• 제목/요약/키워드: Replica techniques

검색결과 50건 처리시간 0.027초

패턴전사프린팅용 고분자 복제 소재 연구 (A Study on Polymer Replica Materials for Nanotransfer Printing)

  • 강영림;박운익
    • 한국전기전자재료학회논문지
    • /
    • 제34권4호
    • /
    • pp.262-268
    • /
    • 2021
  • For the past several decades, various next-generation patterning methods have been developed to obtain well-designed nano-to-micro structures, such as imprint lithography, nanotransfer printing (nTP), directed self-assembly (DSA), E-beam lithography, and so on. Especially, nTP process has much attention due to its low processing cost, short processing time, and good compatibility with other patterning techniques in achieving the formation of high-resolution functional patterns. To transfer functional patterns onto desirable substrates, the use of soft materials is required for precise replication of master mold. Here, we introduce a simple and practical nTP method to create highly ordered structures using various polymeric replica materials. We found that polymethyl methacrylate (PMMA), polystyrene (PS), and polyvinylpyridine (PVP) are possible candidates for replica materials for reliable duplication of Si master mold based on systematic analysis of pattern visualization. Furthermore, we successfully obtained well-defined metal and oxide nanostructures with functionality on target substrates by using replica patterns, through deposition and transfer process. We expect that the several candidates of replica materials can be exploited for effective nanofabrication of complex electronic devices.

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis

  • Mai, Hang-Nga;Lee, Kyeong Eun;Lee, Kyu-Bok;Jeong, Seung-Mi;Lee, Seok-Jae;Lee, Cheong-Hee;An, Seo-Young;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.358-363
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the reliability of computer-aided replica technique (CART) by calculating its agreement with the replica technique (RT), using statistical agreement analysis. MATERIALS AND METHODS. A prepared metal die and a metal crown were fabricated. The gap between the restoration and abutment was replicated using silicone indicator paste (n = 25). Gap measurements differed in the control (RT) and experimental (CART) groups. In the RT group, the silicone replica was manually sectioned, and the marginal and occlusal gaps were measured using a microscope. In the CART group, the gap was digitized using optical scanning and image superimposition, and the gaps were measured using a software program. The agreement between the measurement techniques was evaluated by using the 95% Bland-Altman limits of agreement and concordance correlation coefficients (CCC). The least acceptable CCC was 0.90. RESULTS. The RT and CART groups showed linear association, with a strong positive correlation in gap measurements, but without significant differences. The 95% limits of agreement between the paired gap measurements were 3.84% and 7.08% of the mean. The lower 95% confidence limits of CCC were 0.9676 and 0.9188 for the marginal and occlusal gap measurements, respectively, and the values were greater than the allowed limit. CONCLUSION. The CART is a reliable digital approach for evaluating the fit accuracy of fixed dental prostheses.

Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.179-186
    • /
    • 2013
  • PURPOSE. One of the most important factors in evaluating the quality of fixed dental prostheses (FDPs) is their gap. The purpose of this study was to compare the marginal and internal gap of two different metal-ceramic crowns, casting and selective laser sintering (SLS), before and after porcelain firing. Furthermore, this study evaluated whether metal-ceramic crowns made using the SLS have the same clinical acceptability as crowns made by the traditional casting. MATERIALS AND METHODS. The 10 study models were produced using stone. The 20 specimens were produced using the casting and the SLS methods; 10 samples were made in each group. After the core gap measurements, 10 metal-ceramic crowns in each group were finished using the conventional technique of firing porcelain. The gap of the metal-ceramic crowns was measured. The marginal and internal gaps were measured by two-dimensional and three-dimensional replica techniques, respectively. The Wilcoxon signed-rank test, the Wilcoxon rank-sum test and nonparametric ANCOVA were used for statistical analysis (${\alpha}$=.05). RESULTS. In both groups, the gap increased after completion of the metal-ceramic crown compared to the core. In all measured areas, the gap of the metal cores and metal-ceramic crowns produced by the SLS was greater than that of the metal cores and metal-ceramic crowns produced using the casting. Statistically significant differences were found between cast and SLS (metal cores and metal-ceramic crown). CONCLUSION. Although the gap of the FDPs produced by the SLS was greater than that of the FDPs produced by the conventional casting in all measured areas, none exceeded the clinically acceptable range.

와이어 방전가공을 이용한 상어 표피 모사 리블렛 표면 제작 (Fabrication of a Micro-riblet Shark Skin-like Surface using a WEDM Process)

  • 박영환;김태완
    • Tribology and Lubricants
    • /
    • 제32권6호
    • /
    • pp.201-206
    • /
    • 2016
  • In this study, we attempt to produce a semi-elliptical riblet with a shark skin-like surface using wire electrical discharge machining (WEDM) and micro molding techniques. Our design for the production of the semi-elliptical mold includes an electrode, a winding roller, and a guide on the WEDM system. A replication mold with negative riblets is machined using WEDM, and a shark skin inspired surface with positive riblets is fabricated using a micro molding technique. For a comparison with the original shark skin, a shark skin replica is also produced using the micro molding technique directly from a shark skin template. Droplet contact angles on a flat surface, the shark skin replica, and the epoxy resin-based micro riblet shark skin-like surface are evaluated. The effect of a Teflon coating on the contact angles for the three different surfaces is also investigated. The results show the micro riblet with a shark skin-like surface has a similar contact angle as the shark skin replica, which means that the simplified riblet shark skin surface strongly influences the performance of wettability. This study confirms the effectiveness of using the WEDM method to prepare hydrophobic surfaces with diverse surface patterns.

임플란트 보철 합착 시 잔여 시멘트 최소화를 위해 열가소성 접착제를 이용한 복제 지대주 제작 방법: 증례보고 (A technique for fabricating abutment replica with hot melt adhesive material to minimize residual cement in implant restoration: a case report)

  • 서치원;한아름;서재민;이정진
    • 구강회복응용과학지
    • /
    • 제32권3호
    • /
    • pp.240-245
    • /
    • 2016
  • 치은 연하 변연을 갖는 임플란트 수복물 장착시 잔여 합착제의 제거는 임플란트 생물학적 합병증을 예방하기 위해 매우 중요하다. 치은 연하 잔여 합착제를 최소화하기 위해 인상용 실리콘이나 자가중합형 레진을 이용하여 복제 지대주를 제작하는 여러 방법이 소개되었다. 본 증례에서는 열가소성 접착제(hot melt adhesive material)를 이용하여 복제 임플란트 지대주(abutment replica)제작하는 방법을 소개하고자 한다. 이 방법은 간단하고 부가적인 기공과정이 필요 없어 진료실에서 쉽게 이용할 수 있어 이에 보고하는 바이다.

고대 누금 세공기법 제작기술 연구 (The study of handiwork techniques of ancient granule)

  • 문환석;조남철;홍종욱
    • 보존과학연구
    • /
    • 통권22호
    • /
    • pp.81-92
    • /
    • 2001
  • The replica experiment of golden bell excavated from the East Three-Story Pagoda at the Gamunsa temple was carried out in order to know the handiwork technique of ancient granule. The size of 0.3mm granule was attached to the golden bell which was 3.4mm bell body by soldering. When we tried to attach the granule by a modern metalwork, we could know that this technique was hard to make the replica bell. We could prove how to adhere strongly to the golden granule by tension testing. First of all, we made the soldering of the same composition as the golden bell excavated from the Gamunsa temple and then prepared specimens for testing to measure the tension strength. It showed that the broken position was not a soldering part. This result showed how the ancient granule could maintain without a break for a long time.

  • PDF

Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques

  • Zhou, Ying;Li, Yong;Ma, Xiao;Huang, Yiqing;Wang, Jiawei
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.124-129
    • /
    • 2017
  • PURPOSE. This study evaluated the effect of span length on the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques. MATERIALS AND METHODS. Models with two solid abutment analogs at different inter-abutment distances were digitized using a laboratory scanner. Frameworks of two-, three-, and four-unit fixed prostheses were designed by a computer. Six dots with a diameter of 0.2 mm were preset on the surface of each framework. A total of 54 implant-supported cobalt chromium frameworks were fabricated by milling, selective laser melting (SLM), and cast techniques. The frameworks were scanned and exported as Stereolithography files. Distances between two dots in X, Y, and Z coordinates were measured in both the designed and fabricated frameworks. Marginal gaps between the framework and the abutments were also evaluated by impression replica method. RESULTS. In terms of distance measurement, significant differences were found between three- and four-unit frameworks, as well as between two- and four-unit frameworks prepared by milling technique (P<.05). Significant differences were also noted between two- and three-unit frameworks, as well as between two- and four-unit frameworks prepared by cast technique (P<.05). The milling technique presented smaller differences than the SLM technique, and the SLM technique showed smaller differences than the cast technique at any unit prostheses (P<.05). Evaluation with the impression replica method indicated significant differences among the span lengths for any fabrication method (P<.05), as well as among the fabrication methods at any unit prostheses (P<.05). CONCLUSION. The adaptation of implant-supported cobalt chromium frameworks was affected by the span length and fabrication method.

성주 이씨가(家) 초상화의 과학적 분석을 통한 모사복원방안 연구 (A Study on Replica Restoration Methods through Scientific Analysis of Seongju Lee Family's Portraits)

  • 정지윤;이장존;한민수
    • 보존과학회지
    • /
    • 제38권3호
    • /
    • pp.201-216
    • /
    • 2022
  • 성산사에 봉안되어 있는 성주 이씨가(家) 초상화 중 2점(이조년, 이숭인)을 대상으로 사용재료 및 기법에 대한 과학적 분석을 실시하고, 그 데이터를 기반하여 최적의 모사복원방안을 설계하였다. 표현 기법 조사 결과, 두 진영 모두 선묘 위주로 표현되었지만, 신발과 눈동자, 육색 표현, 가채, 보강 흔적 등에서 차이를 보였다. 안료 분석 결과, 공통적으로 적색 안료는 주사와 연단의 혼합 혹은 유기 안료를 사용하였으며, 청색 안료는 석청을 사용했다. 녹색 안료는 석록(Malachite)이 사용되었고, 백색 안료는 연백을 사용했다. 황색 안료는 유기 안료와 금박이 사용된 것으로 추정된다. 이숭인 진영은 석간주와 녹염동광(Atacamite)도 사용되었다. 또한 동시대 사대부상과 비교한 결과, 두 초상화에서 당시 초상화 양식이 발견되나 변형된 특이점이 존재하였다. 과학적 분석 데이터를 기반으로 하여 이조년 진영은 고색복원모사, 이숭인 진영은 현상모사로 결정하였다. 육안으로 확인하기 어려운 표현 기법들을 과학적 분석 데이터로 보완하여 세부적인 채색 기법을 제시하였다. 또한 각 색상별로 초상화에서 대표적인 위치의 색도를 측정하여 평균값을 계산한 색상 기준값을 제시함으로써 유물의 현재 색상을 최대한 객관적 데이터를 근거로 하여 모사복원할 수 있도록 하였다.

그리드 환경에서 효율적인 작업 처리를 위한 대용량 파일 프로비저닝 방안 (Provisioning Scheme of Large Volume File for Efficient Job Execution in Grid Environment)

  • 김은성;염헌영
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제15권8호
    • /
    • pp.525-533
    • /
    • 2009
  • 그리드 환경에서 작업에 필요한 파일은 스테이징 기법에 의해서 전송된다. 이때 요구되는 파일이 대용량일 경우 전송에 걸리는 시간이 늘어나 작업의 시작 시간을 지연시키게 되다. 또한, 이는 작업의 전체 실행 시간을 증가시키는 요인이 되어서 작업처리량을 감소시키는 결과를 가져오게 된다. 따라서 이러한 파일 전송 시간 때문에 생기는 오버헤드를 줄인다면 그리드에서 실행되는 작업의 효율을 상당히 향상 시킬 수 있다. 이러한 사실에 근거하여 본 논문에서는 그리드에서 효율적인 작업 처리를 위한 파일 프로비저닝 기법으로서 다음과 같은 두 가지 방법을 제안한다. 첫째, RA-RFT라는 방법을 제안한다. RA-RFT는 Globus Toolkit에서 파일 전송을 담당하는 RFT가 리플리카를 관리하는 RLS의 정보를 이용할 수 있도록 RFT를 확장한 것이다. RA-RFT는 파일 전송 시 가용한 리플리카들로부터 파일을 분할 전송함으로써 대용량 파일 전송 시간을 단축시킬 수 있다. 둘째 리모트 링크라는 방법을 제안한다. 리모트 링크는 파일을 계산 노드로 직접 전송하지 않고 계산 노드에서 파일에 원격 접근할 수 있는 방법을 제공한다. 원격 접근 방법을 이용함으로써 계산 노드의 저장 공간을 절약할 수 있고 선반입을 통해서 효율적인 파일 프로비저닝을 가능하게 한다. 우리는 이러한 두 가지 방법이 기존 그리드 환경에서 사용하고 있는 스테이징 방식보다 우월한 성능을 보여준다는 것을 다양한 실험을 통해서 증명한다.