• 제목/요약/키워드: Resistive type superconducting fault current limiter

검색결과 77건 처리시간 0.023초

EMTDC Modeling Method of Resistive type Superconducting Fault Current Limiter

  • Taejeon Huh;Lee, Jaedeuk;Park, Minwon;Yu, In-Keun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.60-65
    • /
    • 2003
  • An effective modeling and simulation scheme of a resistive type Superconducting fault Current Limiter (SFCL) using PSCAD/EMTDC is proposed in this paper. In case of High Temperature Superconducting (HTS) resistive type fault current limiter current limiting is implemented by the ultra-fast transition characteristics from the superconducting (non-resistive) state to the normal (resistive) state by overstepping the critical current density. The states can generally be divided into three sub-states: the superconducting state the quench state and the recovery state respectively. In order to provide alternative application schemes of a resistive type SFCL, an effective modeling and simulation method of the SFCL is necessary. For that purpose, in this study, an actual experiment based component model is developed and applied for the simulation of the real resistive type SFCL using PSCAD/EMTDC. The proposed simulation scheme can be implemented to the grid system readily under various system conditions including sort of faults and the system capacity as well. The simulation results demonstrate the effectiveness of the proposed model and simulation scheme.

PSCAD/EMTDC를 이용한 저항형 초전도한류기의 계통적용분석 연구 (A Study on the Application Analysis of the Resistive type Superconducting Fault Current Limiters using PSCAD/EMTDC)

  • 허태전;방종현;배형택;박민원;유인근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권1호
    • /
    • pp.25-31
    • /
    • 2005
  • Since the discovery of the high temperature superconductors many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means In limit fault current in power systems. HTS resistive type SFCL is based on the ultra fast transition from the superconducting (non resistive) state to the normal (resistive) state by overstepping the critical current density, In this study, the simulation method of resistive type superconducting fault current limiter using EMTDC is proposed and the developed EMTDC model of SFCL is applied to the modeled power network using the Parameters of real system.

계통 저항을 고려한 소용량 저항형 한류기의 초전도 선재 소모 길이 산출 연구 (Design Method for HTS Wire Length of the Small Scale Resistive Type Superconducting Fault Current Limiter Considering System Resistance)

  • 이우승;최석진;장재영;황영진;강재식;양동규;이해근;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.14-18
    • /
    • 2011
  • Electrical system is changing to smart grid which includes the distributed generations with reusable energy sources in these days. The distributed generations are environmentally friendly and have no concern with depletion problem. But dispatching distributed generations can cause an increase of the fault current. Resistive type super conducting fault current limiter is one of the candidates of solution for the large fault problem in smart grid. In this paper, a design method for the wire length of fault current limiter and the result of short circuit test for small scale modules considering system resistance are introduced.

저항형 고온초전도 전류제한기의 사고각에 따른 전류제한 특성 분석 (The Analysis of Current Limiting Characteristics Acceding to Fault Angles in the Resistive Type High-Tc Superconducting Fault Current Limiter)

  • 박충렬;임성훈;박형민;이종화;고석철;최효상;한병성;현옥배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.523-526
    • /
    • 2004
  • According to the continuous demand for power and the growth of electric power utilities, the electric power transmission capacity was increased. The increase of the electric power transmission capacity results in an increase of the fault current level a fault happened. So the superconducting fault current limiter(SFCL) has been reached as the countermeasure for the reduction of the fault current. In this paper, we investigate the fault currents characteristics of resistive type SFCL according to fault angles when AC power source applied. As the fault angles increase, the first peak value of fault current decreased lower. On the other hand, the power burden of SFCL increased.

  • PDF

차폐유도형 고온초전도 전류제한기의 설계 및 특성시뮬레이션 (The Simulation on the Design and the Characteristic of Shielded Inductive $High-T_c$ Superconducting Fault Current Limiter)

  • 임성훈;최명호;이현수;한병성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권3호
    • /
    • pp.173-178
    • /
    • 1999
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter(FCL) were simulated and analyzed. After determining parameters fo design for superconducting tube, iron core and primary coil, simple power system composed of shielded inductive FCL was simulated by the numerical analysis. The currents flowing under the fault condition could be limited below 50 A successfully. It was suggested that as the important factors of operational characteristics, the turns of primary coil and size of iron core play a major role for whether the shielded inductive SCFCL operated as inductive type or resistive type FCL.

  • PDF

고온초전도체를 이용한 차폐유도형 전류제한기의 설계 및 동작 특성해석 (The design and analysis of Operational characteristic of Shielded Inductive Fault Current Limiter using high-$T_c$ Superconducting)

  • 송재주;이재;임성훈;강형곤;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.339-342
    • /
    • 2001
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter(FCL) were simulated and analyzed to search for the parameter to determine FCL operation, Fault current limiting operation can be executed as resistive or inductive type, which is determined by iron-core radius and the number of the primary coil turns. It was considered through this paper that the operation of each was compared and examined about the merit of each mode.

  • PDF

저항형 고온 초전도 전류제한기의 저항변화 분석 (Anaysis of resistance variance of Resistive type high-Tc superconducting fault current limiter)

  • 박형민;최효상;임성훈;박충렬;한병성;정헌상;최창주;현옥배;정동철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.547-550
    • /
    • 2004
  • Superconducting fault current limiter(SFCL) is expected to be introduced into electric power system in future as an effective countermeasure for the increase of the short-circuit current due to the growth of the electric power system. SFCL has a merit that the fault current can be limited by the resistance generated when a superconductor transits from a superconducting state to a normal state without additional detecting device. In this paper, we investigated the resistance variance of resistive type SFCL and the fault current limiting characteristics due to the amplitude of source voltage. We could obtain the more effective fault current limiting characteristics of SFCL as the source voltage increased.

  • PDF

Investigation on the Commercialization Issues of Resistive Type Superconducting Fault Current Limiters for Electric Networks

  • Park, Tae-Gun;Lee, Sang-Hwa;Lee, Bang-Wook
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.19-24
    • /
    • 2009
  • Among the various types of fault current limiters, superconducting fault current limiters could be the most preferable choice for high voltage electric power systems owing to the remarkable current limiting characteristics of superconductors. But, there have been no commercial superconducting fault current limiters which were installed into actual electric power systems until these days due to some remained technical and economical problems. Thus, in order to promote the development and application of the superconducting fault current limiters into real field, it is essential to understand the power utilities’ requirements for their networks and also suitable test method and some specifications should be prepared. This paper focuses on the matters of test requirements and standardization issues that should be prepared for commercialization of superconducting fault current limiters. The unique current limiting characteristics of superconducting fault current limiters were investigated and related other standards including circuit breakers, transformers, reactors, power fuse, and fused circuit breakers were compared to setup the basis of novel specification of superconducting fault current limiters. Furthermore, required essential test procedures for superconducting fault current limiters were suggested.

  • PDF

Manufacture and Test of Small-scale Superconducting Fault Current Limiter by Using the Bifilar Winding of Coated Conductor

  • Yang, Seong-Eun;Ahn, Min-Cheol;Park, Dong-Keun;Jang, Dae-Hee;Ko, Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권4호
    • /
    • pp.20-23
    • /
    • 2005
  • The Resistive Type High Temperature Superconducting Fault Current Limiter (SFCL) has been developed in many countries. Until now, materials of the resistive SFCL were Bi2212 bulk and YBCO thin film. Although YBCO coated conductor (CC) has many advantages such as high n-value and critical current for applying resistive SFCL, the resistive SFCL using CC doesn't have developed yet. The bifilar winding type SFCL was manufactured and tested rated on 30V/80A. In normal state, the SFCL using pancake type bifilar winding had very low impedance. When a fault occurred, the SFCL limited the fault current efficiently. Through these results of experiment, large-scale SFCL using CC should be developed in the future.

저항형 초전도한류기의 신뢰도 모델을 적용한 배전계통 신뢰도 평가에 관한 연구 (A Study on the Evaluation of Distribution Reliability Considering Reliability Model for a Resistive-Type of Superconducting Fault Current Limiter)

  • 김성열;김욱원;김진오
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.465-470
    • /
    • 2011
  • Recently fault currents are increasing in a network. It is caused by increase in electric demand and high penetration of distributed generation with renewable energy sources. Moreover, distribution network has become more and more complex as mesh network to improve the distribution system reliability and increase the flexibility and agility of network operation. Accordingly, the fault current will exceed capacity of circuit breakers soon and all the various rational solutions to solve this problem are taken into account. Under these circumstances, superconducting fault current limiter(SFCL) is a new alternative in the viewpoint of technical and economic aspects. This study presents operation processes for a resistive-type of SFCL, and it proposes reliability model for the SFCL. When a SFCL is installed into a network, the contribution of decreased fault currents to failure for distribution equipments can be quantified. As a result, it is expected that a SFCL makes the reliability of adjacent equipments on existing network improve and these changes are analyzed. We propose a methodology to evaluate the reliability in the distribution network where a SFCL is installed considering a reliability model for resistive-type of SFCL and reliability changes for adjacent equipments which are proposed in this paper.