Hull form development of the high speed small fishing boat (고속 소형 어선의 기본선행 개발)

  • Lee, Kwi-Joo;Joa, Soon-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.1
    • /
    • pp.68-74
    • /
    • 2008
  • This study is concerned with the development of the basic planing hull form of small fishing boat in 25 knots high speed. A series of model test to determine the optimum performance hull form of actual fishing boat with 10 gross tonnage was carried out for 5 models made available planing hull form in the circulation water channel. Model test was performed with the resistance test to study the hydrodynamic characteristics of model ships and the sinkage and trim measurement to investigate the stability of model ships and also the wave pattern observation to analyze the effectiveness of model ships. As the result, the planing hull form of P-4 with deep V type bow can be derived as the best hull form with good performance especially in ship's resistance efficiency showing less residual resistance and sinkage and trim and the spray effect, etc..

A Study on the strengthening of titania ceramic coating layer on the steel substrate (티타니아 세라믹 熔射皮膜의 强度向上에 관한 硏究)

  • 김영식
    • Journal of Welding and Joining
    • /
    • v.10 no.4
    • /
    • pp.181-189
    • /
    • 1992
  • The purpose of this investigation is to examine the effects of the strengthening treatments on the mechanical properties of the flame-sprayed titania ceramic coating layer. The strengthening treatments for flame sprayed specimens were carried out in 12 different conditions in vaccum furance. The mechanical properties such as microhardness, thermal shock resistance, adhesive strength and erosion resistance were tested for the sprayed specimens after strengthening treatments. And it was clear that the mechanical properties of coating layer were much improved by the strengthening treatments. The results obtained are summarized as follows; 1. It was shown that the metallurgical bond was formed between substrate and coating layer by the strengthening treatments and that thermal shock resistance and adhesive strength were remarkably raised. 2. Microhardness of coating lay was considerably increased by the strengthening treatments. 3. Erosion resistance and porosity of coating layer were slightly improved by the strengthening treatments.

  • PDF

Evaluation of Behavior Characteristics of Geosynthetic Fiber Nail System from the Field Pull-Out Tests (현장인발시험을 통한 섬유형 쏘일네일의 거동특성 평가)

  • Kim, Hong-Taek;Park, Si-Sam;Cho, Byeong-Guk;Jung, Sung-Pil
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.342-347
    • /
    • 2004
  • Excavation nearby the existing structures is being performed vigorously to get the greatest use of land along with fast economic growth in the downtown area. The application of soil nailing system gradually increases because of an advantage of soil nailing system adjacently constructed in the existing structures. In this study, friction resistance by pull-out is considered as main resistance except resistance formed by flexural rigidity of nail observing that resistance of flexural rigidity is about $0{\sim}15\;%$ of whole safety factor according to degree of flexural rigidity in general soil nail wall and application of geosynthetic fiber soil nailing system is evaluated through laboratory tensile strength test and field pull-out test.

  • PDF

High-Accuracy Coastdown Test Method by Distance-Time Measurement: I. Theoretical Background and Discussions on Accuracy Improvements (거리·시간 측정에 의한 고정도 타행시험법 : I. 관련이론 및 정밀도 향상방법 고찰)

  • Hur, N.;Ahn, I.K.;Petrushov, V.A.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.2
    • /
    • pp.51-61
    • /
    • 1995
  • A coast down test mothod has been used to determine the resistance forces on running vehicle due to the aerodynamic drag, rolling resistance and driveline resistance. Most of the tests, however, are based on the Velocity-Time measurements, which require a sophisticated velocity measuring device and contain much error by nature. In the present study a coast down test method based on Distance-Time measurements is introduced, which contains the original idea of Russian scientist Prof. Petrushov along with the suggestions for improvement of the accuracy.

  • PDF

A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements (현장실측에 의한 메시(Mesh)접지저항 출정기법 연구)

  • 한기붕;김삼수;정세중;이상익
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF

A Study on the Appropriateness of Wind Pressure Resistance Test in KS F 2622 (KS F 2622에서 복합계열에 대한 성능 추가시 풍압 저항성 시험 평가방법의 적정성 검토)

  • Kang, Hyo-Jin;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.187-188
    • /
    • 2018
  • In this study, wind pressure resistance test was carried out among the nine test items of KS F 2622 using five types of water-tight material. After comparing the results with the performance range of the current KS F 2622 wind pressure resistance test, it is recommended to check the adequacy of the addition of the combined series.

  • PDF

Evaluation of Chloride Ion Penetration Resistance of Coal Gasification Slag Replaced Concrete (석탄가스화 용융 슬래그 치환 콘크리트의 염화이온 침투 저항성 검토)

  • Cho, Hyeon-Seo;Kim, Min-Hyouck;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.166-167
    • /
    • 2019
  • In this study, to test the performance of concrete used as a concrete admixture as a recycling method of CGS, gypsum was mixed and the chloride ion penetration resistance test of CGS and BFS substituted concrete was conducted. As a result, it was found that without gypsum type test specimen, the CGS sustituted test specimens had lower chloride ion penetration resistance than the BFS substituted specimens. When gypsum was added, it was confirmed that the chloride ion penetration resistance was poor regardless of the type of admixture. In addition, it was confirmed that both admixtures were less resistant to chloride ion penetration than OPC, regardless of the presence of gypsum. However, considering the uneven quality variation of coal, which greatly affects the quality of CGS, further research is needed.

  • PDF

Testbed of Power MOSFET Aging Including the Measurement of On-State Resistance (전력용 MOSFET의 온-상태 저항 측정 및 노화 시험 환경 구축)

  • Shin, Joonho;Shin, Jong-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.3
    • /
    • pp.206-213
    • /
    • 2022
  • This paper presents setting up a laboratory-scale testbed to estimate the aging of power MOSFET devices and integrated power modules by measuring its on-state voltage and current. Based on the aging mechanisms of the component inside the power module (e.g., bond-wire, solder layer, and semiconductor chip), a system to measure the on-state resistance of device-under-test (DUT) is designed and experimented: a full-bridge circuit applies current stress to DUT, and a temperature chamber controls the ambient temperature of DUT during the aging test. The on-state resistance of SiC MOSFET measured by the proposed testbed was increased by 2.5%-3% after 44-hour of the aging test.

Hydraulic performance and flow resistance tests of various hydraulic parts for optimal design of a reactor coolant pump for a small modular reactor

  • Byeonggeon Bae;Jaeho Jung;Je Yong Yu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1181-1190
    • /
    • 2023
  • Hydraulic performance and flow resistance tests were performed to confirm the main parameters of the hydraulic instrumentation that can affect the pump performance of the reactor coolant pump. The flow resistance test offers important experimental data, which are necessary to predict the behavior of the primary coolant when the circulation of the reactor coolant pump is stopped. Moreover, the shape of the hydraulic section of the pump, which was considered in the test, was prepared to compare the mixed-flow- and axial-flow-type models, the difference in the number of blades of the impeller and diffuser, the difference in the shape of the impeller blade and its thickness, and the effect of coating at the suction bell. Additionally, five models of the hydraulic part were manufactured for the experiments. In this study, the differences in performance owing to the design factors were confirmed through the experimental results.

Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites (전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측)

  • Kim, Hak-Soo;Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Kim, Dae-Sik;Lee, Chun-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.201-206
    • /
    • 2013
  • The electrical resistance measurement was investigated as a damage monitoring method. In this study, 0.5 wt% Carbon nanotube reinforced polypropylene (CNT/PP) composites were evaluated under compressive fatigue loading. The shape of specimens was $20^{\circ}$ curved round type. Compression strength and electrical resistance were measured at different sections of specimen during compression. The microcracks of CNT/PP composites were detected based on the changing ratio of electrical resistance. Micro-damage during compressive fatigue test could be detected by electrical resistance measurements. The reason is that the contact points of CNTs in composites decreased under fatigue loading. During compressive fatigue test, larger change of electrical resistance was detected at the microcrack sections. It was proved that microcracks could be detected by electrical resistance measurement under compression test, whereas the real delamination parts were consistent with the predicted results by electrical resistance measurement.