• 제목/요약/키워드: Residual DC

검색결과 134건 처리시간 0.056초

비대칭 바이폴라 펄스 스퍼터법으로 증착된 VN 코팅막의 미세구조, 결정구조 및 기계적 특성에 관한 연구 (Microstructure, Crystal Structure and Mechanical Properties of VN Coatings Using Asymmetric Bipolar Pulsed dc Sputtering)

  • 전성용;정평근
    • 한국표면공학회지
    • /
    • 제49권5호
    • /
    • pp.461-466
    • /
    • 2016
  • Nanocrystalline vanadium nitride (VN) coatings were deposited using asymmetric bipolar pulsed dc sputtering to further understand the influence of the pulsed plasmas on the crystal structure, microstructure and mechanical properties. Properties of VN coatings were investigated with FE-SEM, XRD and nanoindentation. The results show that, with the increasing pulse frequency and decreasing duty cycle, the coating morphology changed from a porous columnar to a dense structure, with finer grains. Asymmetric bipolar pulsed dc sputtered VN coatings showed higher hardness, elastic modulus and residual compressive stress than dc sputtered VN coatings. The results suggest that asymmetric bipolar pulsed dc sputtering technique is very beneficial for the reactive sputtering deposition of VN coatings.

병행 2회선 송전선로의 개선된 거리계전기법 (Advanced Distance Relaying of on a Double Circuit Transmission Line)

  • 박철원
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.23-31
    • /
    • 2015
  • This paper proposes an advanced distance relaying based on the DC offset removal filter to minimize the effects of DC offset on a double circuit transmission line. The proposed DC offset removal filter uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. This proposed distance relaying uses not only the residual current of the faulted circuit but also mutual current of the healthy adjacent circuit. A series of off-line test results using ATP simulation data show the effectiveness of the an advanced distance relaying.

6.6kV XLPE Cable의 잔류 전압 특성 (The residual voltage properties of 6.6kV XLPE Cable)

  • 이창훈;오재형;오광영;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1632-1634
    • /
    • 1998
  • In this paper, the study of influence of DC voltage and AC voltage on residual voltage of XLPE Cable was presented. In the former case, when the DC voltage of -10.0[kV] was applied to XLPE Cable for 0, 600, 1200, 1800[sec], time constants were 2139, 1416, 939, 488[sec] and resistivities were 930, 615.65, 408.26, 212.17[${\Omega}{\cdot}m$] respectively. In the latter case, when the AC voltage of 4 and 6[kV] was applied to the same Cable for 600[sec] after applying DC voltage of -5.0[kV] for 600[sec], time constants were 215, 275[sec] and resistivities were 93.48, 119.57[${\Omega}{\cdot}m$] respectively. In this experiments, measurement voltage, charging time and measurement time were -8.0[kV], 30[sec], 600[sec] respectively.

  • PDF

Pulsed DC Power Magnetron Sputter System을 사용한 Copper 박막 특성 조절 (Control of Copper Thin Film Characteristics by using Pulsed DC Power Magnetron Sputter System)

  • 김도한;이수정;김태형;이원오;염원균;김경남;염근영
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.107-107
    • /
    • 2017
  • 전자제품의 성능이 향상됨에 따라서 전자제품에 사용되는 부품의 고집적화가 필연적으로 요구되고 있으며, 고집적화 된 전자제품의 방열(heat dissipation)에 관한 문제점이 대두되고 있다. 방열은 전자기기의 성능과 수명을 유지하는데 있어서 중요한 문제 중 하나로서 방열 효과를 높이기 위해 다양한 연구 개발이 진행 중이다. 방열에 사용되는 소재로는 Cu가 있으며, 저렴한 가격과 상대적으로 높은 방열 효율을 가지는 장점이 있다. Cu는 전기 도금 증착 방법을 사용하여왔으나, 전기도금 방식으로 증착된 Cu 방열판은 제품에 열이 축적될 경우 Cu와 substrate 사이의 residual stress로 인해 박리나 뒤틀림 현상 등이 발생하여 high power를 사용하는 device의 방열 소재로 사용하기에는 개선해야 할 문제점이 있다. 이러한 문제점을 극복하기 위한 방법으로 magnetron sputter 증착 방법이 있으며, magnetron sputter은 대면적화가 용이하고, 다양한 물질의 증착이 가능한 장점으로 인해 hard coating 또는 thin film 증착과 같은 공정에 사용되고 있다. 특히 증착된 film의 특성을 조절하기 위해서 magnetron sputter에 pulse 또는 ICP (inductively coupled plasma) assisted 등을 적용하여 plasma 특성을 조절하는 방법 등에 관한 연구가 보고되고 있다. 본 연구에서는 pulsed magnetron sputtering 방식을 이용하여 증착된 Cu film 특성 변화를 확인하였다. 다양한 pulsing frequency와 pulsing duty ratio 조건에서, Si substrate 위에 증착된 Cu film과의 residual stress 변화를 측정하였다. Pulse duty ratio가 90% 에서 60%로 감소함에 따라서 Cu film의 residual stress가 감소하였고, pulsing frequency가 증가함에 따라 Cu film의 residual stress가 감소하는 것을 확인하였다. 증착 조건에 따른 plasma의 특성 분석을 위하여 oscilloscope를 이용하여 voltage와 current를 측정하였고, Plasma Sampling Mass spectrometer 를 이용하여 ion energy의 변화를 측정하였다. 이를 통해 plasma 특성 변화가 증착된 Cu film에 미치는 영향과 residual stress의 변화에 대한 연관성에 대하여 확인할 수 있었다.

  • PDF

수지상세포를 이용한 항암 면역 치료: 생쥐 신장암 모델을 이용한 연구 (Dendritic Cell Based Cancer Immunotherapy: in vivo Study with Mouse Renal Cell Carcinoma Model)

  • 이현아;최광민;백소영;이홍기;정철원
    • IMMUNE NETWORK
    • /
    • 제4권1호
    • /
    • pp.44-52
    • /
    • 2004
  • Background: As a potent antigen presenting cell and a powerful inducer of antigen specific immunity, dendritic cells (DCs) are being considered as a promising anti-tumor therapeutic module. The expected therapeutic effect of DCs in renal cell carcinoma was tested in the mouse model. Established late-stage tumor therapeutic (E-T) and minimal residual disease (MRD) model was considered in the in vivo experiments. Methods: Syngeneic renal cell carcinoma cells (RENCA) were inoculated either subcutaneously (E-T) or intravenously (MRD) into the Balb/c mouse. Tumor cell lysate pulsed-DCs were injected twice in two weeks. Intraperitoneal DC injection was started 3 week (E-T model) or one day (MRD model) after tumor cell inoculation. Two weeks after the final DC injection, the tumor growth and the systemic immunity were observed. Therapeutic DCs were cultured from the bone marrow myeloid lineage cells with GM-CSF and IL-4 for 7 days and pulsed with RENCA cell lysate for 18 hrs. Results: Compared to the saline treated group, tumor growth (E-T model) or formation (MRD model) was suppressed in pulsed-DC treated group. RENCA specific lymphocyte proliferation was observed in the RENCA tumor-bearing mice treated with pulsed-DCs. Primary cytotoxic T cell activity against RENCA cells was increased in pulsed-DC treated group. Conclusion: The data suggest the possible anti-tumor effect of cultured DCs in established or minimal residual disease/metastasis state of renal cell carcinoma. Systemic tumor specific immunity including cytotoxic T cell activity was modulated also in pulsed-DC treated group.

폐암의 면역세포 치료: 동물 모델에서 수지상 세포를 이용한 Adjuvant Therapy 가능성 연구 (Immunocell Therapy for Lung Cancer: Dendritic Cell Based Adjuvant Therapy in Mouse Lung Cancer Model)

  • 이석재;김명주;인소희;백소영;이현아
    • IMMUNE NETWORK
    • /
    • 제5권1호
    • /
    • pp.36-44
    • /
    • 2005
  • Background: The anti-tumor therapeutic effect of autologous tumor cell lysate pulseddendritic cells (DCs) was studied for non-immunogenic and immune suppressive lung cancer model. To test the possibility as an adjuvant therapy, minimal residual disease model was considered in mouse in vivo experiments. Methods: Syngeneic 3LL lung cancer cells were inoculated intravenously into the C57BL/6 mouse. Autologous tumor cell (3LL) or allogeneic leukemia cell (WEHI-3) lysate pulsed-DCs were injected twice in two weeks. Intraperitoneal DC injection was started one day (MRD model) after tumor cell inoculation. Two weeks after the final DC injection, tumor formation in the lung and the tumor-specific systemic immunity were observed. Tumor-specific lymphocyte proliferation and the IFN-${\gamma}$ secretion were analyzed for the immune monitoring. Therapeutic DCs were cultured from the bone marrow myeloid lineage cells with GM-CSF and IL-4 for 7 days and pulsed with tumor cell lysate for 18 hrs. Results: Compared to the saline treated group, tumor formation was suppressed in 3LL tumor cell lysate pulsed-DC treated group, while 3LL-specific immune stimulation was minimum. WEHI-3-specific immune stimulation occurred in WEHI-3 lysate-pulsed DC treated group, which had no correlation with tumor regression. Conclusion: The data suggest the possible anti-tumor effect of cultured DCs as an adjuvant therapy for minimal residual disease state of lung cancer. The significance of immune modulation in DC therapy including the possible involvement of NK cell as well as antigen-specific cytotoxic T cell activity induction was discussed.

직류환경에서 인체에 흐르는 감전전류 분석 (Analysis on Electric Shock Current in DC Electricity)

  • 이진성;김효성
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.254-259
    • /
    • 2016
  • Recently, DC distribution systems have become a hot issue because of the increase in digital loads and DC generation systems according to the expansion of renewable energy technologies. To obtain the practical usage of DC electricity, safety should be guaranteed. The main concerns for safety are twofold: one side is human protection against electric shocks, and the other is facility protection from short faults. "Effects of current on human beings and livestock" (IEC 60479) defines a human body impedance model in electric shock conditions that consists of resistive components and capacitive components. Although the human body impedance model properly works in AC electricity, it does not well match with the electric shock behavior in DC electricity. In this study, the contradiction of the human body impedance model defined by IEC 60479 in case of DC electricity is shown through experiments for the human body. From the analysis of experimental results, a novel unified human body impedance model in electric shock conditions is proposed. This model consists of resistive components, capacitive components, and an inductance component. The proposed human impedance model matches well for AC and DC electricity environments in simulation and experiment.

Study on DC-Offset Cancellation in a Direct Conversion Receiver

  • 박홍원
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.157.2-157.2
    • /
    • 2012
  • Direct-conversion receivers often suffer from a DC-offset that is a by-product of the direct conversion process to baseband. In general, a basic approach to reduce the DC-offset is to do simple average of the baseband signal and remove the DC by subtracting the average. However, this gives rise to a residual DC offset which degrades the performance when the receiver adopts the coding schemes with high coding rates such as 8-PSK. Therefore, more advanced methods should be additionally required for better performance. While the training sequences are basically designed to have good auto-correlation properties to facilitate the channel estimation, they may be not good for the simultaneous estimation of the channel response and the DC-offset. Also the DC offset compensation under a bad condition does not give good results due to the estimation error. Correspondingly, the proposed scheme employs the two important points. First, the training sequence codes are divided into two groups by MSE(Mean Squared Errors) for estimating the channel taps and then SNR calculated from each group is compared to predefined threshold to do fine DC-offset estimation. Next, ON/OFF module is applied for preventing performance degradation by large estimation error under severe channel conditions. The simulation results of the proposed scheme shows good performances compared to the existing algorithm. As a result, this scheme is surely applicable to the receiver design in many communications systems.

  • PDF

철도전력망을 이용한 EV DC 충전설비 배터리 잔존용량에 따른 충전효율 가변성 연구 (A Study on Charging Efficiency Variability by Utilizing Remaining Capacity of EV DC Charging Facility Batteries of Railway Electric Power Grids)

  • 김기석;정호성;박영;박찬배;박철민;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2171-2172
    • /
    • 2011
  • Recently, while interests on supply of electric vehicles have increased there still are insufficient charging facilities. As a solution to this matter, using electric power grids that constantly retain about 30~50[%] residual power is being considered. Therefore proposed in this paper railway, is a method to establish a charging infrastructure to utilize railway DC power grids. In addition we designed a high-speed DC charging system, and simulated improvements of the charging structure's charging efficiency according to remaining capacity of batteries.

  • PDF

DC 스퍼터법과 유도결합 플라즈마 마그네트론 스퍼터법으로 증착된 수퍼하드 TiN 코팅막의 물성 비교연구 (A Comparative Study of Superhard TiN Coatings Deposited by DC and Inductively Coupled Plasma Magnetron Sputtering)

  • 전성용
    • 한국표면공학회지
    • /
    • 제46권2호
    • /
    • pp.55-60
    • /
    • 2013
  • Superhard TiN coatings were fabricated by DC and ICP (inductively coupled plasma) assisted magnetron sputtering techniques. The effect of ICP power, ranging from 0 to 300 W, on coating microstructure, preferred orientation mechanical properties were systematically investigated with HR-XRD, SEM, AFM and nanoindentation. The results show that ICP power has a significant influence on coating microstructure and mechanical properties of TiN coatings. With the increasing of ICP power, coating microstructure evolves from the columnar structure of DC process to a highly dense one. Grain sizes of TiN coatings were decreased from 12.6 nm to 8.7 nm with increase of ICP power. The maximum nanohardness of 67.6 GPa was obtained for the coatings deposited at ICP power of 300 W. Preferred orientation in TiN coatings also vary with ICP power, exerting an effective influence on film nanohardness.