• Title/Summary/Keyword: Residential water

Search Result 467, Processing Time 0.031 seconds

Establishment of Design Factors and Procedure for Permeable Asphalt Pavements Structural Design (투수성 아스팔트 포장 구조설계를 위한 설계인자 도출 및 설계방법에 관한 연구)

  • Yoo, Hyun Woo;Oh, Jeongho;Jung, Young Wook;Han, Shin In
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.113-119
    • /
    • 2018
  • An extensive effort is actively being made to implement permeable pavement systems in urban or residential areas of South Korea in order to achieve efficient water circulation system based on low impact development (LID) design concept. This study aims to establish the design factors and procedure for permeable asphalt pavements structural design. Based on the review of previous studies, the 1993 AASHTO design method is found to be adequate for permeable pavements structural design. In this study, the design program based on 1993 AASHTO design procedure in conjunction with domestic roadway design standards was developed to accommodate the characteristics of permeable asphalt pavements. Primary design parameters such as structural layer coefficients of permeable materials were successfully quantified based on literature reviews and parallel analyses. Comparable design thicknesses were obtained between the developed permeable pavement design (PPD) program and Korea pavement research program (KPRP) under different levels of traffic and subgrade load bearing capacity.

Residential Humidifying Element Made of Cellulose and PET Composite (셀룰로오스와 PET 복합체로 만들어진 가정용 가습소자)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.13-18
    • /
    • 2016
  • Humidifiers are used to control indoor humidity. Element-type humidifiers have the advantages of simple structure and low energy consumption, and Japanese products have been widely used for the humidifying elements. In this study, a new humidifying element made of cellulose and PET was developed, and the performance was compared with that of a Japanese element. The mass transfer rates and pressure drops were measured for an element installed at the entrance of a suction-type wind tunnel. The humidification efficiency of the new element was 2 to 4% greater and the pressure drop was 23 to 32% smaller compared to the Japanese element. The mass transfer effectiveness ($j_m/f$) of the new element is also 5 to 28% higher. However, the water absorption capacity was smaller than that of the Japanese element, meaning further development is needed.

21세기 유럽 해항도시의 롤 모델로서의 하펜시티 함부르크

  • Jeong, Jin-Seong;Jo, Hyeon-Cheon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.06a
    • /
    • pp.376-378
    • /
    • 2011
  • Hamburg is going with the HafenCity Project to create new urban space for city's bustling central district. HafenCity will add an additional 155 hectares to Hamburg's central urban area, increasing its total area by some 40 percent. The new developments in HafenCity will be oriented towards the River Elbe and the great seaport. Its centre will have a close relation to water. They will be used for the construction of a fascinating mix of residential accommodation, offices, cultural and leisure amenities, retail facilities and restaurants set in a framework of an elaborate urban layout. This study is focusing on the purpose of the project goals, the task of the Hamburg authorities and GHS (Gesells chaft f$\ddot{u}$r Hafen und Standortentwicklung) and an urban planning ideas competition (draft masterplan). Regarding of the new trend of the reurbanisation in Europe, the aim of this study will be to find out, in which way Hafencity is trying to develope the new city district as a model for the European inner city of the 21st century.

  • PDF

A study on the Energy resource in School Buildings with the Changes of Educational Facilities Standard (교육 시설기준 변화에 따른 학교건축물의 에너지원 변화에 관한 연구)

  • Kim, Tae-Woo;Lee, Kang-Guk;Hong, Won-Hwa
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • Since the Korean War, Korea has experienced modernization. The population increase by baby booming has asked for more space for educational facilities. In such a situation, the purpose of educational facilities was to accommodate continuously increasing students, rather than seeking for quantitative demands. In addition, in accordance with social changes, educational shifts were required. After the revision of the seventh national curriculum in education in 1997, the school buildings became varied. The design of buildings in accordance with educational curriculum has been improved, but still lack of forming comfortable environment and considering energy efficiency in school buildings. For the improvement of educational environments, educational media such as TV and computers have been provided, and energy systems, including heating and cooling systems, has been continuously increased. As a result, it appeared that energy use in school buildings and facilities has been steadily increased and that the structure of energy consumption has been also changed, especially with regard to electricity use. Living in the 21st century, human beings face global environmental issues, such as global warming, geographical climate changes, and ozone destruction that are the consequences of fossil energy use. Therefore, even in industrial areas, considering a counterplan for low energy use is being paid attention. Starting with Kyoto Protocol in 1992, people try to decrease carbon dioxide and to develop alternative energies (i.e. natural energy); for example, solar energy, wind force, terrestrial heat, and water power. Advanced countries already set up a criterion for $CO_2$ decrease ranging from office buildings to residential houses and also propose alternatives for the $CO_2$ decrease. However, there is no such a plan for low energy use and $CO_2$ decrease in school facilities, and any research on the actual conditions was not accomplished. Thus, this study examines energy demand in classrooms that take up a large portion of energy demand in school building structure.

To reduce carbon from residential architecture Research on energy-saving elements (주거건축에서 탄소를 줄이기 위한 에너지 절감 요소에 관한 연구)

  • Park, Jae-Hee
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.47-52
    • /
    • 2009
  • Currently, the environmental issue is of great urgency and sensitivity to the future of our planet. Global warming caused by increased CO2 concentration has an alarming impact on the earth's fragile environment. Droughts throughout the world are causing crop failures. Wildfires now burn with far greater rage. Melting ice caps and glaciers are causing floods. Sea levels are rising. Warm unseasonable winters are threatening our fragile eco-systems. Global warming is no longer a theory; it is an obvious fact we are confronted with every day, and the only way we can prevent it is to take action now. The need to reduce CO2 emissions and try to become carbon neutral is of national importance and leadership. We have become so reliant on fossil fuels that nearly everything we do generates CO2 emissions; from our modern farming practices to transport, to the electricity used to turn on a light, boil water in a kettle or cook our meals. A reduction of 50% of CO2 emissions can easily be achieved by decreasing the energy amount used. We tracked the carbon footprint throughout the electricity and heating energy use in homes and confirmed the amount of carbon emissions according to its consumptions. In order to reduce the carbon generation from housing constructions, such as Passive House concept of buildings or low energy buildings, we must adjust its applications best fit to our conditions. And technical elements should be applied to improve our conditions, and the methodology should be actively sought. Most of all, each individual's recongnition who uses these elements is more important than any other solutions.

Zero-Crack Construction on the Fundamental Mass Concrete Using Double Bubble Sheets and Applying Low Heat Mixture (저발열 배합 및 이중버블시트에 의한 기초 매트 매스 콘크리트의 무균열 시공)

  • Park, Yong-Kyu;Song, Sung-Bin;Baek, Byung-Hoon;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.5-8
    • /
    • 2006
  • This study investigates the field application, Songdo the # 1st WORLD, on zero-crack construction of the fundamental mass concrete using double bubble sheets and applying low heat mixture. Experimental results of hydration heat analysis showed that crack modulus of concrete incorporating 20% of blast furnace slag cement was 1.0 in 120 hours, representing 50% probability of crack occurrence, thus requiring additional measures. As for a curing method, a specimen insulating two layers of vinyl chloride+double bubble sheets exhibited only $16.5^{\circ}C$ difference between upper and lower sections, and it also showed favorable workability as well as competitive economic side. Therefore it was determined to use it for curing method in this field. For the curing results of practical field, using 2 layers of vinyl chloride+double bubble sheets and applying low heat mixture on the fundamental mass concrete in 3A residential building exhibited less than only $15^{\circ}C$ difference between surface and center section of that in 5 days elapse and less than $20^{\circ}C$ in 9 days. This means that the crack by hydration heat was prevented, and other fields structures also resisted the plastic shrinkage by insulating the vinyl, sinking crack by second temping, even drying shrinkage by the mixture of low unit water. Therefore the crack on the placement has not been found so far, since the construction was started before 6 month.

  • PDF

Evaluation of 2 Part Curtainwall Structural Silicone Sealant (커튼월용 2액형 구조용 실란트 혼합비별 물성 평가 연구)

  • Kim, Sung Hyun;Jung, Jin-young;Ahn, Myung-Su;Seo, YeonWon;Bae, Keesun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.78-80
    • /
    • 2014
  • Silicone structural glazing (SSG) is a method utilizing a silicone adhesive to attach glass, metal, or other panel material to the structure of a building. Windload and other impact loads on the facade are transferred from the glass or panel through the silicone structural sealant to the systems' framework. Silicone structural glazing systems are currently a very common method of glazing throughout the world. Locally, structural silicone glazing has become very common to achieve aesthetically pleasing and high utilization of small land for both residential and commercial building. Although structural silicone glazing has been utilized for approximately thirty years in Korea, the understanding of its technology was low and limited. Consequently, Korean projects experienced many quality issues during assembly and construction, even in very recently finished buildings. Adhesion loss and water infiltration occurred on more than one project, and the time and cost to repair these issues were substantial. In general, there are two kinds of structural silicones depending on fabrication methods. 1part structural silicone is for site glazing system and 2part structural silicone is for unitized factory glazing system. In this paper, 2part structural silicone which is very common for factory fabricating curtainwall systems was evaluated with regards to various mixing ratio. Since the structural performance of 2part sealant can be affected by mixing ratios, some extra ranges of recommended mixing ratio were evaluated to see any performance differences. Besides on cure profile, comparative evaluations for mechanical properties and adhesion develop on common building substrates were conducted.

  • PDF

Effect of the Urban Land Cover Types on the Surface Temperature: Case Study of Ilsan New City (도시지역의 토지피복유형이 지표면온도에 미치는 영향: 경기도 일산 신도시를 중심으로)

  • Kim, Hyun-Ok;Yeom, Jong-Min
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.2
    • /
    • pp.203-214
    • /
    • 2012
  • The physical environment of urban areas covered mostly by concrete and asphalt is the main cause of the urban heat island effect, primarily becoming apparent through increased land surface temperature. This study examined the effect of different urban land cover types on the land surface temperature using MODIS, Landsat ETM+ and RapidEye satellite data. As a result, the remote sensing based land surface temperature showed a marked difference according to the land use pattern in the case study of Ilsan new city. The high-rise apartment residential districts with less building-to-land ratio and higher green area ratio revealed lower land surface temperature than the low-story single-family housing districts characterized by relatively high building-to-land ratio and low green area ratio. From the view of climate zone and land cover types, there is a strong linear correlation between the impervious land cover ratio and the land surface temperature; the land surface temperature increases as the impervious built-up areas expand. In contrast, vegetation;water and shadow areas affect the decrease of land surface temperature. There is also a negative (-) correlation between NDVI and land surface temperature but the seasonal variation of NDVI can be hardly corrected.

Use of Housing through Oral Life History of Korean Chineses in Harbin, China - Focused on use of housing, cultural assimilation and acculturation - (생애구술을 통해 본 중국 할빈지역 조선족의 주거의 사용 - 주거의 사용과 생활문화의 동화 및 문화접변을 중심으로 -)

  • Hong, Hyung-Ock
    • Journal of Families and Better Life
    • /
    • v.28 no.6
    • /
    • pp.81-94
    • /
    • 2010
  • This qualitative research was designed to explore the use of housing among Korean Chinese people in Harbin, China. Focusing on the use which based on the epistemology of housing adjustment, this was particularly designed to examine its cultural assimilation and acculturation on the way of life course, it employed the in-depth interview on the oral history of 5 interviewees in their 60s and 70s, individualized interviews were conducted from May 28 to 31 in 2010. Key findings were summarized as follows; 1. The free market reform in China resulted in privatization that allowed respondents to become homeowners, and the ownership was viewed as part of family asset centered upon a sense of solidarity. 2. Although homeowners in multi-story houses were responsible to decorate interior spaces, the common features in using interior spaces were found: entrance had no thresholds; kitchen was small, lack of storage cabinets, tile-flooring; washers were installed inside bathroom; and newly built apartment didn't have proper space to store Korean fermented foods. It was observed that housing adaptation outweighed housing adjustment. Those who used to live in Chinese houses with indoor-wearing-shoes or Russian houses with indoor-wearing-slippers were receptive to the use of dining table and bed, and the community heating system discouraged the use of individual electric water heater because of high electricity cost. 3. In daily life, eating habit wasn't much changed to the Chinese style, meals were shared, dish sterilizer was popular, and Kimchi fridge wasn't used. Because of the influence of the Chinese culture, such Korean traditions as ancestral rites and bedroom allocation tradition faded away, but traditional family values remained unchanged. In conclusion, Korean Chinese people experience normative housing deficits and adaptation selectively incurred. It's implied that residential design meets the needs resulting from the dual culture in terms of cultural assimilation and acculturation.

A Study on the Characteristics of Groundwaters in Gyeongsan City (경산시 지하수의 수질특성에 관한 연구)

  • Song, Sung-Sook;Park, Byoung-Yoon;Lee, Bu-Yong
    • Journal of Environmental Science International
    • /
    • v.16 no.6
    • /
    • pp.677-682
    • /
    • 2007
  • This study was performed to provide the basic information on characteristics of groundwater pollution in Gyeongsan city. Forty two groundwater samples were collected, and pH, DO, COD, $NH_3-N,\;NO_3^--N$, T-N, $PO_4^{3-}-P$, Cl, Ca, Mg, hardness, evaporate residues and others were investigated. And, ANOVA analyses were carried out to reveal the differences in water pollution indicator values of by industry, commerce/residence and agriculture areas. The results were as follows. 1. The mean values of pH, DO, COD, $NH_3-N,\;NO_3^--N$, T-N, $PO_4^{3-}-P$, Cl, evaporate residues, Ca and hardness were 6.9, $7.9mg/\ell,\;0.4mg/\ell,\;2.44mg/\ell,\;2.73mg/\ell,\;6.06mg/\ell,\;0.82mg/\ell,\;32.72mg/\ell,\;381.67mg/\ell,\;41.53mg/\ell,\;177.17mg/\ell$, respectively. 2. As groundwater became deeper, the values of Cl, Ca, Mg, Na, hardness and evaporate residues remarkably increased, but those of COD, $NH_3^--N,\;NO_3^--N,\;NO_2^-N$, T-N decreased. 3. The values of COD, Cl, Ca, Mg, Na, hardness and evaporate residues were very high in industrial area, and those of $NH_3-N,\;NO_2^--N$, T-N were very high in commercial/residential area, and those of $NO_3^--N$ were a little high in agricultural area. 4. The correlations between depth and each value of Mg, Na, Fe, hardness and evaporate residues were highly positive, and those between DO and each value of Mg, Cu, Fe, hardness and evaporate residues were highly negative. 5. According to ANOVA analyses, the differences in three area groups (industry, commerce/residence and agriculture) on the values of $NH_3-N$, T-N, evaporate residues, hardness, Ca, Mg, K and Fe were significant at 1% level.