• Title/Summary/Keyword: Removal ratio

Search Result 1,609, Processing Time 0.031 seconds

The Effect of Fixed Media and Recycling Ratio on Nutrients Removal in a Pilot-Scale Wastewater Treatment Unit (고정식 담체 유무와 반송비에 따른 소규모 하수처리 시스템 내 영양염류 제거 특성)

  • Hwang, Jae-Hoon;Cho, Dong-Wan;Kim, Chung-Hwan;Jeon, Byong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.6
    • /
    • pp.449-455
    • /
    • 2013
  • The effect of recycling ratio and fixed media on nitrate and phosphate removal was investigated in a pilot-scale wastewater treatment unit using synthetic wastewater. Addition of fixed media increased nitrate removal from 45 to 58% while no noticeable change was observed for Chemical Oxygen Demand (COD) and phosphate removal (<5%). Nitrate removal efficiency also enhanced (Ca 7%) when the influent wastewater flow was doubled (2Q), however phosphate removal was decreased from 40.9 to 26.6% with the increasing recycling rate. The attached biomass analysis showed the presence of bacteria (73.4 $mg/cm^2$) on the surface of added media in anoxic reactor. Pseudomonas aeruginosa a common denitrifying bacterium dominated the bacterial growth (58%) in the anoxic reactor which was determined using Fluorescence In Situ Hybridization (FISH) analysis.

Effect of the supernatant reflux position and ratio on the nitrogen removal performance of anaerobic-aerobic slaughterhouse wastewater treatment process

  • Tong, Shuang;Zhao, Yan;Zhu, Ming;Wei, Jing;Zhang, Shaoxiang;Li, Shujie;Sun, Shengdan
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.309-315
    • /
    • 2020
  • Slaughterhouse wastewater (SWW) is characterized as one of the most harmful agriculture and food industrial wastewaters due to its high organic content. The emissions of SWW would cause eutrophication of surface water and pollution of groundwater. This study developed a pilot scale anaerobic-aerobic slaughterhouse wastewater treatment process (AASWWTP) to enhance the chemical oxygen demand (COD) and total nitrogen (TN) removal. The optimum supernatant reflux position and ratio for TN removal were investigated through the modified Box-Behnken design (BBD) experiments. Results showed that COD could be effectively reduced over the whole modified BBD study and the removal efficiency was all higher than 98%. The optimum reflux position and ratio were suggested to be 2 alure and 100%, respectively, where effluent TN concentration was satisfied with the forthcoming Chinese discharge standard of 25 mg/L. Anaerobic digestion and ammonia oxidation were considered as the main approaches for COD and TN removal in the AASWWTP. The results of inorganic nutrients (K+, Na+, Ca2+ and Mg2+) indicated that the SWW was suitable for biological treatment and the correspondingly processes such as AASWWTP should be widely researched and popularized. Therefore, AASWWTP is a promising technology for SWW treatment but more research is needed to further improve the operating efficiency.

The Hydraulic simulation and removal characteristics of Escherichia Coli for Ultraviolet rays.Ozone sterilization apparatus (자외선.오존 살균소독장치의 유체시뮬레이션 및 대장균 제거 특성)

  • Hwang, In-Ah;Lee, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.169-172
    • /
    • 2005
  • The simulation of Hydraulic pressure distribution of discharge tube with globular beads and the removal characteristic of Escherichia coli by the discharge tube with globular beads were estimated. The removal characteristic of Escherichia coli was related to the input voltage because the electric field is increased according to input voltage. As the passing amount of test water in discharge tube is increased, the removal ratio of Escherichia coli was increased because passing numbers of electric field section is increased.

  • PDF

A Study on Improvement of Sewage Treatment System (오염처리장의 처리효율 개선연구)

  • 성일화
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.36-40
    • /
    • 1993
  • The objective of this research was to retrofit an on-site sewage treatment system suitable to current situation of Korea to reduce the pollution loading and preserve the invaluable water resources. Operation at the F/M ratio of 0.1 kg. BOD/kg MLSS day showed 87.1% BOD removal efficiency and 84.5% COD removal efficiency, and its effluent concentration was 6.4 mg/l as BOD and 21.7 mg/l as COD. Average removal of total nitrogen showed high removal efficiency of 80%.

  • PDF

Removal Characteristics of Nitrogen and Phosphorus in swine wastewater by Using Acetic acid on the SBR Process (SBR에서 아세트산을 이용한 양돈폐수의 질소·인 제거 특성)

  • Huh, Mock;Kang, Jin-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.1
    • /
    • pp.84-93
    • /
    • 2004
  • This study was performed : 1) to find the suitable HRT(hydralic retention time), 2) to evaluate the effects of the ratio of mixing/aeration time and injection time of external carbon source, for the removal of organics, nitrogen and phosphorus in swine wastewater by SBR(sequencing batch reactor process), which is one of the biological treatment process. The result of this study were summarized as follows : (1) As the ratio of mixing/aeration time was higher, $NH_4{^+}-N$ removal efficiency was increased and it was increased with increasing injection time of external carbon source because nitrification was affected by denitrification microbes propagation when injection time of external carbon soruce was shorted. T-N removal efficiency was increased with increasing the ratio of mixing/aeration time and injection time of external carbon source. (2) The T-P removal efficiency showed a great difference in each operating condition, and it was increased with increasing the ratio of mixing/aeration time increased and when the injection time of external carbon source was shorted because denitrification was done with effect by denitrification microbes propagation. (3) The highest removal efficiency of organic and nitrogen were obtained by the operating condition of Run 4-1(the ratio of mixing/aeration time : 16.5/5.5, injection time of external carbon source : 15hours) and T-P were obtained by the operation condition of Run 4-2(the ratio of mixing/aeration time : 16.5/5.5, injection time of external carbon source : 3hours), and efficiency(effluent concentration)of $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, T-N and T-P in the treated water was 96.1%, 87.7%, 90.6%, 86.6% and 84.5%, respectively.

  • PDF

Development of a Rotating Biological Contactor(RBC) Process for the Advanced Wastewater Treatment (회전원판(回轉圓板) 생물막(生物膜) 공법(工法)을 이용한 하(下)·폐수(廢水)의 고도처리(高度處理) 공정(工程) 개발(開發))

  • Kim, Eung Ho;Park, Jae Lo;Yoon, Jung Ro
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.2
    • /
    • pp.1-11
    • /
    • 1994
  • This study was conducted to develop a new RBC process available for the effective removal of organic matters and nitrogen in sewage. The RBC process for the oxidation organic compounds and nitrification was designed to occur at the 1st-stage and next-stage RBC respectively. Then nitrified water was recycled to the denitrifying RBC located at the lower part of the 1st-stage RBC. Some results were summarized as follows. 1. The loading limitation was represented as $60g{\cdot}COD/gm^2/day$ in experiment of simultaneous removal of organic matter and nitrogen. The maxmum COD % removal was 85% at the load $35g{\cdot}COD/m^2/day$. 2. The $NO_3-N$ % removal was approximately 80% at the load $60g{\cdot}COD/m^2/day$ and the maximum $NO_3-N$ remaval rate was $3.9g{\cdot}COD/m^2/day$ and the overall C/N ratio of 11.0 as required to achive 80% of $NO_3-N$% removal. 3.$NO_3-N$ removal rate was rapidly decreased above the load $7g{\cdot}NH_4{^+}-N/m^2/day$ and the maximum $NO_3-N$ removal rate was $3.7g{\cdot}NO_3-N/m^2/day$. 4. Irrespective of the recycle ratio, the COD % removal at the system of 2-stage RBC unit was nearly constant as 89% while the maximum one in the 1st-stage unit was 77% in the case of 50% recycle. 5. The maximum COD % removal in the 3-stage RBC system was 93% while 1st-stage one being 80%, under the $NH_4{^+}-N$ load of $7.4g/m^2{\cdot}d$. Also maximum percentage of nitrification and denitrification was 69% and 41% respectively, under the same $NH_4{^+}-N$ load.

  • PDF

Comparative Study on Element Removal Methods for ESO (진화적 구조 최적화를 위한 요소 제거법의 비교 연구)

  • 한석영
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.5
    • /
    • pp.112-118
    • /
    • 2000
  • In case ESO(evolutionary structural optimization) which is one of topology optimization methods, the element removal ratio is fixed throughout topology optimization by 1 or 2%. As a result it has no flexibility for various types of structures and thus the rate of convergence might not be efficient. Thus various element removal methods were developed in order to improve the efficiency of ESO. In this paper, various element removal methods for ESO are compared with each other for a bracket and a short cantilever. In addition, a new improved bi-directional element removal method is suggested in order to obtain much better optimized topology. From the comparative results of the examples, it is verified that all of the developed various element removal methods are very effective, and the suggested element removal method is the most effective.

  • PDF

Detergency of Particulate Soil in Anion/Nonionic Surfactant Mixed Solution (음이온/비이온 혼합 계면활성제 용액에서의 고형오구의 세척성)

  • Kang, In-Sook
    • Fashion & Textile Research Journal
    • /
    • v.13 no.5
    • /
    • pp.790-796
    • /
    • 2011
  • This study was designed to investigate the influence of ratio of anionic/nonionic surfactant mixture on detergency of particulate soil under various solutions. The detergency of the particulate soil was determined by adhesion of particle to fabric and its removal from fabric separately. The PET fabric and ${\alpha}-Fe_2O_3$were used as materials of textile and model of particulate soil, respectively. The detergency was investigated as a function of surfactants concentration, ionic strength, kinds of electrolyte and mole numbers of oxyethylene ether of nonionic surfactant in different ratio of anionic/nonionic surfactant mixture. Although some deviations exist, the adhesion of particle to fabric generally increased with decreasing its removal from fabric. The detergency of particulate soil on PET fabric was relatively higher in anionic/nonionic surfactant mixed solution than in each single surfactant solution, but the influence of ratio of anionic/nonionic surfactant mixture on detergency of particulate soil was low. Generally the detergency of particulate soil on fabric was at its maximum at 0.1% surfactant concentration, $1{\times}10^{-3}$ ionic strength, $Na_5P_3O_{10}$ electrolytes and 10 mole numbers of oxyethylene ether of nonionic surfactant, regardless of ratio of anionic/nonionic surfactant mixture.

Electric Field Analysis and Removal Characteristics of Escherichia Coli for Water Discharge Tube with Globular SiO$_2$ (구형 SiO$_2$를 갖는 수방전관의 전계 해석 및 대장균 제거 특성)

  • 이동훈
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.103-108
    • /
    • 2004
  • This paper shows the simulation of electric field distribution and removal characteristics of Escherichia coli for water discharge tube with globular $SiO_2$. At the experiments of the removing Escherichia coli used the discharge tube with globular dielectric($SiO_2$), because the electric field is increased when applied voltage is increased, the removed ratio of Escherichia coli was related with increasing of applied voltage. When a passing number of test water in water discharge tube is increased, the removed ratio of Escherichia coli is increased because passing number of territory with electric field is increased. When diameter of globular dielectric($SiO_2$) is increased, the removed time of Escherichia coli was decreased because electric field for dielectric polarization of globular dielectric($SiO_2$) was increased. Also, the removed ratio of Escherichia coli of the water discharge tube with globular dielectric($SiO_2$) was measured higher than the removal ratio of the discharge tube without globular dielectric($SiO_2$)

A study on the denitrification and microbial community characteristics by the change of C/N ratio of molasses and nitrate nitrogen (당밀과 질산성 질소의 C/N ratio 변화에 따른 탈질 및 미생물 군집 특성에 관한 연구)

  • Eom, Hanki;Kim, Sungchul
    • Korean Journal of Microbiology
    • /
    • v.54 no.2
    • /
    • pp.105-112
    • /
    • 2018
  • To compare the denitrification efficiency, this study used molasses and methanol were used as external carbon sources. Specific experimental conditions were classified according to C/N ratio conditions. The batch test showed that the denitrification efficiency increased as C/N ratios of molasses and methanol rose. The most suitable C/N ratio of molasses turned out 4:1 considering the concentration of the residue chemical oxygen demand (COD) and the denitrification efficiency, which was 91.4%. Specific denitrification rate (SDNR) drawn as a kinetic factor demonstrated that molasses and methanol showed similar SDNR values as C/N ratios of molasses and methanol increased. Under the condition of C/N ratio 4:1, 0.0292 g $NO_3{^-}-N$ removal/g mixed liquor volatile suspended solid (MLVSS)/day (molasses), 0.0299 g $NO_3{^-}-N$ removal/g MLVSS/day (methanol) were found. Sludge adapted to molasses showed that Bacterium Pseudomonas sp. and Bergeylla sp. dominated through an analysis of microbial community. In addition, some bacteria were high convergences than the variety of microbial community. Accordingly, it was assumed that molasses focus on growing microorganisms specialized in denitrification and applied as a replaceable external carbon source that can enhance denitrification performance.