• Title/Summary/Keyword: Relative sensitivity

Search Result 661, Processing Time 0.027 seconds

A Study on the Humidity-Sensitive Characteristics of $(Ba,Ca)TiO_3$ ($(Ba,Ca)TiO_3$의 감습특성에 관한 연구)

  • 이능헌;육재호;김용혁;이덕출
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1144-1151
    • /
    • 1994
  • The humidity-sensitive specimens-(BaS11T-S1xTCaS1xT)TiOS13T, x=0, 0.1, 0.2, 0.3, 0.4, 0.5-were fabricated by a solid-state reaction method which is easy in process control of microstructure and good in mass production, and their humidity-sensitive characteristics were examined. Ca inhibits grain growth and the open porosity increases with Ca substitution, and the specimens at x=0.5 show the best humidity sensitivity. Their humidity sensitivity is higher at the lower frequencies, and drift phenomenon in humidity sensitivity is exhibted with aging in the air, which disappears by a heat treatment. The electrical conduction with water adsorption is dominated by the ions, and the activation energy decreases with increasing relative humidity.

  • PDF

Sensitivity Analysis of Rockfill Parameters Influencing Crest Displacements of CFRD Subjected to Earthquake Loading (지진하중을 받는 필댐 정부변위에 영향을 미치는 입력물성에 대한 민감도 분석)

  • Ha, Ik-Soo;Shin, Dong-Hoon
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.351-357
    • /
    • 2006
  • In this study, quantitative sensitivity analysis on rockfill material influencing the dam crest displacement of Concrete-Faced Rockfill Dam(CFRD) subjected to earthquake loading was carried out. The purpose of this study is to indicate the most important input parameter and to show the quantitative variation of displacement at the crest of CFR type dam during earthquake loading with this input parameter. From the sensitivity analysis, it was found that the crest displacement of CFR type dam subjected to dynamic loading was absolutely affected by the shear modulus of rockfill material and the effect of friction angle of it was negligible. This relative difference of sensitivity was more outstanding in case of crest settlement than in case of crest horizontal displacement. Also, it was found that the extent of effect of shear modulus on the displacement at the crest of CFRD due to dynamic loading decreased as maximum amplitude of input acceleration increased.

  • PDF

Aberrant Expression of E-cadherin in Lung Tissues of Patients with Probable Lung Cancer

  • Yuan, Yu-Lin;Wang, Yu-Ming;Liu, Hua;Qin, Gui-Fang;Tang, Ai-Guo;Duan, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.10
    • /
    • pp.5149-5153
    • /
    • 2012
  • Introduction: This study assessed the relationship of E-cadherin mRNA and protein expression with the diagnosis of lung cancer with the aim of providing an auxiliary diagnostic method. Methods: Semi-quantitative nested RT-PCR and western blotting were applied to detect E-cadherin mRNA transcripts and protein, respectively, in 30 cases of diagnostic lung cancer, 30 cases of clinically suspected patients with lung cancer and 30 cases of other disease. Immunohistochemical staining was also used to detect E-cadherin. Results: Remarkably decreased levels of relative E-cadherin mRNA value and increased E-cadherin protein negativity were observed in probable lung cancer, when compared with possible lung cancer and others. With a threshold of 1.45, relative E-cadherin mRNA value showed a sensitivity of 90% and a specifity of 83% for the diagnosis of lung cancer. The combination of decreased relative E-cadherin mRNA value and negative E-cadherin protein increased the specificity and sensitivity. Conclusion: These data suggest that Chinese patients with diagnostic lung cancer have similar decreased levels of relative E-cadherin mRNA and E-cadherin protein value in the lung cancer tissues as in lung cancer patients in other countries. Measurement of relative E-cadherin mRNA and protein values in lung cancer tissues has potential for lung cancer diagnosis.

Micro-Machined Capacitive Linear Encoder with a Mechanical Guide (마이크로 머시닝으로 제작한 기계적 가이드를 갖는 정전용량 선형 인코더)

  • Kang, Daesil;Moon, Wonkyu
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.440-445
    • /
    • 2012
  • Contact-type Linear Encoder-like Capacitive Displacement Sensor (CLECDiS) is a novel displacement sensor which has wide measurable range with high resolution. The sensor, however, is very sensitive to relative rotational alignment between stator and mover of the sensor as well as its displacement. In addition to, there can be some disturbances in the relative rotational alignment, so some noises occur in the sensor's output signal by the disturbances. This negative effect of the high sensitivity may become larger as increasing sensitivity. Therefore, this negative effect of the high sensitivity has to be compensated and reduced to achieve nanometer resolution of the sensor. In this study, a new type capacitive linear encoder with a mechanical guide is presented to reduce the relative rotational alignment problem. The presented method is not only to reduce the alignment problem, but also to assemble the sensor to the stage conveniently. The method is based on a new type CLECDiS that has mechanical guide autonomously. In the presented sensor, when the device is fabricated by micro-machining, the guide-rail is also fabricated on the surface of the sensor. By the direct fabrication of the guide-rail with high precision micro-machining, errors of the guide-rail can be reduced significantly. In addition, a manual yaw alignment is not required to obtain large magnitude of the output signal after the assembly of the sensor and the stage. The sensor movement is going to follow the guide-rail automatically. The prototype sensor was fabricated using the presented method, and we verify the feasibility experimentally.

Comparison of Precision for Available Phosphate Measurement between Lancaster and Soiltek KA-1 Spectrophotometric Method (Lancaster 법과 Soiltek KA-1 분광광도계를 이용한 유효인산 측정법의 정밀도 비교)

  • Hyun, Hae-Nam;Lim, Han-Cheol;Eom, Ki-Cheol;Kim, Yoo-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.3
    • /
    • pp.268-273
    • /
    • 1999
  • To measure the precision of Soiltek$^{(R)}$ KA-1 spectrophotometric measurement of soil available phosphate, standard deviation, C;V, and relative sensitivity were investigated, comparing to Lancaster method. Available phosphate concentration measured by Soiltek$^{(R)}$ KA-1 spectrophotometric method was highly correlated with Lancaster method($r=0.998^{***}$) and the slop of regression equation was close to 1.0. There were no differences in standard deviation. CV, and relative sensitivity for soil available phosphate concentrations measured by two methods. Regarding to convenience of experimental procedure and instrumental operation, and time saving analysis, Soiltek$^{(R)}$ KA-1 spectrophotometric measurement for soil available phosphate is highly recommended.

  • PDF

RHODIUM SELF-POWERED NEUTRON DETECTOR'S LIFETIME FOR KOREAN STANDARD NUCLEAR POWER PLANTS

  • YOO CHOON SUNG;KIM BYOUNG CHUL;PARK JONG-HO;FERO ARNOLD H.;ANDERSON S. L.
    • Nuclear Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.605-610
    • /
    • 2005
  • A method to estimate the relative sensitivity of a self-powered rhodium detector for an upcoming cycle is developed by combining the rhodium depletion data from a nuclear design with the site measurement data. This method can be used both by nuclear power plant designers and by site staffs of Korean standard nuclear power plants for determining which rhodium detectors should be replaced during overhauls.

Formation and humidity-sensing properties of porous silicon oxide films by the electrochemical treatment (전기화학적 처리에 의한 다공질 실리콘 산화막의 형성과 감습 특성)

  • 최복길;민남기;류지호;성영권
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.1
    • /
    • pp.93-99
    • /
    • 1996
  • The formation properties and oxidation mechanism of electrochemically oxidized porous silicon(OPS) films have been studied. To examine the humidity-sensitive properties of OPS films, surface-type and bulk-type humidity sensors were fabricated. The oxidized thickness of porous silicon layer(PSL) increases with the charge supplied during electrochemical humidity sensor shows high sensitivity at high relative humidity in low temperature. The sensitivity and linearity can be improved by optimizing a porosity of PSL. (author). refs., figs.

  • PDF

Photon Energy Dependence of the Sensitivity of LiF TLDs Loaded with Thin Material (얇은 박막을 얹은 TLD 반응감도의 광자 에너지에 대한 의존성)

  • Min Byongim J;Kim Sookil;Loh John J.K;Cho Young Kap
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.256-260
    • /
    • 1999
  • Purpose : An investigation has been carried out on the factors which affect the response reading of thermoluminescent dosimeters (TLD-100) loaded with thin material in high energy Photon. The aim of the study was to assess the energy response of TLD-100 to the therapeutic ranges of photon beam. Materials and Methods : In this technique, TLD-100 (abbreviated as TLD) chips and three different thin material (Tin, Gold, and Tissue equivalent plastic plate) which mounted on the TLD chip were used in the clinical photon beam. The thickness of each metal plates was 0.1 mm and TE plastic plate was 1 mm thick. These compared with the photon energy dependence of the sensitivities of TLD (normal chip), TLD loaded with Tin or Gold plate, for the photon energy range 6 MV to 15 MV, which was of interest in radiotherapy. Results : The enhancement of surface dose in the TLD with metal plate was clearly detected. The TLD chips with a Gold plate was found to larger response by a factor of 1.83 in 10 MV photon beam with respect to normal chip. The sensitivity of TLD loaded with Tin was less than that for normal TLD and TLD loaded with Gold. The relative sensitivity of TLD loaded with metal has little energy dependence. Conclusion : The good stability and linearity with respect to monitor units of TLD loaded with metal were demonstrated by relative measurements in high energy Photon ($6\~15$ MV) beams. The TLD laminated with metals embedded system in solid water phantom is a suitable detector for relative dose measurements in a small beam size and surface dose.

  • PDF

Friction Properties of Carbon Coated Ultra-thin Film using Taguchi Experimental Design (다구찌 실험계획법을 이용한 탄소코팅 초박막의 마찰특성)

  • 안준양;김대은;최진용;신경호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.4
    • /
    • pp.143-150
    • /
    • 2003
  • Frictional properties of ultra-thin carbon coatings on silicon wafer were investigated based on Taguchi experimental design method. Sensitivity analysis was performed with normal load, relative humidity, deposition process, and coating thickness as the variables. It was found that despite low thickness, the carbon coating resulted in relatively low friction coefficient. Also, the frictional behavior was affected significantly by humidity and normal load.

The Mechanical Sensitivity at Interfaces between Bone and Interbody Cage of Lumbar Spine Segments (Lumbar spine 의 뼈와 Interbody cage의 접촉면에서 기계공학적 민감성 고찰)

  • Kim Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.295-301
    • /
    • 2000
  • It is known that among many factors, relative micromotion at bone/implant interfaces can hinder bone ingrowth into surface pores of an implant. Loading conditions, mechanical properties of spinal materials, friction coefficients at the interfaces and geometry of spinal segments would affect the relative micromotion and spinal stability. A finite clement model of the human lumbar spine segments (L4-L5) was constructed to investigate the mechanical sensitivity at the interfaces between bone and cage. Relative micromotion. Posterior axial displacement. bone stress, cage stress and friction force were predicted in changes of friction coefficients, loading conditions. bone density and age-related material/geometric properties of the spinal segments. Relative micromotion (slip distance in a static loading means relative micromotion in routine activity) at the interfaces increased significantly as the mechanical properties of cancellous bone, annulus fibers or/and ligaments decrease or/and as the friction coefficient at the interfaces decreases. The contact normal force at the interfaces decreased as cancellous bone density decreases or/and as the friction coefficient increases A significant increase of slip distance at anterior annulus occurred with an addition of torsion to compressive preload. Relative micromotion decreased with an increase of disc area. In conclusion. relative micromotion, stress response. Posterior axial displacement and contact normal force are sensitive to the friction coefficient of the interfaces, bone density, loading conditions and age-related geometric/material changes.

  • PDF