• Title/Summary/Keyword: Remote Diagnosis

Search Result 247, Processing Time 0.022 seconds

An Interview Survey for Developing Clinical Trial Protocol on Individualized Acupuncture Treatment for Knee Osteoarthritis (퇴행성 슬관절염의 맞춤형 침구 임상시험 프로토콜 개발을 위한 면접조사)

  • Lee, Sang-Hoon;Seo, Byung-Kwan;Seo, Jung-Chul;Lee, Seung-Deok;Kim, Sun-Woong;Choi, Sun-Mi;Kim, Yong-Suk
    • Journal of Acupuncture Research
    • /
    • v.22 no.6
    • /
    • pp.189-199
    • /
    • 2005
  • Objectives : This interview survey was carried out to identify how Korean medical doctors make acupuncture prescriptions for knee osteoarthritis in clinics. Methods : Survey questions were developed based on a consensus of acupuncture professors at Kyung Hee University, Dongguk University, Daegu Haany University. The interviews were conducted to 72 members of the Korea Oriental Medical Association who answered to prefer remote acupuncture prescription at previous telephone survey. Results : Korean medical doctors prefer to use five shu acupuncture points, especially 'hyung' or , 'shu' points, on the contralateral side of lesion and that the first target organ is liver. Five element points theory was mainly based on 'Nanjing' and 'Hwangdi Neijing'. The De-qi sensation of both doctor and patients was emphasized. Diagnosis and evaluation generally depend on subjective evaluation rather than objective scale. Conclusion : This study showed that Koran medical doctors prefer to follow the Korean traditional acupuncture methods respecting the old classic principles. And these results can guide us to develop advanced clinical trial protocols more close to our acupuncture practice.

  • PDF

Development of Ship′s Digital ECG and Stethoscope Based on PC (PC를 기반으로 한 선박용 디지털 심전도 및 청진기 개발)

  • Lee, Geun-Sil;Moon, Serng-Bae
    • Journal of Navigation and Port Research
    • /
    • v.28 no.3
    • /
    • pp.239-245
    • /
    • 2004
  • Electrocardiogram and phonocardiogram acquired from ECG and stethoscope by a non-invasive method are bio-signals which laue been a great role in patients diagnosis and used extensively by doctors. And these are mainly used at the examination room or first-and room of hospital. When the patients are located at some places far away from hospital like a car, an airplane and a vessel under way, there are some difficulties in confirming their cardiac sound Especially the patient of ocean going vessel might not have a medical treatment from the professional doctor at times. In this paper, we developed the digital ECG and stethoscope system based on personal computer which can easily measure the patient's cardiac sound and ECG signal, and this might shorten the appearance of the remote maritime telemedicine.

Study on Wireless Acquisition of Vibration Signals (진동신호 무선 수집에 대한 연구)

  • Lee, Sunpyo
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.254-258
    • /
    • 2018
  • A Wi-Fi signal network (WSN) system is introduced in this paper. This system consists of several data-transmitting sensor modules and a data-receiving server. Each sensor module and the server contain a unique intranet IP address. A piezoelectric accelerometer with a bandwidth of 12 kHz, a 24-bit analog-digital converter with a sampling rate of 15.625 kS/s, a 32-bit microprocessor unit, and a 1-Mbps Wi-Fi module are used in the data-transmitting sensor module. A 300-Mbps router and a PC are used in the server. The system is verified using an accelerometer calibrator. The voltage output from the sensor is converted into 24-bit digital data and transmitted via the Wi-Fi module. These data are received by a Wi-Fi router connected to a PC. The input frequencies of the accelerometer calibrator (320 Hz, 640 Hz, and 1280 Hz) are used in the data transfer verification. The received data are compared to the data retrieved directly from the analog-to-digital converter used in the sensor module. The comparison shows that the developed system represents the original data considerably well. Theoretically, the system can acquire vibration signals from 600 sensor modules at an accelerometer bandwidth of 15.625 kHz. However, delay exists owing to software processes, multiplexing between sensor modules, and the use of non-real time operating system. Hence, it is recommended that this system may be used to acquire vibration signals with up to 10 kHz, which is approximately 70% of the theoretical maximum speed of the system. The system can be upgraded using parts with higher performance

Policy-Based Emergency Bio Data Transmission Architecture for Smart Healthcare Service (스마트 헬스케어 서비스를 위한 정책기반 응급 생체 데이터 전송 구조)

  • Chun, Seung-Man;Nah, Jae-Wook;Lee, Ki-Chun;Park, Jong-Tae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.10
    • /
    • pp.43-52
    • /
    • 2011
  • In this paper, we propose the architecture of the policy-based emergency bio data transmission for the smart healthcare service. the medical staff can quickly and accurately monitor the emergency bio data of the remote patient through the proposed architecture. The proposed system consists of three parts: IEEE 11073-based agents and managers performing the aggregation function and transmission function of the bio data; the emergency management server performing the converting function between IEEE 11073 and HL7 and auto-diagnosis function of the policy-based; HL7 medical system based on HL7. Finally, by implementing the proposed system, we shows that the aggregation of the bio data and management of the emergency bio data in the smart healthcare service are possible.

Cancer Care Management through a Mobile Phone Health Approach: Key Considerations

  • Mohammadzadeh, Niloofar;Safdari, Reza;Rahimi, Azin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.4961-4964
    • /
    • 2013
  • Greater use of mobile phone devices seems inevitable because the health industry and cancer care are facing challenges such as resource constraints, rising care costs, the need for immediate access to healthcare data of types such as audio video texts for early detection and treatment of patients and increasing remote aids in telemedicine. Physicians, in order to study the causes of cancer, detect cancer earlier, act in prevention measures, determine the effectiveness of treatment and specify the reasons for the treatment ineffectiveness, need to access accurate, comprehensive and timely cancer data. Mobile devices provide opportunities and can play an important role in consulting, diagnosis, treatment, and quick access to health information. There easy carriage make them perfect tools for healthcare providers in cancer care management. Key factors in cancer care management systems through a mobile phone health approach must be considered such as human resources, confidentiality and privacy, legal and ethical issues, appropriate ICT and provider infrastructure and costs in general aspects and interoperability, human relationships, types of mobile devices and telecommunication related points in specific aspects. The successful implementation of mobile-based systems in cancer care management will constantly face many challenges. Hence, in applying mobile cancer care, involvement of users and considering their needs in all phases of project, providing adequate bandwidth, preparation of standard tools that provide maximum mobility and flexibility for users, decreasing obstacles to interrupt network communications, and using suitable communication protocols are essential. It is obvious that identifying and reducing barriers and strengthening the positive points will have a significant role in appropriate planning and promoting the achievements of mobile cancer care systems. The aim of this article is to explain key points which should be considered in designing appropriate mobile health systems in cancer care as an approach for improving cancer care management.

A Study on the Implementation of the Healthcare Device and the Telemedicine System using ZigBee (ZigBee를 활용한 헬스케어 장치 및 원격 의료 서비스 시스템 구현에 관한 연구)

  • Cho, Sung-Min;Kang, Sung-In;Kim, Gwan-Hyung;Choi, Sung-Wook;Kwon, Oh-Hyun;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.469-472
    • /
    • 2007
  • The telemedicine system provide an efficient means to monitor the status of health and measure bio-information even though the limitation of distance and time. The telemedicine system can be divided into two categories. The first one is Remote Support Service which can monitor the patient including home environments and give those diagnosis information to medical office. and the other one is Alarm Service that can be used for tile emergency status. For the convenience of the patient we will design and implement portable healthcare device and the telemedicine system under the wireless ZigBee network environments.

  • PDF

A Centralized Monitoring System for Infant Incubators Using Bluetooth (블루투스를 이용한 신생아 인공 보육기의 중앙감시 장치)

  • Kim Joo-Sik;Ahn Hyun-Sik;Jeong Gu-Min
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.1
    • /
    • pp.33-37
    • /
    • 2006
  • In this paper, we present a centralized monitoring system for infant incubator using Bluetooth. Conventional monitoring systems for incubators require large space and wire connection, which causes the spatial restrictions. To overcome this disadvantage, centralized monitoring system is proposed for infant incubators using Bluetooth. The implemented system consists mainly of transmission systems and receiver systems. There are temperature sensors, humidity sensors, ECG measurement units and Bluetooth modules in the transmission systems. For temperature, humidity and ECG data, the transmission systems acquire them from the measuring modules in the incubator and transmits the signals using Bluetooth. In the receiver system, users can see the status of the infant by accessing the central monitoring host computer. That is, one can monitor the information on the temperature and the humidity in the incubator and Infant's ECG without dependence to a conventional bulky system. Also, the system manager in the receiver system can maintain centralized monitoring of the situations in all incubators and infant. The developed system will be useful in remote diagnosis of infant incubator In various environments.

  • PDF

The intelligent solar power monitoring system based on Smart Phone (스마트폰 기반의 지능형 태양광 전력적산 모니터링 시스템에 관한 연구)

  • Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1949-1954
    • /
    • 2016
  • Smart grid technology can be called grid techniques to improve the efficiency of the electric power by exchanging bidirectional information of electric power with real-time between electric power suppliers and consumers. Recently, the solar power generation system is being applied actively. However the solar power system has several problems leading to reduce overall electricity generation, because the difficult of the diagnosis and the solar power system failure such as PV(PhotoVoltaics) and inverter. In order to build an efficient smart grid, a stable electric power energy requirements capture and management and early fault detection is essentially required in solar power generation system. In this paper, it is designed to monitor the operating status of the solar power monitoring system from a remote location through a RS-485 or TCP/IP communication module to monitoring the output of solar power energy and abnormal phenomenon, to developing the measurement module and to transfer measured data.

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Bae, Suk-Myong;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.499-502
    • /
    • 2009
  • Supply of electric power and electricity safety for whole system and network are essential element. Electricity safety technology need rating for product and research about certification as product development that is done cotton flannel mixed with development of u-IT technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication and module for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in PD, Arc detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

  • PDF

Development of the Ice Machine Condition Monitoring System for Remote Diagnosis (원격진단을 위한 제빙기 상태 모니터링 시스템 개발)

  • Kim, Su-hong;Jeong, Jong-mun;Jung, Jin-uk;Jin, Kyo-hong;Hwang, Min-tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.230-233
    • /
    • 2016
  • In this paper, we developed the ice machine conditions monitoring system that confirms conditions of the ice machine. The developed system is composed of Communication Board, Server Program, and Web-based User Application. Communication Board which is connected to the ice machine periodically sends various data, such as current, voltage, the refrigerant pressure and temperature, the external temperature and humidity. Server Program stores the data received from Communication Board into database. The manager or the ice machine operator can see the state of the own machine through User Application based on Web. When a symptom is detected on the ice machine, the manager and the operator can checks the current condition of the ice machine by using the data obtained in real time and also prevents the machine troubles by taking proper actions.

  • PDF