은 암반분류에 적용 가능하리라 예상된다.

스크린 프린팅 공정에 의해 제조된 열전후막모듈의 전기저항에 미치는 금속코팅층의 영향 (Influence of Metal-Coating Layer on an Electrical Resistivity of Thick-Film-Type Thermoelectric Modules Fabricated by a Screen Printing Process)

  • 김경태;구혜영;하국현
    • 한국분말재료학회지
    • /
    • 제18권5호
    • /
    • pp.423-429
    • /
    • 2011
  • Thermoelectric-thick films were fabricated by using a screen printing process of n and p-type bismuth-telluride-based pastes. The screen-printed thick films have approximately 30 ${\mu}m$ in thickness and show rough surfaces yielding an empty gap between an electrode and the thick film. The gap might result in an increase of an electrical resistivity of the fabricated thick-film-type thermoelectric module. In this study, we suggest a conductive metal coating onto the surfaces of the screen-printed paste in order to reduce the contact resistance in the module. As a result, the electrical resistivity of the thermoelectric module having a gold coating layer was significantly reduced up to 30% compared to that of a module without any metal coating. This result indicates that an introduction of conductive metal layers is effective to decrease the contact resistivity of a thick-film-typed thermoelectric module processed by screen printing.

캐나다 아타바스카 분지 부정합형 우라늄광상 물리탐사 사례 (Geophysical Exploration on Unconformity-type Uranium Deposit in Athabaska Basin, Canada)

  • 유영준;김재철
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2009년도 특별 심포지엄
    • /
    • pp.73-87
    • /
    • 2009
  • Geophysical survey for unconformity-type uranium deposit applied to this study area in Athabaska Basin, Canada were carried out airborne TEM and magnetic, resistivity-induced polarization (DC-IP), puser seismic reflection and well-logging method. The results of airborne survey interpreted the lithological boundary, geological structures, and conductors. Also, these results decided to main targets for ground DC-IP survey. The Low resistivity and the high chargeability slices of 3D modeling interpreted from DC-IP survey response for conductors related to hydrothermal alteration zones and fault-controlled graphitic zones occurring at the unconformity-type uranium deposit, and they confirmed by diamond drilling. Seismic results interpreted to lake bottom surface, alluvium layer and intra-sandstone faults. We suggest the resonable field data acquisition of DC-IP method on the land or the lake in Athabaska Basin.

  • PDF