• Title/Summary/Keyword: Resistance-capacitance

Search Result 459, Processing Time 0.032 seconds

A Study on the Humidity Sensing Properties of Crystalline Carbon Nitride Films (결정성 질화탄소막의 습도 감지특성에 관한 연구)

  • 이지공;하세근;김정훈;이성필
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.521-525
    • /
    • 2004
  • Crystalline carbon nitride films were attempted for an application of humidity sensors. The films were deposited on $Al_2$O$_3$substrate having intermigrated electrodes by reactive rf magnetron sputtering system. The film revealed a good humidity-resistance characteristics as well as humidity-capacitance ones in the humidity range of 10∼95 RH(%). Temperature dependence was also investigated. These results suggest that the carbon nitride film has a possibility for new humidity-sensitive material.

DIRECT ESTIMATION OF PHYSICAL PARAMETERS OF AN RLC ELECTRICAL CIRCUIT BY SIXTEEN CONTINUOUS-TIME METHODS

  • Mensler, M.;Wada, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.526-526
    • /
    • 2000
  • The present has a double objective. The first one is to compare and estimate sixteen continuous-time methods through the identificatiun of a system consisted with an RLC electrical circuit. These sixteen methods are classified into three groups that are the linear filters, the modulating functions and the integral methods. The second objective is to estimate directly the physical parameters of the RLC circuit, without resorting to a discrete-time model. The system is consisted of a coil with inductance L and resistance H, and of a capacitor with capacitance C. Having written the physical equations which describe the behavior of the system, the transfer function in where the initial conditions appear is given. These initial conditions should be taken into account during the parameter estimation phase, because they are inevitable within the framework of real signals. A physical interpretation of the identified models is tempted by the direct estimation of the physical parameters L and C. In conclusion, a classification of the studied methods is proposed.

  • PDF

Design of Low-Power TFT-LCD Source Driver

  • Sung, Yoo-Chang;Choi, Byong-Deok;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.17-18
    • /
    • 2000
  • A low-power source driver for TFT-LCDs has been proposed using the triple charge sharing method that enhances the AC power saving efficiency of the prior charge sharing method. The AC power saving efficiency of the proposed source driver reaches 66.6%. In addition, a novel OP-AMP with low-quiescent current has been developed. The measured quiescent current of the OP-AMP is $5{\mu}A{\sim}7{\mu}A$ at VDD=5V and VSS=0V with load resistance of $2k{\Omega}$ and load capacitance of 300pF.

  • PDF

The Optimal Circuit Condition Selection for Cable Charging Current Test by IEC60265-1 (IEC60265-1에 의한 케이블 충전전류 시험을 위한 최적 회로 조건 선정)

  • Kim, K.D.;Hur, Y.S.;Yun, J.H.;Lee, H.C.;Ham, G.H.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.264-266
    • /
    • 2001
  • We must consider resistance capacitance and their circuit connection condition for cable charging current test by IEC60265-1. According to their values and circuits, the ratio of applied voltage and transient recovery voltage are much different. This paper is convinced of TRV waves and proposes the optical circuit required at the standard via the simulation of all circuit conditions.

  • PDF

공통모드 노이즈 저감을 위한 전력전자모듈

  • Sin, Jong-Won
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.336-337
    • /
    • 2018
  • 전력 전자 시스템 내의 전도성 노이즈는 반도체 스위칭 소자의 고속 동작에 큰 영향을 받는다. 특히 실리콘 카바이드 (SiC) 등의 신소재 반도체 소자 (wide band-gap device, WBG device) 특유의 고속 dv/dt 특성이 전력전자모듈 (power electronics module, PEM) 내의 기생 용량 (parasitic capacitance)에 인가될 경우 상당한 전도성 노이즈의 원인이 되므로 이를 해결할 필요가 있다. 본 논문에서는 유전율이 낮은 재료를 PEM 내부에 사용함으로써 기생 용량을 줄이고, 따라서 공통 모드 전류의 발생 또한 최소화할 수 있는 설계를 제안한다. 제안된 PEM 설계 기법은 외부 필터를 필요로 하지 않으며, PEM 내의 스위칭 소자-방열 소자간 열저항 (thermal resistance)를 증가시키지 않으면서도 기생 용량을 최소화하여 노이즈를 억제한다. 제안된 방법으로 제작된 PEM을 1 kW 출력 100 kHz 스위칭 주파수의 강압형 dc-dc 컨버터에 적용하여 공통모드 전도성 전류가 줄어듬을 증명하였다.

  • PDF

Development of Cylindrical Capacitive-Conductive Sensor to Evaluate Insulating Degradation for FCEV Stack (차량용 연료전지 스택의 절연열화 진단을 위한 원통형 정전용량-전기전도도 센서개발)

  • Kim, Jae-Hoon;Kim, Ju-Han;Kim, Yoon-Hyung;Cui, Jiang-Yue;Han, Sang-Ok;Yong, Gee-Joong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.317-324
    • /
    • 2010
  • It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Consequently it was developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid.

Electrical Characterization of Para-Sexiphenyl Organic Electroluminescenct Devices (Para-sexiphenyl 유기 EL 소자의 전기적 특성)

  • Lee, Yonq-Soo;Park, Jae-Hoon;Choi, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1739-1741
    • /
    • 2000
  • DC current density-voltage and impedance spectroscopy studies have been performed on indium-tin-oxide(ITO)/para-sexiphenyl(6p)/aluminium organic electroluminescent device. The device exhibited a blue color emission, The turn-on voltage of the device is observed at 5V from the current density-voltage measurements. The impedance spectroscopy measurements show that a resonance frequency shift with applied DC bias is observed and a single semi-circle Cole-Cole plot is confirmed. The bias-dependent bulk resistance and bias-independent bulk capacitance is observed.

  • PDF

Modeling of CCP plasma with H2/N2 gas (H2/N2 가스론 이용한 CCP 플라즈마 모델링)

  • Shon, Chae-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.158-159
    • /
    • 2006
  • The resistance-capacitance (RC) delay of signals through interconnection materials becomes a big hurdle for high speed operation of semiconductors which contain multilayer interconnection layers. In order to reduce the RC delay, low-k materials will be used for inter-metal dielectric (IMD) materials. We have developed self-consistent simulation tool that includes neutral-species transport model, based on the relaxation continuum (RCT) model. We present the parametric study of the modeling results of a two-frequency capacitively coupled plasma (2f-CCP) with $N_2/H_2$ gas mixture that is known as promising one for organic low-k materials etching. We include the neutral transport model as well as plasma one in the calculation. The plasma and neutrals are calculated self-consistently by iterating the simulation of both species till a spatiotemporal steady state profile could be obtained.

  • PDF

Properties of Thermal Performance on Stator Coil of Traction Motor by Accelerated Test (견인전동기 고정자 코일의 열적 열화특성)

  • Park Hyun-June;Lee Chang-Moo;Lee Han-Min;Jang Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.606-610
    • /
    • 2003
  • The 200 class insulation system which adopted to traction motor have excellent dielectric strength but weaken to thermal stress therefore deterioration phenomena analysis according to thermal stress is necessary. Accelerated thermal aging tests have been used to determine thermal reliability of stator coils used as traction motor in electric multiple unit. The conventional aging test is carried on according to IEC 60034-18-31 and IEEE Std. 275-1992. Variation in insulation resistance, P.I, capacitance, dielectric loss($tan{\delta}$) and partial discharge are measured during the aging cycle. Sample coils for traction motor were tested by accelerated aging test which composed of heat, vibration and moisture. Reliability and expected life were evaluated on the insulation system for traction motor.

  • PDF

H-Plane Coupling Between Rectangular Microstrip antennas (구형 마이크로스트립 안테나의 H-Plane 상호결합)

  • Ko, Ji-Whan;Cho, Young-Ki;Son, Hyon
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.6
    • /
    • pp.46-52
    • /
    • 1985
  • A theoretical study of mutual coupling effects between two H-plane coupled microstrip patch antennas is presented. The radiation resistance and slot capacitance of a single micro-strip patch are calculated. To investigate the mutual coupling effects, the even and odd mode characteristic impedance and effective dielectric constants are obtained using the coupled microstrip line model. The S-parameter matrix elements 511,512 are used to study the mutual coupling e(facts in S-band frequency ranges for various patch spacings. Theoretical results and measurements are in good agreement.

  • PDF