• Title/Summary/Keyword: Residential combustion

Search Result 47, Processing Time 0.025 seconds

Study on the Heating Performance Characteristics of a Heat Pump System Utilizing Air and Waste Heat Source for Electric Vehicles (이중열원을 이용한 전기자동차용 히트펌프 시스템의 난방 성능 특성에 관한 연구)

  • Woo, Hyoung Suk;Ahn, Jae Hwan;Oh, Myoung Su;Kang, Hoon;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.4
    • /
    • pp.180-186
    • /
    • 2013
  • An electric vehicle is an environment-friendly automobile which does not emit any tailpipe pollutant. In a conventional vehicle with an internal combustion engine, the internal cabin of the vehicle is usually heated using waste heat from the engine. However, for an electric vehicle, an alternative solution for heating is required because it does not have a combustion engine. Recently, a heat pump system which is widely used for residential heating due to its higher efficiency has been studied for its use as a heating system in electric vehicles. In this study, a heat pump system utilizing air source and waste heat source from electric devices was investigated experimentally. The performance of the heat pump system was measured by varying the mass flow rate ratio. The experimental results show that the heating capacity and COP in the dual heat source heat pump were increased by 20.9% and 8.6%, respectively, from those of the air-source heat pump.

HCCI Combustion Engines with Ultra Low CO2 and NOx Emissions and New Catalytic Emission Control Technology (CO2/NOx 초저배출형 HCCI 엔진 연소기술과 신촉매제어기술)

  • Kim, Moon-Hyeon
    • Journal of Environmental Science International
    • /
    • v.17 no.12
    • /
    • pp.1413-1419
    • /
    • 2008
  • The Kyoto Protocol, that had been in force from February 16, 2005, requires significant reduction in $CO_2$ emissions for all anthropogenic sources containing transportation, industrial, commercial, and residential fields, etc, and automotive emission standards for air pollutants such as particulate matter (PM) and nitrogen oxides $(NO_x)$ become more and more tight for improving ambient air quality. This paper has briefly reviewed homogeneous charge compression ignition (HCCI) combustion technology offering dramatic reduction in $CO_2,\;NO_x$ and PM emissions, compared to conventional gasoline and diesel engine vehicles, in an effort of automotive industries and their related academic activities to comply with future fuel economy legislation, e.g., $CO_2$ emission standards and corporate average fuel economy (CAFE) in the respective European Union (EU) and United States of America (USA), and to meet very stringent future automotive emission standards, e.g., Tier 2 program in USA and EURO V in EU. In addition, major challenges to the widespread use of HCCI engines in road applications are discussed in aspects of new catalytic emissions controls to remove high CO and unburned hydrocarbons from such engine-equipped vehicles.

Indoor air quality and ventilation requirement in residential buildings: A case study of Tehran, Iran

  • Ataei, Abtin;Nowrouzi, Ali;Choi, Jun-Ki
    • Advances in environmental research
    • /
    • v.4 no.3
    • /
    • pp.143-153
    • /
    • 2015
  • The ventilation system is a key device to ensure both healthful indoor air quality (IAQ) and thermal comfort in buildings. The ventilation system should make the IAQ meet the standards such as ASHRAE 62. This study deals with a new approach to modeling the ventilation and IAQ requirement in residential buildings. In that approach, Elite software is used to calculate the air supply volume, and CONTAM model as a multi-zone and contaminant dispersal model is employed to estimate the contaminants' concentrations. Amongst various contaminants existing in the residential buildings, two main contaminates of carbon dioxide ($CO_2$) and carbon monoxide (CO) were considered. CO and $CO_2$ are generated mainly from combustion sources such as gas cooking and heating oven. In addition to the mentioned sources, $CO_2$ is generated from occupants' respirations. To show how that approach works, a sample house with the area of $80m^2$ located in Tehran was considered as an illustrative case study. The results showed that $CO_2$ concentration in the winter was higher than the acceptable level. Therefore, the air change rate (ACH) of 4.2 was required to lower the $CO_2$ concentration below the air quality threshold in the living room, and in the bedrooms, the rate of ventilation volume should be 11.2 ACH.

The $CH_4$and $C_4$$H_{10}$ Sensitivity Measurement and Voltage Variation Using Catalytic Combustion Type Gas Sensor (접촉연소식 센서를 이용한 $CH_4$$C_4$$H_{10}$ 감도 측정 및 전압변화)

  • 윤헌주;신종열;홍진웅
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.44-48
    • /
    • 2001
  • In this study, we analyzed the $CH_4$and $C_4$$H_{10}$ sensitivity measurement and voltage variation using catalytic type gas sensor characteristics in catalytic combustion type gas detecter sensors. Gas detector shall operate as intended when exposed for 24 hours to air having a relative humidity of 65 percent at a temperature of $20^{\circ}c$ and humidity of 85 percent at a temperature of $40^{\circ}c$. The gas detecter sensors are to be subjected to operation for 210 days in an area that has been determined to be equivalent to a typical residential atmosphere with an air velocity of 50 cm/sec. The source of energy for a gas detector sensors employing a supplementary basic circuit is energized from a seperate source of supply direct applied voltage 2.1V, 2.2V, 2.3V. As a result, it was confirmed that the relative humidity and temperature by regression each analysis, compared to the isobutane characteristic graph and methane characteristic graph by a relative humidity of 65% and 85% at a temperature($20^{\circ}c$, $40^{\circ}c$) show a similar linear pattern on the whore.

  • PDF

Experimental Study on Particle Temperature and CO/CO2 Emission Characteristics of Pulverized Coal Combustion Condition According to Coal Types in Blast Furnace (고로 내 미분탄 연소조건에서 탄종에 따른 입자온도와 CO/CO2 배출 특성에 관한 연구)

  • Cho, Young Jae;Kim, Jin Ho;Kim, Ryang Gyun;Kim, Gyu Bo;Jeon, Chung Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.10
    • /
    • pp.807-815
    • /
    • 2014
  • This study was performed using a laminar flow reactor that could replicate the combustion environment of pulverized coal in a blast furnace. Since a pulverized coal injection system was developed for iron making, the combustion characteristics of pulverized coal have been important in the iron and steel industry. The flame structure, particle temperature, and exhaust gas were investigated for different types of coal. The results of this study demonstrated that the combustion characteristics of coal are influenced by several properties of individual coals. In particular, the CO emission and volatile matter content of individual coals were found to have a strong influence on their combustion characteristics. Thus, this study found the properties of the coals to be significant and focused on the particle temperature and CO and $CO_2$ emissions.

Estimation of major sources of Polycyclic Aromatic Hydrocarbons (PAHs) in Seoul by using the receptor models (수용 모델을 이용한 서울시의 PAHs 주요 배출원 추정)

  • Han, Sang Hee;Lee, Ji Yi;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.12 no.2
    • /
    • pp.27-36
    • /
    • 2016
  • The PMF result was compared with the result from the Chemical Mass Balance (CMB) modelling (Lee and Kim, 2007) to estimate major source of PAHs observed at Seoul from August 2002 to December 2003. Five major sources were estimated from PMF and CMB modellings respectively. Among them three major sources (coal combustion for residential, coke oven and biomass burning) were identified at both models.

Experimental Study of Condensation Heat Transfer in Pre-heating Exchanger to the Type of Hydrophilic Surface Treatment (친수 표면처리 종류에 따른 공기 예열 열교환기의 응축 열전달 실험적 연구)

  • Seok, Sungchul;Chung, Tae-Yong;Chin, Donghoon;Hwang, Seungsik;Choi, Gyuhong;Park, Jaewon
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.237-238
    • /
    • 2012
  • Recently, an energy-saving due to the energy utilisation efficiency enhancement is important. In order to improve the heat efficiency of the general residential boiler, We performed an experiment of condensation heat transfer to air pre-heat exchanger adhered to the condensing boiler. In this research, We analyze the heat transfer performance through the hydrophilic surface treatment(plasma, etching). The results of the research, On plasma and etching treated surface, Overall heat transfer coefficient is displayed the tendency to increase.

  • PDF

Development of Ventilator without Power using Air Flow (공기흐름을 이용한 무동력 환풍장치 개발)

  • Kim, Bum-Suk;Kwon, Taek-Joo;Jeong, Ji-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.26-31
    • /
    • 2016
  • The studies on the efficient ventilator to reduce fire and save energy have been proceeded actively. The purpose of this paper is to design a ventilator used in residential wood stove. The ventilator consists of rotation and support part, and it is operated by natural wind without power. The shape of rotation part of the ventilator is like airfoil to reinforce pressure drop. We designed direction controller for the rotation part to track the direction of wind continuously. The rotation and support part have point-contact each other to minimize a friction. We verify the properties of the proposed ventilator though simulation and experiment. The results show the proposed ventilator can exhaust safely combustion gas of the stove more than other ventilator.

A Study on the Cone Calorimeter and Furniture Calorimeter using Residential Combustible Combustion Characteristics (Cone Calorimeter와 Furniture Calorimeter를 활용한 주거시설의 대표적 가연물 연소 특성)

  • Kim, Dong-Eun;Kim, Bong-Chan;Lee, Jae-Won;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.193-196
    • /
    • 2011
  • 본 연구는 주거시설의 대표적인 가연물을 고정가연물과 적재가연물로 구분하여 가연물의 연소특성을 실험결과에 대한 연구이다. 고정가연물은 7종에 대하여 Cone Calorimeter로 적재가연물은 2종 Furniture Calorimeter로 실험을 실시하였다. 고정가연물의 경우 접착성분을 지니고 있는 시트지의 경우가 HRR등이 높게 측정되었으며, 적재가연물의 경우 섬유성분과 플라스틱으로 구성되어 있는 의자가 높게 측정되는 것을 알 수 있었다.

  • PDF

Size Distribution Characteristics of Particulate Matter Emitted from Cooking (조리과정에서 생성된 미세먼지의 크기분포 특성)

  • Joo, Sang-Woo;Ji, Jun-Ho
    • Particle and aerosol research
    • /
    • v.16 no.1
    • /
    • pp.9-17
    • /
    • 2020
  • The characteristics of particulate matter made from daily cooking at a Korean residential apartment house with three dwellers had been investigated for about 3 months. All data were recorded by an optical particle counter every minute at the kitchen. Types of cooking such as boiling, frying, and grilling that performed in the house were listed. Boiling only was used in 32% cases among total 234 meals. Frying and grilling were 14% and 11%, respectively. From an initial indoor particulate matter smaller than 10 ㎛ in diameter, the increases due to cooking are reported by size. In case of boiling, PM at 1-10 ㎛ size and under 1 ㎛ size little increased. Normally, particles from oil or combustion in a process of frying or grilling increased indoor PM. In a case of grilling, particle mass concentration in a region of 1-10 ㎛ in diameter increased as much as 295 ㎍/㎥. Mass concentration of particles smaller than 1 ㎛ increased as much as 33 ㎍/㎥.