• Title/Summary/Keyword: Residential Apartment

Search Result 693, Processing Time 0.04 seconds

The Residential Satisfaction of Residents in the High-rise Mixed-use Apartment (초고층 주상복합아파트 거주자의 주거만족도)

  • Lee, Soo-Hyun;Kang, Soon-Joo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.145-149
    • /
    • 2003
  • This study is to investigate residents' living satisfaction with high-rise mixed-use apartment complexes built in the structures of the reinforced concrete constructing and the steel framed reinforced concrete construction. The results of this study were obtained as follows: 1. Residents expressed below average satisfaction (below 3.0) with the common-area landscape and environmentally-friendly factors, children's playground and its facilities, community service for residents' by the management offices and the plan of utility. 2.According to the satisfaction of sound environment, residents of SRC group expressed above average satisfaction; it can be concluded that problems of causing noise around the residential area of the SRC and S groups were well solved in this study. However, satisfaction with the freshness of indoor air, humidity, and smell in the living quarters was rated low by the residents of SRC group. 3. High-rise mixed-use apartment complexes should accomodate families's life cycle, design an environmentally-friendly resting place in harmony with city life, and provide various communal programs for residents.

  • PDF

Family Life Issues of Middle Aged Apartment-Residents in Seoul : Focused on Residential Environment (서울시 아파트 거주 중년기 가정이 생활 실태와 문제 (I) : 주생활을 중심으로)

  • 임정빈
    • Journal of the Korean Home Economics Association
    • /
    • v.33 no.3
    • /
    • pp.279-289
    • /
    • 1995
  • The purpose of this research was to analyze the residential environment of the middle aged apartment-residents in seoul as a part of collaborative study on family life issues of them. the sampling area was divided tin to kangnam and Kangbuk according to the residential location and upper middle group and lower middle group according to the size of the apartment unit. The data were collected from 307 fulltime housewives with at least one child in a junior or senior high school. Housing circumstance was generally adequate to the middle aged apartment-residents in seoul. the findings supported the family housing adjustment theory well. however, the results showed that the housing policies should reflect to the various housing demands on the structure type, size, and tenure of dwelling, unaffordability of low income renters, and stabilizing the housing price as well as expanding the housing mortgages for the middle aged to prepare for one's own aging.

  • PDF

Analysis of Microclimate in Apartment Complex by Age (시대별 아파트 단지의 미기후 분석)

  • Kim, Chul-Hee;Jung, Eung-Ho;Kim, Dae-Wuk;Cha, Jae-Gyu
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.104-108
    • /
    • 2009
  • Rapid urbanization resulted in expansion of urban area and increase of population bringing deepened housing shortage. Supply-oriented housing policy made apartment a representative residential space in Korea in spite of the short history of apartment. This study analyzed the shape and arrangement of main building by year and the microclimate in the complex depending on the number of floors. The purpose of this study was to present the basic data in developing apartment complex to solve problems like the stagnation of pollution source and the rise of temperature due to the declined ventilation in apartment complex, and the worsened urban heat island phenomenon due to the impeded flow of wind. This study rearranged the shape and arrangement of main building by year and the tendency of the number of floors by year in the process of change, by generalizing the process of change of apartment complex, a representative modern residential space through preliminary research. Based on it, 8 object lot by age was selected and simulated by using Envi-met. Simulation identified that the change of apartment complex takes place having a positive effect on microclimate in the apartment complex and the microclimate in the apartment complex is influenced a lot by the shape of complex. If in future apartment complex plan, a systematic legal criteria of design is made about the shape and arrangement of main building, it might have a positive effect on the improvement of microclimate in the apartment complex, a representative residential space in Korea.

  • PDF

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택내 다분기챔버형 환기시스템 적용을 통한 풍량분배 개선효과에 관한 연구)

  • Kim, Sung-Soo;Son, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.545-552
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. And TAB process is applied to control the designed air volume with adjusting volume dampers and/or supply diffusers after fully installing the ventilation system. This process has been resulted increasing the initial cost for the residential ventilation system because of man-hour and accessories such as volume control damper or diffuser. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system.

Waterproofing and Root Barrier Construction Design for Artificial Green Roof System of Residential Apartment Underground Parking Lots (공동주택 지하주차장 상부 인공지반녹화층 방수 및 방근 설계 방안)

  • Lee, Jung-Hun;Kim, Bum-Soo;Song, Je-Young;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.337-338
    • /
    • 2018
  • In recent years, residential apartment building parking lots are built in underground spaces, and with conjunction to improve the environment of the urban area, artificial greeen roof systems are installed on the upper slabs. However, early plant growth are resulting in root penetration into concrete cracks and in turn into the waterproofing membranes, leading to degradation and damaging of the waterproofing system and structural durability. This issue highlights a problem of conventional maintenance system of concrete structures, and proposals for amendments follow. In this study, a waterproofing and root barrier construction design for the upper slabs of residential building underground parking lots is proposed, and motioned to be added into future construction specifications.

  • PDF

A Study on Sunshine Environment with Different Distance between Buildings (인동간격에 따른 일조환경에 대한 연구)

  • 최용석;최지혜;김용식
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • Apartment design in residential Area is restricted by building distance limit code. Building distance limit decreases gradually to the 0.8H(height), and residential area has 250% site area ratio by building code, so site using has become efficient. In this study, examine the relationship between present building distance limit and right of daylighting environment by computer simulation. As well, high-rise residential officetel and multipurpose residential building becomes increase in commercial non-residential area. In the domestic, residential type multipurpose building made at the business area or central business area has 400∼800% site area ratio by building code. However, at a dweller's point of view, there are much lacks of environmental consideration to provide suitable daylighting environment. And, POE: Post Occupancy Evaluation is not completed yet. In this study, however, progress architectural environment prediction, basis by right of daylighting, and examine the possibility of daylighting by architectural distance limit code in residental area and by high-rise, high-density residential building in non-residental downtown area.

Evaluation Methodology of Solar Rights Using Autodesk VIZ for Apartment Buildings (Autodesk VIZ를 이용한 공동주택의 일조권평가방법에 관한 연구)

  • Moon, Ki Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.35-42
    • /
    • 2006
  • The apartment buildings now covers more than 50% of the total residential types in Korea and the urban residential area becomes increasingly congested with newly constructed high-rise apartment buildings. Judicial precedents require, for securing the solar rights in the residential area, that the consecutive sunshine duration should be at least two hours from 9:00 to 15:00 or the accumulative sunshine duration should be at least four hours from 8:00 to 16:00 as of the winter solstice. Disputes are increasing, however, on infringed solar rights and view rights for the neighboring structures as cases occur where the requirement cannot be satisfied in congested residential areas. The sunshine duration scan be assessed by measuring it on the site of the dispute, but it is impracticable to actually measure it for every case on the winter solstice, only one day out of the whole year. At a trial, therefore, 3D computer simulation is used to calculate the sunshine duration and determine the extent of infringement for submission of the evaluation to be used as the basis of the judgment. The simulation, however, may have an error in its result up to the program characteristics and the accuracy of the input data such as the structure shape and height, the distance between structures, and the ground level. This study, therefore, used a self-developed VIEW program with Autodesk VIZ 2006 to provide a simulation method for solar access evaluation, and verified its efficacy by comparing the results with the actual measurements.

Evaluation of Escape Safety Depending on the Number of Users of Residential Convenience Facilities in the Apartment Complex and the Kind of Elevators

  • Cho, Seong-Suk;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.376-384
    • /
    • 2021
  • This study wants to provide basic data on effective escape safety plans when residents of apartment complex use residential convenience facilities. The findings of the analysis are as follows. First, when this study applied the actual number of users (No=54) of those facilities, the existence of elevator for escape reduced the escape time by 189.0 seconds. Second, when the number of users was calculated on the standard of the number of people who can be accommodated for performance based design (No=316), the existence of the elevator for escape reduced the escape time by 173.5 seconds. Finally, when the number of users was calculated on the standard of installing fire-fighting facilities (No=122), the existence of the elevator for escape reduced the escape time by 159.2 seconds. As a result, it was found that elevator for escape reduces the escape time from fire. Accordingly, it is necessary to revise the construction law to make it obligatory for residential convenience facilities to be equipped with elevator for escape. Currently, apartment buildings lower than 30 stories have either elevator for passengers or elevator for escape. Thus, in future studies, it is necessary to compare escape times in fire depending on the kinds of elevator, and identify the usefulness of elevator for escape.

The Plan for Apartment Unit containing the Space Organization, Residential Space and Housing Design Elements of Han-Ok (한옥의 공간구성과 주거공간 및 주택의장요소를 담은 아파트 단위세대 계획안)

  • Kang, Hyo-Jeong
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.250-257
    • /
    • 2013
  • This study focuses on the fact that the Korean traditional design application appears as one of the trends for a planning technique to express an apartment as a healthy, clean and environment-friendly dwelling recently. Focusing on this, this study tries to apply the characteristic of Han-Ok to an apartment unit plan more compositively beyond the fragmentary design application of existing preceding researches. To do this, the space organization, residential space and housing design elements of Han-Ok are deducted through preceding researches and case studies and proposes a plan by applying this to the apartment plan with a floor plan of about $132m^2$(40 pyeong). The apartment unit plan containing the characteristic of Han-Ok proposed in this study is planned based on the floor plan of about $132m^2$(40 pyeong) which is distributed the most in the city of Seoul. It has an advantage in terms that it can be individually applied not only when a construction firm progresses business anew carrying the banner for a Korean-style apartment but also an existing residents can apply through remodelling. Meanwhile, it has a limit that the diversified space sense and the advantage of an airy Han-Ok cannot be applied to many parts of the design due to the characteristic of an apartment of diverse height change. If a measure to secure constructability and economic feasibility while reflecting diverse differences of floor-level of an apartment can be prepared in follow-up researches, much more various advantages of Han-Ok can be put into the apartment design.

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택 적용을 위한 다분기챔버 환기 시스템의 성능평가에 관한 연구)

  • Kim, Sung Soo;Sohn, Jang yeul
    • KIEAE Journal
    • /
    • v.9 no.4
    • /
    • pp.17-22
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system. The experiments were designed to simulate apartment of $84m^2$ and established multidrop chamber duct and general duct on the ceiling of the apartment. Distribution performance of air supply rate were evaluated in this experiments. As a result, distribution performance of air supply rate in the general duct is different from designed air supply rate by about 35% ~ 50% and about 10% in the multidrop chamber system. In additional the sound insulation performance of the multidrop chamber system decreased about 20% compared with general duct system. Therefore, the multidrop chamber system is considered to satisfy proper air supply rate of each room and to improve the sound insulation performance in apartment Houses.