• Title/Summary/Keyword: Reliable control

Search Result 1,917, Processing Time 0.034 seconds

Study on the Development of Measuring System for Fermentation Degree of Liquid Swine Manure Using Visible Ray (가시광선을 이용한 돈분뇨 액비 부숙도 측정장치 개발에 관한 연구)

  • Choi, D.Y.;Kwag, J.H.;Park, K.H.;Song, J.I.;Kim, J.H.;Kang, H.S.;Han, C.B.;Choi, S.W.;Lee, C.S.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.227-236
    • /
    • 2010
  • This study was conducted to develop an measuring system and method for fermentation degree of liquid swine manure by visible ray. The constituent changes of liquid swine manure were examined. pH gradually increased with time, but EC gradually decreased. Malodor strength decreased gradually with aeration treatment with time. Control needed more time to decrease malodor strength than aeration treatment. In aeration treatment, there was no germination of seeds (radish, chinese cabbage) up to 6 weeks and germination rate at 15th week was over 50%. However, in control, there was no germination up to end of experiment. Circular chromatography method showed that there was change after 10th week in aeration treatment but there was no change up to end of experiment in control. As a result, the fermentation degree of liquid swine manure would have relations among pH, EC, germination rate, malodor concentration, and reaction of circular chromatography. The simple analytical instrument for liquid swine manure consisted of a tungsten halogen and deuterium lamp for light source, a sample holder, a quartz cell, spectrometer for spectrum analyzer, a malodour measuring device, a software, etc. Results showed that the simple analytical instrument that was developed can approximately predict the fermentation degree of liquid swine manure by visible ray. Generally, the experiment proved that the simple analytical instrument was reliable, feasible and practical for analyzing the fermentation degree of liquid swine manure.

Determination of Color Value (L, a, b) in Green Tea Using Near-Infrared Reflectance Spectroscopy (근적외 분광분석법을 이용한 녹차의 색도 분석)

  • Lee, Min-Seuk;Choung, Myoung-Gun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.spc
    • /
    • pp.108-114
    • /
    • 2008
  • Near infrared spectroscopy (NIRS) is a rapid and accurate analytical method for determining the composition of agricultural products and feeds. The applicability of near infrared reflectance spectroscopic method was tested to determine the color value (L, a, b) of green tea. A total of 162 green tea calibration samples and 82 validation samples were used for NIRS equation development and validation, respectively. In the developed NIRS equation for analysis of the color value (L, a, b), the most accurate equation for L value was obtained at 2, 8, 6, 1 (2nd derivative, 8 nm gap, 6 points smoothing, and 1pointsecond smoothing), and for a, and b value were obtained at 1, 4, 4, 1 (1st derivative, 4 nm gap, 4points smoothing, and 1 point second smoothing) math treatment condition with SNVD (Standard Normal Variate and Detrend) scatter correction method and entire spectrum ($400{\sim}2,500\;nm$) by using MPLS (Modified Partial Least Squares) regression. Validation results of these NIRS equations showed very low bias (L: 0.005%, a: 0.003%, b: -0.013%) and standard error of prediction (SEP, L: 0.361%, a: 0.141%, b: 0.306%) as well as high coefficient of determination ($R^2$, L: 0.905, a: 0.986, b: 0.931). Therefore, these NIRS equations can be applicable and reliable for determination of color value (L, a, b) of green tea, and NIRS method could be used as a mass screening technique for breeding programs and quality control in the green tea industry.

Influences of Nutrient Deficiency on the Phytoplankton Community in Pal'tang Reservoir (몇가지 영양염 결핍이 팔당댐의 식물플랑크톤군집에 미치는 영향)

  • Kim, Baik-Ho;Choi, Ji-Young;Hwang, Soon-Jin;Han, Myung-Soo
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.1 s.106
    • /
    • pp.47-56
    • /
    • 2004
  • To understand the effect of nutrient deficiency on the plankton community in three stations with different water qualities in Pal'tang Reservoir, Korea, phytoplanktons(> 10 ${\mu}m$) were cultured in nutrient enrichment Allen's media (AM) and nutrient-deficient Allen's media. A distinct shift in the species composition and biomass of phytoplankton (as chlorophyll- a) showed in all treatments. In particular, it was very interesting that the new development of cyanobacterium Microcystis aeruginosa occurred by the Fe-deficient AM. Except for Si, a community growth (as chlorophyll- a) was inhibited in all nutrient deficient treatments. Species diversity after nutrient deficiency was changed to below 2.0; slightly increased in N and P-deficiency, while decreased in Si and Fe, respectively. As suggested, dominance was entirely opposite to diversity. Therefore, the nutrient deficient effectively induced the succession of species and biomass, phytoplankton community, suggesting a possibility as a reliable tool to control the algal bloom in eutrophic lakes and reservoirs.

An Empirical Validation Study for Calibration Verification in TDM Test (검량보정 검증의 실험적 적합성에 대한 연구 -치료적 약물검사를 중심으로-)

  • Chang, Sang-Wu;Kim, Nam-Yong;Choi, Ho-Sung;Park, Yong-Won;Chu, Gyung-Bok;Yun, Keun-Young;Park, Byung-Ok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • The purpose of this study was to verify (i) a consistent calibration verification for the assessment of method linearity and (ii) calibration agreement with calibration settings. We validated calibration verification through method linearity with different lot number of individual calibrators that span the working range for 9 tests except salicylate with control sample in test. We evaluated that it covered broad analyte range to assay from near zero to the top of the measuring range with 5 or 6 points every three times for 10 analytes in TDM test. Target values were plotted on X-axis with assigned or observed values on the Y-axis. Working range were as follows. Calibration verification of the measuring range (maximum to minimum values) has been validated asetaminophen 0.1 to $304.6_{\mu}g/mL$, salicylate 0 to $1005_{\mu}g/mL$, valproic acid 3.2 to $154.19_{\mu}g/mL$, digoxin 0.17 to 5.65 ng/mL, vancomycine 1.3 to $80.51_{\mu}g/mL$, carbarmazepine 0.1 to $22.3_{\mu}g/mL$, phenytonin 0.6 to $40.21_{\mu}g/mL$, theophyline 0.2 to $40.21_{\mu}g/mL$, primidone 0 to $24.07_{\mu}g/mL$, phenobarbital 0.6 to $60.0_{\mu}g/mL$. Drawing a straight line through five or six points of these data showed good linearity. We are sure that it is important to assess the calibration verification of a test method to ascertain the lowest and highest test results that are reliable.

  • PDF

Study for Reducing Safety Distance by Installing Ammunition Storage Facility in Underground (탄약저장시설 지하화에 따른 안전거리 축소방안 연구)

  • Park, Sangwoo;Jun, Jonghoon;Choi, Hangseok;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.253-260
    • /
    • 2020
  • With increasing interest in an underground-type ammunition storage facility, several design results have been provided recently. However, since not only experts in the tunnel but also military persons in charge of ammunition have not fully understood the safety distance standard, reliable design results are not being produced. In this study, the effective design method of an underground-type ammunition storage facility was provided by analyzing the current safety distance standard. First, the critical safety distances that dominate the size of construction site for underground-type ammunition storage facilities were evaluated, which are the layout of chambers and the configuration of the entrances. Then, the decreasing effect of inter-chamber distance was studied according to the rock type and the storage density of ammunition. In addition, the method of designing tunnels with parallel lines and two-floors was considered for arranging more chambers while complying with the safety distance standards. In particular, numerical simulations were carried out to determine the satisfaction of the safety distance standards when an underground-type ammunition storage facility is composed of two-floor and the decreasing effect of inter-chamber distance according to the inner explosive pressure reduction. Finally, the method to adjust the size of entrances and the path of pressure were studied for decreasing the safety distance at the entrance.

Design and simulation of hydraulic system for launch vehicle holding device (우주발사체 지상고정장치 유압시스템 설계 및 해석)

  • Kim, Dae Rae;Yang, Seong Pil;Lee, Jaejun;Kim, Bum Suk;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1087-1094
    • /
    • 2016
  • The responsibility of the vehicle holding device (VHD) is to hold the launch vehicle while it is stayed on launch pad and release the holding mechanism to allow a lift-off of launch vehicle at a moment of lift-off. During a release of the holding mechanism, in order to prevent the Ka doing a doing a doing mode which is vertical oscillation of entire liquid propellant and very severe for vehicle structure, gradual release of holding force is required. Also, a release operation of all 4 VHD should be synchronized very precisely. In this study, to comply the "gradual release and synchronized operation requirement", concept of VHD hydraulic system using an accumulator, pyro valve and orifice to control speed of hydraulic cylinder is proposed instead of using complicated hydraulic components. Then through multi-body dynamic analysis and computational hydraulic analysis, a size of orifice to meet a target speed of hydraulic cylinder is calculated. Through this study, simple and reliable VHD hydraulic system complying requirements is designed.

Application of Computer-Aided Diagnosis for the Differential Diagnosis of Fatty Liver in Computed Tomography Image (전산화단층촬영 영상에서 지방간의 감별진단을 위한 컴퓨터보조진단의 응용)

  • Park, Hyong-Hu;Lee, Jin-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.443-450
    • /
    • 2016
  • In this study, we are using a computer tomography image of the abdomen, as an experimental linear research for the image of the fatty liver patients texture features analysis and computer-aided diagnosis system of implementation using the ROC curve analysis, from the computer tomography image. We tried to provide an objective and reliable diagnostic information of fatty liver to the doctor. Experiments are usually a fatty liver, via the wavelet transform of the abdominal computed tomography images are configured with the experimental image section, shows the results of statistical analysis on six parameters indicating a feature value of the texture. As a result, the entropy, average luminance, strain rate is shown a relatively high recognition rate of 90% or more, the control also, flatness, uniformity showed relatively low recognition rate of about 70%. ROC curve analysis of six parameters are all shown to 0.900 (p = 0.0001) or more, showed meaningful results in the recognition of the disease. Also, to determine the cut-off value for the prediction of disease six parameters. These results are applicable from future abdominal computed tomography images as a preliminary diagnostic article of diseases automatic detection and eventual diagnosis.

Designing fuzzy systems for optimal parameters of TMDs to reduce seismic response of tall buildings

  • Ramezani, Meysam;Bathaei, Akbar;Zahrai, Seyed Mehdi
    • Smart Structures and Systems
    • /
    • v.20 no.1
    • /
    • pp.61-74
    • /
    • 2017
  • One of the most reliable and simplest tools for structural vibration control in civil engineering is Tuned Mass Damper, TMD. Provided that the frequency and damping parameters of these dampers are tuned appropriately, they can reduce the vibrations of the structure through their generated inertia forces, as they vibrate continuously. To achieve the optimal parameters of TMD, many different methods have been provided so far. In old approaches, some formulas have been offered based on simplifying models and their applied loadings while novel procedures need to model structures completely in order to obtain TMD parameters. In this paper, with regard to the nonlinear decision-making of fuzzy systems and their enough ability to cope with different unreliability, a method is proposed. Furthermore, by taking advantage of both old and new methods a fuzzy system is designed to be operational and reduce uncertainties related to models and applied loads. To design fuzzy system, it is required to gain data on structures and optimum parameters of TMDs corresponding to these structures. This information is obtained through modeling MDOF systems with various numbers of stories subjected to far and near field earthquakes. The design of the fuzzy systems is performed by three methods: look-up table, the data space grid-partitioning, and clustering. After that, rule weights of Mamdani fuzzy system using the look-up table are optimized through genetic algorithm and rule weights of Sugeno fuzzy system designed based on grid-partitioning methods and clustering data are optimized through ANFIS (Adaptive Neuro-Fuzzy Inference System). By comparing these methods, it is observed that the fuzzy system technique based on data clustering has an efficient function to predict the optimal parameters of TMDs. In this method, average of errors in estimating frequency and damping ratio is close to zero. Also, standard deviation of frequency errors and damping ratio errors decrease by 78% and 4.1% respectively in comparison with the look-up table method. While, this reductions compared to the grid partitioning method are 2.2% and 1.8% respectively. In this research, TMD parameters are estimated for a 15-degree of freedom structure based on designed fuzzy system and are compared to parameters obtained from the genetic algorithm and empirical relations. The progress up to 1.9% and 2% under far-field earthquakes and 0.4% and 2.2% under near-field earthquakes is obtained in decreasing respectively roof maximum displacement and its RMS ratio through fuzzy system method compared to those obtained by empirical relations.

Simultaneous determination of illegal galactagogue adulterants in supplement diets by LC-MS/MS

  • Lee, Ji Hyun;Cho, So-Hyun;Park, Han Na;Park, Hyoung Joon;Kim, Nam Sook;Park, Sung Kwan;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.171-178
    • /
    • 2018
  • Recently, for successful lactation, many breastfeeding mothers seek various products, including herbal medicine, dietary supplements, and prescribed medicines, to improve milk production. As demand for galactogogues grows, it is highly possible that pharmaceutical galactogogues may be adulterated with illegal products to maximize their efficacy. For continuous control and supervision of illegal products, we developed and validated a simple and sensitive LC-MS/MS method capable of simultaneously determining five galactogogues. Chromatographic separation was conducted using an Agilent Poroshell $120SB-C_{18}$ column with a mobile phase consisting of 20 mM ammonium formate (pH 5.4) and 100 % acetonitrile. The total run time was 13 min per analyte. The proposed method was performed according to the guidelines of the International Conference of Harmonization and it produced reliable results. This method showed high sensitivity and specificity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 0.01-0.82 ng/mL and 0.02-2.45 ng/mL, respectively, for the solid- and liquid-type samples. Specificity was evaluated by analyzing matrix-blank samples spiked with the target compounds at LOQ levels, which provided a good separation of all peaks without interference. Additionally, the repeatability and intermediate precision were typically <15 %, whereas the recovery was 80-120 % of the values obtained using blank samples. Thus, we concluded that this method could be used for the identification and quantification of galactogogues in food or herbal products.

SURFACE CHARACTERISTICS AND BIOLOGICAL RESPONSES OF HYDROXYAPATITE COATING ON TITANIUM BY HYDROTHERMAL METHOD: AN IN VITRO STUDY

  • Kim, Dong-Seok;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.363-378
    • /
    • 2005
  • Statement of problem. Hydroxyapatite(HA) coated titanium surfaces have not yet showed the reliable osseointegration in various conditions. Purpose. This study was aimed to investigate microstructures, chemical composition, and surface roughness of the surface coated by the hydrothermal method and to evaluate the effect of hydrothermal coating on the cell attachment, as well as cell proliferation. Material and Methods. Commercially pure(c.p.) titanium discs were used as substrates. The HA coating on c.p. titanium discs by hydrothermal method was performed in 0.12M HCl solution mixed with HA(group I) and 0.1M NaOH solution mixed with HA(group II). GroupⅠ was heated at 180 $^{\circ}C$ for 24, 48, and 72 hours. GroupⅡ was heated at 180 $^{\circ}C$ for 12, 24, and 36 hours. And the treated surfaces were evaluated by Scanning electron microscopy(SEM), Energy dispersive X-ray spectroscopy(EDS), X-ray photoelectron spectroscopy(XPS), X-ray diffraction method(XRD), Confocal laser scanning microscopy(CLSM). And SEM of fibroblast and 3-(4,5- dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide(MTT) assay were used for cellular responses of the treated surfaces. Results. The color of surface changed in both groups after the hydrothermal process. SEM images showed that coating pattern was homogeneous in group II, while inhomogeneous in group I. H72 had rosette-like precipitates. The crystalline structure grew gradually in group II, according to extending treatment period. The long needle-like crystals were prominent in N36. Calcium(Ca) and phosphorus(P) were not detected in H24 and H48 in EDS. In all specimens of group II and H72, Ca was found. Ca and P were identified in all treated groups through the analysis of XPS, but they were amorphous. Surface roughness did not increase in both groups after hydrothermal treatment. The values of surface roughness were not significantly different between groups I and II. According to the SEM images of fibroblasts, cell attachments were oriented and spread well in both treated groups, while they were not in the control group. However, no substantial amount of difference was found between groups I and II. Conclusions. In this study during the hydrothermal process procedure, coating characteristics, including the HA precipitates, crystal growth, and crystalline phases, were more satisfactory in NaOH treated group than in HCl treated group. Still, the biological responses of the modified surface by this method were not fully understood for the two tested groups did not differ significantly. Therefore, more continuous research on the relationship between the surface features and cellular responses seems to be in need.