• 제목/요약/키워드: Resistance

검색결과 31,296건 처리시간 0.046초

Pt 나노입자가 분산된 SiO2 박막의 저항-정전용량 관계 (Relation between Resistance and Capacitance in Atomically Dispersed Pt-SiO2 Thin Films for Multilevel Resistance Switching Memory)

  • 최병준
    • 한국재료학회지
    • /
    • 제25권9호
    • /
    • pp.429-434
    • /
    • 2015
  • Resistance switching memory cells were fabricated using atomically dispersed Pt-$SiO_2$ thin film prepared via RF co-sputtering. The memory cell can switch between a low-resistance-state and a high-resistance-state reversibly and reproducibly through applying alternate voltage polarities. Percolated conducting paths are the origin of the low-resistance-state, while trapping electrons in the negative U-center in the Pt-$SiO_2$ interface cause the high-resistance-state. Intermediate resistance-states are obtained through controlling the compliance current, which can be applied to multi-level operation for high memory density. It is found that the resistance value is related to the capacitance of the memory cell: a 265-fold increase in resistance induces a 2.68-fold increase in capacitance. The exponential growth model of the conducting paths can explain the quantitative relationship of resistance-capacitance. The model states that the conducting path generated in the early stage requires a larger area than that generated in the last stage, which results in a larger decrease in the capacitance.

Evaluation of AC Resistance in Litz Wire Planar Spiral Coils for Wireless Power Transfer

  • Wang, Xiaona;Sun, Pan;Deng, Qijun;Wang, Wengbin
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1268-1277
    • /
    • 2018
  • A relatively high operating frequency is required for efficient wireless power transfer (WPT). However, the alternating current (AC) resistance of coils increases sharply with operating frequency, which possibly degrades overall efficiency. Hence, the evaluation of coil AC resistance is critical in selecting operating frequency to achieve good efficiency. For a Litz wire coil, AC resistance is attributed to the magnetic field, which leads to the skin effect, the proximity effect, and the corresponding conductive resistance and inductive resistance in the coil. A numerical calculation method based on the Biot-Savart law is proposed to calculate magnetic field strength over strands in Litz wire planar spiral coils to evaluate their AC resistance. An optimized frequency can be found to achieve the maximum efficiency of a WPT system based on the predicted resistance. Sample coils are manufactured to verify the resistance analysis method. A prototype WPT system is set up to conduct the experiments. The experiments show that the proposed method can accurately predict the AC resistance of Litz wire planar spiral coils and the optimized operating frequency for maximum efficiency.

목본식물 형성층 전기저항에 영향을 주는 환경 요인 (Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants)

  • 김동욱;김민수;이부용
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

스마트폰 사용자가 모바일뱅킹을 사용하지 않는 이유: 소극적 저항과 적극적 저항의 차이를 중심으로 (Why Smartphone Users are Not Using Mobile Banking: Focusing on the Difference between Passive Resistance and Active Resistance)

  • 김종기;김지윤
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제27권3호
    • /
    • pp.81-102
    • /
    • 2018
  • Purpose The purpose of this study is to investigate the reason why smartphone users do not use mobile banking based on Status Quo Bias and to find out whether there is a difference between passive resistance and active resistance. Design/methodology/approach This study made a design of the research model based on Status Quo Bias. SPSS 23.0 and SmartPLS 2.0 were used for the analysis. Multiple group analysis was performed to identify differences between groups. Findings According to the empirical analysis result, this study confirmed that inertia and perceived risk affected smartphone users who do not use mobile banking. According to the type of resistance, the active resistance group(64.2%) was more than the passive resistance group(35.8%), and it was confirmed that there was a difference in the reasons for not using mobile banking between passive and active resistance group. That is, the greatest difference between passive and active resistance groups was found to be perceived risk, which is an assessment of risk.

SABiT 공법적용 인쇄회로기판의 은 페이스트 범프 크기 및 제작 조건에 따른 전기 저항 특성 (Characterization of Electrical Resistance for SABiT Technology-Applied PCB : Dependence of Bump Size and Fabrication Condition)

  • 송철호;김영훈;이상민;목지수;양용석
    • 한국전기전자재료학회논문지
    • /
    • 제23권4호
    • /
    • pp.298-302
    • /
    • 2010
  • We investigated the resistance change behavior of SABiT (Samsung Advanced Bump interconnection Technology) technology-applied PCB (Printed Circuit Board) with the various bump sizes and fabrication conditions. Many testing samples with different bump size, prepreg thickness, number of print on the formation of Ag paste bump, were made. The resistance of Ag paste bump itself was calculated from the Ag paste resistivity and bump size, measured by using 4-point probe method and FE-SEM (Field Emission Scanning Electron Microscope), respectively. The contact resistance between Ag paste bump and conducting Cu line were obtained by subtracting the Cu line and bump resistances from the measured total resistance. It was found that the contact resistance drastically changed with the variation of Ag paste bump size and the contact resistance had the largest influence on total resistance. We found that the bump size and contact resistance obeyed the power law relationship. The resistance of a circuit in PCB can be estimated from this kind of relationship as the bump size and fabrication technique vary.

정보시스템 사용에 대한 종업원들의 저항에 관한 연구 (A Study on Factors causing the employer's Resistance)

  • 이재진;박종혁
    • 경영과정보연구
    • /
    • 제23권
    • /
    • pp.233-260
    • /
    • 2007
  • Now a day, Information and its related system has been more important in our competitive environment. In this situation, there is also an important thing that we must take into consideration, that's the employer's resistance. Until now we have little material concerning the issue, user's resistance. Owing to that, it's a little hard to study the user's resistance against the IS. Dealing with the resistance effectively helps companies save a great deal of cost and build the information system successfully. This paper takes the Markus's theories about user's resistance. According to the theories, there are three keys theories affecting resistance. To sum this, people-oriented theory, system-oriented theory and Interaction theory. To complement the theories, this paper includes another theories related with resistance and takes total seven factors causing user's resistance. Among these seven factors, four factors have a meaningful effect on the user's resistance, that is, Self-efficacy, System Complexity, Threat of the one's status and politics and System Staff's service quality. Managers and system-related company should keep it in mind very carefully, and I hope they make the best use of the result of this study.

  • PDF

배추좀나방의 Fenvalerate에 대한 저항성 발달과 교차저항성 (Development of Fenvalerate Resistance in the Diamondback Moth, Plutella xylostela Linne (Lepidoptera : Yponomeutidae) and its Cross Resistance)

  • 김길하;서영식;이준호;조광연
    • 한국응용곤충학회지
    • /
    • 제29권3호
    • /
    • pp.194-200
    • /
    • 1990
  • Pyrethroid계 살충제 fenvalerate를 공시하여 실내 감수성계통 배추좀나방(Plu tella xylostella L.)을 인위적으로 누대도태한 후 저항성 발달속도와 정도를 조사하고, 이 저항성계통의 타 살충제에 대한 교차저항성 유무와 정도를 검토하였다. 저항성 발달속도는 fenvalerate 24세대 도태계통에서 도태전에 비하여 66.2배 증가하였다. Fenvalerate 도태계통은 pyrethroid계 살충제인 deltamethrin에 145배의 고도의 교차저항성을 나타내었고, alphamethrin, cypermethrin, fenvalerate, permethrin, tetramethrin에 17.4 -45.0배의 교차저항성을 나타내었다. 유기인계 diazinon, dichlorvos, ethoprophos, EPN과 카바메이트계 BPMC, carbaryl, methorny I에서는 2.1-4.3배의 낮은 교차저항성을 나타내었다. 그러나, 유기인계의 acephate, fenitrothion과 카바메트계 carbofuran에 대해서 비교차저항성을 나타내었다.

  • PDF

Streptoalloteichus hindustanus ATCC 31219로부터 아미노글라이코사이드계 항생제에 내성을 지정하는 유전자의 클로닝 및 염기서열 결정 (Cloning and Sequencing of Resistance Determinants to Aminoglycoside Antibiotics from Sterptoalloteichus hindustanus ATCC 31219)

  • 김종우;한재진;최영내;엄준호;윤성준;현창구;서주원
    • 한국미생물·생명공학회지
    • /
    • 제23권4호
    • /
    • pp.384-389
    • /
    • 1995
  • Streptoalloteichus hindustanus ATCC 31219, a nebramycin complex producer, is similar to Streptomyeces tenebrarius in a viewpoint of resistance to a wide range of aminoglycoside antibiotics. S. tenebrarius has resistance mechanisms of 16s rRNA methylation and aminogycoside modification. However, it is not known whether resistance mechanisms of Stall. hindustanus are the same as in S. tenebrarius. Therefore, we have tried to isolate resistance determinants from Stall. hindustanus. Two different types of aminoglycoside resistance determinants were isolated from Stall. hindustanus and expressed in Streptomyces lividans TK24. The apramycin resistance gene (amr) and the tobramycin resistance gene (tmr) isolated from Stall. hindustanus showed broad resistance spectrum against a dozen of aminoglycoside antibiotics. The complete nucleotide sequences of apramycin resistance gene (amr) were determined. The deduced amino acid sequence of the amr gene of Stall hindustanus ATCC 31219 showed extensive sequence homology to the 16s rRNA methylase gene (kamB) of S. tenebrarius.

  • PDF

LSM 및 LSM-YSZ 양극의 임피던스 특성에 미치는 집전층의 효과 (Effect of Current Collecting Layer on the Impedance of LSM and LSM-YSZ Cathode)

  • 문지웅;이홍림;김구대;김재동;이해원
    • 한국세라믹학회지
    • /
    • 제35권10호
    • /
    • pp.1070-1077
    • /
    • 1998
  • Effect of current collecting layer on the cathode was characterized by AC impedance spectroscopy at 800$^{\circ}C$ under flowing air. LSM-YSZ composite cathode showed lower polarization resistance due to the in-crease of triple phase (LSM/YSZ/Pore) boundary length by incorporation of YSZ. Ohmic resistance {{{{ {R }_{1 } }} of LSM-YSZ was higher than that of pure LSM however because in-plane resistance of the cathode was fair-ly high due to its high specific resistivity. To reduce the in-plane resistance of LSM-YSZ cathode cathode side current collecting layer was required. Ohmic resistance {{{{ {R }_{1 } }} was reduced after forming LSM current col-lecting layer on the LSM-YSZ cathode. In case of pure LSM cathode the formation of Pt, or LSCO current collecting layer reduced polarization resistance {{{{ {R }_{p } }} but ohmic resistance {{{{ {R }_{1 } }} was relatively constant. After annealing of LSM cathode with Pt current collector at higher temperature polarization resistance {{{{ {R }_{p } }} was in-creased but ohmic resistance {{{{ {R }_{1 } }} was constant. These phenomena indicate that Pt or LSCo current col-lecting layers act as a catalytic layer for oxygen reduction of pure LSM cathode. LSCO current collector was effective in reducing the ohmic and polarization resistance of LSM-YSZ cathode.

  • PDF

Significance of Clopidogrel Resistance Related to the Stent-Assisted Angioplasty in Patients with Atherosclerotic Cerebrovascular Disease

  • Rho, Gyoung-Jun;Shin, Woo-Ram;Kong, Tae-Sik;Kim, Min-Sun;Lee, Chang-Ju;Lee, Byung-Hee
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권1호
    • /
    • pp.40-44
    • /
    • 2011
  • Objective : To evaluate the prevalence and risk factors of clopidogrel resistance, and association between thromboembolic complications and clopidogrel resistance in patient with stent-assisted angioplasty for atherosclerotic cerebrovascular disease. Methods : Between September 2006 and June 2008, clopidogrel resistance test was performed on 41 patients who underwent stent-assisted angioplasty for atherosclerotic cerebrovascular disease. It was performed before drug administration and about 12 hours after drug administration (loading dose : 300 mg, maintain dose : 75 mg). Two patients were excluded, and 41 patients were included (mean : $67.59{\pm}7.10$ years, age range : 41-79). Among 41 patients, 18 patients had intracranial lesions, and 23 had extracranial lesions. We evaluated the prevalence, risk factors and complications related to clopidogrel resistance. Results : Twenty-one patients (51.2%) showed clopidogrel resistance [intracranial : 10 patients (55.6%), extracranial : 11 patients (47.8%)] and no clopidogrel resistance was seen in 20 patients. Hypercholesterolemia was an indepedent risk factor of clopidogrel resistance. Stent-assisted angioplasty was technically successful in all patients, but acute in-stent thrombosis occurred in 5 patients with intracranial lesions (4 patients with clopidogrel resistance and 1 without clopidogrel resistance). Acute thrombi were completely lysed after intra-arterial infusion of abciximab. Conclusion : There was relatively high prevalence of clopidogrel resistance in patients with atherosclerotic cerebrovascular disease. Hypercholesterolemia was an independent predictive factor of clopidogrel resistance. Acute in-stent thrombosis was more frequently seen in the clopidogrel resistant group. Therefore, clopidogrel resistance test should be performed to avoid thromboembolic complications related to stent-assisted angioplasty for atherosclerotic cerebrovascular disease, especially patients with hypercholeterolemia and intracranial lesion.