• Title/Summary/Keyword: Reliability test

Search Result 6,705, Processing Time 0.035 seconds

Reliability Assessment of Polymer Insulators by Accelerated Aging Test (가속열화시험에 의한 폴리머애자의 신뢰성 평가)

  • Han, Jae-Hong;Lee, Byung-Sung;Jung, Jong-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.10-14
    • /
    • 2001
  • In order to assess the long-tenn reliability of polymer insulators for distribution power systems, we have developed the accelerated aging test method which can simulate the operation conditions. In this study, 3000 hours aging test for 4 kinds of polymer insulators has been completed by the developed accelerated aging test. After 3000 hours aging test, visual inspection and electrical tests were carried for identifying a change of characteristics. Some specimens showed the surface erosion and the manufacturing defect. In the electrical tests, the wet flashover voltage was significant1y decreased by the accelerated aging test. In comparison with the field-aged polymer insulators, it can be concluded that the developed test method can evaluate the long-tenn reliability within short time and screen the manufacturing defect.

  • PDF

A Study on an Evaluation of Software Reliability with Test (테스트 단계를 고려한 소프트웨어 신뢰성 평가에 관한 연구)

  • 유창열;권대고
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.2
    • /
    • pp.1-6
    • /
    • 1998
  • The evaluation of reliability is very important in the development process of software. There may be lack of trustfulness on the results that come from the analysis and evaluation of reliability of softwares which do not divide the test phases. At this point, this article studies how to evaluate the reliability dividing the test phases in order to settle the these problems. In doing so, I apply the fault data to be found in Unit Test, Integration Test, Validation Test and System Test to SRGM(Software Reliability Growth Model), Exponential SRGM, Delayed S-shaped SRGM and Inflection S-shaped SRGM. The result is that Inflection S-shaped is best suitable with Unit Test Delayed S-shaped is best suitable with Integration and Validation Test, and Exponential SRGM is best suitable with System test. In this respect, I can show that the results of this study on parameter estimation, difference square summation, number of fault remained is superior to the established methods.

  • PDF

Development of Accelerated Life Test Method for UHF RFID Tags for Medicine Supply Management (의약품 유통 관리용으로 사용되는 UHF 대역 RFID Tag의 가속수명시험법 개발)

  • Yang, Il Young;Yu, Sang Woo;Park, Jung Won;Joe, Won-Seo
    • Journal of Applied Reliability
    • /
    • v.14 no.2
    • /
    • pp.93-96
    • /
    • 2014
  • RFID (Radio Frequency IDentification) system is recognition technology which can maintain various object's information. Reliability of RFID tags is the most important factor in RFID system. In this paper, we proposed ALT (Accelerated Life Test) method for UHF RFID tags. Temperature and humidity were adopted as stress factors and the accelerated life tests were conducted in three different conditions. We performed failure analysis for identifying failure mechanism and statistical analysis of test data. In the statistical analysis, we employed Inverse Power law for relationship between tag's life and stress. Through the statistical analysis, we proposed acceleration factor for several levels of temperature-humidity. The reliability qualification test plans were also designed for the tag's target reliability.

An Accelerated Life Test of LED Lights for Aviation Taxiway (항공유도로등화용 LED 광원의 가속수명시험)

  • Min, Kyong-Chan;Yun, Yang-Gi;Kim, Myung-Soo
    • Journal of Applied Reliability
    • /
    • v.11 no.2
    • /
    • pp.127-140
    • /
    • 2011
  • This paper presents an accelerated life test of aviation taxiway lights installed in the airport to help safe navigation of airplanes at night or in bad weather. Recently halogen lamps of taxiway lights are replaced by LED ones and their reliability needs yet to be verified. Thus, effective test conditions are designed reflecting the failure modes and mechanisms from the previous studies on LED, which include the accelerated degradation process. The test is performed under the temperature $70^{\circ}C$ and $90^{\circ}C$ for two types of LED lights, taxiway center line lights(TCLL) and taxiway edge lights (TEDL). The failure time data were analyzed using lognormal distribution and Arrhenius model to find the life-stress relationship, acceleration factor and life characteristics under the normal condition temperature $30^{\circ}C$.

Development of a Web-based Analysis Program for Reliability Assessment of Machine Tools (공작 기계의 신뢰성 평가를 위한 웹 기반 해석 프로그램 개발)

  • 강태한;김봉석;이수훈;송준엽;강재훈
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.369-374
    • /
    • 2004
  • Web-based analysis programs for reliability assessment of machine tools were developed in this study. First, the reliability data analysis program was developed to search for failure rate using failure data and reliability test data of mechanical part. Second, failure mode analysis was developed through performance tests like circular movement test vibration test for machine tools. This analysis program shows correlation between failure mode and performance test result. Third, tool life was predicted by correlation between flank wear and cutting time, using the extended Taylor tool life equation in turning data and the equivalently converted equation in order to apply ball endmill data to Taylor tool life equation in milling data. All the information related to input and result data can be stored in theses programs.

  • PDF

A Study on Track Drive Unit Test and Evaluation for Mini Excavators (소형 굴삭기의 주행구동유니트 시험평가에 관한 연구)

  • Lee, Gi-Chun;Lee, Young-Bum;Choi, Byung Oh
    • Journal of Applied Reliability
    • /
    • v.15 no.3
    • /
    • pp.139-144
    • /
    • 2015
  • Track drive unit adopted in the small sized excavator generally have been used in the construction equipment under the 10 tons as the driving device with forwarding and reversing of excavator. It is required to study the accelerated life test applied by over torque and speed to test the durability life test reflected the many driving modes of small sized excavator and also need to equip the comprehensive performance and life test equipments to do the various performance tests. This study had analyzed the failure modes of the components, and calculated the equivalent loads investigated the used loads in the real field conditions and elicits the acceleration factor adopted in the inverse power model. Also, this study have considered the changes of the acceleration factor and the durability test time in the case of the rotary group and the bearing through analyzing the main failure modes. It was calculated the no failure test time about 2 samples and confidence level 90% and elicited the accelerated life time 720 hours.

HALT of High Power Amplifier Module Used in Radar (레이더용 고출력 증폭기 모듈의 HALT)

  • Hwang, Soon-Mi;Kim, Chul-Hee;Lee, Kwan-Hun
    • Journal of Applied Reliability
    • /
    • v.14 no.2
    • /
    • pp.97-102
    • /
    • 2014
  • Radar is an object-detection system that uses radio waves to determine the range, altitude, direction, or speed of objects. High power amplifier Module is the most critical part of the high-power radar transmitter systems. It can be used to detect aircraft, ships, spacecraft, guided missiles, motor vehicles, weather formations, and terrain. Research related to radar has been conducted in various fields according to improvement of the communication technology. But only performance-originated technology development has been dashed; study concerning environment duality and safety concerning reliability are still insufficient. In general, radar module is exposed to the outside, on the means of moving or fixed in a certain place. It should be guaranteed sufficient immunity for a variety of environmental stresses that can occur in the outdoor. HALT is a great process used for quickly finding failure mechanisms in a hardware design and product. By applying various kinds and extreme level of stresses, we can find the operating limits of products. In thesis, we conducted HALT test of the high power amplifier modules which used in military and automotive radar. After the test, we analyzed environmental weaknesses of high power amplifier modules using conventional construction data.

Development of Reliability Demonstration Test for Personal Blood Glucose Meters (개인용 혈당측정기의 신뢰성 보증시험 개발)

  • Kim, Gi-Young;Park, Ho-Joon;Park, Chan-Soo;Ham, Jung-Keol;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.13 no.4
    • /
    • pp.299-307
    • /
    • 2013
  • The value of blood sugar is measured by a personal blood glucose meter which consists of two parts: a glucose strip and a blood glucose meter. A personal blood glucose meter makes use of electric media which are composed of glucose oxidase and electron. This study is to propose a method of reliability demonstration test derived from field data analysis and FMEA(Failure Mode and Effect Analysis). Detailed Conditions for reliability demonstration test are selected from the comparison of various failure mechanisms. The most dominant failure mechanism is wear-out which is caused by strip insertion/extraction. The testing device that can reproduce the failure mechanism of strip insertion/extraction is made to conduct reliability demonstration test. Using the testing device, it is confirmed that target lifetime of selected devices is more than 2 years.

A study on the accelerated life test method of hose assemblies by applying Knockdown stress (녹다운 스트레스에 의한 유압호스 조립체의 가속수명시험에 대한 연구)

  • Ko, Jae-Myoung;Lee, Yong-Bum;Han, Sung-Geon;Yoo, Young-Chul;Kim, Hyoung-Eui
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.93-100
    • /
    • 2006
  • The failure of hydraulic hose assemblies is caused by the impulse pressure and repetitive motions of bending and stretching (flexing) used at high pressure pipe in the form of bursting Since it takes long time to observe the bursting for life analysis, we can reduce test time by the method of applying the Knockdown stress which is equivalent to 70% of initial bursting pressure on rubber hose assemblies with maintaining the failure mode equally In this study, after scale parameter, shape parameter, and acceleration factor by preforming the impulse pressure test until the hose bursts, and finally analyzed the accelerated life.

  • PDF

A Study on the Reliability Assesment of Solar Photovoltaic and Thermal Collector System (태양광열 시스템의 신뢰성 평가에 관한 연구)

  • Park, Tae-Kook;Bae, Seung-Hoon;Kim, Sang-Kyo;Kim, Seon-Min;Kim, Dae-Hwan;Eom, Hak-Yong;Lee, Keun-Hui
    • New & Renewable Energy
    • /
    • v.16 no.4
    • /
    • pp.49-64
    • /
    • 2020
  • Photovoltaic and Thermal collector (PV/T) systems are renewable energy devices that can produce electricity and heat energy simultaneously using solar panels and heat exchangers. Since PV/T systems are exposed to the outdoors, their reliability is affected by various environmental factors. This paper presents a reliability test for a PV/T system and evaluates the test results. The reliability assessment entails performance, environment, safety, and life tests. The factor that had the greatest influence on the life of the system was the hydraulic pressure applied to the heat exchanger. A test was conducted by repeatedly applying pressure to the PV/T system, and a reliability analysis was conducted based on the test results. As a result, the shape parameter (β) value of 5.6658 and the B10life 308,577 cycles at the lower 95% confidence interval were obtained.