• 제목/요약/키워드: Replica technique

검색결과 133건 처리시간 0.024초

첨가법에 의해 제작된 단관의 내면 적합도 분석 (Analysis of internal fitness of single crown fabricated by additive method)

  • 김원수
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.229-234
    • /
    • 2015
  • Purpose: The purpose of this study was to analysis the internal fitness of single crown fabricated by additive method technique. Methods: Study models were fabricated. Ten crowns were manufactured by additive method technique (AM group) and another ten crowns using conventional method were manufactured (CM group). The internal fitness of specimens were measured using silicone replica technique. Silicone replicas were sectioned one times (direction: from mesial to distal). The internal fitness were evaluated using by digital microscope. Statistical analyses were performed with independent samples t-test. (${\alpha}=0.05$). Results: Mean(SD) of all internal fitness were $92.1(20.0){\mu}m$ for AM group and $69.7(12.3){\mu}m$ for CM group. Two groups were statistically significant differences (p<0.001). Conclusion: All internal gaps of AM group were ranged within the clinical recommendation ($120{\ss}{\neq}$).

Self-Power Gating Technique For Low Power Asynchronous Circuit

  • Mai, Kim-Ngan Thi;Vo, Huan Minh
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.548-557
    • /
    • 2018
  • In this paper, Asynchronous Self-Power Gating technique (ASPG) is used to reduce consumption power in asynchronous digital watch application. The power gating control signal is automatically generated by internal system operation characteristics instead of using replica circuit delay or four-phase handshaking protocol. Isolation cell is designed to insert it between power gating domain and normal operation domain. By using self-power gating circuit, asynchronous digital watch application consumes very low power and maintains data during sleep mode. The comparison results show the proposed ASPG technique saves leakage power up to 40.47% and delay time is reduced to 71% compared to the conventional circuit.

비드를 이용한 면역분석용 마이크로필터 칩의 제작 (Microfilter Chip Fabrication for Bead-Based Immunoassay)

  • 이승우;안유민;채영규
    • 대한기계학회논문집A
    • /
    • 제28권9호
    • /
    • pp.1429-1434
    • /
    • 2004
  • Immunoassay is one of the important analytical methods for clinical diagnoses and biochemical studies, but needs a long time, troublesome procedures and expensive reagents. In this study, therefore, we propose the micro filter chip with microbeads for immunoassay, which has pillar structures. The advantage of the proposed micro filter chip is to use simple fabrication process and cheap materials. The mold was made by the photolithography technique with Si wafer and negative photoresist SU-8. The replica was made of PDMS, bonded on the pyrex glass. The micro filter chip consists of inlet channel, filter chamber and outlet channel. HBV (Hepatitius B virus) monoclonal antibody (Ag1) labeled with biotin were immobilized onto streptavidin coated beads of 30∼50 $\mu$m size. Fluorescein isothiocyanate (FITC)-labeled HBV monoclonal antibody (Ag8) was used to detect HBsAg (Hebatitis B virus surface Antigen), and fluorescence intensity was monitored by epi-fluorescence microscope. In this study, the immune response of less than 30 min was obtained with with the use of 100 $m\ell$ of sample.

광자결정 도파로 성형용 PDMS 스탬프 제작 (PDMS Stamp Fabrication for Photonic Crystal Waveguides)

  • 오승훈;최두선;김창석;정명영
    • 한국정밀공학회지
    • /
    • 제24권4호
    • /
    • pp.153-158
    • /
    • 2007
  • Recently nano imprint lithography to fabricate photonic crystal on polymer is preferred because of its simplicity and short process time and ease of precise manufacturing. But, the technique requires the precise mold as an imprinting tool for good replication. These molds are made of the silicon, nickel and quartz. But this is not desirable due to complex fabrication process, high cost. So, we describe a simple, precise and low cost method of fabricating PDMS stamp to make the photonic crystals. In order to fabricate the PDMS mold, we make the original pattern with designed hole array by finding the optimal electron beam writing condition. And then, we have tried to fabricate PDMS mold by the replica molding with ultrasonic vibration and pressure system. We have used the cleaning process to solve the detaching problem on the interface. Using these methods, we acquired the PDMS mold for photonic crystals with characteristics of a good replication. And the accuracy of replication shows below 1% in 440nm at diameter and in 610nm at lattice constant by dimensional analysis by SEM and AFM.

Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

  • Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 2017
  • PURPOSE. The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS. Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with ${\alpha}$-level of 0.05. RESULTS. 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION. Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.

2.25Cr1Mo강의 크리프 손상에 대한 초음파 시험평가 (Ultrasonic Evaluation for the Creep Damage of 2.25Cr1Mo Steel)

  • 허광범;이인철;정계조;조용상;이상국;김재훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.31-36
    • /
    • 2000
  • High temperature and pressure materials in power plant are degraded by creep damage, if they are exposed to constant loads for long times, which occurs in the load bearing structures of pressurized components operating at elevated temperatures. Many conventional measurement techniques such as replica method, electric resistance method, and hardness test method for measuring creep damage have been used. So far, the replica method is mainly used for the Inspection of High temperature and pressure components. This technique is, however, restricted to applications at the surface of the testpieces and cannot be used to material inside. In this paper, ultrasonic evaluation for the detection of creep damage in the form of cavaties on grain boundaries or integranular microcracks are carried out. And the absolute measuring method of quantitative ultrasonic velocity technique for Cr-Mo material degradation is analyzed. As a result of ultrasonic tests for crept specimens, we find that the sound velocity is decreased as the increase of creep life fraction$({\Phi}_c)$ and also, confirmed that hardness is decreased as the increase of creep life fraction$({\Phi}_c)$ but the coefficient of ultrasonic attenuation is increased as the increase of creep life fraction$({\Phi}_c)$. Finally based on the result in this paper, it can be recognized that the ultrasonic techniques using velocities and attenuation coefficient factor are very useful non-destructive methods to evaluate the degree of material degradation in fossile power plants.

  • PDF

Particle Replication In Non-Wetting Templates (PRINT) 방법을 이용한 약물 및 유전자 전달체의 제작 (Fabrication of Non Viral Vector for Drug and Gene Delivery using Particle Replication In Non-Wetting Templates (PRINT) Technique)

  • 박지영;;;임종성
    • Korean Chemical Engineering Research
    • /
    • 제45권5호
    • /
    • pp.493-499
    • /
    • 2007
  • 본 연구에서는 UV photo-lithography 방식의 particle replication in non-wetting templates(PRINT) 법을 이용하여 약물 전달에 운반체로 사용되는 $3{\mu}m{\times}3{\mu}m{\times}2{\mu}m$ 사이즈의 균일한 고분자 하이드로젤 입자를 제조하였다. 몰드(mold)와 기재(substrate)는 PRINT 방식을 통하여 탄성을 지닌 perfluoropolyethers(PFPE)로 제작하였으며 이를 반복적으로 사용할 수 있도록 하였다. 제작된 입자는 점착성이 있는 수용성 고분자를 이용하여 회수하였다. 입자의 주요 성분은 생분해성 고분자인 poly(ethylene glycol) diacrylate(PEG-diA)이며, 세포 uptake에 적합하도록 aminoethylacrylate(AEM)와 2-acryloxyethyltrimethyl ammonium chloride(AETMAC)를 첨가하였다. 본 연구를 통해 균일하고 원하는 크기의 생체분해성 고분자 입자를 제작하는 PRINT 기술이 약물 전달 및 유전자 전달에 필요한 수송체인 비바이럴 벡터를 제작하기 위한 효과적인 기술임을 제시하였다.

디지털 복원을 통한 태조어진太祖御眞의 형태 고찰 (A Study on the Shape of the Portrait of King Taejo Using Digital Restoration)

  • 곽은경;손태호;이현주
    • 보존과학회지
    • /
    • 제32권1호
    • /
    • pp.51-61
    • /
    • 2016
  • 어진御眞은 왕의 초상화로 조선시대에는 국조인 태조를 비롯하여 다수의 어진이 제작되어 영흥 준원전, 전주 경기전 등 여러 진전眞殿에 봉안奉安되었다. 이러한 어진은 이모移摸 과정을 통해 전해지고 있으며, 훼손된 어진의 경우 모사模寫 과정을 토대로 신본新本을 제작하였다. 근래에는 어진에 대한 다양한 학술적인 가치와 국민적인 관심 증대로 인하여 이모 작업이 활발하게 진행되고 있다. 국립고궁박물관에서는 다수의 어진을 보유하고 있는데, 소장본중 대부분이 한국전쟁 중 화재로 인해 손상된 상태로, 이모본 제작 과정에 필요한 초본 제작을 위해서는 범본範本이 되는 어진의 훼손된 부분에 관한 복원이 필요하다. 이 논문에서는 다분할 촬영 기법 및 이미지 분석 등의 디지털 이미징 기술을 활용하여, 국립고궁박물관 소장 태조어진의 훼손된 부분을 복원하는 과정과 이를 통해 밝혀진 태조어진 유물들의 용안의 차이를 중심으로 각 유물의 관계에 대해 연구한 것이다.

급속소결이 다층 지르코니아 치과보철물의 변연 및 내면 적합도에 미치는 영향 (Effect of the speed sintering schedule on the marginal and internal gaps of multi-layered zirconia prothesis)

  • 김세연;김재홍
    • 대한치과기공학회지
    • /
    • 제44권1호
    • /
    • pp.1-7
    • /
    • 2022
  • Purpose: The purpose of this in vitro study is to evaluate the clinical acceptability of the marginal discrepancies and internal spacing of multi-layered zirconia prothesis by speed sintering. Methods: The two specimen types come from the same manufacturer but differ in the ingredients in layered zirconia and indication, that is anterior and posterior. The designs of both specimens were full contour crowns, and a total of 20 pieces were repeatedly fabricated, 10 for each group. The specimens were divided into two subgroups (n=10) and sintered with various total times (4 hours, 8 hours) at the maximum temperature (1,530℃). The gap between the two groups of multi-layered zirconia prostheses was measured using a silicone replica technique of 2D analysis method. The independent sample t-test was then used to compare and analyze the data obtained from the two groups (α=0.05). Results: The marginal and internal gap was superior in the 8-hour compared to the 4-hour group, and the results exhibited significant differences (p<0.05). All specimens showed that using the speed sintering schedule does not exceed the clinically permitted value of 120 ㎛, meaning zirconia prothesis using the speed sintering was adequate. Conclusion: The sintering condition is shown to affect the marginal and internal gaps of multi-layered zirconia restoration.

시멘트 공간이 적층 가공으로 제작한 지르코니아 하부구조물의 변연 및 내면 적합도에 미치는 영향 (Effect of cement space on marginal and internal fit of a zirconia core fabricated using by additive manufacturing)

  • 민지원;김세연;김재홍
    • 대한치과기공학회지
    • /
    • 제46권1호
    • /
    • pp.1-7
    • /
    • 2024
  • Purpose: The goal of this study was to determine the clinical acceptability of various cement space settings for the marginal and internal fit of a zirconia core manufactured using additive manufacturing. Methods: The maxillary right incisor served as the master model. After scanning the maxillary right incisor with a dental 3D (three-dimensional) scanner, the stereo lithography file was created using different cement space settings of 40, 120, and 200 ㎛ using computer-aided design software (Dental System 2018; 3Shape). The marginal and internal fit of the 3 groups were determined using the silicon replica technique. Measurement points were divided into the following three categories: margin, axial wall, and incisal. To ensure more accurate measurements, these three measurement points were divided into 8 points. The Shapiro-Wilk, one-way ANOVA, and Tukey's honestly significant difference test (for all tests α=0.05) were the statistical analyses that were included in the study. Results: The CS (cement space)-200 group had better marginal and internal fit than the CS-40 and CS-120 groups, and there were statistically significant differences at the marginal and incisal points, except for the axial wall points. CS-200 group, both marginal and internal fit were within 120 ㎛, which is the clinically acceptable value. Conclusion: This study suggests that a 200 ㎛ cement space setting is ideal for optimal marginal and internal fit of 3D-printed ceramic crowns.