• Title/Summary/Keyword: Repetition rate

Search Result 431, Processing Time 0.022 seconds

The high repetition operating characteristics of pulsed Nd:YAG laser by alternating charge-discharge system (펄스형 Nd:YAG 레이저의 교번 충.방전 방식에 의한 고반복 동작특성)

  • Kim, W.Y.;Park, K.R.;Kim, B.G.;Hong, J.H.;Kang, U.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2204-2206
    • /
    • 1999
  • Pulsed Nd:YAC laser is used widely for materials processing and instrumentation. It is very important to control the laser energy density in materials processing by a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, the alternating charge-discharge system was designed to adjust a pulse repetition rate. This system is controlled by one chip microprocessor and allows to replace an expensive condenser for high frequency to a cheap condenser for low frequency. In addition. we have investigated the current pulse shape of flashlamp and the operating characteristics of a pulsed Nd:YAG laser. As a result, it is found that the laser output of the power supply using the alternating charge-discharge system is not less than that of typical power supply. As the pulse repetition rate rises from 30pps to 120pps by the step of 30pps at 1200V, it is found that the laser efficiency decreases but the laser output power increases about 6W at each step.

  • PDF

Diadochokinetic Characteristics in the Subjects with Spastic Cerebral Palsy by Severity: In Terms of Rate, Regularity, Accuracy and Consistency (심한 정도에 따른 경직형 뇌성마비 대상자의 교호운동 특성: 속도, 규칙성, 정확성, 일관성을 중심으로)

  • Nam Hyun-Wook;Ahn Jong-Bok;Kwon Do-Ha
    • MALSORI
    • /
    • no.58
    • /
    • pp.1-18
    • /
    • 2006
  • The purpose of this study was to investigate diadochokinetic (DDK) characteristics in the subjects with spastic cerebral palsy (CP) by severity. DDK characteristics were measured through rate, regularity, accuracy and consistency in Alternate Motion rate (AMR) and Sequential Motion rate (SMR) tasks. The subjects participated in this study included 27 subjects with spastic CP (mild- 9, moderate- 9, severe- 9) and 9 normal persons who are around 11-20 years old. On the result of this study, rate in AMR was significant difference between all spastic groups and normal group, and rate in SMR was significant difference between normal and mild groups and moderate and severe groups. In regularity of the DDK tasks, severe group had significant difference the other groups. Finally, accuracy and consistency of the DDK tasks exhibited significant difference between all spastic groups and normal group. In conclusion, the subjects with spastic CP have a tendency to produce slow and irregular syllable repetition as severity increases, but to produce inaccurate and inconsistent syllable repetition regardless of severity in the DDK tasks.

  • PDF

Quantitative Evaluation on Laser Performance for Endovenous Photocoagulation (레이저를 이용한 하지정맥류 치료의 정량화 연구)

  • Ahn, Minwoo;Nguyen, Van Phuc;Oh, Junghwan;Kang, Hyun Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.62-67
    • /
    • 2014
  • The purpose of the study was to identify the effect of laser parameters on photocoagulation to maximize safety and efficacy during varicose vein treatment. CW and pulsed modes at 1470 nm were initially compared as a function of power on bovine liver tissue. In the pulsed mode, various parameters including repetition rate, duty cycle, and irradiation time were compared to evaluate tissue response during thermal treatment. The results demonstrated that CW and pulsed modes yielded almost similar coagulation development possibly due to shorter irradiation time of 5 sec. Regardless of laser mode, both repetition rate and duty cycle presented constant coagulation rate whereas longer irradiation time facilitated coagulation process.

A Study on the Chemical and Dyeing Properties of Rhus Verniciflua Extract (옻나무 추출액의 염색성)

  • Kim Ae Soon
    • Textile Coloration and Finishing
    • /
    • v.16 no.6
    • /
    • pp.16-22
    • /
    • 2004
  • This study was carried out to investigate K/S values, surface color, the fastness to washing, bacteria reduction rate of the silk and cotton fabrics dyed with Rhus verniciflua extract under the various dyeing conditions. The optimum dyeing temperature, dyeing time, dyeing pH and repetition of the silk fabrics dyed with Rhus verniciflua extract were $l00^{\circ}C, 30min., pH 5, five times repetition respectively, but in the cotton fabrics, it were $60^{\circ}C . 30min., pH 7, one times repetition. It were colored orangish Yellow in the silk fabrics and colored bright yellow in the cotton fabrics dyed with Rhus verniciflua extract. Surface color(munsell value) was not changed by the mordanting agents but those of the silk showed high tone when mordanting with stannous chloride, and it was decolored and darked when mordanting with ferric sulfate. The fastness to washing in the silk fabrics dyed with mordanting agents improved in 4~5 grade, but the cotton fabrics were 3~4 grade, so washing fastness of the silk and cotton fabrics were significantly improved when washing with the neutral detergent. The bacteria reduction rate of the silk fabrics increased drastically by dyeing of Rhus verniciflua extract.

Development of 4Hz Medical Ruby Laser System with Double Cavities using Multi-Resonant Converter (다중 공진형 컨버터를 이용한 이중 캐비티 구조의 4Hz 의료용 루비레이저 시스템 개발)

  • Lee, Jae-cheol;Zheng, Tao;Shengxu, Piao;Xu, Guo-Cheng;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1207-1211
    • /
    • 2015
  • Various laser systems have been widely used in almost all industrial technologies because they have high energy density, directivity and coherence. Recently the clinical application is becoming wider in medical parts such as incurable disease, diagnosis and so on. Generally, ruby laser beam has the greatest efficacy for removing tattoos, freckle and other skin problem. But current medical ruby laser system has the maximum repetition rate of 2Hz and optical output beam energy of 1J. Many medical doctors really want to have a high repetition ruby laser system because that can reduce the operation time. We investigated a new ruby laser system with high repetition rate of 4Hz using double cavities. Furthermore, we develop a new power supply system adopting zero voltage switching(ZVS) to minimize switching loss by LLC resonant converter designed as 2kW class.

Implementation of the Variable Output Laser Diode Driver Synchronized with a Pulse Repetition Frequency Code (펄스 반복 주파수 코드에 동기된 출력 가변형 레이저 다이오드 드라이버 구현)

  • Lee, Young-Ju;Kim, Yong-Pyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.746-750
    • /
    • 2015
  • In this paper, we propose a simulator to evaluate the performance of the semi-active laser guidance or the quadrant photodetector and to simulate the laser power reflected from a target. The laser pulse repetition frequency was generated and synchronized with the laser pulse repetition(PRF) code. To evaluate the performances of the proposed methods, we implemented a prototype system and performed experiments. As a result, the generated high voltage was variable in the range of DC 3V to 340V and has the rate of change of 2000 V/s. PRF code can be generated within 50ms ∼ 100ms and the error is implemented within 0.3ns. The laser output is synchronized with the PRF code and has a dynamic range of 23.6dB.

The Effects of PRF and Slot Interval on the PPM-Based Ultra Wide-Band Systems (PPM-기반의 UWB 시스템에 대한 PRF와 슬롯 시간의 영향)

  • 김성준;임성빈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.12C
    • /
    • pp.1192-1199
    • /
    • 2003
  • In this paper, we investigate the effect of pulse repetition frequency (PRF) and slot interval on the throughput performance of the ultra wide band (UWB) wireless communication system in multi-path channels, and based on these observations, a data throughput control using PRF and slot interval is proposed for maximizing the effective throughput. Recently, due to many desirable features of the UWB system, it has drawn much attention especially for short-range high-speed data transmission. The UWB system has two parameters to determine its data throughput; pulse repetition frequency and slot interval. In the multi-path channel with additive white Gaussian noise, the UWB system suffers from the inter-pulse interference (IPI) and noise, which result in degradation of system performance. The UWB system can vary the two parameters to maintain and/or improve the system performance. In this paper, we demonstrate the effects of the two parameters on the data throughput of the UWB system in various multi-path indoor channels through computer simulation, and show that the variable data rate approach designed based on the observations is superior to the fixed data rate one in terms of effective throughput performance.

Dyeability and UV-blocking Effect of Dyed Fabrics with Ginkgo Extract (은행잎의 염색성 및 자외선 차단 효과)

  • Song, Eun-Young;Song, Myung-Kyun
    • The Korean Journal of Community Living Science
    • /
    • v.18 no.3
    • /
    • pp.391-398
    • /
    • 2007
  • Ginkgo leaves, which have been known as medical materials, were selected as new natural dyes in this study, in which it was examined whether they have the function of UV-blocker or not. Cotton, linen & Hanji(Korean traditional paper) were dyed with Ginkgo. Al, Cr, Cu, Fe and Sn were selected as mordants. UV-blocking rate of dyed samples was measured after dyeing and mordant treatment. The results of this study are as follows. First, most surface color of dyed samples was yellow except that Hanji mordanted with Cu was yellowish red. Second, dyeing repetition had positive correlations with K/S values of cotton ($r=.\;758^{**}$), linen ($r=.\;500^*$) and Hanji ($r=.\;819^{**}$), because K/S values were increased according to dyeing repetition. Third, solar UV-blocking rates had positive correlations with dyeing repetitions (p<0.01), because UV-blocking rates had increased according to dyeing repetition. Fourth, UV-blocking ability of Hanji was highest among samples, as UV-blocking rates of cotton and linen dyed after 3 dyeing repetition were up to 93%, Hanji's values were up to 98%. Therefore, it was proven that Ginkgo extracts used in this experiment as dyestuff have excellent dyeing ability and high UV-blocking ability. It is hoped that this work will lead to further research to confirm the physiological effects when human wear the clothes made from Hanji.

  • PDF

Analysis of Specific Absorption Rate in Magnetic Resonance Imaging (자기공명영상장치에서 전자파흡수율 분석)

  • Han, Jae-Bok;Hong, Seong-Hun;Choi, Nam-Gil;Seong, Ho-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.2
    • /
    • pp.308-313
    • /
    • 2013
  • In this paper, we measured specific absorption rate (SAR) using characteristic variables such as flip angle, repetition time (TR) and echo time (TE) at magnetic resonance imaging. The subject was applied to same scan technique from body weight 10 kg to 90 kg, were measured for the average SAR and the peak SAR values according to the change of parameter. SAR with different body weight levels was not seen a significant change at TE but it increased in the larger flip angle and the shorter TR. SAR value was within the limits of human head acceptable standard and SNR in segmental body weights was not proportional to the increase of body weights. In conclusion, this study can be helpful for diagnosis by using appropriate parameters which obtained the various contrast and SNR.

A Pulser System with Parallel Spark Gaps at High Repetition Rate

  • Lee, Byung-Joon;Nam, Jong-Woo;Rahaman, Hasibur;Nam, Sang-Hoon;Ahn, Jae-Woon;Jo, Seung-Whan;Kwon, Hae-Ok
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.305-312
    • /
    • 2011
  • A primary interest of this work is to develop an efficient and powerful repetitive pulser system for the application of ultra wide band generation. The important component of the pulser system is a small-sized coaxial type spark gap with planar electrodes filled with SF6 gas. A repetitive switching action by the coaxial spark gap generates two consecutive pulses in less than a microsecond with rise times of a few hundred picoseconds (ps). A set of several parameters for the repetitive switching of the spark gap is required to be optimized in charging and discharging systems of the pulser. The parameters in the charging system include a circuit scheme, circuit elements, the applied voltage and current ratings from power supplies. The parameters in the discharging system include the spark gap geometry, electrode gap distance, gas type, gas pressure and the load. The characteristics of the spark gap discharge, such as breakdown voltage, output current pulse and recovery rate are too dynamic to control by switching continuously at a high pulse repetition rate (PRR). This leads to a low charging efficiency of the spark gap system. The breakthrough of the low charging efficiency is achieved by a parallel operation of two spark gaps system. The operational behavior of the two spark gaps system is presented in this paper. The work has focused on improvement of the charging efficiency by scaling the PRR of each spark gap in the two spark gaps system.