• Title/Summary/Keyword: Relative quantification

Search Result 302, Processing Time 0.03 seconds

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Dipyridamole in Human (디피리다몰 체내동태 연구를 위한 혈청 중 디피리다몰의 HPLC 정량법 개발 및 검증)

  • Cho, Hea-Young;Kang, Hyun-Ah;Moon, Jae-Dong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.1
    • /
    • pp.45-51
    • /
    • 2006
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of dipyridamole in human serum was developed, validated, and applied to the pharmacokinetic study of dipyridamole. Dipyridamole and internal standard, loxapine, were extracted from human serum by liquid-liquid extraction with diethyl ether and analyzed on a Nova Pak $C_{I8}$ column with the mobile phase of 40 mM ammonium acetate:methanol:acetonitrile (35:35:30)(v/v/v, pH 7.8). Detection wavelength of 280 nm and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed dipyridamole concentration (50 ng/mL) with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 2-2000 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 2 ng/mL, which was sensitive enough for pharmacokinetic studies of dipyridamole. The overall accuracy of the quality control samples ranged from 103.94 to 105.86% for dipyridamole with overall precision (% C.V.) being 4.60-11.49%. The relative mean recovery of dipyridamole for human serum was 97.64%. Stability studies showed that dipyridamole was stable during storage, or during the assay procedure in human serum. The peak area and retention time of dipyridamole were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of dipyridamole in human serum samples for the pharmacokinetic studies of orally administered Dimor tablet (75 mg as dipyridamole) at three different laboratories, demonstrating the suitability of the method.

Development and Validation of HPLC Method for Pharmacokinetic Study of Promethazine in Human (염산프로메타진 체내동태 연구를 위한 혈청 중 프로메타진의 HPLC 정량법 개발 및 검증)

  • Cho, Hae-Young;Kang, Hyun-Ah;Lee, Hwa-Jeong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.1
    • /
    • pp.23-29
    • /
    • 2006
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of promethazine in human serum was developed, validated, and applied to the pharmacokinetic study of promethazine. Promethazine and internal standard, chlorpromazine, were extracted from human serum by liquid-liquid extraction with n-hexane containing 0.8% isopropanol and analyzed on a Capcell Pak CN column with the mobile phase of acetonitrile-0.2 M potassium dihydrogen phosphate (42:58, v/v, adjusted to pH 6.0 with 1 M NaOH). Detection wavelength of 251 nm and flow rate of 0.9 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed promethazine concentration (10 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 1-40 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 1 mL of serum was 1 ng/mL, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 96.15 to 105.40% for promethazine with overall precision (% C.V.) being 6.70-11.22%. The relative mean recovery of promethazine for human serum was 63.54%. Stability (freeze-thaw and short-term) studies showed that promethazine was stable during storage, or during the assay procedure in human serum. However, the storage at $-80^{\circ}C$ for 4 weeks showed that promethazine was not stable. Extracted serum sample and stock solution were not allowed to stand at ambient temperature for 12 hr prior to injection. The peak area and retention time of promethazine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of promethazine in human serum samples for the pharmacokinetic studies of orally administered Himazin tablet (25 mg as promethazine hydrochloride) at three different laboratories, demonstrating the suitability of the method.

Simultaneous determination of 37 volatile organic compounds at ng/L concentration level in surface water by HS-SPME-GC/MS (HS-SPME-GC/MS에 의한 지표수에서 ng/L 농도 수준의 37개 휘발성유기화합물의 동시 분석)

  • Kim, Tae-Seung;Hong, Suk-Young;Kim, Jong-Eun;Lim, Hyun-Hee;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.39-49
    • /
    • 2012
  • A method to detect 37 volatile organic compounds (VOCs) in surface water was described based on headspace solid-phase micro extraction and gas chromatography-mass spectrometry. VOCs in water were vaporized for 30 min at 40 $^{\circ}C$ in a headspace vial and adsorbed on 85 ${\mu}m$ carboxen-polydimethylsiloxane. Under the established condition, the lowest quantification limit was 4.1-96 ng/L by using 4.0 mL water sample, and the relative standard deviation was less than 15% at concentrations of 0.05 and 0.50 ${\mu}g/L$. The detection limits meet lower concentration than 1/10 of the water quality criteria for VOCs established by the US EPA or Germany. The LOQ is a sensitivity which the monitoring for the establishing water quality criteria requires. When the proposed method was used to analyze the target compounds in sixteen surface water samples and total 16 VOCs were detected in surface water samples collected from Gum-River. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples.

Development of Analytical Methods of Hyperoside from Rosa canina L. (Rosa canina L. 중 hyperoside의 시험법 개발 연구)

  • Oh, Jae Myoung;Lee, Hwa Jung;Bahn, Kyeong Nyeo;Seo, Il Won;Lee, Young Joo;Lee, Jin Hee;Park, Ji Min;Kang, Tae Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.173-177
    • /
    • 2015
  • Rosa canina L. is health functional food materials that can help to temporarily relieve symptoms of arthritis. This study has been conducted to develop and validate analytical methods for hyperoside of Rosa canina L.. Methods based on HPLC with ultraviolet detection (UVD) were established through instrumental analytical conditions, and the examination of data, such as domestic and foreign reliable methods and journals. HPLC UVD analysis using Capcell Pak $C_{18}$ MG II column at 353 nm was determined on test through the column, mobile phase. The validation has been performed on the method to determine linearity, accuracy, limits of quantification (LOQ) and repeatability for hyperoside. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.999, and the LOQ was $0.393{\mu}g/mL$. Relative standard deviation (RSD) values of data from repeatability precision was between 0.6 and 2.6%. Recovery rate test at hyperoside scored between 98 and 99%. These results indicate that the established HPLC method is very useful for the determination of hyperoside in Rosa canina L. to develop a health functional material.

Development of an Analytical Method for the Determination of Dexamethasone in Bovine Milk Using Liquid Chromatography Coupled to Tandem Mass Spectrometry (LC-MS/MS를 이용한 우유 중 덱사메타손의 잔류 분석법 개발)

  • Cha, Chun-Nam;Park, Eun-Kee;Yoo, Chang-Yeul;Lee, Sung Joong;Son, Song-Ee;Kim, Suk;Lee, Hu-Jang
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.418-423
    • /
    • 2017
  • An analytical method for the determination of dexamethasone (DM) in bovine milk samples was developed and validated using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Milk samples were extracted by the liquid-liquid extraction based on acetonitrile. The chromatographic separation was achieved on a reverse phase $C_{18}$ column with gradient elution using a mobile phase of 0.1% formic acid in 95% acetonitrile. The procedure was validated according to the Ministry of Food and Drug Safety guideline determining accuracy, precision, limit of detection (LOD), and limit of quantification (LOQ). Mean recoveries of DM from spiked milk samples (25, 125, and 1,250 ng/mL) were 98.9-109.6%, and the relative standard deviation was between 1.7 and 4.4%. Linearity in concentration range of 12.5-1,250 ng/mL was obtained with the correlation coefficient ($r^2$) of 0.9997. LOD and LOQ for the investigated DM were 0.15 and 0.5 ng/mL depending on milk samples, respectively. This method was reliable, sensitive, economical and suitable for routine monitoring of DM residues in bovine milk.

Analytical method validation and monitoring of levulinic acid in soy sauce and their application to food (간장 및 이를 활용한 식품의 레불린산 분석방법 검증 및 모니터링)

  • Kim, Dan-Bi;Kim, Sunyoung;Lee, Sanghee;Yoo, Miyoung
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.295-302
    • /
    • 2017
  • This study presents a method validation for extraction and quantitative analysis of levulinic acid in soy sacues using high performance liquid chromatograph-photodiode array detector (HPLC-PDA). The levulinic acid in samples were extracted with distilled water, and then purified with C18 Sep-Pak cartridge. The calibration curves showed good linearity (R > 0.999) in a relatively wide concentration range ($2.5-400{\mu}g/mL$). Mean recoveries and relative standard deviation (RSD) of levulinic acid spiked in soy sauce samples at different spiking levels ($2.5-400{\mu}g/mL$; 6 point). Recoveries were 87.58-97.26 % with RSD less than 15 %, and limit of detection (LOD) and limit of quantification (LOQ) were 0.64 and $1.64{\mu}g/mL$, respectively. According to monitoring result with the established method, levulinic acid was found in 43 of 59 domestic commercial soy sauces, soy sauce based sauces and seasoned meats. The contamination levels were 0.44-1.23 mg/mL for soy sauces, 0.03-0.83 mg/mL for soy sauce based sauces and 8.43-38.94 mg/mL for seasoned meats. The results indicated to be rapidly and accurately qualifying levulinic acid and can be used as a suitable quality control method for soy sauce and soy sauce related commodities.

Determination of 11 Illicit Compounds in Dietary Supplements Using High-Performance Liquid Chromatography and Liquid Chromatography-Tandem Mass Spectrometry

  • Shin, Dasom;Kang, Hui-Seung;Kim, Hyung-soo;Moon, Guiim
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.4
    • /
    • pp.326-333
    • /
    • 2020
  • In this work, we developed an analytical method for determining 11 illicit compounds in dietary supplements using high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry. Eleven target compounds, including those meant for weight loss (7-keto-dihydroepiandrosterone, buformin, metformin, phenformin, salbutamol, and tolbutamide), sexual enhancement (dihydroepiandrosterone), and relaxation (asarone, kavain, magnoflorine, and picamilon) were screened and confirmed in dietary supplements. Method validation was performed by evaluating the selectivity, linearity, limit of quantification (LOQ), accuracy, and precision according to the Association of Official Analytical Chemists guidelines. The linearity was > 0.993 for all analytes. The LOQs were ranged in 2.1-9.9 ㎍/mL (HPLC-DAD) and 0.002-0.008 ㎍/mL (LC-MS/MS). The accuracies (expressed as recovery) were 90.0-106% (HPLC-DAD) and 83.0-114% (LC-MS/MS). The precision (expressed as the relative standard deviation) was below 10% using HPLC and LC-MS/MS. The proposed method can be used for the surveillance of illicit compounds in dietary supplements.

HPLC analytical method validation of Aralia elata extract as a functional ingredients (두릅 추출물의 기능성 원료 표준화를 위한 HPLC 분석법 검증)

  • Ahn, Eun-Mi;Choi, Song-Am;Choi, Ji-Young
    • Food Science and Preservation
    • /
    • v.24 no.6
    • /
    • pp.795-801
    • /
    • 2017
  • Aralia elata Seemann (AE) has long been used as a folk medicine for the treatment of various diseases including diabetes mellitus, anti-arthritic, and anti-gastric ulcer agent in Korea, Japan, and China. This study was performed to establish a simple and reliable HPLC/UV analytical method for determination of most active anti-hypertensive compound, a 3-O-${\alpha}$-L-rhamnopyranosyl($1{\rightarrow}$2)-${\alpha}$-L-arabinopyranosyl hederagenin 28-O-${\beta}$-D-xylopyranosyl($1{\rightarrow}6$)-${\beta}$-D-glucopyranosylester (HE) for the standardization of the shoot extract of AE as a health functional food ingredient. The quantitative analytical method of HE was optimized by HPLC analysis using reverse-phase C18 column at $40^{\circ}C$ with $H_2O$ and acetonitrile (70:30, v/v) as an isocratic mobile phase at a flow rate of 1.0 mL/min and detection wavelength of UV 205 nm. This HPLC/UV analytical method showed good specificity and high linearity in the tested range of 0.03125-2.0mg/ml with excellent coefficient of determination ($R^2$) of 0.9999. The limit of detection and limit of quantification were $12.0{\mu}g/mL$ and $36.5{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 0.2% and 0.1%, respectively. These results indicate that the established HPLC/UV analytical method is very simple, specific, precise, accurate, and reproducible and thus can be useful for the quantitative analysis of HE as a functional anti-hypertensive compound in AE extract.

Quantitative Analysis and Qualification of Amitrole Using LC/ESI-MS (LC/ESI-MS를 이용한 아미트롤의 정성확인 및 정량분석)

  • Park, Chan-Koo;Eo, Soo-Mi;Kim, Min-Young;Sohn, Jong-Ryeul;Mo, Sae-Young
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.117-129
    • /
    • 2004
  • Amitrole in environment, difficult to be analyzed by GC or GC/MS due to high polarity and low volatility, was analyzed by LC/ESI/MS in the study. Maximum peak intensity of amitrole in LC/MS/ESI mass spectrum is m/z 85 of protonated molecular ion $(M+H)^+$ with 30V of cone voltage at SIR mode. It was confirmed that ratios between main ion of amitrole, 85 of protonated molecular ion, and m/z 58 fragmented ion of amitrole, had increased corresponding with the increment of cone voltage from 20V to 70V. The isotope molecular weight of amitrole was $86([M+H])^+$ at LC/MS analysis and the mass spectrum ratio between 85 mass and 86 mass was not different by the change of concentration but similar to theoretical ratio(less than 10% standard deviation).The linearity of standard calibration curve under same condition with sample treatment method had $y=1.09354e^6X+26947.2$ and $r^2=0.99$. Recovery rates in water and soil samples were 77.64~83.44% and 71.11~79.44%, respectively. Reliability of the analysis was performed with 5 repeated measurements at each level of standard concentration and the result showed that relative standard deviation was less than 10%; therefore, the extraction and analysis method in the study suggested that it would be reliable to measure amitrole in water and soil media.

Cost Comparison of PWR and PHWR Nuclear Power Plants in Korea

  • Kim, Chang-Hyo;Chung, Chang-Hyun;So, Dong-Sub
    • Nuclear Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.263-274
    • /
    • 1979
  • A statistical approach is used to investigate the relative economic advantages of pressurized water reactor (PWR) and pressurized heavy water reactor (PHWR-CANDU) nuclear power plants for hypothetical 900Mwe systems with the throwaway fuel cycle to be built in the Republic of Korea. Power cost is decomposed into the cost components related to the plant capital, operation and maintenance, working capital requirements and fuel cycle operation. The calculation of construction cost is performed with the modified version of computer code ORCOST, and the modified POWERCO-50 is used to evaluate the cost components. Most of economic parameters are treated as statistical variables, each being given with a certain range. Through a random sampling procedures. the probability histograms on unit plant construction costs and power generating costs are obtained. The power cost probability histograms of the PWR and the PHWR plants overlap considerably, and the power costs of two systems appear to be almost same with the PHWR power cost being 0.4mil1/kwh lower compared with 39.4 mills/kwh for the PWR plant (July 1986 US-dollars). When a construction period of PHWR plant is longer by one year than that of PWR plant, there is no difference in the unit power cost of two plants. This comparison leads to no definite conclusion on the cost advantage of the PWR plant versus the PHWR plant. We conclude that the selection issue of nuclear power plants in Korea still remains an open question and that future effort to solve this question should be made toward economic quantification of those factors such as technology transfer and localization.

  • PDF