• Title/Summary/Keyword: Required pressure

Search Result 2,298, Processing Time 0.026 seconds

Operational Properties and Microbial Inactivation Performance of Dielectric Barrier Discharge Plasma Treatment System (유전체장벽방전 플라즈마 장치의 조작특성과 살균력)

  • Mok, Chulkyoon;Lee, Taehoon
    • Food Engineering Progress
    • /
    • v.15 no.4
    • /
    • pp.398-403
    • /
    • 2011
  • A dielectric barrier discharge plasma (DBDP) treatment system was fabricated and the optimum operating conditions for the plasma generation were determined in order to explore the potential of cold plasma as a non-thermal proessing technology. The microbial inactivation performance of the system was also evaluated against Staphyloocus aureus. The system consisted of power supply, transformer, electrode assembly and sample treatment plate. The input power was 220 V single phase AC and amplified to 10.0-50.0 kV on a transformer. A pulsed sine wave of frequency 10.0-50.0 kHz was introduced to the electrode embedded in ceramic as a dielectric barrier material in order to generate plasma at atmospheric pressure. Higher currents and consequently greater power were required for the plasma generation as the frequencies increased. A homogeneous and stable plasma was generated at currents of 1.0-2.0, and frequencies of 32.0-35.3 kHz. The optimum electrode-gaps for the plasma generation were 1.85 mm without loaded samples. More power was consumed as the electrode-gaps increased. The practically optimum electrode- gap was, however, 2.65 mm when samples were treated on slide-glasses for microbial inactivation. The maximum temperature increase after 10 min treatment was less than 20$^{\circ}C$, indicating no microbial inactivation effect by heat and thereby insuring a non-thermal method. The DBDP inactivation effect against Staphyloocus aureus increased linearly with treatment time up to 5 min, but plateaued afterward. More than 5 log reduction was achieved by 10 min treatment at 1.25 A.

A Study on the Identification of Hazardous Factors and Prevention of Accident in Old Boilers (노후보일러 유해인자 발굴 및 사고예방에 관한 연구)

  • Sa, Min-Hyung;Woo, In-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.1-9
    • /
    • 2019
  • Large-scale industrial boilers operating at high temperature and high pressure, have a large amount of water, and a large amount of energy is released at the time of explosion. Currently, most industrial boilers use gas fuel such as LNG and LPG, etc. and fuel exists in the same space as equipment, so there is a high possibility of secondary damage such as fire or explosion in the event of a boiler accident. Both special care and management are required to operate the very dangerous equipment that causes casualty 2.51 per accident. For boilers of a certain size or more, the Korea Energy Agency conducts inspections in accordance with the Energy Usage Rationalization Act, KS, and public notice of the Ministry of Industry, Trade and Resources. In this research, based on the results of the inspection, the hazard factorss are configured, and a questionnaire is conducted to the inspector, the equipment manager, the maintenance person, and the person in charge of the manufacturer. We analyzed the results by using AHP (Analytic Hierarchy Process). As a result of analysis, generally recognized hazard factorss are not good management, measurement failure, specification failure, water leak, leak analysis, but connection, welding, scale, and corrosion, etc. are relatively less important. It is judged that the adverse factors that are recognized to be highly important among all groups and careers are already well managed, but less important and adverse factors should be well managed to ensure that the safe usage of the boiler.

Study on about Emotional Labor Experience of Social Workers through Thematic Analysis : Focusing on Social Workers in P City Case (주제분석을 통한 사회복지 종사자의 감정노동 경험 연구: P시 사례를 중심으로)

  • Suh, Borahm
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.3
    • /
    • pp.31-47
    • /
    • 2019
  • This study analyzes the emotional labor experiences of 8 social workers in social welfare facilities and public institutions by thematic analysis method with interveiws with them. Six categories and Twenty two themes concerning the emotional labor experience were derived from the analysis. Six categories are as follows: 'work life as a target for anger', 'unsafe workplace', 'emotional labor that ruins life', 'overcoming hurt emotion', and 'living with emotional labor'. Social workers are constantly required to perform emotional labor providing services to clients in the field of practice, and they also suffer verbal abuse from clients. Social workers feel the pressure of work in the environment that does not tolerate mistakes and they must keep their safety on their own. In these cases, emotional labor has effects on the physical and mental health of workers. The problem of emotional labor is difficult to solve and there might not be no choice but to endure. This study suggests practical and policy measures for social workers based on the results of the analysis. Policy suggestions are as follows: safety assurance for social workers, establishment of base facilities for employee support, human rights education for employees, preparation of super vision system, and the provision of a mental health care system.

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

The Study on Filling Factor of Radiation Shielding Lead-free Sheet Via Screen Printing Method (스크린 프린팅 공법을 통한 방사선 무연 차폐 시트에 관한 연구)

  • Kang, Sang-Sik;Jeong, Ah-Rim;Lee, Su-Min;Yang, Seung-Woo;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.713-718
    • /
    • 2018
  • In many previous studies, monte carlo simulation is used to produce lead-free shielding sheet, and the possibility of radiation shielding capability and weight reduction is presented. But it is difficult to simulation for binder and micro-pores because of In fact it does not provide sufficient information necessary for the commercialization process. Therefore, in this paper, the results of radiation shielding capability corresponding to filling factor was presented by using the screen printing method to provide information on gel-paste required for the commercialization process. In this study, the geometric setup for evaluate of radiation shielding ability was designed to comply with IEC 61331-1:2014 and KS A 4025. In addition, radiation irradiation conditions were 100 kVp filtered with 2.0 mmAl total filtration was applied according to KS A 4021 standard. In this study, Pb $1270{\mu}m$, $BaSO_4$ $3035{\mu}m$, $Bi_2O_3$ $1849{\mu}m$ and $WO_3$ $2631{\mu}m$ were analyzed based on ten value layer. Additionally, the filling factor was analyzed as $BaSO_4$ 38.6%, $Bi_2O_3$ 27.1%, $WO_3$ 30.15%. However, in the case of applying low-temperature high-pressure molding in the future, it is expected that the radiation shielding capability can be sufficiently improved by reducing the porosity while increasing the filling factor.

A Study on The Thickness Shrinkage of Injection Molded Parts with The Variation of Injection Mold Core and Molding Materials (사출금형코어 및 성형수지 변화에 따른 두께 방향 수축률에 관한 연구)

  • Shin, Sung-Hyun;Jeong, Eui-Chul;Kim, Mi-Ae;Chae, Bo-Hye;Son, Jung-Eon;Kim, Sang-Yoon;Yoon, Kyung-Hwan;Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.17-21
    • /
    • 2019
  • In this study, selective laser sintered 3D printing mold core and metal core were used to investigate the difference of the thickness shrinkage from the gate of the injection molded part at a constant interval. SLS 3D printing mold core was made of nylon-based PA2200 powder and the metal core was manufactured by conventional machining method. As the PA2200 powder material has low strength, thermal conductivity and high specific heat characteristics compared with metal, molding conditions were set with the consideration of molten temperature and injection pressure. Crystalline resin(PP) and amorphous resin(PS) with low melting temperature and viscosity were selected for the injection molding experiment. Cooling time for processing condition was selected by checking the temperature change of the cores with a cavity temperature sensor. The cooling time of the 3D printing core was required a longer time than that of the metal core. The thickness shrinkage of the molded part compared to the core depth was measured from the gate by a constant interval. It was shown that the thickness shrinkage of the 3D printing core was 2.02 ~ 4.34% larger than that of metal core. In additions, in the case of metal core, thickness shrinkage was increased with distance from the gate, on the contrary, in the case of polymer core showed reversed aspect.

Development of a new system for measurement of total effluent load of water quality

  • Keiji, Takase;Akira, Ogura
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.221-221
    • /
    • 2015
  • Sustainable use of water resource and conservation of water quality are essential problems in the world. Especially, problems of water quality are serious one for human health as well as ecological system of all creatures on the earth. Recently, the importance of total effluent load as well as the concentrations of pollutant materials has been recognized not only for the conservation of water quality but also for sustainable water use in watersheds. However, the measurement or estimation of total effluent load from non-point source area such as farm lands or forests may be more difficult because both of concentration and discharge of the water are greatly changed depending on various factors especially metrological conditions such as rainfall, while the measurement from a point source area may be easy because the concentration of pollutant materials and amount of discharge water are relatively steady. Therefore, the total effluent load from a non-point source is often estimated by statistical relationships between concentration and discharge, which is called as L-Q equation. However, a lot of work and time are required to collect and analyze water samples and to get the accurate relationship or regressive equation. So, we proposed a new system for direct measurement of total effluent load of water quality from non-point source areas to solve the problem. In this system, the overflow depth at a hydraulic weir is measured with a pressure gage every hourly interval to calculate the amount of hourly discharge at first. Then, the operating time of a small electric pump to collect an amount of water which is proportional to the discharge is calculated to intake the water into a storage tank. The stored water is taken out a few days later in a case of storm event or several weeks later in a case of non-rainfall event and the concentrations of water quality such as total nitrogen and phosphorous are analyzed in a laboratory. Finally, total load of the water quality can be calculated by multiplying the concentration by the total volume of discharge. The system was installed in a small experimental forestry watershed to check the performance and know the total load of water quality from the forest. It was found that the system to collect a proportional amount of water to actual discharge operated perfectly and a total load of water quality was analyzed accurately. As the result, it was expected that the system will be very available to know the total load from a non-point source area.

  • PDF

A Management Plan of the Resources for Emergency Medical Facility at Disaster Site (재난현장 응급의료 시설자원 관리방안)

  • Song, Youngsub;Suh, Sangwook;Yoon, Yousang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.3
    • /
    • pp.46-53
    • /
    • 2019
  • Recently, the need for emergency medical facilities is increasing due to a large-scale disaster. The Ministry of the Interior and Safety has completed the development of Disaster Resource Sharing System (DRSS). In this system, only air tent and negative pressure tent, which are classified and managed as equipment are resources related to emergency medical facility at disaster site. However, the characteristics of resources for the facility such as the time of input, a period of stay, transportation, and installation methods were not reflected. So, The purpose of this study is to propose improvements of management of resources for emergency medical facility at disaster site, that classified to materials and equipment in DRSS. This study analyzed the state of resources for facilities and the attributes of resources based on literature and disaster medical consultation of mobile hospitals. The resources for emergency medical facility are required to be linked to medical support resources and reflected in the DRSS, since emergency medical facility resources at the disaster site should be managed through a combination of medical resources classified as equipment. And future research on installation of emergency medical facilities plan considering the cost of the disaster management resources should be carried out.

A Study on the Influencing Factors of High Risk Drinking by Gender in Single Adult Households (성인 1인 가구의 성별에 따른 고위험 음주 영향요인에 관한 연구)

  • Lee, Jeong Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.321-331
    • /
    • 2021
  • This study sought to analyze factors influencing high-risk drinking in single-person households. For this, data from the 2018 community health survey were used. Subjects were 32,389 adults above the age of 19 in single-person households. For the data analysis, high-risk drinking groups were extracted according to the high-risk drinking rate index of the survey to arrive at influencing factors and differences in health-related and sociodemographic characteristics. The IBM SPSS 25.0 software was used for analysis and a complex sampling design was applied. The results showed that the high-risk drinking rate of Korea's single-person households was 15.0% (male: 25.8%, female: 5.8%) and age, education under high school level, service-industry employees, smokers, people with depression, high blood pressure, and irregular breakfast eaters appeared as common elements for both genders. Stress appeared to only affect males while being diabetic only affected females. High-risk drinking was higher for males in their 30~40s and women in their 20~30s. The younger generation showed the highest numbers in high-risk drinking and factors like stress or depression appeared to be influencing factors for high-risk drinking. Hence, mental health programs along with customized health policies through health forms and lifestyle changes will be required to lower the high-risk drinking rates of single-person households.

Synthesis and Characterization of Interfacial Properties of Sorbitan Laurate Surfactant (Sorbitan Laurate 계면활성제 합성 및 계면 특성에 관한 연구)

  • Lee, Seul;Kim, ByeongJo;Lee, JongGi;Lim, JongChoo
    • Applied Chemistry for Engineering
    • /
    • v.22 no.1
    • /
    • pp.37-44
    • /
    • 2011
  • The critical micelle concentration (CMC) of sorbitan laurate SP 20 surfactant in this paper was near $7.216{\times}10^{-4}mol/L$ and the surface tension at CMC was about 26.0 mN/m, which showed higher CMC and lower surface tension than those of octylphenol ethoxylate octylphenol ethoxylate (OPE) 10 surfactant. Dynamic surface tension measurement using a maximum bubble pressure tensiometer showed that the adsorption rate at the interface between air and surfactant solution was found to be slower with SP 20 surfactant, presumably due to a low mobility of SP 20 surfactant monomer. The contact angle of SP 20 surfactant solution was observed to decrease with an increase in surfactant concentration and showed a larger value than that of OPE 10 surfactant solution. Half-life time for foams generated with 1 wt% surfactant solution was also larger with SP 20 surfactant, which indicated higher foam stability with SP 20 surfactant. Dynamic behavior study reveals that the solubilization of n-decane oil was much lower with SP 20, which is in good agreement with experimental results of foam stability, contact angle and CMC. Dynamic interfacial tension measurement by a spinning drop tensiometer shows that interfacial tensions at equilibrium condition in both systems were almost the same but the time required to reach equilibrium was longer with SP 20.