DOI QR코드

DOI QR Code

Development of Cylindrical Capacitive-Conductive Sensor to Evaluate Insulating Degradation for FCEV Stack

차량용 연료전지 스택의 절연열화 진단을 위한 원통형 정전용량-전기전도도 센서개발

  • Received : 2010.05.11
  • Accepted : 2010.06.17
  • Published : 2010.09.01

Abstract

It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Consequently it was developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid.

Keywords

References

  1. "Hydrogen, Fuel Cells & Infrastructure Technologies Program : Multi-Year Research, Development and Demonstration Plan", Energy Efficiency and Renewable Energy, 2007.
  2. "Activities toward Commercialization of Fuel Cell/Hydrogen Technology in Japan", Goverment of Japan, 2006.
  3. "신재생에너지 워크샵 및 추계학술대회". 에너지관리공단 신재생에너지센터, 2005.
  4. "Handbook of Fuel Cells(Vol. 1-4)", Wolf Vielstich, Arnold Lamm, Hubert A. Gasteiger, John Wiley & Sons Ltd.
  5. IEC 62282-2, "Fuel cell technologies - Part 2: Fuel cell modules", 2007
  6. ISO 23273-3, "Fuel cell road vehicles -Safety specifications- Part 3: Protection of persons against electric shock", 2006
  7. Walter J. ROSSITER, Jr., McClure GODETTE, Paul W. BROWN and Kevin G. GALUK, "An Investigation of the degradation of aqueous ethylene glycol and propylene glycol solutions using ion chromato graphy", Solar Energy Materials, Vol. 11, pp. 455-467, 1985 https://doi.org/10.1016/0165-1633(85)90016-4
  8. B. Hague, Alternating Current Bridge Methods. London, U.K.: Isaac Pitman, 1977
  9. Z. Moron, "Measurements of electrical conductivity of liquids at low frequencies"(in Polish), Oficyna Wydawnicza Politechniki Wroclawskiej, Wroclaw 2003.
  10. IEC 60746, "Expression of performance of electrochemical analyzers, Part 3: Electrolytic conductivity", IEC Publication, 2002
  11. 김주한 외, "전기 절연유의 열화 패턴에 따른 정전용량형 센서의 열화감지특성 평가", 대한전기학회 2004년도 하계학술대회 논문집 C, pp.1829-1831, 2004
  12. 최남호 외, "전기절연유의 열화진단을 위한 정전용량센서개발", 대한전기학회 2003년도 하계학술대회 논문집 C, pp.1609-1611, 2003