• Title/Summary/Keyword: Residential loads

Search Result 115, Processing Time 0.025 seconds

Lateral-resisting Structural Systems for Tall Modular Buildings (모듈러 건축물의 수평력 저항 구조시스템)

  • Lee, Chang-Hwan;Chung, Kwang-Ryang
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.79-88
    • /
    • 2016
  • Modular buildings are constructed by assembling modular units which are prefabricated in a factory and delivered to the site. However, due to a problem of noise between floors, concrete slab is usually poured at the top or bottom level of a modular unit in Korea. This greatly increases the weight of buildings, but designing vertical members of modular units to resist overall gravity loads is very inefficient. In this study, considering domestic building construction practices, feasible structural systems for tall modular buildings are proposed in which separate steel frames and reinforced concrete core walls are designed to resist gravity and lateral loads. To verify performance, a three-dimensional structural analysis has been performed with two types of prototype buildings, i.e., a residential building and a hotel. From the results, wind-induced lateral displacements and seismic story drifts are examined and compared with their limit values. Between the two kinds of buildings, the efficiency of the proposed system is also evaluated through a comparison of the weight of structural components. Finally, the effect of a floor diaphragm on the overall behavior is analyzed and discussed.

A Load Modeling to Utilize Power System Analysis Software (전력계통해석용 프로그램에 적용하기 위한 부하모델링)

  • 지평식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.96-101
    • /
    • 1999
  • Load model is very important to improve accuracy of stability analysis and load flow study in power systems. A power system bus is composed by various loads, and loads have different power consumption due to voltage/frequency changing. Thus the effect of voltage/frequency changing must he considered to load mxleling. In this research, ANN was used to construct component load moddel for more accurate load mxleling. Typical residential load was selected, and characteristics exrerimented on voltage/frequency changing. Acquired data used to construct the component ANN model, and aggregation method of component load model was presented based on component load model and composition rate. Furthennore, it's transfomlation method to the mathematical load model to he used at the traditional power system analysis soft wares was also presented.sented.

  • PDF

Comparison between the Egyptian and international codes based on seismic response of mid- to high-rise moment resisting framed buildings

  • Ahmed Ibrahim;Ibrahim El-Araby;Ahmed I. Saleh;Mohammed Shaaban
    • Structural Engineering and Mechanics
    • /
    • v.87 no.4
    • /
    • pp.347-361
    • /
    • 2023
  • This research aims to assess the behavior of reinforced concrete (RC) residential buildings when moment-resisting frames (MRFs) are used as the lateral resisting system. This investigation was conducted using MIDAS Gen v.19.0. Buildings with various plan footprints (Square, Rectangular, Circular, Triangular, and Plus-Shaped), and different heights (15 m, 30 m, 45 m, and 60 m) are investigated. The defined load cases, the equivalent static lateral load pattern, and the response spectrum function were defined as stated by the American Standard (ASCE 7-16), the 1997 Uniform Building Code (UBC97), the Egyptian Code for Loads (ECP-201), and the European Standard (EC8). Extensive comparisons of the results obtained by the different codes (including the story displacement, the story drift, and the base shear) were undertaken; to assess the response of moment-resisting multi-story framed buildings under lateral loads. The results revealed that, for all study cases under consideration, both ECP-201 and EC8 gave smaller base shear, displacement, and drift by one third to one fourth, around one fourth, around one fifth, respectively for both the ELF and RSA methods if compared to ASCE 7-16 and UBC97.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF

The Effects of Spot Pricing for the Change of the Electric Power Demand Based the Demand Elasticity (수요 탄력성에 따른 전력수요의 변화가 현물가격에 미치는 영향)

  • 김문영;백영식;송경빈
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.142-148
    • /
    • 2002
  • The variations of real time electric price in competitive electricity markets have influence on electric power demands of the consumers. Residential, commercial, and industrial consumers with different characteristics cause the different price elasticity of the demand due to changing the pattern of consumption. Therefore, this paper analyze the effects of spot pricing for the change of the electric power demand based on the demand elasticity of each loads in competitive electricity market.

A Study on the Load Characteristics of IH (Induction Heating) Cookers (IH조리기의 부하 특성에 관한 연구)

  • Hwang, Sung-Wook;Nah, Hwan-Seon;Park, Hyeon-Jeong;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.258-259
    • /
    • 2011
  • This paper shows the load characteristics of IH (Induction Heating) Cookers which are those of essential appliances for electrifying residential buildings in smart places. Load experiments are carried out in the same manner as like previous two studies. The results will be used to develop new load models for smart places including heat pump loads for analyzing changed power system environments by the smart grid.

  • PDF

A Method of Transient Stability Analysis Using ANN (신경회로망 부하모델을 이용한 과도안정도 해석기법)

  • Lee, J.P.;Lim, J.Y.;Kim, S.S.;Ji, P.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.329-331
    • /
    • 2006
  • Load models are important for improving the accuracy of stability analysis. Load characteristics are changed for voltage and frequency condition. In this research, ANN with LMBP learning rule is used to construct the load model. Characteristics of some residential loads are tested under various voltage and frequency conditions. Acquired data are used to construct load models by ANN. Constructed ANN load model are applied to transient stability analysis.

  • PDF

Design of tall residential buildings in Singapore for wind effects

  • Balendra, T.;Ma, Z.;Tan, C.L.
    • Wind and Structures
    • /
    • v.6 no.3
    • /
    • pp.221-248
    • /
    • 2003
  • The design of high-rise building is often influenced by wind-induced motions such as accelerations and lateral deflections. Consequently, the building's structural stiffness and dynamic (vibration periods and damping) properties become important parameters in the determination of such motions. The approximate methods and empirical expressions used to quantify these parameters at the design phase tend to yield values significantly different from each other. In view of this, there is a need to examine how actual buildings in the field respond to dynamic wind loading in order to ascertain a more realistic model for the dynamic behavior of buildings. This paper describes the findings from full-scale measurements of the wind-induced response of typical high-rise buildings in Singapore, and recommends an empirical forecast model for periods of vibration of typical buildings in Singapore, an appropriate computer model for determining the periods of vibration, and appropriate expressions which relate the wind speed to accelerations in buildings based on wind tunnel force balance model test and field results.

Analysis on Monitoring Results of Korean Soil Monitoring Network (토양측정망 운영 결과 분석 연구)

  • Jeong, Seung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.2
    • /
    • pp.18-23
    • /
    • 2010
  • Usability of soil quality monitoring network for ascertaining soil quality changes was evaluated by analysing soil quality monitoring results. Tolerance limits of soil quality monitoring results from 1997 to 2007 were calculated and compared with Korean soil quality standards. This study determined that soil quality was changed if the upper 95% tolerance limit value was greater than the soil quality standard. Fluoride most frequently exceeded the soil quality standard and nickel, zinc, arsenic, copper, lead and cadmium were followed. Analysis on land use showed that tolerance limits of industrial land use most frequently exceeded the soil quality standards and residential, road and various land uses then frequently exceeded. Tolerance limits of land uses expecting high contaminant loads frequently exceeded the soil quality standards. This fact imply that the soil quality monitoring network generates reasonable data to represent change in Korean soil quality. This study also suggested that representative sampling from well identified points should be done to improve data reliability and accurately ascertain soil quality changes.

Analytical study on Reinforced Concrete Deep Beams with Opening (철근콘크리트 유공 깊은 보에 대한 해석적 연구)

  • 이석주;이종권;이병해
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.587-592
    • /
    • 2000
  • As the residential spaces become high-rised and high-density, Multi-story buildings were constructed with transfer girders, Deep beams, wall foundations, floor diaphragms an shear walls which may have column offsets. Especially, In the analysis and design of Multi-story buildings, the lateral loads must be taken into account. But, there have been no appropriate theory and national design code for predicting ultimate shear strength of reinforced concrete Deep beams with web opening. Only empirical and semi-empirical formulas for predicting their ultimate load bearing capacities due to the complexities of the structural non-linearity and material heterogeneity. So this study analyze tow-dimensional finite element model that represents exactly the behavior of real structures with SBETA which are general nonlinear finite element analysis program, and compare the results with that from the real reinforced Concrete Deep beams with web opening tests. From the comparison, and parametric study, The Study presents the elementary data of the earthquake resistance for the reinforced concrete Deep beams with web opening.

  • PDF