• 제목/요약/키워드: Residual Standard Deviation

검색결과 95건 처리시간 0.019초

기체크로마토그래피를 이용한 잔류농약 동시다성분 분석법 (Determination of Simultaneous Analytical Method of Residual Pesticides by Gas Chromatography)

  • 최원조;최계선;이희정;원영준;박흥재;김우성
    • 한국환경과학회지
    • /
    • 제18권12호
    • /
    • pp.1369-1381
    • /
    • 2009
  • The simultaneous determination of residual pesticides was developed using a gas chromatography. In this study, a simple and reliable methodology was improved to detect 175 kinds of residual pesticides by a liquid-liquid extraction procedure, followed by chromatographic analysis by gas chromatography. The 175 kinds of residual pesticides was classified into 4 groups according to the chemical structure, column type, resolution and sensitivity. The soybean sample selected for recovery experiment was not detected any pesticides. The recovery rates were ranged from 70.6% to 119.7% in most pesticides. The relative standard deviation (RSD 0.3~5.6%) was lower than 5.6% in all cases. The limits of detection (LOD) was lower than the maximum residue levels established by Korean legislations. The method has been successfully applied to the analysis of approximately 130 real samples.

Headspace Analysis for Residual Hexane in Vegetable Oil

  • Oh, Chang-Hwan;Kwon, Yong-Kwan;Jang, Young-Mi;Lee, Dal-Su;Park, Jong-Sei
    • Food Science and Biotechnology
    • /
    • 제14권4호
    • /
    • pp.456-460
    • /
    • 2005
  • To enforce the maximum residue limit for residual hexane (0.005 g/kg) in commercially available Korean vegetable oil, convenient and accurate quantification methods were investigated. Using dual surrogate standards, pentane and heptane were dissolved in ethanol, and then added to hexane-tree sunflower oil for setting up the calibration curve. Gas Chromatograph-Flame Ionization Detector with a porous layer open tubular column, indicated good chromatographic separation of hexane from other inhibiting matrix components. The lowest calibration level was $0.5\;{\mu}g/g$, not exceeding a relative standard deviation of 10% (RSD%), and 1.0\;{\mu}g/g$ not exceeding a deviation of 22% RSD% using heptane as an internal standard for the Static headspace analysis by using a headspace auto-sampler and manual injection, respectively. The residual hexane was detected in nine of the samples among 87 vegetable oil samples purchased on the local market.

Validation on Residual Variation and Covariance Matrix of USSTRATCOM Two Line Element

  • Yim, Hyeon-Jeong;Chung, Dae-Won
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권3호
    • /
    • pp.287-293
    • /
    • 2012
  • Satellite operating agencies are constantly monitoring conjunctions between satellites and space objects. Two line element (TLE) data, published by the Joint Space Operations Center of the United States Strategic Command, are available as raw data for a preliminary analysis of initial conjunction with a space object without any orbital information. However, there exist several sorts of uncertainties in the TLE data. In this paper, we suggest and analyze a method for estimating the uncertainties in the TLE data through mean, standard deviation of state vector residuals and covariance matrix. Also the estimation results are compared with actual results of orbit determination to validate the estimation method. Characteristics of the state vector residuals depending on the orbital elements are examined by applying the analysis to several satellites in various orbits. Main source of difference between the covariance matrices are also analyzed by comparing the matrices. Particularly, for the Korea Multi-Purpose Satellite-2, we examine the characteristics of the residual variation of state vector and covariance matrix depending on the orbital elements. It is confirmed that a realistic consideration on the space situation of space objects is possible using information from the analysis of mean, standard deviation of the state vector residuals of TLE and covariance matrix.

GC에서 검출한계 결정을 위한 새로운 접근 방법에 대한 연구 (Study on the new approaching method to determine limit of detection by gas chromatography)

  • 오도석;신경애;이지아;임종호;신미선
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.217-224
    • /
    • 2010
  • The purity methods to determine LOD/LOQ using standard deviation of the residual, intercept and blank by IUPAC and ACS describe many of the pitfalls and pose significant challenges to analytical chemists. Therefore, the aim of this study is the development of the simple, easy, convenient and statistically significant method to determine LOD in quantitative analysis of organic solvents by GC. The new approaching method by linearization in the given concentration range used coefficient of variation ; ${\sigma}_{n-1}$/S(standard deviation, ${\sigma}_{n-1}$ and average, S) of sensitivity(Response/concentration). The comparison of results among the purity methods(IUPAC and ACS) and the linearization have been fulfilled the F-test for standard deviations and t-test for LOD range values. The results of F-test and t-test are satisfied within 95 % confidence level, respectably. The LOD values determined by the new procedure are n-Hexane 0.0116 mg/$m^3$, Toluene 0.0807 mg/$m^3$, and o-Xylene 0.0494 mg/$m^3$. Because the standard deviation of the residual, intercept and blank and the slope of calibration curve are not calculated and the new approaching method use the coefficient of variation of sensitivity by linearization, this new method is simple, easy, convenient and statistically significant. In future, many chemical analysts will expect to applicate and routinely use this method in the all quantitative analysis.

선형모형과 표준편차에 기반한 잡음영상에 효과적인 에지 검출 방법 (An effective edge detection method for noise images based on linear model and standard deviation)

  • 박영호
    • 응용통계연구
    • /
    • 제33권6호
    • /
    • pp.813-821
    • /
    • 2020
  • 최근 다양한 분야에서 사진, 동영상 등과 같이 비정형 데이터를 이용한 연구가 활발하게 진행되고 있다. 이 중에서도 영상을 활용하는 연구들은 영상에 포함된 정보를 사용하기 위하여 많은 영상처리 기법들을 사용하고 있다. 에지 검출은 영상에서 정보를 추출하기 위해 많은 영상처리 응용 프로그램에서 사용되는 기본 도구이다. 그러나 잡음이 포함된 영상은 에지와 잡음이 모두 고주파 성분을 가지고 있기 때문에 에지 검출을 수행하는 것은 매우 어렵다. 본 논문은 잡음이 감소된 에지를 추출하는 방법으로 선형모형과 표준편차를 이용하였다. 화소 블록에 포함된 화소들의 표준편차와 선형모형의 적합으로 얻어진 잔차에 대한 표준편차의 차이로 에지를 검출하였다. 에지 검출의 결과는 영상처리 분야에서 대표적으로 사용되는 소벨 에지 검출기의 결과와 비교하였다. 잡음이 포함되지 않은 영상은 소벨 에지 검출 결과와 제안한 에지 검출의 결과가 유사하게 나타나고, 제안한 방법이 다양한 수준의 잡음이 추가된 영상에서 잡음에 의한 에지가 적게 나타나는 것을 확인하였다.

Solid Phase Microextraction법을 이용한 식품포장재 중의 잔류용제 분석 (Analysis of Residual Solvents in Food Packaging Materials Using Solid Phase Microextraction Method)

  • 서택교;박상현;이윤수;김정한;권익부
    • 한국식품위생안전성학회지
    • /
    • 제14권1호
    • /
    • pp.76-83
    • /
    • 1999
  • Solid phase microextraction (SPME) was used for the determination of 6 standard solvents (methanol, isopropanol, methyl ethyl ketone, ethyl acetate, cyclohexane, toluene) in food packaging materials. SPME method is a solvent-free sample preparation technique in which a fused silica fiber coated with polymeric organic liquid is introduced into the headspace above the sample. SPME method using fiber coated polydimethylisiloxane (PDMS) was compared with static headspace (SHS) method used as a reference. It was found that the optimal adsorption condition using PDMS-SPME method was 2$0^{\circ}C$ for 15 minutes for the standard solvents. Detection limits, linearity, reproducibility and recovery of both SHS and PDMS-SPME methods have been determined using 6 standard solvents. Both methods were characterized by high reproducibility and good linearity. Using SHS methods, the mean recovery of the 6 standard solvents was ranged from 75.5% to 105.8% with a mean relative standard deviation (RSD) of 0.3% to 4.8%. With PDMS-SPME method, the mean recovery of the 6 standard solvents was ranged from 86.7% to 108.3% with a mean RSD of 0.4% to 2.5%. The detection limits of both methods were the same for toluene, cyclohexane and methyl ethyl ketone; those of PDMS-SPME method were higher than those of SHS method for methanol, isopropanol and ethyl acetate. PDMS-SPME fiber shoed excellent adsorption for non-polar solvents such as toluene, while it showed relatively low adsorption for polar solvents such as methanol.

  • PDF

Noise Reduction Using the Standard Deviation of the Time-Frequency Bin and Modified Gain Function for Speech Enhancement in Stationary and Nonstationary Noisy Environments

  • Lee, Soo-Jeong;Kim, Soon-Hyob
    • The Journal of the Acoustical Society of Korea
    • /
    • 제26권3E호
    • /
    • pp.87-96
    • /
    • 2007
  • In this paper we propose a new noise reduction algorithm for stationary and nonstationary noisy environments. Our algorithm classifies the speech and noise signal contributions in time-frequency bins, and is not based on a spectral algorithm or a minimum statistics approach. It relies on calculating the ratio of the standard deviation of the noisy power spectrum in time-frequency bins to its normalized time-frequency average. We show that good quality can be achieved for enhancement speech signal by choosing appropriate values for ${\delta}_t\;and\;{\delta}_f$. The proposed method greatly reduces the noise while providing enhanced speech with lower residual noise and somewhat higher mean opinion score (MOS), background intrusiveness (BAK) and signal distortion (SIG) scores than conventional methods.

A Simple Method for Determining Residual p-arsanilic Acid in Aquatic Products using EDTA-Assisted Solvent Extraction and LC-MRM

  • Min Kyeong Kwon;Ye Bin Shin;Young Min Kim;Jin Hwan Kim;Ji Seong Kim;Yong Seok Choi
    • Mass Spectrometry Letters
    • /
    • 제14권2호
    • /
    • pp.36-41
    • /
    • 2023
  • A simple method was developed to determine residual p-arsanilic acid (ASA), an organo-arsenic compound used as a feed additive, in aquatic products (eel, halibut, and shrimp) using EDTA-assisted solvent extraction and LC-MRM. The method was successfully validated in terms of specificity, linearity (coefficient of determination ≥ 0.995), accuracy (recovery or R, 72.72-78.73%), precision (the relative standard deviation of R, 2.08-6.98%), and sensitivity (the lower limit of quantitation, 5 ppb) according to CODEX guidelines (CAC-GL 71-2009). The use of EDTA in the extraction solvent and water with a suitable pH modifier as the reconstitution solvent may be the key factors for successful results. This is the first method that can be used for monitoring residual ASA in aquatic products using LC-MRM and could contribute to establishing a better aquatic product safety management system.

화학기계적폴리싱(CMP)에 의한 층간절연막의 광역평탄화에 관한 연구 (A Global Planarization of Interlayer Dielectric Using Chemical Mechanical Polishing for ULSI Chip Fabrication)

  • 정해도
    • 한국정밀공학회지
    • /
    • 제13권11호
    • /
    • pp.46-56
    • /
    • 1996
  • Planarization technique is rapidly recognized as a critical step in chip fabrication due to the increase in wiring density and the trend towards a three dimensional structure. Global planarity requires the preferential removal of the projecting features. Also, the several materials i.e. Si semiconductor, oxide dielectric and sluminum interconnect on the chip, should be removed simultaneously in order to produce a planar surface. This research has investihgated the development of the chemical mechanical polishing(CMP) machine with uniform pressure and velocity mechanism, and the pad insensitive to pattern topography named hard grooved(HG) pad for global planarization. Finally, a successful result of uniformity less than 5% standard deviation in residual oxide film and planarity less than 15nm in residual step height of 4 inch device wafer, is achieved.

  • PDF

적층판 결합공정의 불확정성을 고려한 강건최적설계 (A Study on Robust Design Optimization of Layered Plates Bonding Process Considering Uncertainties)

  • 최주호;이우혁;윤병동
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.836-840
    • /
    • 2006
  • Design optimization of layered plates bonding process is conducted to achieve high product quality by considering uncertainties in a manufacturing process. During the cooling process of the sequential sub-processes, different thermal expansion coefficients lead to residual stress and displacement. thus resulting in defects on the surface of the adherent. So robust process optimization is performed to minimize the residual stress mean and variation of the assembly while constraining the distortion as well as the instantaneous maximum stress to the allowable limits. In robust process optimization, the dimension reduction (DR) method is employed to quantify both reliability and quality of the layered plate bonding. Using this method. the average and standard deviation is estimated. Response surface is constructed using the statistical data obtained by the DRM for robust objectives and constraints. from which the optimum solution is obtained.

  • PDF